Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WIND TUNNEL CALIBRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Sediment-transport experiments in zero-gravity

One of the important parameters in the analysis of sediment entrainment and transport is gravitational attraction. The availability of a laboratory in earth orbit would afford an opportunity to conduct experiments in zero and variable gravity environments. Elimination of gravitational attraction as a factor in such experiments would enable other critical parameters (such as particle cohesion and aerodynamic forces) to be evaluated much more accurately. A Carousel Wind Tunnel (CWT) is proposed for use in conducting experiments concerning sediment particle entrainment and transport in a space station. In order to test the concept of this wind tunnel design a one third scale model CWT was constructed and calibrated. Experiments were conducted in the prototype to determine the feasibility of studying various aeolian processes and the results were compared with various numerical analysis. Several types of experiments appear to be feasible utilizing the proposed apparatus.

Iversen, James D.↗

First International Symposium on Strain Gauge Balances

The first International Symposium on Strain Gauge Balances was sponsored and held at NASA Langley Research Center during October 22-25, 1996. The symposium provided an open international forum for presentation, discussion, and exchange of technical information among wind tunnel test technique specialists and strain gauge balance designers. The Symposium also served to initiate organized professional activities among the participating and relevant international technical communities. Over 130 delegates from 15 countries were in attendance. The program opened with a panel discussion, followed by technical paper sessions, and guided tours of the National Transonic Facility (NTF) wind tunnel, a local commercial balance fabrication facility, and the LaRC balance calibration laboratory. The opening panel discussion addressed "Future Trends in Balance Development and Applications." Forty-six technical papers were presented in 11 technical sessions covering the following areas: calibration, automatic calibration, data reduction, facility reports, design, accuracy and uncertainty analysis, strain gauges, instrumentation, balance design, thermal effects, finite element analysis, applications, and special balances. At the conclusion of the Symposium, a steering committee representing most of the nations and several U.S. organizations attending the Symposium was established to initiate planning for a second international balance symposium, to be held in 1999 in the UK.

John S Tripp↗

First International Symposium on Strain Gauge Balances

The first International Symposium on Strain Gauge Balances was sponsored and held at NASA Langley Research Center during October 22-25, 1996. The symposium provided an open international forum for presentation, discussion, and exchange of technical information among wind tunnel test technique specialists and strain gauge balance designers. The Symposium also served to initiate organized professional activities among the participating and relevant international technical communities. Over 130 delegates from 15 countries were in attendance. The program opened with a panel discussion, followed by technical paper sessions, and guided tours of the National Transonic Facility (NTF) wind tunnel, a local commercial balance fabrication facility, and the LaRC balance calibration laboratory. The opening panel discussion addressed "Future Trends in Balance Development and Applications." Forty-six technical papers were presented in 11 technical sessions covering the following areas: calibration, automatic calibration, data reduction, facility reports, design, accuracy and uncertainty analysis, strain gauges, instrumentation, balance design, thermal effects, finite element analysis, applications, and special balances. At the conclusion of the Symposium, a steering committee representing most of the nations and several U.S. organizations attending the Symposium was established to initiate planning for a second international balance symposium, to be held in 1999 in the UK.

Tripp, John S↗

The Benchmark Active Controls Technology Model Aerodynamic Data

The Benchmark Active Controls Technology (BACT) model is a part of the Benchmark Models Program (BMP). The BMP is a NASA Langley Research Center program that includes a series of models which were used to study different aeroelastic phenomena and to validate computational fluid dynamics codes. The primary objective of BACT testing was to obtain steady and unsteady loads, accelerations, and aerodynamic pressures due to control surface activity in order to calibrate unsteady CFD codes and active control design tools. Three wind-tunnel tests in the Transonic Dynamics Tunnel (TDT) have been completed. The first and parts of the second and third tests focused on collecting open-loop data to define the model's aeroservoelastic characteristics, including the flutter boundary across the Mach range. It is this data that is being presented in this paper. An extensive database of over 3000 data sets was obtained. This database includes steady and unsteady control surface effectiveness data, including pressure distributions, control surface hinge moments, and overall model loads due to deflections of a trailing edge control surface and upper and lower surface

Scott, Robert C.↗

A miniature 48-channel pressure sensor module capable of in situ calibration

A new high data rate pressure sensor module with in situ calibration capability has been developed by the Langley Research Center to help reduce energy consumption in wind-tunnel facilities without loss of measurement accuracy. The sensor module allows for nearly a two order of magnitude increase in data rates over conventional electromechanically scanned pressure sampling techniques. This module consists of 16 solid state pressure sensor chips and signal multiplexing electronics integrally mounted to a four position pressure selector switch. One of the four positions of the pressure selector switch allows the in situ calibration of the 16 pressure sensors; the three other positions allow 48 channels (three sets of 16) pressure inputs to be measured by sensors. The small size of the sensor module will allow mounting within many wind-tunnel models, thus eliminating long tube lengths and their corresponding slow pressure response.

Gross, C.↗

The NASA Langley 8-foot Transonic Pressure Tunnel calibration

The NASA Langley 8-Foot Transonic Pressure Tunnel is a continuous-flow, variable-pressure wind tunnel with control capability to independently vary Mach number, stagnation pressure, stagnation temperature, and humidity. The top and bottom walls of the test section are axially slotted to permit continuous variation of the test section Mach number from 0.2 to 1.2, the slot-width contour provides a gradient-free test section 50 in. long for Mach numbers equal to or greater than 1.0 and 100 in. long for Mach numbers less than 1.0. The stagnation pressure may be varied from 0.25 to 2.0 atm. The tunnel test section has been recalibrated to determine the relationship between the free-stream Mach number and the test chamber reference Mach number. The hardware was the same as that of an earlier calibration in 1972 but the pressure measurement instrumentation available for the recalibration was about an order of magnitude more precise. The principal result of the recalibration was a slightly different schedule of reentry flap settings for Mach numbers from 0.80 to 1.05 than that determined during the 1972 calibration. Detailed tunnel contraction geometry, test section geometry, and limited test section wall boundary layer data are presented.

Brooks, Cuyler W., Jr.↗

Planar Doppler Velocimetry for Large-Scale Wind Tunnel Testing

Recently, Planar Doppler Velocimetry (PDV) has been shown by several laboratories to offer an attractive means for measuring three-dimensional velocity vectors everywhere in a light sheet placed in a flow. Unlike other optical means of measuring flow velocities, PDV is particularly attractive for use in large wind tunnels where distances to the sample region may be several meters, because it does not require the spatial resolution and tracking of individual scattering particles or the alignment of crossed beams at large distances. To date, demonstrations of PDV have been made either in low speed flows without quantitative comparison to other measurements, or in supersonic flows where the Doppler shift is large and its measurement is relatively insensitive to instrumental errors. Moreover, most reported applications have relied on the use of continuous-wave lasers, which limit the measurement to time-averaged velocity fields. This work summarizes the results of two previous studies of PDV in which the use of pulsed lasers to obtain instantaneous velocity vector fields is evaluated. The objective has been to quantitatively define and demonstrate PDV capabilities for applications in large-scale wind tunnels that are intended primarily for the production testing of subsonic aircraft. For such applications, the adequate resolution of low-speed flow fields requires accurate measurements of small Doppler shifts that are obtained at distances of several meters from the sample region. The use of pulsed lasers provides the unique capability to obtain not only time-averaged fields, but also their statistical fluctuation amplitudes and the spatial excursions of unsteady flow regions such as wakes and separations. To accomplish the objectives indicated, the PDV measurement process is first modeled and its performance evaluated computationally. The noise sources considered include those related to the optical and electronic properties of Charge-Coupled Device (CCD) arrays and to speckle effects associated with coherent illumination from pulsed lasers. The signal noise estimates are incorporated into the PDV signal analysis process and combined with computed scattering signals using a Mie scattering theory for polydisperse smoke particles. The relevant parameters incorporate a range of practical aerodynamic test conditions and facility sizes. The results define the optimum instrument configurations, show that the expected signal levels from a practical PDV system are sufficiently large to allow its useful application in large facilities, and show that the expected velocity measurement uncertainties are small compared to the mean velocities of interest for most subsonic, large-scale wind tunnel testing. Experimental studies using several experimental bench-top setups are then described that validate the physics of the PDV model and to calibrate its computed results. The validated model allows estimates of the uncertainties of PDV measurements and a complete definition of the PDV capabilities to be made with sufficient confidence to decide the viability of PDV for large-scale wind tunnel applications.

McKenzie, Robert L.↗

Turbulence measurement in transonic flow

The paper examines the response of a hot-wire anemometer in transonic flow in a variable-density closed-circuit wind tunnel and presents measurements obtained in a transonic turbulent boundary layer. Typical calibration curves are shown which indicate that, in contrast to previous work, the wire can be operated in a condition that will allow a single sensitivity to the velocity-density product rather than to density and velocity independently. Using these calibrations, measurements of fluctuating density and velocity obtained in a 0.8 M turbulent boundary layer are obtained. Agreement with independently obtained velocity fluctuations justifies both the calibration and data reduction procedures.

Rose, W. C.↗

Curved-flow, rolling-flow, and oscillatory pure-yawing wind-tunnel test methods for determination of dynamic stability derivatives

The test capabilities of the Stability Wind Tunnel of the Virginia Polytechnic Institute and State University are described, and calibrations for curved and rolling flow techniques are given. Oscillatory snaking tests to determine pure yawing derivatives are considered. Representative aerodynamic data obtained for a current fighter configuration using the curved and rolling flow techniques are presented. The application of dynamic derivatives obtained in such tests to the analysis of airplane motions in general, and to high angle of attack flight conditions in particular, is discussed.

Chambers, J. R.↗

A high speed data acquisition and analysis system for transonic velocity, density, and total temperature fluctuations

The high speed Dynamic Data Acquisition System (DDAS) is described which provides the capability for the simultaneous measurement of velocity, density, and total temperature fluctuations. The system of hardware and software is described in context of the wind tunnel environment. The DDAS replaces both a recording mechanism and a separate data processing system. The data acquisition and data reduction process has been combined within DDAS. DDAS receives input from hot wires and anemometers, amplifies and filters the signals with computer controlled modules, and converts the analog signals to digital with real-time simultaneous digitization followed by digital recording on disk or tape. Automatic acquisition (either from a computer link to an existing wind tunnel acquisition system, or from data acquisition facilities within DDAS) collects necessary calibration and environment data. The generation of hot wire sensitivities is done in DDAS, as is the application of sensitivities to the hot wire data to generate turbulence quantities. The presentation of the raw and processed data, in terms of root mean square values of velocity, density and temperature, and the processing of the spectral data is accomplished on demand in near-real-time- with DDAS. A comprehensive description of the interface to the DDAS and of the internal mechanisms will be prosented. A summary of operations relevant to the use of the DDAS will be provided.

Clukey, Steven J.↗

A new look at wind tunnel flow quality for transonic flows

The implementation of several transonic hot wire anemometry techniques for obtaining fluctuating data related to wind tunnel flow quality has been evaluated. An overview of the theoretical considerations, calibration techniques, and related assumptions are discussed for the data presented from the LaRC 8' Transonic Pressure Tunnel. The impact of incorrect assumptions related to hot wire sensitivities are highlighted. Velocity, density, total temperature, and mass flow results from three-element, two-element, and single-element probes are presented in rms and spectral formats. Based on these comparisons, great caution should be used when relying on flow quality information obtained utilizing hot wire techniques other than the three-element technique.

Jones, Gregory S.↗

Data acquisition for aeroelastic testing at the NASA Langley Transonic Dynamics Facility

Aeroelasticity is defined and different types of aeroelastic tests are described. The instrumentation and data acquisition requirements dictated by the time varying characteristics of aeroelastic phenomena are pointed out. Instrumentation needs for various types of tests are discussed. The hardware components and operational features of the real-time, digital-computer-controlled data acquisition system used to support testing at the Langley Transonic Dynamics Facility, which includes a major wind-tunnel, a helicopter-model hover facility, and two model setup and calibration laboratories are described.

Doggett, Robert V., Jr.↗

Thermoelectric Control Of Temperatures Of Pressure Sensors

Prototype controlled-temperature enclosure containing thermoelectric devices developed to house electronically scanned array of pressure sensors. Enclosure needed because (1) temperatures of transducers in sensors must be maintained at specified set point to ensure proper operation and calibration and (2) sensors sometimes used to measure pressure in hostile environments (wind tunnels in original application) that are hotter or colder than set point. Thus, depending on temperature of pressure-measurement environment, thermoelectric devices in enclosure used to heat or cool transducers to keep them at set point.

Burkett, Cecil G., Jr.↗

Drop C: The Drop-In, Ring-of-Power Heliostat (Final Report)

This report summarizes the work performed within the Drop-C: The Drop-In, Ring-of-Power Heliostat project. The Drop-C project aimed to develop a novel heliostat with an installed cost of $\$50$/m 2 ($\$2015$) which is a drastic cost reduction compared to the state-of-the-art. The resulting 27m 2 SunRing TM heliostat’s relative small size necessitates the parallel development of a wireless solar field network and a rapid calibration system. The SunRing heliostat is an evolution of the Ring-of-Power (ROP) design from Abengoa Solar LLC which had a reported installed cost of $114/m 2 . Cost savings relative to the ROP were sought by increasing the mirror area, improving the structural efficiency, a more accurate assessment of wind loads, and an improved assembly and installation procedure. The project spanned three Budget Periods (BP) where a digital heliostat was developed in BP1 using wind tunnel testing to define load conditions.

14 SOLAR ENERGY↗

Status of Mars Retropropulsion Testing in the Langley Unitary Plan Wind Tunnel

Future Mars human landings will be enabled by a powered descent phase starting at supersonic conditions, something which has never been done before on a Mars mission. Significant aerosciences challenges exist due to jet interactions between the retrorocket engine plumes, freestream flow, and vehicle that will affect the aerodynamic behavior during powered descent. Historically, wind tunnel tests have been used to study the interactions with inert gas exhaust simulants in place of rocket engines. On the computational side, flowfield simulations have been completed at full-scale conditions, but the available ground and flight data are not appropriate for calibrating computational uncertainties for aerodynamic interference on proposed Mars descent vehicles, due to insufficient data, dissimilar vehicle geometries, and disparate operating conditions. A wind tunnel test has been designed to begin addressing powered descent aerodynamics risks for large-scale human Mars entry concepts and to identify gaps in computational predictive capabilities. The test will be conducted in the NASA Langley Unitary Plan Wind Tunnel and is designed with improvements in model design and data products over past tests. The test campaign will be run using sub-scale model geometries derived from NASA powered descent reference vehicles: a blunt low lift-to-drag vehicle and a more slender geometry that generates higher unpowered lift. Both models have been fabricated and are ready for testing. The blunt model is equipped with the flexibility to examine the effects of nozzle pointing direction, number, location, size, and area ratio. The main measurements are heatshield aerodynamic interference forces and moments with a custom flow-through balance, discrete and distributed heatshield pressure, and high-speed flowfield visualization. This paper covers the test objectives, facility, models and instrumentation, and planned test matrix.

Mars↗

Status of Mars Retropropulsion Testing in the Langley Unitary Plan Wind Tunnel

Future Mars human landings will be enabled by a powered descent phase starting at supersonic conditions, something which has never been done before on a Mars mission. Significant aerosciences challenges exist due to jet interactions between the retrorocket engine plumes, freestream flow, and vehicle that will affect the aerodynamic behavior during powered descent. Historically, wind tunnel tests have been used to study the interactions with inert gas exhaust simulants in place of rocket engines. On the computational side, flowfield simulations have been completed at full-scale conditions, but the available ground and flight data are not appropriate for calibrating computational uncertainties for aerodynamic interference on proposed Mars descent vehicles, due to insufficient data, dissimilar vehicle geometries, and disparate operating conditions. A wind tunnel test has been designed to begin addressing powered descent aerodynamics risks for large-scale human Mars entry concepts and to identify gaps in computational predictive capabilities. The test will be conducted in the NASA Langley Unitary Plan Wind Tunnel and is designed with improvements in model design and data products over past tests. The test campaign will be run using sub-scale model geometries derived from NASA powered descent reference vehicles: a blunt low lift-to-drag vehicle and a more slender geometry that generates higher unpowered lift. Both models have been fabricated and are ready for testing. The blunt model is equipped with the flexibility to examine the effects of nozzle pointing direction, number, location, size, and area ratio. The main measurements are heatshield aerodynamic interference forces and moments with a custom flow-through balance, discrete and distributed heatshield pressure, and high-speed flowfield visualization. This paper covers the test objectives, facility, models and instrumentation, and planned test matrix.

Supersonic Retropropulsion↗

A distributed processing high data rate multiport wind-tunnel pressure measurement system

A multiport pressure measurement system has been developed for the high data rates and the in situ calibration of electronically scanned pressure (ESP) sensors. The system employs a stand-alone microcomputer, connected to a host computer, for data acquisition and preprocessing. The host computer provides several operational modes. Before each run the in situ calibration of each sensor is automatically performed. Using up to a maximum of 14 data acquisition and control units (DACU's), the system may be expanded from 16 to 10,752 pressure ports. Each DACU can make 20,000 measurements per second, average data, and perform statistical analyses before transferring data to the central unit. The system may be introduced into existing facilities and requires little user orientation.

Juanarena, D.↗

Statistical Calibration and Validation of a Homogeneous Ventilated Wall-Interference Correction Method for the National Transonic Facility

Wind tunnel experiments will continue to be a primary source of validation data for many types of mathematical and computational models in the aerospace industry. The increased emphasis on accuracy of data acquired from these facilities requires understanding of the uncertainty of not only the measurement data but also any correction applied to the data. One of the largest and most critical corrections made to these data is due to wall interference. In an effort to understand the accuracy and suitability of these corrections, a statistical validation process for wall interference correction methods has been developed. This process is based on the use of independent cases which, after correction, are expected to produce the same result. Comparison of these independent cases with respect to the uncertainty in the correction process establishes a domain of applicability based on the capability of the method to provide reasonable corrections with respect to customer accuracy requirements. The statistical validation method was applied to the version of the Transonic Wall Interference Correction System (TWICS) recently implemented in the National Transonic Facility at NASA Langley Research Center. The TWICS code generates corrections for solid and slotted wall interference in the model pitch plane based on boundary pressure measurements. Before validation could be performed on this method, it was necessary to calibrate the ventilated wall boundary condition parameters. Discrimination comparisons are used to determine the most representative of three linear boundary condition models which have historically been used to represent longitudinally slotted test section walls. Of the three linear boundary condition models implemented for ventilated walls, the general slotted wall model was the most representative of the data. The TWICS code using the calibrated general slotted wall model was found to be valid to within the process uncertainty for test section Mach numbers less than or equal to 0.60. The scatter among the mean corrected results of the bodies of revolution validation cases was within one count of drag on a typical transport aircraft configuration for Mach numbers at or below 0.80 and two counts of drag for Mach numbers at or below 0.90.

Walker, Eric Lee↗