Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “XENON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Earth-catalyzed detection of magnetic inelastic dark matter with photons in large underground detectors

Inelastic dark matter with moderate splittings, $\mathcal{O}$ (few to 150) keV, can upscatter to an excited state in the Earth, with the excited state subsequently decaying, leaving a distinctive monoenergetic photon signal in large underground detectors. The photon signal can exhibit sidereal-daily modulation, providing excellent separation from backgrounds. Using a detailed numerical simulation, we examine this process as a search strategy for magnetic inelastic dark matter with the dark matter mass near the weak scale, where the upscatter to the excited state and decay proceed through the same magnetic dipole transition operator. At lower inelastic splittings, the scattering is dominated by moderate mass elements in the Earth with high spin, especially 27 Al, while at larger splittings, 56 Fe becomes the dominant target. We show that the proposed large volume gaseous detector CYGNUS will have excellent sensitivity to this signal. Xenon detectors also provide excellent sensitivity through the inelastic nuclear recoil signal, and if a future signal is seen, we show that the synergy among both types of detection can provide strong evidence for magnetic inelastic dark matter. In the course we have calculated nuclear response functions for elements relevant for scattering in the Earth, which are publicly available on GitHub.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of energy resolution with the NEXT-White silicon photomultipliers

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}$Kr data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9 ± 0.6)%, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs.[graphic not available: see fulltext]

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Earth-scattering induced modulation in low-threshold dark matter experiments

Dark matter particles with sufficiently large interactions with ordinary matter can scatter in the Earth before reaching and scattering in a detector. This induces a modulation in the signal rate with a period of one sidereal day. We calculate this modulation for sub-GeV dark matter particles that interact either with a heavy or an ultralight dark-photon mediator and investigate the resulting signal in low-threshold detectors consisting of silicon, xenon, or argon targets. The scattering in the Earth is dominated by dark matter scatters off nuclei, while the signal in the detector is easiest to observe from dark matter scattering off electrons. We investigate the properties of the modulation signal and provide projections of the sensitivity of future experiments. We find that a search for a modulation signal can probe new regions of parameter space near the energy thresholds of current experiments, where the data are typically dominated by backgrounds.

Models for Dark Matter↗

Quantifying the Potential of Argon Detection Capabilities for Nuclear Explosion Monitoring

Abstract Current noble gas detection systems for nuclear explosion monitoring are based on the detection of four radioxenon isotopes—Xe-131m, -133, -133m and -135. The data provided by radioxenon detection could be enhanced by other radionuclide signatures such as Ar-37. Activation of Ca-40 in rock by neutrons produces Ar-37, and monitoring for this additional nuclide could help distinguish detections of nuclear explosions from background sources, such as medical isotope production. This work studies the capabilities of a hypothetical argon detection network. A 10 kt explosion was modeled using MCNP and SCALE to determine the inventory of Ar-37 created in a representative granite rock layer, assuming either 0.1, 1 or 10% of the total inventory was released. The Ar-37 inventory was combined with atmospheric transport data from HYSPLIT compiled in a previous study, along with the detection limits of standard Ar-37 detection systems, to determine how many hypothetical monitoring stations would detect Ar-37 from an explosion. This method was repeated for 365 HYSPLIT data sets to create a year’s worth of hypothetical explosions, releases, and detections. The study quantified the average number of detections per release, the number of stations detecting Ar-37, and the possibility of detecting Ar-37 in coincidence with xenon.

37Ar↗

In the nuclear explosion monitoring context, what is an anomaly?

Abstract In the early years of nuclear explosion monitoring, experts used downwind detections with meaningful ratios of radioactive species to identify an explosion. Today’s reality is sparse networks of radionuclide monitoring stations looking for weak signals. Analysts need to discriminate between industrial background radioactivity and nuclear explosion signals, even using the detection of one isotope. Aerosol and xenon measurements potentially related to nuclear tests in 2006 and 2013 announced by the Democratic People’s Republic of Korea and from worldwide civilian background radioactivity are considered when defining radionuclide detection anomalies to objectively guide the use of limited analyst resources and reduce the possibility of not detecting nuclear explosions.

Miley, Harry S.↗

Measuring Gas Transport and Sorption in Large Intact Geologic Specimens via the Piezometric Method

Uptake of noble gases into heterogeneous geologic core samples was measured using a piezometric methodology. In addition to measuring accessible porosity—as with gas pycnometry—by monitoring the rate of pressure decay, this method can also be used to estimate the gas effective diffusivity in the sample. In contrast to previous applications of this method, where milligram quantities of fractured grains are characterized, here approximately kilogram core samples were left intact when tested. In doing so, a more representative sample of the heterogeneous field geology is provided. Additionally, alteration of the pore structure and connectivity during sample preparation is avoided. Furthermore, to scale the piezometric method from milligrams to kilograms, the system was designed to operate at medium vacuum (1 to 100 Pa) to restrict transport in pores less than approximately 60 µm to large Knudsen numbers. To test the system performance, two samples of interest were selected: a rhyolitic welded tuff from Blue Canyon Dome at the Energetic Materials Research and Testing Center and a zeolitized non-welded rhyolitic tuff from the Nevada National Security Site. Three noble gases were utilized in this test series; Argon and xenon as they are of direct interest to nuclear monitoring efforts and helium as it is a weakly adsorbing reference standard. Additionally, mercury intrusion porosimetry measurements were made on subsamples of the core to compare the observed porosity by the two methods and to discuss gas transport rates in the context of the measured pore distribution.

58 GEOSCIENCES↗

Reproducible benchmark for the SNAP 8 experimental reactor at operating conditions

This work presents fully reproducible multiphysics benchmark models of the Systems for Nuclear Auxiliary Power (SNAP) 8 Experimental Reactor at operating conditions with coolant flow. Wet experiment (with coolant, at power) validation benchmarks are presented using both deterministic (Serpent-Griffin) and Monte-Carlo (OpenMC-Cardinal) multiphysics frameworks coupled with thermal-hydraulic solvers in MOOSE. Reactivity coefficient measurements including fuel temperature, isothermal temperature, and power coefficients show good agreement with experiments, with discrepancies within experimental uncertainty. Reactivity worth experiments for coolant, samarium, and xenon poisoning are reproduced with differences under 200 pcm. Comparison between Serpent-Griffin and OpenMC-Cardinal frameworks reveal multiphysics coupling introduces positive reactivity effects (100-200 pcm) compared to uniform temperature and density fields at nominal operating conditions. Comparison between Serpent-Griffin and reference Serpent solution shows that power distributions maintain consistent radial and axial peaking behavior. All models, assumptions, thermophysical and thermomechanical properties, and material definitions are thoroughly documented with cited references; model inputs and model generating scripts are stored in the snapReactors GitHub repository.

SNAP↗

127 Xe quantification method development and intercomparison exercise

Monitoring of the atmosphere for fission products ( 131m Xe, 133m Xe, 133 Xe, and 135 Xe) is performed by various laboratories to detect nuclear explosions. Quantification of 127 Xe is not routinely performed by laboratories measuring atmospheric radioxenon because it is not a fission product. 127 Xe was recently detected by a ground-based beta-gamma air monitoring system. When measured using beta-gamma coincidence detector systems, such as those in use on the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), 127 Xe can interfere with the quantification of fission product radioxenon due to overlap of the 127 Xe beta-gamma coincidence signatures with those of fission product radioxenon. Here, this work demonstrates quantification of 127 Xe at different laboratories with different measurement techniques. Production and purification of 127 Xe was performed by neutron activation of enriched 126 Xe. The purified 127 Xe was then split between laboratories, and detection and quantification methods were developed. At Idaho National Laboratory, a quantification method involving high purity germanium detectors was devised that included self-attenuation correction. At AWE, a beta-gamma coincidence counting method, as used in support of the IMS, was modified to enable the measurement and analysis of the 127 Xe samples. Corrections were made for self-attenuation, which showed a strong xenon volume dependency, for some coincidence signatures. The gas sample activity concentration was used as the comparison metric and it showed excellent agreement between the methods.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Precise half-life determination of 131 Ba and 125 Xe

Barium-131 and Xenon-125 are valuable radioisotopes with numerous scientific and medical applications. Here, we produced both isotopes via proton irradiation of a cesium iodide (CsI) target at the Brookhaven Tandem Van de Graaff accelerator (BTVG). Following irradiation, we conducted systematic γ-ray spectroscopy measurements at the National Nuclear Data Center (NNDC) decay station using a calibrated High-Purity Germanium (HPGe) detector, collecting data over a 2-month period (spanning approximately 4.5 half-lives for 131 Ba). Through careful analysis of the characteristic γ-ray emissions from both isotopes, we determined the half-life of 131 Ba to be 11.55(6) days, which agrees with the previously evaluated value. For 125 Xe, we measured a half-life of 16.56(8) hours, slightly lower than the evaluated value.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the gamma ray background in the Davis cavern at the Sanford Underground Research Facility

Deep underground environments are ideal for low background searches due to the attenuation of cosmic rays by passage through the earth. However, they are affected by backgrounds from γ -rays emitted by 40 K and the 238 U and 232 Th decay chains in the surrounding rock. The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a liquid xenon TPC located within the Davis campus at the Sanford Underground Research Facility, Lead, South Dakota, at the 4850-foot level. In order to characterise the cavern background, in-situ γ -ray measurements were taken with a sodium iodide detector in various locations and with lead shielding. The integral count rates (0–3300 keV) varied from 596 Hz to 1355 Hz for unshielded measurements, corresponding to a total flux from the cavern walls of 1.9 ± 0.4 γ cm −2 s −1 . The resulting activity in the walls of the cavern can be characterised as 220 ± 60 Bq/kg of 40 K, 29 ± 15 Bq/kg of 238 U, and 13 ± 3 Bq/kg of 232 Th.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study of events with photoelectric emission in the DarkSide-50 liquid argon Time Projection Chamber

Finding unequivocal evidence of dark matter interactions in a particle detector is a major goal of research in physics. Liquid argon time projection chambers offer a path to probe Weakly Interacting Massive Particles scattering cross sections on nuclei down to the so-called neutrino floor, in a mass range from a few GeV to hundreds of TeV. Based on the successful operation of the DarkSide-50 detector at LNGS, a new and more sensitive experiment, DarkSide-20k, has been designed and is now under construction. A thorough understanding of the DarkSide-50 detector response and, therefore, of all types of events observed in the detector, is essential for the optimal design of the new experiment. In this article, we report on a specific set of events, namely, standard two-pulse scintillation–ionization signals with a third small amplitude pulse, occurring within the 440 μ s data acquisition window of standard events. Some of these events are due to the photoionization of the TPC cathode. We compare our results with those published by collaborations using liquid xenon time projection chambers, which observed a similar phenomenon, and, in particular, with a recent paper by the LUX Collaboration (D.S. Akerib et al. Phys.Rev.D 102, 092004 (2020)) From the measured rate of these events, we estimate for the first time the quantum efficiency of the tetraphenyl butadiene deposited on the DarkSide-50 cathode at wavelengths of around 128 nm, in liquid argon. Also, both experiments observe events likely related to the photoionization of impurities in the liquid. The probability of photoelectron emission per unit length turns out to be an order of magnitude lower in DarkSide-50 than in LUX.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anisotropic thermal diffusivity and conductivity in SiC/SiC tubes studied by infrared imaging and X-ray computed tomography

Traditional flash diffusivity evaluation of thermal diffusivity/conductivity of composite tubes require machining of specimens. For a thin-wall tube, this method can only be used to obtain through-thickness transport property. A novel method to evaluate anisotropic thermal diffusivity in a composite tube has been developed. Braided SiC/SiC composite tubes were subjected to a xenon flash heating pulse. A high-speed, high-sensitivity infrared camera was used to measure surface temperature changes as a function of time and nondestructively detect subsurface defects/damages, such as macroscopic pores. Standard reference material (Pyroceram 9606) and curved SiC/SiC composite tube specimens were used to validate thermal diffusivity obtained from infrared imaging. Unlike the traditional method, there is no need prepare special specimens, and thermal diffusivity values in three orientations are obtained after a single flash. A finite element analysis model based on x-ray computed tomography scans was developed to simulate the heat transfer. In conclusion, this technique is significant in assessing thermal conductivity and inspecting the health of ceramic tubes during and after service.

36 MATERIALS SCIENCE↗

Krypton storage capacity of the Earth's lower mantle

Noble gases are important geochemical tracers allowing reconstructing global volatile cycles in Earth's reservoirs. To constrain these fundamental processes, precise data on their partitioning behavior at deep Earth conditions are needed. Such data are only available at moderate pressures up to 25 GPa due to experimental challenges. We have investigated the possibility of noble gas storage in the Earth's lower mantle up to 115 GPa. We studied the incorporation of krypton in the second most abundant lower mantle mineral (Mg 1-x ,Fe x )O (ferropericlase) as well as in liquid metal-alloys by performing experiments up to 115 GPa and 3700 K using the laser-heated diamond anvil cell coupled to post-mortem EMPA analysis and X-ray absorption spectroscopy. The results reveal that, at these extreme conditions, up to 3 wt.% of krypton can be stored in (Mg 1-x ,Fe x )O and 3000 ppm in the Fe-rich liquid metal. For both phases the storage capacities increase with pressure (between 40 GPa and 60 GPa) at a constant high temperature of 2300 K. Fpc has never been considered as a NG host, despite being the second most abundant mineral in the Earth's LM. Using recent accurate compressibility data, we demonstrate that a substitution of krypton into the anion site of (Mg 1-x ,Fe x )O in form of neutral oxygen Schottky defects at diluted lower mantle conditions is possible. This noble gas incorporation mechanism is in agreement with a previous study on bridgmanite. We show that (Mg 1-x ,Fe x )O exhibits higher noble gas storage capacities than bridgmanite through the lower mantle using lattice strain modeling and including experimental solubility and thermoelastic data for neon, argon, krypton and xenon. We also demonstrate that both phases exhibit the highest solubilities for argon and krypton. We used the solubility data from lattice strain modeling to predict noble gas abundances stored in the solid lower mantle after magma ocean crystallization. The modeled abundances show apparent similarities with estimates for the deep noble gas reservoir that are based on either 3He abundances in ocean island basalts or radiogenic 40Ar abundances in the bulk Earth. This strongly indicates that the crystalline lower mantle may play an important role as deep noble gas storage reservoir. We propose, based on considerations on noble gas replenishment from the lower mantle to the atmosphere, that the lower mantle can only contribute to a small fraction of the present-day atmospheric noble gases. This suggests that the lower mantle is an un-degassed reservoir.

58 GEOSCIENCES↗

The spore coat is essential for Bacillus subtilis spore resistance to pulsed light, and pulsed light treatment eliminates some spore coat proteins

Microbial surface contamination of equipment or of food contact material is a recurring problem in the food industry. Spore-forming bacteria are far more resistant to a wide variety of treatments than their vegetative forms. Understanding the mechanisms underlying decontamination processes is needed to improve surface decontamination strategies against endospores potentially at the source of foodborne diseases or food-spoilage. Pulsed light (PL) with xenon lamps delivers high-energy short-time pulses of light with wavelengths in the range 200 nm-1100 nm and a high UV-C fraction. Bacillus subtilis spores were exposed to either PL or to continuous UV-C. Gel electrophoresis and western blotting revealed elimination of various proteins of the spore coat, an essential outer structure that protects spores from a wide variety of environmental conditions and inactivation treatments. Proteomic analysis confirmed the elimination of some spore coat proteins after PL treatment. Transmission electron microscopy of PL treated spores revealed a gap between the lamellar inner spore coat and the outer spore coat. Overall, spores of mutant strains with defects in genes coding for spore coat proteins were more sensitive to PL than to continuous UV-C. This study demonstrates that radiations delivered by PL contribute to specific damage to the spore coat, and overall to spore inactivation. Keywords Decontamination, UV, proteins, proteomics, microscopy Journal Pre-proof

59 BASIC BIOLOGICAL SCIENCES↗

Possible impacts of molten salt reactors on the International Monitoring System

Molten salt reactors (MSRs) are gaining support as many countries look for ways to increase power generation and replace aging nuclear energy production facilities. MSRs have inherently safe designs, are scalable in size, can burn transuranic wastes from traditional solid fuel nuclear reactors, can store excess heat in thermal reservoirs for water desalination, and can be used to produce medical isotopes as part of the real-time liquid-fuel recycling process. The ability to remove 135 Xe in real time from the fuel improves the power production in an MSR because 135 Xe is the most significant neutron-absorbing isotope generated by nuclear fission. Xenon-135, and other radioactive gases, are removed by sparging the fuel with an inert gas while the liquid fuel is recirculated from the reactor inner core through the heat exchangers. Without effective abatement technologies, large amounts of radioactive gas could be released during the sparging process. This work examines the potential impact of radioxenon releases on samplers used by the International Monitoring System (IMS) to detect nuclear explosions. Here, atmospheric transport simulations from seven hypothetical MSRs on different continents were used to evaluate the holdup time needed before release of radioxenon so IMS samplers would register few detections. Abatement technologies that retain radioxenon isotopes for at least 120 d before their release will be needed to mitigate the impacts from a molten salt breeder reactor used to replace a nuclear power plant. A holdup time of about 150 d is needed to reduce emissions to the average level of current nuclear power plants.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Comparison of source-location algorithms for atmospheric samplers

Numerous algorithms have been developed to determine the source characteristics for an atmospheric release, e.g., (Bieringer et al., 2017). This study compares three models that have been applied to the data collected by the International Monitoring System operated by the Comprehensive Nuclear-Test-Ban Treaty Preparatory Commission to estimate source event parameters. Each model uses a different approach to estimate the parameters. A deterministic model uses a possible source region (PSR) approach (Ringbom et al., 2014) that is based on the correlation between predicted and measured sample values. An unnamed model developed at Pacific Northwest National Laboratory (herein called BAYEST) uses a Bayesian formulation (Eslinger et al., 2019; Eslinger et al., 2020; Eslinger and Schrom, 2016). The FREAR model uses a different Bayesian formulation (De Meutter and Hoffman, 2020; De Meutter et al., 2021; Pieter De Meutter, 2021). The performance of the three source-location models is evaluated with 100 synthetic release cases for the single xenon isotope, 133 Xe. The release cases resulted in detections in a fictitious network with 120 noble gas samplers. All three source-location models use the same sampling data. The two Bayesian models yield more accurate location estimates than the deterministic PSR model, with FREAR having slightly better location performance than BAYEST. Samplers with collection periods of 3, 6, 8, 12, and 24-h were used. Results from BAYEST show that location accuracy improves with each reduction in sample collection length. The BAYEST model is slightly better for estimating the start time of the release. The PSR model has about the same spread in start times as the FREAR model, but the PSR results have a better average start time. The Bayesian source-location algorithms give more accurate results than the PSR approach, and provide release magnitude estimates, while the base PSR model does not estimate the release magnitude. This investigation demonstrates that a reasonably dense sampling grid will sometimes yield poor location and time estimates regardless of the model. The poor estimates generally coincide with cases where there is a much larger distance between the release point and the first detecting sampler than the average sampler spacing.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Detecting 127 Xe in an atmospheric tracer experiment

The Xcounts algorithm for calculating air concentrations of radioactive xenon isotopes (Eslinger et al., 2023) has been extended to estimate 127 Xe in addition to 131m Xe, 133m Xe, 133 Xe, and 135 Xe. The algorithm was applied to 119 samples collected with a SAUNA Q B system (Ringbom et al., 2023) during a two-month atmospheric tracer release experiment. Finally, the algorithm identified two samples with 127 Xe present from a single 1.5 h release about 3.5 km upwind of the sampler and no false detections of 127 Xe were observed in the other samples.

127Xe calibration↗

Analysis of 127 Xe tracer measurements using a net counts method

A suite of measurement systems were deployed as part of the Physical Experiment 1 series of experiments, which involved detonating chemical explosives along with radionuclide tracers in an underground cavity, at the Nevada National Security Site (NNSS) in the United States. One of the radionuclide tracers, 127 Xe was released from the containment following the explosion and detected on a SAUNA Q B sampler situated approximately 3.5 km away. The system uses a beta-gamma coincidence detector system to measure fission product radioisotopes of xenon relevant to nuclear explosion monitoring. In this work we use the coincidence measurement data to analyse and interpret the results from the SAUNA Q B system, to calculate the measured 127 Xe activity concentration(s).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗