Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Quantitative time-resolved diagnostics of electric field dynamics during individual plasma breakdown events using burst laser pulse electric field induced second harmonic generation

In plasma discharges, the acceleration of electrons by a fast varying electric field and the subsequent collisional electron energy transfer determines the plasma dynamics, chemical reactivity, and breakdown. Current in situ electric field measurements require reconstruction of the temporal profile over many observations. However, such methods are unsuitable for non-repetitive and unstable plasmas. Here, in this paper, we present a method for creating “movies” of dynamic electric fields in a single acquisition at sample rates of 500 × 10 6 fps. This ultrafast diagnostic was demonstrated in radio frequency electric fields between two parallel plates in air, as well as in Ar nanosecond-pulsed single-sided dielectric barrier discharges.

42 ENGINEERING↗

Characterization and alignment of a resonant cavity beam position monitor for the Compact LInear Collider (CLIC) project at CERN

Beam diagnostic devices are essential tools to sense the properties of the beam in particle accelerators. Beam Position Monitors (BPMs) are used to detect the transverse beam spatial coordinates. A large number of high-resolution resonant cavity BPMs, operating at 14GHz, are proposed to monitor the orbit of the two main beam linacs of the CLIC project. This paper discusses innovative calibration techniques on a dedicated test bench in the frame of the PACMAN project. The particular location of the electromagnetic center of the resonant cavity BPM is detected utilizing a stretched-wire measurement approach. Measurements, RF characterization and final fiducialization of the BPM electrical offset are treated with details. Initial studies through EM simulations of the cavity BPM are covered. The presented experimental results prove the feasibility of the alignment methodology with nanometric resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying concentration distributions in redox flow batteries with neutron radiography

Abstract The continued advancement of electrochemical technologies requires an increasingly detailed understanding of the microscopic processes that control their performance, inspiring the development of new multi-modal diagnostic techniques. Here, we introduce a neutron imaging approach to enable the quantification of spatial and temporal variations in species concentrations within an operating redox flow cell. Specifically, we leverage the high attenuation of redox-active organic materials (high hydrogen content) and supporting electrolytes (boron-containing) in solution and perform subtractive neutron imaging of active species and supporting electrolyte. To resolve the concentration profiles across the electrodes, we employ an in-plane imaging configuration and correlate the concentration profiles to cell performance with polarization experiments under different operating conditions. Finally, we use time-of-flight neutron imaging to deconvolute concentrations of active species and supporting electrolyte during operation. Using this approach, we evaluate the influence of cell polarity, voltage bias and flow rate on the concentration distribution within the flow cell and correlate these with the macroscopic performance, thus obtaining an unprecedented level of insight into reactive mass transport. Ultimately, this diagnostic technique can be applied to a range of (electro)chemical technologies and may accelerate the development of new materials and reactor designs.

Science & Technology - Other Topics↗

Reflections

Flash radiography is a much used diagnostic technique for high-explosively driven hydrodynamic experiments. Two linear-induction electron accelerators (LIAs) at the Los Alamos Dual Axis Radiography of Hydrodynamic Tests (DARHT) facility provide the source spots for point projection radiography of exceptionally large and dense experiments. In these LIAs, the beam acceleration is provided by high-voltage pulses applied to a number of inductively isolated gaps. The high-voltage pulses are produced by remotely located pulsedpower generators and delivered to the gaps by long highvoltage cables. For Scorpius, these pulse generators are called line replacement units (LRUs).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Pinhole/Occulter Facility

A large occulting system in space can be used for high resolution X-ray observations and for large aperture coronagraphic observations in visible and UV light. The X-ray observations can combine high angular resolution in hand (10 keV) X-radiation with the high sensitivity of a multiple pinhole camera, and can permit sensitive observations of bremsstrahlung from nonthermal particles in the corona. The large aperture coronagraphs have two major advantages: high angular resolution and good photon collection. This will permit observations of small scale structures in the corona for the first time and will give sufficient counting rates above the coronal background rates for sensitive diagnostic analysis of intensities and line profiles for coronal structures in the solar wind acceleration region. The technical basis for performing observations with a large occulting system in these three wavelength ranges is described as well as a pinhole/occulter facility presently being considered for Spacelab. Some indications about future developments are included.

Hudson, H. S.↗

Space Experiments with Particle Accelerators (SEPAC)

The purpose of Space Experiments with Particle Accelerators (SEPAC) on the Atmospheric Laboratory for Applications and Science (ATLAS 1) mission, is to carry out active and interactive experiments on and in the earth's ionosphere, atmosphere, and magnetosphere. The instruments to be used are an electron beam accelerator (EBA), plasma contactor, and associated instruments the purpose of which is to perform diagnostic, monitoring, and general data taking functions. Four major classes of investigations are to be performed by SEPAC. They are: beam plasma physics, beam-atmosphere interactions, the use of modulated electron beams as transmitting antennas, and the use of electron beams for remote sensing of electric and magnetic fields. The first class consists mainly of onboard plasma physics experiments to measure the effects of phenomena in the vicinity of the shuttle. The last three are concerned with remote effects and are supported by other ATLAS 1 investigations as well as by ground-based observations.

Obayashi, Tatsuzo↗

A Summary of the NASA Fusion Propulsion Workshop 2000

A NASA Fusion Propulsion Workshop was held on Nov. 8 and 9, 2000 at Marshall Space Flight Center (MSFC) in Huntsville, Alabama. A total of 43 papers were presented at the Workshop orally or by posters, covering a broad spectrum of issues related to applying fusion to propulsion. The status of fusion research was reported at the Workshop showing the outstanding scientific research that has been accomplished worldwide in the fusion energy research program. The international fusion research community has demonstrated the scientific principles of fusion creating plasmas with conditions for fusion burn with a gain of order unity: 0.25 in Princeton TFTR, 0.65 in the Joint European Torus, and a Q-equivalent of 1.25 in Japan's JT-60. This research has developed an impressive range of physics and technological capabilities that may be applied effectively to the research of possibly new propulsion-oriented fusion schemes. The pertinent physics capabilities include the plasma computational tools, the experimental plasma facilities, the diagnostics techniques, and the theoretical understanding. The enabling technologies include the various plasma heating, acceleration, and the pulsed power technologies.

Thio, Y. C. Francis↗

Open-Air Manufacturing of Efficient Large-Area Perovskite Solar Cells to Meet Stability and Cost Targets

This SETO-funded project (DE-EE0009516) developed a fully open-air manufacturing pathway for perovskite solar cells and modules, eliminating vacuum-based processing steps while improving device stability. Open-air ultrasonic spray deposition, solution combustion synthesis, rapid thermal processing, and atmospheric plasma curing were developed and optimized for all functional device layers — perovskite absorber, hole transport layers (HTLs), electron transport layers (ETLs), transparent conducting oxides (TCOs), and rear electrodes — without reliance on vacuum. Sprayed organic ETLs preserved perovskite crystal structure and enabled power conversion efficiencies exceeding 20%, and open-air processed TCOs and rear electrodes achieved optoelectronic performance comparable to sputtered alternatives at substantially lower manufacturing cost. Device stability was assessed through accelerated aging protocols aligned with IEC and ISOS standards, combined with high-throughput optical diagnostics that identified key degradation mechanisms and antagonistic interactions among heat, humidity, and illumination stressors. A comprehensive technoeconomic analysis quantified the cost and throughput advantages of open-air manufacturing over conventional vacuum-based processes, identifying vacuum deposition as the dominant cost driver and demonstrating a clear pathway toward the $0.02/kWh target. The project produced five peer-reviewed journal publications, eleven conference presentations, two patents/applications, and five Ph.D. dissertations.

14 SOLAR ENERGY↗

Time-resolved measurement of electron beam neutralization

An intense relativistic electron beam (IREB) incident on a target generates positive ions by stimulated and thermal desorption of adsorbed gas, and subsequent electron impact ionization. These ions are accelerated upstream by the beam space-charge potential, thereby partially neutralizing the beam. If there is enough neutralization, the repulsive space-charge force can be overcome by the magnetic-pinch force due to the beam current. This so-called ion focusing is responsible for time dependent defocusing of the radiographic source spot. Since a single monolayer of adsorbed gas has a surface density of about 10 15 /cm 2 and is formed in about one second in a one micro-Torr vacuum, there is always enough adsorbed gas to make this a concern in our accelerators. Therefore, time-resolved measurements of the degree of neutralization are valuable for better understanding of this process with an eye to mitigation for improvement of our radiography. Moreover, these measurements would aid quantification of uncertainties due to these effects when using invasive beam diagnostics, such as OTR imaging targets.

43 PARTICLE ACCELERATORS↗

A Wide Dynamic-Range Halo Monitor for 8 GeV Proton Beams at FNAL

Eliminating harmful beam halos is the most important technique for high-intensity proton accelerators. Therefore, beam halo diagnosis is indispensable and becomes more and more important. At J-PARC, a wide dynamic range monitor was installed in the beam transport line in 2012. The device is a two-dimensional beam profile monitor [*, **], and it has a dynamic range of approximately six digits of magnitude by using Optical Transition Radiation and fluorescence screens. The FNAL accelerator complex has been upgrading through increased beam intensity and beam quality. A new beam halo diagnostic device is required in the beam transport line between the booster and recycler. It will be manufactured in a collaboration between J-PARC and FNAL as a part of the U.S.-Japan Science and Technology Cooperation Program in High Energy Physics. We are redesigning the monitor to satisfy FNAL specifications for beam energy, intensity, and size. The equipment will be manufactured at J-PARC and then shipped to FNAL in 2024. In this report, the design of the device will be described.

43 PARTICLE ACCELERATORS↗

Exploring Causes of Beam Loss at CEBAF

At Jefferson Lab, the Continuous Electron Beam Accelerator (CEBAF) features a unique design with two linear accelerators and two arc sections allowing for multiple turns of the electron beam, as well as four experimental end stations. This topology leads to increased beam losses, especially in the spreader and recombiner regions connecting the arcs to the linacs and in the extraction regions connecting the experimental end stations to the accelerator. These losses result in equipment activation and operational interruptions. Recent upgrades to the facility’s diagnostic systems, including the addition of xenon ion chambers, have provided higher-resolution data regarding these loss events. Building on this improved observational capability, we are developing a simulation framework using optics codes and the Geant4-based BDSIM to model beam extinction and halo formation in these regions. This work aims to correlate simulation results with experimental data to isolate the causes of beam loss and inform future machine tuning strategies. We present a summary of conclusions drawn from recent operational studies and outline a plan to model the beam loss and validate the simulations.

Matthews, C. [Old Dominion Univ., Norfolk, VA (Uni↗

Single electron in a storage ring: a probe into the fundamental properties of synchrotron radiation and a powerful diagnostic tool

An experimental study of undulator radiation generated by a single electron was carried out at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. Photons were detected with a single-photon avalanche diode (SPAD) at an average rate of 20 kHz, corresponding to one detection every few hundred revolutions. Events were continuously recorded by a picosecond event timer for as long as 5 minutes at a time. The collected data were used to directly test the predictions of classical Poisson photostatistics. The study was motivated in part by a previous observation of sub-Poissonian statistics in a similar experiment with synchrotron radiation. In addition, we show that the time series of recorded events can be used to study the synchrotron motion of a single electron, yielding dynamical parameters such as the phase jitter of the radiofrequency cavity and the dependence of the synchrotron period on amplitude. Research plans for further experiments are also discussed.

47 OTHER INSTRUMENTATION↗

Feedback, physics, and forecasts: The emerging paradigm of machine learning-driven battery research

Machine learning (ML) is reshaping how we understand, predict, and optimize electrochemical systems. In batteries, ML accelerates discovery across chemistry, design, and operation by transforming massive experimental and simulated datasets into predictive, interpretable models. This review consolidates a decade of progress in ML-driven battery innovation, from early-cycle feature extraction to operando image analysis and physics-informed modeling. We categorize approaches by data domain and physical fidelity, emphasizing interpretable ML for diagnostics, reinforcement learning for control, and multi-objective optimization for lifetime extension strategies. Additionally, we demonstrate how integrated models accelerate discovery, reduce testing time, and guide sustainable design. Economic analyses furthermore illustrate how these advances can lower cost per cycle and improve circularity. Together, these developments chart a path toward self-optimizing, sustainable battery technologies.

artificial intelligence↗

Computational modeling and neutron imaging to understand interface shape and solute segregation during the vertical gradient freeze growth of BaBrCl:Eu

In this work we apply continuum models to analyze phase change, heat transfer, fluid flow, solute transport, and segregation in order to understand prior neutron imaging observations of the vertical gradient freeze growth of Eu-doped BaBrCl. The models provide a rigorous framework in which to understand the mechanisms that are responsible for the complicated evolution of interface shape and dopant distribution in the growth experiment. We explain how a transition in the solid/liquid interface shape from concave to convex is driven by changes in radial heat transfer caused by furnace design. We also provide a mechanistic explanation of how dynamic growth conditions and changes of the flow structure in the melt result in complicated segregation patterns in this system. A growth pause caused by controller lock-up is shown to result in a band of solute depletion in accordance with classical theory. However, changing flow patterns during growth result in a non-monotonic axial distribution of solute that cannot be explained by simple application of classical segregation models. We assert that the approach presented here, namely the use of rigorous models in conjunction advanced diagnostics, such as neutron imaging, provides an exciting path forward for process optimization and control, accelerating the incremental advances that have, in the past, typically relied on empiricism, experience, and intuition.

36 MATERIALS SCIENCE↗

The computation of isentropic atmospheric trajectories using a 'discrete model' formulation

An explicit technique for calculating atmospheric trajectories is presented as an alternative method to the standard implicit scheme of Danielsen (1961). The technique uses the inviscid equations of motion and the discrete model formulation derived by Greenspan (1972, 1973) to compute trajectories on isentropic surfaces, assuming adiabatic flow. The discrete model formulation is designed specifically for a Lagrangian system and objectively accounts for the geostrophic departures, local psi-tendencies, and the subsequent accelerations along the entire length of the trajectory. Application of the discrete formulation to a diagnostic case study yielded favorable results.

Petersen, R. A.↗

Physics-constrained superresolution diffusion for six-dimensional phase space diagnostics

Adaptive physics-constrained superresolution diffusion is developed for noninvasive virtual diagnostics of the six-dimensional (6D) phase space density of charged particle beams. An adaptive variational autoencoder embeds initial beam condition images and scalar measurements to a low-dimensional latent space from which a 32 6 pixel 6D tensor representation of the beam's 6D phase space density is generated. Projecting from a 6D tensor generates physically consistent two-dimensional projections. Physics-guided superresolution diffusion transforms low-resolution images of the 6D density to high resolution 256 × 256 pixel images. Unsupervised adaptive latent space tuning enables tracking of time-varying beams without knowledge of time-varying initial conditions. The method is demonstrated with experimental data and multiparticle simulations at the HiRES UED. The general approach is applicable to a wide range of complex dynamic systems evolving in high-dimensional phase space. The method is shown to be robust to distribution shift without retraining. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗

Effect of cervicolabyrinthine impulsation on the spinal reflex apparatus

In view of the fact that the convergence effect of vestibular impulsation may both stimulate and inhibit intra and intersystemic coordination of physiological processes, an attempt was made to define the physiological effect on the spinal reflex apparatus of the convergence of cervicolabyrinthine impulsation on a model of the unconditioned motor reflex as a mechanism of the common final pathway conditioning the formation and realization of a focused beneficial result of human motor activities. More than 100 persons subjected to rolling effect and angular acceleration during complexly coordinated muscular loading were divided according to typical variants of the functional structure of the patella reflex in an experiment requiring 30 rapid counterclockwise head revolutions at 2/sec with synchronous recording of a 20 item series of patella reflex acts. A knee jerk coefficient was used in calculations. In 85 percent of the cases 2 patellar reflexograms show typical braking and release of knee reflex and 1 shows an extreme local variant. The diagnostic and prognostic value of these tests is suggested for determining adaptive possibilities of functional systems in respect to acceleration and proprioceptive stimuli.

Yarotskiy, A. I.↗