An Experimental Investigation of Boundary-Layer Control for Drag Reduction of a Swept-Wing Section at Low Speed and High Reynolds Numbers
An investigation of laminar boundary-layer control by suction for purposes of drag reduction at low speed and high Reynolds numbers has been conducted in the Ames 12-Foot Pressure Wind Tunnel. The model was a 72.96-inch-chord wing panel, swept back 30 deg., which was installed between end plates to approximate a wing of infinite span. The airfoil section employed was a modified NACA 66-012 in the streamwise direction. Tests were limited to controlling the flow over only the upper surface of the model. Seventeen individually controllable suction chambers were provided below the surface to induce flow through 93 spanwise slots in the surface between the 0.0052- and 0.97-chord stations. Tests were made at angles of attack of 0 deg., +/- 1.0 deg., +/- 1.5 deg., and -2.0 deg. for Reynolds numbers from approximately 1.5 x 10(exp 6) to 4.0 x 10(exp 6) per foot. In general, essentially full-chord laminar flow was obtained for all conditions with small suction quantities. Minimum profile-drag coefficients of about 0.0005 to 0.0006 were obtained for the slotted surface at maximum values of the Reynolds number; these values include the Power required to induce suction as an equivalent drag.