At least 289 records · Page 16

Extraction of Dry Leaf Spectral Features from Reflectance Spectra of Green Vegetation

Reflectance spectra of green vegetation in the 1.4-2.5 micrometer region are dominated by liquid water absorptions. In this article, we describe the analysis of a set of reflectance spectra of green vegetation, dry vegetation, and liquid water measured in a laboratory using a nonlinear least squares spectral matching technique. We conclude that both the liquid water and the dry materials contribute to the reflectance spectra of green vegetation in the 1.0-2.5 micrometer region. Our matching of data acquired with the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) over two vegetated areas in Oregon Transect with a pure water spectrum also shows a residual absorption feature near 1.72 micrometers.

Gao, Bo-Cai↗

Removing Atmospheric Effects From AVIRIS Data for Surface Reflectance Retrievals

Analysis of high resolution imaging spectrometer data requires a thorough compensation for atmospheric absorption and scattering. A method for retrieving surface reflectances from spectral data collected by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is being developed. In this method, the integrated water vapor amount on a pixel by pixel basis is derived from the 0.94- and 1.14-micrometer water vapor features. The water vapor, carbon dioxide (CO2), oxygen (O2) and methane (CH4) transmission spectrum in the 0.4-2.5 micrometer region is calculated. The derived water vapor value and the solar and observational geometry are used in the spectral calculation. The AVIRIS spectrum is ratioed against the transmission spectrum to obtain the surface reflectance spectrum. Major mineral absorption features near 2.2 micrometer in retrieved reflectance spectra can be identified. Different vegetation absorption characteristics are observed. At present, the method is most useful for deriving surface reflectances from AVIRIS data measured on clear days with high visibilities. Atmospheric scattering effects will be included in our spectral calculations in the near future.

Gao, Bo-Cai↗

Sensing, Spectra and Scaling: What's in Store for Land Observations

Bill Pecora's 1960's vision of the future, using spacecraft-based sensors for mapping the environment and exploring for resources, is being implemented today. New technology has produced better sensors in space such as the Landsat Thematic Mapper (TM) and SPOT, and creative researchers are continuing to find new applications. However, with existing sensors, and those intended for launch in this century, the potential for extracting information from the land surface is far from being exploited. The most recent technology development is imaging spectrometry, the acquisition of images in hundreds of contiguous spectral bands, such that for any pixel a complete reflectance spectrum can be acquired. Experience with Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) has shown that, with proper attention paid to absolute calibration, it is possible to acquire apparent surface reflectance to 5% accuracy without any ground-based measurement. The data reduction incorporates in educated guess of the aerosol scattering, development of a precipitable water vapor map from the data and mapping of cirrus clouds in the 1.38 micrometer band. This is not possible with TM. The pixel size in images of the earth plays and important role in the type and quality of information that can be derived. Less understood is the coupling between spatial and spectral resolution in a sensor. Recent work has shown that in processing the data to derive the relative abundance of materials in a pixel, also known is unmixing, the pixel size is an important parameter. A variance in the relative abundance of materials among the pixels is necessary to be able to derive the endmembers or pure material constituent spectra. In most cases, the 1 km pixel size for the Earth Observing System Moderate Resolution Imaging Spectroradiometer (MODIS) instrument is too large to meet the variance criterion. A pointable high spatial and spectral resolution imaging spectrometer in orbit will be necessary to make the major next step in our understanding of the solid earth surface and its changing face.

Goetz, Alexander F. H.↗

Case Studies of Water Vapor and Surface Liquid Water from AVIRIS Data Measured Over Denver, CO and Death Valley, CA

High spatial resolution column atmospheric water vapor amounts and equivalent liquid water thicknesses of surface targets are retrieved from spectral data collected by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). The retrievals are made using a nonlinear least squares curve fitting technique. Two case studies from AVIRIS data acquired over Denver-Platteville area, Colorado and over Death Valley, California are presented. The column water vapor values derived from AVIRIS data over the Denver-Platteville area are compared with those obtained from radiosondes, ground level upward-looking microwave radiometers, and geostationary satellite measurements. The column water vapor image shows spatial variation patterns related to the passage of a weather front system. The column water vapor amounts derived from AVIRIS data over Death Valley decrease with increasing surface elevation. The derived liquid water image clearly shows surface drainage patterns.

Gao, B.-C.↗

AVIRIS Measurements of Spectral Reflectance Characteristics of Whitecaps

The spectral reflectance of oceanic whitecaps in the visible and near infrared was investigated using high-altitude, 20 m resolution Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) measurements off the Southern California coast. The whitecap effect on surface reflectance was expressed as a function of the difference between the reflectance of pixels contaminated by whitecaps and of adjacent pixels free of whitecaps. Whitecap reflectance was found to decrease substantially in the near infrared, by about 40% at 850 nm and 80% at 1,600 nm, in agreement with previous measurements in the coastal zone and the open ocean. The spectral dependence of whitecap reflectance appears to be fairly independent of environmental conditions, making it easy to take into account the resulting and significant effects in ocean color and aerosol remote sensing algorithms.

Frouin, Robert↗

Modeling and Prediction of Wildfire Hazard in Southern California, Integration of Models with Imaging Spectrometry

Large urban wildfires throughout southern California have caused billions of dollars of damage and significant loss of life over the last few decades. Rapid urban growth along the wildland interface, high fuel loads and a potential increase in the frequency of large fires due to climatic change suggest that the problem will worsen in the future. Improved fire spread prediction and reduced uncertainty in assessing fire hazard would be significant, both economically and socially. Current problems in the modeling of fire spread include the role of plant community differences, spatial heterogeneity in fuels and spatio-temporal changes in fuels. In this research, we evaluated the potential of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) and Airborne Synthetic Aperture Radar (AIRSAR) data for providing improved maps of wildfire fuel properties. Analysis concentrated in two areas of Southern California, the Santa Monica Mountains and Santa Barbara Front Range. Wildfire fuel information can be divided into four basic categories: fuel type, fuel load (live green and woody biomass), fuel moisture and fuel condition (live vs senesced fuels). To map fuel type, AVIRIS data were used to map vegetation species using Multiple Endmember Spectral Mixture Analysis (MESMA) and Binary Decision Trees. Green live biomass and canopy moisture were mapped using AVIRIS through analysis of the 980 nm liquid water absorption feature and compared to alternate measures of moisture and field measurements. Woody biomass was mapped using L and P band cross polarimetric data acquired in 1998 and 1999. Fuel condition was mapped using spectral mixture analysis to map green vegetation (green leaves), nonphotosynthetic vegetation (NPV; stems, wood and litter), shade and soil. Summaries describing the potential of hyperspectral and SAR data for fuel mapping are provided by Roberts et al. and Dennison et al. To utilize remotely sensed data to assess fire hazard, fuel-type maps were translated into standard fuel models accessible to the FARSITE fire spread simulator. The FARSITE model and BEHAVE are considered industry standards for fire behavior analysis. Anderson level fuels map, generated using a binary decision tree classifier are available for multiple dates in the Santa Monica Mountains and at least one date for Santa Barbara. Fuel maps that will fill in the areas between Santa Barbara and the Santa Monica Mountains study sites are in progress, as part of a NASA Regional Earth Science Application Center, the Southern California Wildfire Hazard Center. Species-level maps, were supplied to fire managing agencies (Los Angeles County Fire, California Department of Forestry). Research results were published extensively in the refereed and non-refereed literature. Educational outreach included funding of several graduate students, undergraduate intern training and an article featured in the California Alliance for Minorities Program (CAMP) Quarterly Journal.

Roberts, Dar A.↗

AVIRIS Reflectance Retrievals: UCSB Users Manual

The following write-up is designed to help students and researchers take Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) radiance data and retrieve surface reflectance. In the event that the software is not available, but a user has access to a reflectance product, this document is designed to provide a better understanding of how AVIRIS reflectance was retrieved. This guide assumes that the reader has both a basic understanding of the UNIX computing environment, and that of spectroscopy. Knowledge of the Interactive Data Language (IDL) and the Environment for Visualizing Images (ENVI) is helpful. This is a working document, and many of the fine details described in the following pages have been previously undocumented. After having read this document the reader should be able to process AVIRIS to reflectance, provided access to all of the code is possible. The AVIRIS radiance data itself is pre-processed at the Jet Propulsion Laboratory (JPL) in Pasadena, California. The first section of this paper describes how to read data from tape and byte-swap the data. Section 2 describes the procedure in preparing support files before running the 'h2o' suite of programs. Section 3 describes the four programs used in the process, h2olut9.f, h2ospl9.f, vlsfit9.f and rfl9.f.

Roberts, Dar A.↗

AVIRIS Land-Surface Mapping in Support of the Boreal Ecosystem-Atmosphere Study (BOREAS)

A key scientific objective of the original Boreal Ecosystem-Atmospheric Study (BOREAS) field campaign (1993-1996) was to obtain the baseline data required for modeling and predicting fluxes of energy, mass, and trace gases in the boreal forest biome. These data sets are necessary to determine the sensitivity of the boreal forest biome to potential climatic changes and potential biophysical feedbacks on climate. A considerable volume of remotely-sensed and supporting field data were acquired by numerous researchers to meet this objective. By design, remote sensing and modeling were considered critical components for scaling efforts, extending point measurements from flux towers and field sites over larger spatial and longer temporal scales. A major focus of the BOREAS follow-on program is concerned with integrating the diverse remotely sensed and ground-based data sets to address specific questions such as carbon dynamics at local to regional scales. The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) has the potential of contributing to BOREAS through: (1) accurate retrieved apparent surface reflectance; (2) improved landcover classification; and (3) direct assessment of biochemical/biophysical information such as canopy liquid water and chlorophyll concentration through pigment fits. In this paper, we present initial products for major flux tower sites including: (1) surface reflectance of dominant cover types; (2) a land-cover classification developed using spectral mixture analysis (SMA) and Multiple Endmember Spectral Mixture Analysis (MESMA); and (3) liquid water maps. Our goal is to compare these land-cover maps to existing maps and to incorporate AVIRIS image products into models of photosynthetic flux.

Roberts, Dar A.↗

Multi-Sensor Characterization of the Boreal Forest: Initial Findings

Results are presented in an initial apriori knowledge approach toward using complementary multi-sensor multi-temporal imagery in characterizing vegetated landscapes over a site in the Boreal Ecosystem-Atmosphere Study (BOREAS). Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) and Airborne Synthetic Aperture Radar (AIRSAR) data were segmented using multiple endmember spectral mixture analysis and binary decision tree approaches. Individual date/sensor land cover maps had overall accuracies between 55.0% - 69.8%. The best eight land cover layers from all dates and sensors correctly characterized 79.3% of the cover types. An overlay approach was used to create a final land cover map. An overall accuracy of 71.3% was achieved in this multi-sensor approach, a 1.5% improvement over our most accurate single scene technique, but 8% less than the original input. Black spruce was evaluated to be particularly undermapped in the final map possibly because it was also contained within jack pine and muskeg land coverages.

Reith, Ernest↗

High Altitude Measurements of Radiance at High Spectral and Spatial Resolution for SIMBIOS Sensor Calibration, Validation, and Intercomparisons

The successful combination of data from different ocean color sensors depends on the correct interpretation of signal from each of these sensors. Ideally, the sensor measured signals are calibrated to geophysical units of spectral radiance, and sensor artifacts are removed and corrected. The calibration process resamples the signal into a common radiometric data space so that subsequent ocean color algorithms that are applied to the data are based on physical processes and are inherently sensor independent. The objective of this project is to calibrate and validate the on-orbit radiometric characteristics of Sea-Viewing Wide Field-of-view Sensor (SeaWiFS) with underflights of NASA's calibrated Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). This objective is feasible because AVIRIS measures the same spectral range as SeaWIFS at higher spectral resolution. In addition to satellite sensor underflights, the AVIRIS project has supported comparison and analysis of the radiometric calibration standards used for AVIRIS and SeaWIFS. To date, both the OCTS and SeaWIFS satellite sensors have been underflown by AVIRIS with matching spectral, spatial, geometric, radiometric, and temporal domains. The calibration and validation objective of this project is pursued for the following reasons: (1) Calibration is essential for the quantitative use of SeaWIFS and other SIMBIOS (Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies) sensor data; (2) Calibration in the laboratory of spaceborne sensors is challenging; (3) Satellite sensors are subjected aging on the ground and to trauma during launch; (4) The Earth orbit environment is significantly different than the laboratory calibration environment; (5) Through years of effort AVIRIS has been demonstrated to be well calibrated; and (6) AVIRIS can match the spectral and spatial observation characteristics near the top of the atmosphere at the time of SeaWIFS measurements.

Green, Robert O.↗

Proceedings of the Tenth JPL Airborne Earth Science Workshop

This publication contains the proceedings of the AVIRIS Earth Science and Applications Workshop - a forum held to report science research and applications results with spectral images measured by the NASA Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). These papers were presented at the Jet Propulsion Laboratory on February 27 and 28 and March 1 and 2, 2001.

Green, Robert O.↗

Calibration and Vegetation Field Spectra Collection for the 2000 AVIRIS Hawaii Deployment

As part of the April 2000 Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) Hawaii deployment, two researchers from the University of California, Santa Barbara, were sent to Hawaii to collect supporting field data. The primary goal of the fieldwork was to obtain spectra of bright targets to be used for retrieving surface reflectance from AVIRIS imagery. Secondary goals included recording the spectra of dominant vegetation, marking the position of homogeneous land cover for use as potential image endmembers (PIEs), and recording firsthand impressions of cover types. Primary and secondary goals were met. Spectra were recorded for 12 calibration targets on 5 islands and spectra were obtained for 61 vegetation species. Twenty PIEs were located, and video was used to document cover at 56 locations.

Dennison, Philip E.↗

Nutrient Stress Detection in Corn, Using Neural Networks and AVIRIS Hyperspectral Imagery

The US Department of Agriculture (USDA) Agricultural Research Service (ARS) Variable Rate (VRAT) Nitrogen Application site in Shelton, Nebraska, represents a well-documented, corn-growing quarter section. The USDA VRAT site is used to systematically study nutrient stress in corn by varying sub-plot application of fertilizer. The field has four replicates of five blocks that vary by nitrogen treatment from 0-kg/ha to 200-kg/ha in 50-kg/ha increments. The treatment blocks are set out in a randomized, complete block design. Typically, the VRAT is planted in a ridge till, monoculture corn and is watered by a central pivot irrigation system on a three-day period. Since water stress can increase spectral reflectance from corn leaves, it is important that the N-application plots be adequately watered so that only nutrient-related stress will predominate. A figure shows imagery of the USDA VRAT site with the fertilizer amounts for each block shown. Low-altitude Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) hyperspectral imagery was acquired over the Shelton, Nebraska, VRAT site on July 22, 1999. The overflight produced 3-meter pixels with 224 spectral bands. Ground personnel supported the mission with measurements at the time of the overflight. The image data was pre-processed at JPL before being sent out to an investigator. The data arrived radiometrically corrected, allowing ready application of an atmospheric correction procedure. The Atmosphere Removal Program (ATREM) was used to perform an atmospheric correction. The AVIRIS imagery after ATREM correction was output as relative reflectance. This relative reflectance file was scaled by an empirical line procedure to provide reflectances that matched closely those measured in the field.

Estep, Lee↗

Estimating Expressed Temperature and Fractional Area of Hot Lava at the Kilauea Vent with AVIRIS Spectral Measurements

Imaging spectroscopy offers a framework based in physics and chemistry for scientific investigation of a wide range of phenomena of interest in the Earth environment. In the scientific discipline of volcanology knowledge of lava temperature and distribution at the surface provides insight into the volcano status and subsurface processes. A remote sensing strategy to measure surface lava temperatures and distribution would support volcanology research. Hot targets such as molten lava emit spectral radiance as a function of temperature. A figure shows a series of Planck functions calculated radiance spectra for hot targets at different temperatures. A maximum Lambertian solar reflected radiance spectrum is shown as well. While similar in form, each hot target spectrum has a unique spectral shape and is distinct from the solar reflected radiance spectrum. Based on this temperature-dependent signature, imaging spectroscopy provides an innovative approach for the remote-sensing-based measurement of lava temperature. A natural site for investigation of the measurement of lava temperature is the Big Island of Hawaii where molten lava from the Kilauea vent is present at the surface. In the past, Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data sets have been used for the analysis of hot volcanic targets and hot burning fires. The research presented here builds upon and extends this earlier work. The year 2000 Hawaii AVIRIS data set has been analyzed to derive lava temperatures taking into account factors of fractional fill, solar reflected radiance, and atmospheric attenuation of the surface emitted radiance. The measurements, analyses, and current results for this research are presented here.

Green, Robert O.↗

Measuring the Spectral Expression of Carbon Dioxide in the Solar Reflected Spectrum with AVIRIS

Carbon dioxide is a low-concentration, but important, component of the Earth's atmosphere. This gas absorbs electromagnetic radiation (EMR) in several regions of the spectrum. Absorption of energy by carbon dioxide adds heat to the atmosphere. In the world today, the burning of fossil fuels and other anthropogenic processes adds carbon dioxide to the atmosphere. Other natural processes in the Earth's system both add and remove carbon dioxide. Overall, measurements of atmospheric carbon dioxide at selected sites around the globe show an increased carbon dioxide concentration in the atmosphere. A figure shows the measured carbon dioxide from Mauna Loa, Hawaii, from 1958 to 2000. Overall, the concentration has increased from 315 to 365 ppm at this site over this period. (There is also a yearly cycle to the concentration that is timed with and hypothesized to be related to the vegetation growing season in the Northern Hemisphere.) The overall expected effect of this increase of atmospheric carbon dioxide is trapping of heat in the atmosphere and global warming. While this overall relationship between carbon dioxide and global warming seems straightforward, many of the specific details relating to regional and local sources and sinks and gradients of carbon dioxide are not well understood. A remote sensing capability to measure carbon dioxide could provide important inputs for scientific research to better understand the distribution and change in atmospheric carbon dioxide at detailed spatial and temporal levels. In pursuit of this remote sensing of carbon dioxide objective, this paper analyzes the expression of carbon dioxide in the spectral range measured by the Airborne Visible/Infrared Imagery Spectrometer (AVIRIS). Based on these analyses, a spectral-fitting algorithm that uses AVIRIS measured spectra and MODTRAN radiative-transfer code modeled spectra to derive total column carbon dioxide abundance has been developed. This algorithm has been applied to an AVIRIS data set acquired over Pasadena, California, in 1999 and a data set acquired over the Pacific Ocean near Hawaii in 2000 with promising results. This is ongoing research; the current initial analyses, measurements, and results are reported in this paper.

Green, Robert O.↗

Exploring a Black Body Source as an Absolute Radiometric Calibration Standard and Comparison with a NIST Traced Lamp Standard

Radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is required for the scientific research and application objectives pursued with the spectroscopic measurements. Specifically calibration is required for: inter-comparison of AVIRIS data measured at different locations and at different times; analysis of AVIRIS data with data measured by other instruments; and analysis of AVIRIS data in conjunction with computer models. The primary effect of radiometric calibration is conversion of AVIRIS instrument response values (digitized numbers, or DN) to units of absolute radiance. For example, a figure shows the instrument response spectrum measured by AVIRIS over a portion of Rogers Dry Lake, California, and another figure shows the same spectrum calibrated to radiance. Only the calibrated spectrum may be quantitatively analyzed for science research and application objectives. Since the initial development of the AVIRIS instrument-radiometric calibration has been based upon a 1000-W irradiance lamp with a calibration traced to the National Institute of Standards and Technology (NIST). There are several advantages to this irradiance-lamp calibration approach. First, the considerable effort of NIST backs up the calibration. Second, by changing the distance to the lamp, the output can closely span the radiance levels measured by AVIRIS. Third, this type of standard is widely used. Fourth, these calibrated lamps are comparatively inexpensive. Conversely, there are several disadvantages to this approach as well. First, the lamp is not a primary standard. Second, the lamp output characteristics may change in an unknown manner through time. Third, it is difficult to assess, constrain, or improve the calibration uncertainty delivered with the lamp. In an attempt to explore the effect and potentially address some of these disadvantages a set of analyses and measurements comparing an irradiance lamp with a black-body source have been completed. This research is ongoing, and the current set of measurements, analyses, and results are presented in this paper.

Green, Robert O.↗

AVIRIS Inflight Calibration Experiments, Analysis, and Results in 2000

The NASA Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) measures spectra from 370 to 2500 nm with nominally 10-nm sampling and resolution. The spectra are acquired as images with an 11 km width and up to 800 km length from the ER-2 platform or 2.1 km width and 160 km length from the Twin Otter platform. AVIRIS measurements are used for a range of Earth science research and application objectives. The molecular absorption and particle scattering properties expressed in the calibrated AVIRIS measurements are used. For both science research and application objectives, calibration of the AVIRIS spectra is required to produce useful results. Each year prior to the flight season AVIRIS is calibrated in the laboratory. However, the temperature, pressure, vibration, and observational geometry, as well as mechanical, electrical, and operational interfaces of the laboratory are different than the environment on board the airborne platform. To validate the calibration of AVIRIS in the flight environment, an inflight calibration experiment is orchestrated at the beginning of each flight season. In most years additional inflight calibration experiments occur towards the middle and end of the flight season as well. For an inflight calibration experiment, AVIRIS acquires airborne data over a designated calibration target. In concert with the airborne data acquisition, surface and atmospheric properties at the calibration target are measured in situ. These in situ measurements are used to constrain a radiative transfer code and predict the radiance incident at the AVIRIS instrument from the calibration target. This prediction is compared with the AVIRIS-measured radiance to validate the calibration of AVIRIS in the flight environment. Additional properties (such as the AVIRIS inflight measurement precision) are determined as well. This paper presents measurements, analyses, and results from the inflight calibration experiment held on the dry lake bed surface of Rogers Dry Lake, California, on June 5, 2000.

Green, Robert O.↗

Geologic Validation of EO-1 Hyperion using AVIRIS

Over the last few years, the field of imaging spectrometry has grown rapidly as new instruments and analysis techniques have been developed. The launch of Hyperion as part of NASA's EO-1 program represents a significant landmark in the progression of the technology; the first spaceborne imaging spectrometry system. AIG, in cooperation with CSIRO, is evaluating, validating, and demonstrating use of EO-1 Hyperion hyperspectral data for geologic applications. The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) plays a pivotal role in this effort. This manuscript describes the geologic test sites being used and progress on preparing 'ground truth' for anticipated Hyperion data collects using AVIRIS data. Preliminary findings are extrapolated to predict the effect of instrument characteristics and performance on geologic mapping using Hyperion.

Kruse, F. A.↗