SEARCH · Engineering Papers
Results for “Worker”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Wearable Robotics and Exoskeletons for WM Workers: Potential Benefits and Challenges.
Abstract not provided.
Estimating Worker Dose of Transuranic Aerosol Inhalation by Measuring Cerium Oxide Powder Releases from Drop Tested Storage Containers
Explore the source record for details and available documents.
Wearable Robotic Devices to Improve Worker Health and Safety.
Abstract not provided.
SAFEGUARDP: AN ARCHITECTURE FOR MEDIATED CONTROL OF DESKTOP APPLICATIONS BY UNTRUSTED CROWD WORKERS.
Abstract not provided.
CONVINCING THE CRAFTSMAN ? A STUDY OF WHAT WORKS AND WHAT DOESN?T WITH RESPECT TO EDUCATING THE ELECTRICAL WORKER ABOUT ELECTRICAL SAFETY.
Abstract not provided.
Non-Lab Contingent Workers
Explore the source record for details and available documents.
Recognition and Respect of Cultural Differences in the Development and Delivery of Safety Training for the Non English Speaking Worker.
Abstract not provided.
Improving Decommissioning Success using the Tool of Virtual Reality; Increasing Worker Safety and Project Schedule Stability - 17193
operations, especially underwater, is essential. Equally essential is a precise game plan for disassembly which focuses attention on the skilled remote handling operators who must produce the results. Project success is based on clean, efficient cuts and take-aways, prepared paths for waste placement and containment, programmed return paths; and practice, practice, practice on the part of the operators. Recently, our Partner, WAK Ruackbau- und Entsorgungs- GmbH (Decommissioning and Waste Management Company) was tasked with dismantling and decommissioning the Karlsruhe Reprocessing Plant. The most difficult task in this project is the dismantling of the vitrification plant. Waelischmiller was selected to address this high-consequence project. Together, WAK and Waelischmiller determined that development of a virtual reality suite, where management and operators could create a virtual vitrification layout and subsequently map and rehearse their dismantling plan was essential. This approach, using Virtual Reality (VR) as a tool in streamlining operations and rehearsing difficult moves and cuts, will be a game changer for this and future projects. It will be a first-of-a-kind in Germany. The VR suite is contained in a room at the Karlsruhe facility with a large screen, control cabinet, simulation computer, a Waelischmiller Joyarm and Masterarm. To support the dismantling of the vitrification plant, WAK/HWM will conduct interactive feasibility studies for each dismantling step. All movements; cuts, take-aways and vessel segment insertion into transportation and disposal casks will be established, programed and practiced within virtual test suite. This allows savings in cost-intensive and complex construction of test rigs. Operating personnel can be trained in the VR suite, without taking the risk of damaging expensive remote handling equipment.While the operators are working on the operating element, they stand in front of a wide screen. Instead of a real TELBOT{sup R}, a virtual TELBOT{sup R} is moving on the screen in virtual reality. While practicing, the operators cannot damage the arm and the equipment, which is a big advantage. Moreover an interactive feasibility study can be realized without building a real test rig (mock-up). Consequently significant cost-expenses can be reduced. This paper will describe the virtual suite used by the WAK in Karlsruhe and the advantages of this new and innovative approach, which is unique in decommissioning of nuclear facilities. The viewpoint of each (WAK and HWM), and the decisions and benefits realized along the project path will be detailed in the paper. (authors)
Wearable Robots for Worker Assistance - 17464
Wearable Robots is a fast growing field with exoskeleton devices focused on augmenting, enhancing, and assisting human movement and strength. Devices have been designed for people with spinal cord injuries, stroke survivors, medical rehabilitation, assistance to the elderly, and recreation to aid in sports. For manufacturing and industry, devices are quickly being developed that allow the human and the robot to interact in a synergistic fashion to accomplish a task. (authors)
Human and Robotic Testing in Gloveboxes to Reduce Worker Fatigue - 19542
A DOE-sponsored study conducted by the Los Alamos National Laboratory reported that the incidence rate of repetitive stress injuries (RSI) during manipulation tasks in glovebox and hot cell workspaces increased from 22% after 1-2 hours of work per day to 50% after 3 hours of work per day due to fatigue, repetitive motion, and hyperextension. Robotics can be a viable solution to this issue as robotic manipulators and wearable robotic devices can provide effective assistance to alleviate the workload. In order to use the robotic devices, an initial study to detect the amount of fatigue experienced by the glovebox operators is essential. Hence, in the present research two objectives have been specified and investigated. These include the use of electromyography (EMG) sensors to precisely detect the fatigue in various hands, arm and shoulder muscles and; the use of dexterous robotic arm and hand combinations to effectively perform certain repetitive and monotonous tasks conducted inside an in-house glovebox constructed for the research. A UR5 robotic arm and an i-limb artificial hand have been used. Human tests included eight subjects and two customized glovebox tasks. Pilot scale test results indicate variation in the mean frequency which is an indication of the level of fatigue that occurred. (authors)
Dexterity and Worker Comfort in an Ergonomically Designed Glovebox Glove
Gloveboxes are prolifically used in nuclear facilities as the primary means of separation between the hazardous material and operators. Due to extended duration and high repetition of hand tasks in glovebox gloves, improperly fitting gloves can be uncomfortable and increase injury risks. Poor fit can increase time necessary to perform work tasks and stress the glove itself. The Plutonium Facility has the largest inventory of glovebox gloves at Los Alamos National Laboratory (LANL) with approximately 6000 gloves installed. The current glove mold dates back to the 1960's and is not based on the true anatomy of the hand. Design flaws (poor anatomical fit and biomechanics) are directly related to injuries of the elbow (lateral epicondylitis) and thumb (DeQuervain's tenosynovitis) injuries. The current design also contributes to 30% of unplanned glove openings. A new glovebox glove was developed and manufactured, incorporating over forty dimensions to produce the most comprehensive ergonomically sound design. The new design received a LANL patent (patent attorney docket No: LANS 36USD1 'Protective Glove'), one of 20 highest patents awarded by the Richard P. Feynman Center for Innovation. A SolidWorks model was given to the manufacturer for production of the glove mold.
Dose estimation to a worker hand from depleted uranium handling - 25471
This work is a study of the dose to a hand from a depleted uranium (DU) slab. This research evaluates and compares the effective dose and localized skin-absorbed dose from handling depleted uranium. The analysis includes photons, neutrons, and beta particles emanating from depleted Uranium aged to 30 years. Although partial effective dose rates are small, the electron localized skin-absorbed dose rate is significant. These results may be used to check compliance with safety regulations, policies and procedures at the Los Alamos National Laboratory, and to build recommendations for the safe handling of depleted Uranium samples. (authors)
A Tale of Two Models: Understanding Data Workers Internal and External Representations of Heterogenous Data
Explore the source record for details and available documents.
Jack Healy Remembers - Anecdotal Evidence for the Origin of the Approximate 24-hour Urine Sampling Protocol Used for Worker Bioassay Monitoring
The origin of the approximate 24-hour urine sampling protocol used at Hanford for routine bioassay is attributed to an informal study done in the mid-1940s. While the actual data were never published and have been lost, anecdotal recollections by staff involved in the initial bioassay program design and administration suggest that the sampling protocol had a solid scientific basis. Numerous alternate methods for normalizing partial day samples to represent a total 24-hour collection have since been proposed and used, but no one method is obviously preferred.