Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “angular resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Probing Charge Ordering in Fractional Mixed-Valence Charge Density Wave Systems with Oriented HERFD-XANES Spectroscopy

In this paper, we present oriented Pt L III edge high energy resolution fluorescence detected X-ray absorption near edge structure (HERFD-XANES) measurements on a series of structurally tunable quasi-one-dimensional mixed-valence platinum-halide linear chain materials, [Pt(en) 2 ][Pt(en) 2 X 2 ](ClO 4 ) 4 with X = Cl, Br, I, together with ab initio modeling of the spectral components and electronic structure. The materials exhibit a commensurate charge density wave (CDW) with an amplitude controlled by the bridging halide ion, giving rise to fractional mixed valence states. Ab initio FEFF9 modeling of the spectra and the associated angular momentum projected density of states (lDOS) are used to interpret the results, revealing systematic changes in the platinum orbital occupancy through the series of materials that reflect the fractional mixed valence states of the CDW. A significant contribution to a post-edge feature in the oriented spectra is identified as resulting from quantum interference between the final states of the X-ray absorption transition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

POWTEX visits POWGEN

The high-intensity time-of-flight (TOF) neutron diffractometer POWTEX for powder and texture analysis is currently being built prior to operation in the eastern guide hall of the research reactor FRM II at Garching close to Munich, Germany. Because of the world-wide 3 He crisis in 2009, the authors promptly initiated the development of 3 He-free detector alternatives that are tailor-made for the requirements of large-area diffractometers. Herein is reported the 2017 enterprise to operate one mounting unit of the final POWTEX detector on the neutron powder diffractometer POWGEN at the Spallation Neutron Source located at Oak Ridge National Laboratory, USA. As a result, presented here are the first angular- and wavelength-dependent data from the POWTEX detector, unfortunately damaged by a 50 g shock but still operating, as well as the efforts made both to characterize the transport damage and to successfully recalibrate the voxel positions in order to yield nonetheless reliable measurements. Also described is the current data reduction process using the PowderReduceP2D algorithm implemented in Mantid [Arnold et al. (2014). Nucl. Instrum. Methods Phys. Res. A , 764 , 156–166]. The final part of the data treatment chain, namely a novel multi-dimensional refinement using a modified version of the GSAS-II software suite [Toby & Von Dreele (2013). J. Appl. Cryst. 46 , 544–549], is compared with a standard data treatment of the same event data conventionally reduced as TOF diffraction patterns and refined with the unmodified version of GSAS-II . This involves both determining the instrumental resolution parameters using POWGEN's powdered diamond standard sample and the refinement of a friendly-user sample, BaZn(NCN) 2 . Although each structural parameter on its own looks similar upon comparing the conventional (1D) and multi-dimensional (2D) treatments, also in terms of precision, a closer view shows small but possibly significant differences. For example, the somewhat suspicious proximity of the a and b lattice parameters of BaZn(NCN) 2 crystallizing in Pbca as resulting from the 1D refinement (0.008 Å) is five times less pronounced in the 2D refinement (0.038 Å). Similar features are found when comparing bond lengths and bond angles, e.g. the two N—C—N units are less differently bent in the 1D results (173 and 175°) than in the 2D results (167 and 173°). The results are of importance not only for POWTEX but also for other neutron TOF diffractometers with large-area detectors, like POWGEN at the SNS or the future DREAM beamline at the European Spallation Source.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wet compaction to a blue nugget: a critical phase in galaxy evolution

ABSTRACT We utilize high-resolution cosmological simulations to reveal that high-redshift galaxies tend to undergo a robust ‘wet compaction’ event when near a ‘golden’ stellar mass of $\sim \!\!10^{10}\, \rm M_\odot$ . This is a gaseous shrinkage to a compact star-forming phase, a ‘blue nugget’ (BN), followed by central quenching of star formation to a compact passive stellar bulge, a ‘red nugget’ (RN), and a buildup of an extended gaseous disc and ring. Such nuggets are observed at cosmic noon and seed today’s early-type galaxies. The compaction is triggered by a drastic loss of angular momentum due to, e.g. wet mergers, counter-rotating cold streams, or violent disc instability. The BN phase marks drastic transitions in the galaxy structural, compositional, and kinematic properties. The transitions are from star forming to quenched inside-out, from diffuse to compact with an extended disc or ring and a stellar envelope, from dark matter to baryon central dominance, from prolate to oblate stellar shape, from pressure to rotation support, from low to high metallicity, and from supernova to AGN feedback. The central black hole growth, first suppressed by supernova feedback when below the golden mass, is boosted by the compaction, and the black hole keeps growing once the halo is massive enough to lock in the supernova ejecta.

Lapiner, Sharon (ORCID:0009000409733232)↗

High-Spectral Resolution Lidar (HSRL) Instrument Handbook

High-spectral-resolution lidar (HSRL) systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar (RL), but unlike simple backscatter lidars such as the micropulse lidar (MPL), this enables the HSRL to measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations allow robust discrimination between ice and water clouds. Rigorous error estimates can be computed for all measurements. A very narrow angular field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. The laser transmitter is a diode-pumped, frequency-doubled Nd:YAG laser. Narrow-band, single-frequency operation is provided by injection seeding with a single-frequency, cw-diode-pumped diode laser. The main laser cavity is maintained in resonance with the seed laser by adjusting the cavity length to minimize the time between the Q-switch trigger and the emission of the laser pulse. The emission wavelength is tuned via temperature control of the seed laser crystal and is locked to line #1109 of the iodine absorption spectra. Locking is accomplished by minimizing the transmission through a 2-cm-long iodine absorption cell. Use of a high-repetition-rate laser and expansion of the transmitted beam through a 400-mm telescope reduces the transmitted energy density to eye-safe levels. It is possible to look directly into the output beam without hazard. The receiver and transmitter use the same afocal telescope, simplifying the maintenance of stable alignment of the transmitter and receiver although the angular FOV is only 100 μrad. The small FOV and the 4-kHz repetition rate also limit the near-field signal strength, making it possible to record continuous profiles that start at an altitude of ~100 m and extend to 30 km using photon counting detectors. The small FOV also suppresses multiple scattering contributions.

54 ENVIRONMENTAL SCIENCES↗

Scattering Calorimeter FY24 Deliverable Report

A simulation-based method has been developed to prototype new detector designs for nuclear data measurements utilizing neutron scattering. This method uses representative physics inputs for signal and background generation, full detector resolution smearing benchmarked by experimental data, and a neutron beam timing simulation to produce analyzable output like a physical measurement. A test case has been studied using a hybrid time-of-flight calorimeter detector for scattering cross-section measurements on 239 Pu with 1-5 MeV incident monoenergetic neutrons. Data analysis methods have been developed to perform event-level particle reconstruction and reaction channel discrimination. This analysis has been used to estimate the capability of the test detector to perform simultaneous scattering and fission cross section measurements, as well as its ability to provide neutron spectra and particle angular information.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spatiotemporal sampling of near-petahertz vortex fields

Measuring the field of visible light with high spatial resolution has been challenging, as many established methods only detect a focus-averaged signal. Here, we introduce a near-field method for optical field sampling that overcomes that limitation by employing the localization of the enhanced near-field of a nanometric needle tip. A probe field perturbs the photoemission from the tip, which is induced by a pump pulse, generating a field-dependent current modulation that can easily be captured with our electronic detection scheme. The approach provides reliable characterization of near-petahertz fields. We show that not only the spiral wavefront of visible femtosecond light pulses carrying orbital angular momentum (OAM) can be resolved but also the field evolution with time in the focal plane. Additionally, our method is polarization sensitive, which makes it applicable to vectorial field reconstruction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Practical considerations for measuring global spin density matrix elements of vector mesons in heavy-ion collisions

The STAR Collaboration has reported a significant 𝜙-meson global spin alignment (𝜌 00 ) signal in Au+Au collisions at $\sqrt{s_{NN}}$ ≤ 62 GeV by measuring the polar angle distribution of 𝜙-meson daughters with respect to the orbital angular momentum direction of the collision system. Here, in this paper, a new method is explored for studying vector-meson global spin alignment in heavy-ion collisions by examining the two-dimensional (2D) polar and azimuthal angle distribution. This method allows simultaneous extraction of 𝜌 00 and off-diagonal spin density matrix elements (SDMEs), providing unique access to local quark-antiquark spin correlations and spin hydrodynamics in quark-gluon plasma. The new 2D method also removes potential biases from nonzero off-diagonal SDMEs on 𝜌 00 with the 1D method. A detailed procedure to correct for detector acceptance and resolution effects is also presented and validated by simulation studies.

Wilks, Gavin [University of Illinois, Chicago, IL ↗

Two-electron interference in two-photon attosecond double ionization of neon

The pump-probe experiments enabled by x-ray free-electron lasers (XFEL) will allow us to directly observe correlated electronic motion with attosecond time resolution by detecting photoelectron pairs in coincidence. In helium, the transition between the nonsequential and sequential regime in two-photon double ionization (TPDI) is well explained by a virtual-sequential model. Much less is known, however, about the TPDI process in more complex atoms. Recently, we extended the virtual-sequential model to arbitrary light pulses [Chattopadhyay Phys. Rev. A 108, 013114 (2023)]. This extension employs multichannel scattering states for the single ionization of both the neutral and the ionized target, which we initially applied to helium. In the present study, we show that our extended virtual-sequential model reproduces the qualitative features of the angularly integrated observables with available experimental results for neon, a considerably more complex target. We observe an intriguing feature of inverted two-particle interference in the joint-energy distribution of Ne compared to He. Finally, this phenomenon, attributable to the presence of a final doubly ionized state with triplet symmetry coupled to the two photoelectrons, should be observable with current experimental technologies.

74 ATOMIC AND MOLECULAR PHYSICS↗

High Resolution Photoelectron Spectroscopy of the Acetyl Anion

High-resolution photoelectron spectra of cryogenically cooled acetyl anions (CH 3 CO - ) obtained using slow photoelectron velocity-map imaging are reported. The high resolution of the photoelectron spectrum yields a refined electron affinity of 0.4352 ± 0.0012 eV for the acetyl radical as well as the observation of a new vibronic structure that is assigned based on ab initio calculations. Three vibrational frequencies of the neutral radical are measured to be 1047 ± 3 cm -1 (ν 6 ), 834 ± 2 cm -1 (ν 7 ), and 471 ± 1 cm -1 (ν 8 ). Here this work represents the first experimental measurement of the ν 6 frequency of the neutral. The measured electron affinity is used to calculate a refined value of 1641.35 ± 0.42 kJ mol -1 for the gas-phase acidity of acetaldehyde. Analysis of the photoelectron angular distributions provides insight into the character of the highest occupied molecular orbital of the anion, revealing a molecular orbital with strong d-character. Additionally, details of a new centroiding algorithm based on finite differences, which has the potential to decrease data acquisition times by an order of magnitude at no cost to accuracy, are provided.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Semi-inclusive direct photon + jet and 𝜋 0 + jet correlations measured in 𝑝 + 𝑝 and central Au + Au collisions at $\sqrt{s_{NN}}$ = 200GeV

The STAR experiment at RHIC reports new measurements of jet quenching based on the semi- inclusive distribution of charged-particle jets recoiling from direct photon (γ dir ) and neutral pion (π 0 ) triggers in pp and central Au + Au collisions at $\sqrt{s_{NN}}$ = 200 GeV, for triggers in the range 9 < $E$$^{trig}_{T}$ < 20 GeV. The datasets have integrated luminosities of 3.9nb −1 for Au + Au and 23pb −1 for 𝑝𝑝 collisions. Jets are reconstructed using the anti-𝑘 𝑇 algorithm with resolution parameters 𝑅 = 0.2 and 0.5. The large uncorrelated jet background in central Au + Au collisions is corrected using a mixed-event approach, which enables precise charged-particle jet measurements at low transverse momentum 𝑝$^{ch}_{𝑇,jet}$ and large 𝑅. Recoil-jet distributions are reported in the range 𝑝$^{ch}_{𝑇,jet}$ < 25 GeV/𝑐. Comparison of the distributions measured in 𝑝𝑝 and Au + Au collisions reveals strong medium-induced jet yield suppression for 𝑅 = 0.2 with markedly less suppression for 𝑅 = 0.5. Comparison is also made to theoretical models incorporating jet quenching. Furthermore, these data provide new insight into the mechanisms underlying jet quenching and the angular dependence of medium-induced jet-energy transport and provide new constraints on modeling such effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Chasing ghosts: characterization of artifact generation in coded aperture decoding due to experimental implementation

Coded aperture imaging is a form of lensless aperture imaging that projects multiple overlapping images of the source onto the detector, enhancing signal strength, which is advantageous for low-flux sources or high-resolution imaging. This technique requires decoding of the detector signal to reconstruct the original source, which involves convolving the detector data with the aperture pattern. When the signal is from a centered point source, the reconstructed source image is known as the point spread function (PSF). A clean PSF without artifacts is a Dirac delta function [Appl. Opt. 20, 1858 (1981)]. This paper examines the robustness of the decoding process against variations in experimental tolerances by analyzing artifact growth in the reconstructed PSF. We illustrate the effects of incorrect magnification, rotation, and detector size and find that aperture–detector rotational misalignment about the imaging axis is the most sensitive parameter, with significant artifact generation occurring with angular offsets of less than one degree. We discuss compensation methods for imperfect aperture placement, finding that small detector sizes produce uncompensatable artifact generation, and compare theoretical predictions with experimental PSF measurements of a rank , 6.8 mm thick (less than one mean free path) coded aperture with a 3.5 mm cell size, conducted at the MegaJOuLe Neutron Imaging Radiography dense plasma focus [IEEE Trans. Plasma Sci. 49, 3299 (2021)] using a 2.45 MeV neutron source. Based on our findings, we recommend using magnified coded apertures in the under-sampled regime, which allows for the inclusion of fiducial markers to characterize aperture–detector rotational offsets and the addition of mechanical coupling, where possible, to constrain rotational and magnification offsets.

Selwood, M. P. [Lawrence Livermore National Labora↗

Synthetic-aperture radar (SAR) imaging with range-resolved reflection data

SAR imaging may be performed with range-resolved reflection data, where a spread-spectrum signal, such as a code division multiple access (CDMA) signal, is transmitted instead of a simple frequency chirp. The reflected spread-spectrum signal may be analyzed to gather range-resolved reflection data. Range-resolved reflection data may be gathered at each angular view. This data may be used to construct a more accurate approximation of the Fourier transform of the desired image than can be done by a conventional SAR approach. The image may be reconstructed from this Fourier transform using Fourier inversion techniques similar to those used in conventional SAR approaches. The range-resolved reflection scheme generally requires somewhat more processing to recover the image as compared with conventional SAR systems, but provides a significantly more stable image with less degradation from effects that plague conventional SAR systems. This can eliminate the need for phase coherency altogether and also eliminate “phase drift,” which leads to image distortion. This may be especially well suited for high resolution imaging of relatively large targets.

47 OTHER INSTRUMENTATION↗

AuriDESI: mock catalogues for the DESI Milky Way Survey

The Dark Energy Spectroscopic Instrument Milky Way Survey (DESI MWS) will explore the assembly history of the Milky Way by characterizing remnants of ancient dwarf galaxy accretion events and improving constraints on the distribution of dark matter in the outer halo. We present mock catalogues that reproduce the selection criteria of MWS and the format of the final MWS data set. These catalogues can be used to test methods for quantifying the properties of stellar halo substructure and reconstructing the Milky Way’s accretion history with the MWS data, including the effects of halo-to-halo variance. The mock catalogues are based on a phase-space kernel expansion technique applied to star particles in the Auriga suite of six high-resolution lambda-cold dark matter magnetohydrodynamic zoom-in simulations. They include photometric properties (and associated errors) used in DESI target selection and the outputs of the MWS spectral analysis pipeline (radial velocity, metallicity, surface gravity, and temperature). They also include information from the underlying simulation, such as the total gravitational potential and information on the progenitors of accreted halo stars. We discuss how the subset of halo stars observable by MWS in these simulations corresponds to their true content and properties. These mock Milky Ways have rich accretion histories, resulting in a large number of substructures that span the whole stellar halo out to large distances and have substantial overlap in the space of orbital energy and angular momentum.

dynamics↗

The SPT-3G+ Experiment on the South Pole Telescope

Observations of the cosmic microwave background (CMB) offer an unparalleled opportunity to advance our understanding of fundamental physics. SPT-3G+ is an upgraded receiver for the arcminute-resolution South Pole Telescope (SPT) that plans to deploy in late 2028. SPT-3G+ will increase the CMB mapping speed of SPT by nearly an order of magnitude over the currently installed SPT-3G receiver. SPT-3G+ will have ~24,000 transition-edge sensor (TES) bolometers in two frequency bands with center frequencies at 95 GHz and 150 GHz that will be read out with microwave multiplexing. SPT-3G+ will measure the CMB lensing spectrum and galaxy clusters to constrain the growth of structure, dark matter, and dark energy. SPT-3G+ will also reach critical thresholds on inflationary constraints by combining data with BICEP/Keck, forming the South Pole Observatory (SPO). BICEP/Keck has deep degree-angular scale measurements but is currently delensing-limited, while SPT-3G+ will provide deep lensing measurements. Forecasts show that SPO will reach an uncertainty on the tensor-to-scalar ratio $r$ of $\sigma(r) \sim 1.2\times 10^{-3}$ by 2034. A detection at these levels would provide evidence of inflation and probe new physics at grand unified theory energy scales, while no detection would exclude large classes of models and shift the scientific paradigm describing the early universe. I will give an overview of SPT-3G+ including its design and current status.

Simon, Sara M. [Fermilab] (ORCID:0009000006683584)↗

A JWST Survey of the Supernova Remnant Cassiopeia A

We present initial results from a James Webb Space Telescope (JWST) survey of the youngest Galactic core-collapse supernova remnant, Cassiopeia A (Cas A), made up of NIRCam and MIRI imaging mosaics that map emission from the main shell, interior, and surrounding circumstellar/interstellar material (CSM/ISM). We also present four exploratory positions of MIRI Medium Resolution Spectrograph integral field unit spectroscopy that sample ejecta, CSM, and associated dust from representative shocked and unshocked regions. Surprising discoveries include (1) a weblike network of unshocked ejecta filaments resolved to ~0.01 pc scales exhibiting an overall morphology consistent with turbulent mixing of cool, low-entropy matter from the progenitor's oxygen layer with hot, high-entropy matter heated by neutrino interactions and radioactivity; (2) a thick sheet of dust-dominated emission from shocked CSM seen in projection toward the remnant's interior pockmarked with small (~1'') round holes formed by ≲0$^"_•$1 knots of high-velocity ejecta that have pierced through the CSM and driven expanding tangential shocks; and (3) dozens of light echoes with angular sizes between ~0$^"_•$1 and 1' reflecting previously unseen fine-scale structure in the ISM. NIRCam observations place new upper limits on infrared emission (≲20 nJy at 3 μm) from the neutron star in Cas A's center and tightly constrain scenarios involving a possible fallback disk. These JWST survey data and initial findings help address unresolved questions about massive star explosions that have broad implications for the formation and evolution of stellar populations, the metal and dust enrichment of galaxies, and the origin of compact remnant objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Design of a Thomson scattering diagnostic for the SMall Aspect Ratio Tokamak (SMART)

Here, we describe the design of a Thomson scattering (TS) diagnostic to be used on the SMall Aspect Ratio Tokamak (SMART). SMART is a spherical tokamak being commissioned in Spain that aims to explore positive triangularity and negative triangularity plasma scenarios at a low aspect ratio. The SMART TS diagnostic is designed to operate at high spatial resolution, 6 mm scattering length in the low-field side and 9 mm in the high-field side regions, and a wide dynamic range, electron temperature from 1 eV to 1 keV and density from 5 x 10 18 m -3 to 1 x 10 20 m -3 ⁠, to resolve large gradients formed at the plasma edge and in the scrape-off layer (SOL) under different triangularities and low aspect ratios. A 2 J @1064 nm laser will be used that is capable of operating in the burst mode at 1, 2, and 4 kHz to investigate fast phenomena and at 30 Hz to study 1 s (or more) long discharges. The scattered light will be collected over an angular range of 60° – 120° from 28 spatial points in the midplane covering the entire plasma width and the outer midplane SOL. Each scattering signal will be spectrally resolved on five wavelength channels of a polychromator to obtain the electron temperature measurement. We will also present a method to monitor in situ laser alignment in the core during calibrations and plasma operations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

OGLE-2018-BLG-1185b: A Low-mass Microlensing Planet Orbiting a Low-mass Dwarf

We report an analysis of the planetary microlensing event OGLE-2018-BLG-1185, which was observed by a large number of ground-based telescopes and by the Spitzer Space Telescope. The ground-based light curve indicates a low planet–host star mass ratio of q = (6.9 ± 0.2) × 10{sup −5}, which is near the peak of the wide-orbit exoplanet mass-ratio distribution. We estimate the host star and planet masses with a Bayesian analysis using the measured angular Einstein radius under the assumption that stars of all masses have an equal probability of hosting the planet. The flux variation observed by Spitzer is marginal, but still places a constraint on the microlens parallax. Imposing a conservative constraint that this flux variation should be Δf {sub Spz} < 4 instrumental flux units yields a host mass of M{sub host}=0.37{sub −0.21}{sup +0.35} M{sub ⊙} and a planet mass of m{sub p}=8.4{sub −4.7}{sup +7.9} M{sub ⊕}. A Bayesian analysis including the full parallax constraint from Spitzer suggests smaller host star and planet masses of M{sub host}=0.091{sub −0.018}{sup +0.064} M{sub ⊙} and m{sub p}=2.1{sub −0.4}{sup +1.5} M{sub ⊕}, respectively. Future high-resolution imaging observations with the Hubble Space Telescope or Extremely Large Telescope could distinguish between these two scenarios and help reveal the planetary system properties in more detail.

47 OTHER INSTRUMENTATION↗

Mechanical Design Progress of the In Situ Nanoprobe Instrument for APS-U

The In Situ Nanoprobe (ISN, 19-ID) beamline will be a new best-in-class long beamline to be constructed as part of the Advanced Photon Source Upgrade (APS-U) project [1, 2]. To achieve long working distance at high spatial resolution, the ISN instrument will be positioned 210 m downstream of the x-ray source, in a dedicated satellite building, currently under construction [3]. The ISN instrument will use a nano-focusing Kirkpatrick-Baez (K-B) mirror system, which will focus hard x-rays to a focal spot as small as 20 nm, with a large working distance of 61 mm. The large working distance provides space for various in situ sample cells for x-ray fluorescence tomography and ptychographic 3D imaging, allows the use of a separate, independent vacuum chambers for the optics and sample, and provides the flexibility to run experiments in vacuum or at ambient pressure. A consequence of the small spot size and large working distance are stringent requirements for high angular stability of the K-B mirrors (5 nrad V-mirror and 16 nrad H-mirror) and high relative stability be-tween focus spot and sample (4 nmRMS). Additional features include fly-scanning up to 2 kg mass, sample plus in situ cell, at 1 mm/s in vertical and/or horizontal directions over an area of 10 mm x 10 mm. Environmental capabili-ties will include heating and cooling, flow of fluids and applied fields, as required for electrochemistry and flow of gases at high temperature for catalysis. To achieve these capabilities and precise requirements we have used precision engineering fundamentals to guide the design process.

Kearney, Steven P.↗