Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VOLUME”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Network-Scale Ubiquitous Volume Estimation Using Tree-Based Ensemble Learning Methods

Currently ubiquitous volume data for roadway networks remains the key missing dimension in traffic operations. Most volume data are average annual daily traffic (AADT) measures derived from the Highway Performance Monitoring System (HPMS). Although methods to factor the AADT to hourly averages for typical day of week exist, actual volume data is limited to a sparse collection of locations in which volumes are continuously recorded. This paper/poster explores the use of state-of-art machine learning techniques to estimate accurate volume measures that span the highway network providing ubiquitous coverage in space, and point-in-time measures for a specific date and time. Three tree-based ensemble learning models, random forest (RF), gradient boost machine (GBM), and extreme gradient boost (XGBoost), were tested for volume estimation by learning from combined dataset of commercial probe data provided by TomTom, the FHWA's Travel Monitoring Analysis System (TMAS) data, and other infrastructure attributes such as number of lanes, speed limit, and weather. The methods were tested on major corridors and freeways in the metropolitan area of Denver. All three machine learning methods were able to provide hourly volume estimates 24 hours a day, 7 days a week, and 365 days a year with around 18% mean absolute error to true volume and about 5% of error with respect to roadway capacity. The low error measures allow the potential application by transportation agencies.

33 ADVANCED PROPULSION SYSTEMS↗

Implementation of Increased Salt and Decreased Sludge Volumes in the Defense Waste Processing Facility - 19597

The Savannah River Site (SRS) Liquid Waste System (LWS) safely stores and treats high-level radioactive waste. The LWS consists of 51 waste storage tanks (eight of which are operationally closed and filled with grout), waste evaporators, treatment facilities, and solidification facilities such as the Defense Waste Processing Facility (DWPF) and Saltstone Production Facility (SPF). The disposition of high-level waste (HLW) into a glass waste form poured into canisters at the DWPF began in 1996. DWPF processed a sludge only flowsheet until 2008 when the Actinide Removal Process (ARP) and Modular Caustic Side Solvent Extraction Unit (MCU) began treating the salt waste from the underground liquid storage tanks by striking with monosodium titanate (MST) to remove actinides, when necessary to meet downstream acceptance criteria, and removing the MST and entrained sludge solids (SS) by filtration before using an organic solvent to strip the cesium from the salt, creating two new concentrated HLW streams. This change caused the DWPF to begin processing under both a sludge-only and a coupled operations flowsheet where salt streams would only be added when available. This strategy allows for continuous glass canister production at DWPF. Recently, DWPF completed a 10-month melter replacement in December 2017 and the Concentrate, Storage, and Transfer Facility (CSTF) has completed repairs to the 3H Evaporator system. These facility outages have caused delays in preparing the next batch of sludge feed for DWPF. Concurrent with these facility outages, the Salt Waste Processing Facility (SWPF) has been undergoing system testing and commissioning, working toward startup. SWPF is designed to process salt waste in the same manner as ARP/MCU, but with much higher throughput volumes produced per unit time. In order to process the SWPF salt streams efficiently, DWPF will implement a coupled operation only flowsheet. Based on the facility outages mentioned above, efforts have been made to identify strategies to minimize sludge volumes and maximize salt volumes in the DWPF until the next sludge batch is ready for processing in DWPF. Savannah River Remediation (SRR) recently performed an evaluation that examines the effects of reducing the volume of sludge and maximizing the addition of the cesium-rich concentrated salt solution in each Sludge Receipt and Adjustment Tank (SRAT) batch in order to extend the existing sludge batch as long as possible until the next sludge batch is ready. These effects include a reduction of weight percent solids in the DWPF processing vessels, an increase in cycle time, a new canister heat generation value that remains within regulatory limits, and higher gamma source that remains within bulk facility gamma shielding. Balancing the above parameters resulted in a small reduction of sludge volume per SRAT batch under SWPF operation and maximizing the salt volumes for both ARP/MCU and SWPF operation. This slight reduction in sludge volume and increase in salt volumes allows SRR to mitigate some of the schedule impact incurred by the facility outages. This strategy was evaluated for both ARP/MCU and SWPF operation. This strategy has been successfully implemented under ARP/MCU operation using small step changes in the current process. This paper provides an overview of the evaluation performed for DWPF with ARP/MCU and DWPF with SWPF operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimization-based mesh correction with volume and convexity constraints

Here, we consider the problem of finding a mesh such that 1) it is the closest, with respect to a suitable metric, to a given source mesh having the same connectivity, and 2) the volumes of its cells match a set of prescribed positive values that are not necessarily equal to the cell volumes in the source mesh. Also, this volume correction problem arises in important simulation contexts, such as satisfying a discrete geometric conservation law and solving transport equations by incremental remapping or similar semi-Lagrangian transport schemes. In this paper we formulate volume correction as a constrained optimization problem in which the distance to the source mesh defines an optimization objective, while the prescribed cell volumes, mesh validity and/or cell convexity specify the constraints. We solve this problem numerically using a sequential quadratic programming (SQP) method whose performance scales with the mesh size. To achieve scalable performance we develop a specialized multigrid-based preconditioner for optimality systems that arise in the application of the SQP method to the volume correction problem. Numerical examples illustrate the importance of volume correction, and showcase the accuracy, robustness and scalability of our approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Increasing the Measured Effective Quantum Volume with Zero Noise Extrapolation

Quantum volume is a full-stack benchmark for near-term quantum computers. It quantifies the largest size of a square circuit which can be executed on the target device with reasonable fidelity. Error mitigation is a set of techniques intended to remove the effects of noise present in the computation of noisy quantum computers when computing an expectation value of interest. Effective quantum volume is a proposed metric that applies error mitigation to the quantum volume protocol to evaluate the effectiveness not only of the target device but also of the error mitigation algorithm. Digital zero-noise extrapolation is an error mitigation technique that estimates the noiseless expectation value using circuit folding to amplify errors by known scale factors and then extrapolating computed expectation values to the zero-noise limit. Here we demonstrate that zero-noise extrapolation, with global and local unitary folding with fractional scale factors, in conjunction with dynamical decoupling, can increase the effective quantum volume over the vendor-measured quantum volume. Specifically, we measure the effective quantum volume of four IBM Quantum superconducting processor units, obtaining values that are larger than the vendor-measured quantum volume on each device. This is the first such increase reported.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fundamentals on dependence of volume on pressure and temperature

The common wisdom that volume decreases with pressure and increases with temperature is analyzed in terms of Hillert nonequilibrium thermodynamics in the present work. It is shown that the derivative of volume to pressure in a stable system is always negative, i.e., volume decreases with the increase of pressure, when all other natural variables of the system are kept constant. This originates from the stability requirement that the conjugate variables, such as volume and negative pressure, must change in the same direction in a stable system. Consequently, since volume and temperature are not conjugate variables, they do not have to change in the same direction and thus do change in opposite directions in both natural and man-made systems. It is shown that the decrease of volume with the increase of temperature, commonly referred as negative thermal expansion (NTE) in the literature, originates from the statistical competitions of configurations in the system when the volumes of metastable configurations are smaller than that of the ground-state configuration. As a result, it is demonstrated that the zentropy theory can concisely explain and accurately predict NTE based on the density functional theory without fitting parameters.

36 MATERIALS SCIENCE↗

Quantifying the atomistic free-volume morphology of materials with graph theory

Here, we introduce a new computational methodology for the identification and characterization of free volume within/around atomistic configurations. This scheme employs a three-stage workflow, by which spheres are iteratively grown inside of voxels, and ultimately converted to planar graphs, which are then characterized via a graph-based order parameter. Our approach is computationally efficient, physically intuitive, and universally transferable to any material system. Validation of our methodology is performed on several sets of materials problems: (1) classification of unique free volumes in various crystal phases, (2) autonomous detection and classification of complex surface defects during epitaxial growth simulations, (3) characterization of free volume defects in metals/alloys, and (4) quantification of the spatio-temporal behavior of nano-scale free volume morphologies as a function of both temperature and free-volume size. Our method accurately identifies and characterizes unique free volumes over a multitude of systems and length scales, indicating its potential for future use in understanding the relationship between free volume morphology and material properties under both static and dynamic conditions.

36 MATERIALS SCIENCE↗

Tumor Volume Is a Prognostic Factor in Non-Small-Cell Lung Cancer Treated With Chemoradiotherapy

Purpose: To investigate whether primary tumor and nodal volumes defined on radiotherapy planning scans are correlated with outcome (survival and recurrence) after combined-modality treatment. Methods and Materials: A retrospective review of patients with Stage III non-small-cell lung cancer treated with chemoradiation at Brigham and Women's Hospital/Dana-Farber Cancer Institute from 2000 to 2006 was performed. Tumor and nodal volume measurements, as computed by Eclipse (Varian, Palo Alto, CA), were used as independent variables, along with existing clinical factors, in univariate and multivariate analyses for association with outcomes. Results: For patients treated with definitive chemoradiotherapy, both nodal volume (hazard ratio [HR], 1.09; p < 0.01) and tumor volume (HR, 1.03; p < 0.01) were associated with overall survival on multivariate analysis. Both nodal volume (HR, 1.10; p < 0.01) and tumor volume (HR, 1.04; p < 0.01) were also associated with local control but not distant metastases. Conclusions: In addition to traditional surgical staging variables, disease burden, measured by primary tumor and nodal metastases volume, provides information that may be helpful in determining prognosis and identifying groups of patients for which more aggressive local therapy is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A new method to estimate the atomic volume of ternary intermetallic compounds

The atomic volume of an A{sub x}B{sub y}C{sub z} ternary intermetallic compound can be calculated starting from volumes of some proper A-B, A-C and B-C binary phases. The three methods by Colinet, Muggianu and Kohler, originally used to estimate thermodynamic quantities, and a new method here proposed, were tested to derive volume data in eight systems containing 91 ternary phases with the known structure. The comparison between experimental and calculated volume values shows the best agreement both for the Kohler method and for the new proposed procedure. -- Graphical abstract: Synopsys: the volume of a ternary intermetallic compound can be calculated starting from volumes of some binary phases, selected by the methods of Colinet, Muggianu, Kohler and a new method proposed here. The so obtained values are compared with the experimental ones for eight ternary systems. Display Omitted Research highlights: {yields} The application of some thermodinamic methods to a crystallochemical problem. {yields} The prevision of the average atomic volume of ternary intermetallic phases. {yields} The proposal of a new procedure to select the proper starting set of binary phases.

36 MATERIALS SCIENCE↗

Factors Affecting Prostate Volume Estimation in Computed Tomography Images

The aim of this study was to investigate how apex-localizing methods and the computed tomography (CT) slice thickness affected the CT-based prostate volume estimation. Twenty-eight volunteers underwent evaluations of prostate volume by CT, where the contour segmentations were performed by three observers. The bottom of ischial tuberosities (ITs) and the bulb of the penis were used as reference positions to locate the apex, and the distances to the apex were recorded as 1.3 and 2.0 cm, respectively. Interobserver variations to locate ITs and the bulb of the penis were, on average, 0.10 cm (range 0.03-0.38 cm) and 0.30 cm (range 0.00-0.98 cm), respectively. The range of CT slice thickness varied from 0.08-0.48 cm and was adopted to examine the influence of the variation on volume estimation. The volume deviation from the reference case (0.08 cm), which increases in tandem with the slice thickness, was within {+-} 3 cm{sup 3}, regardless of the adopted apex-locating reference positions. In addition, the maximum error of apex identification was 1.5 times of slice thickness. Finally, based on the precise CT films and the methods of apex identification, there were strong positive correlation coefficients for the estimated prostate volume by CT and the transabdominal ultrasonography, as found in the present study (r > 0.87; p < 0.0001), and this was confirmed by Bland-Altman analysis. These results will help to identify factors that affect prostate volume calculation and to contribute to the improved estimation of the prostate volume based on CT images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging

AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, P<0.05). CONCLUSION: Apically rotated measurement methods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

Evaluation Studies↗

Conjunction Assessment Screening Volume Sizing and Event Filtering in Light of Natural Conjunction Event Development Behaviors

Conjunction Assessment screening volumes used in the protection of NASA satellites are constructed as geometric volumes about these satellites, of a size expected to capture a certain percentage of the serious conjunction events by a certain time before closest approach. However, the analyses that established these sizes were grounded on covariance-based projections rather than empirical screening results, did not tailor the volume sizes to ensure operational actionability of those results, and did not consider the adjunct ability to produce data that could provide prevenient assistance for maneuver planning. The present study effort seeks to reconsider these questions based on a six-month dataset of empirical screening results using an extremely large screening volume. The results, pursued here for a highly-populated orbit regime near 700 km altitude, identify theoretical limits of screening volume performance, explore volume configuration to facilitate both maneuver remediation planning as well as basic asset protection, and recommend sizing principles that maximize volume performance while minimizing the capture of "chaff" conjunctions that are unlikely ever to become serious events.

screening volume↗

Formalized Reasoning of Operational Volumes for Wildland Fire Fighting

This work is focused on the formalized reasoning of operational volumes as it relates to the current and future technologies developed by NASA to aid in wildfire fighting operations. One such technology is the unmanned aircraft system pilot kit (UASP-kit) developed by the Scalable Traffic Management for Emergency Response Operations (STEReO) project at NASA, which is used to increase situation awareness for a ground operator in the field. The UASP-kit utilizes operational volumes which represent mission areas and alerting volumes, to alert when another aircraft is within one of these volumes from received ADS-B data. This work is focused on developing a rigorous foundation for the concept of operational volumes for modeling and prototyping operations in such a tool as the UASP-kit. This includes establishing a class of algorithms to detect when an object is in an operational volume, and when an operational volume is intersecting or contained within another. Additionally, this work is focused on providing rigorous proof in an interactive theorem prover that the algorithms work as intended. Scenarios are presented that model current UASP-kit operations and extend past the current capabilities of the technology to modeling more complex scenarios such as mission planning.

Operational Volumes↗

Formalized Reasoning of Operational Volumes for Wildland Fire Fighting

This work is focused on the formalized reasoning of operational volumes as it relates to the current and future technologies developed by NASA to aid in wildland firefighting operations. One such technology is the Unmanned Aircraft System Pilot Kit (UASP-kit) developed by the Scalable Traffic Management for Emergency Response Operations (STEReO) project at NASA, which is used to increase situational awareness for a ground operator in the field. The UASP-kit utilizes operational volumes to represent mission areas and alerting volumes; these volumes, in combinations with ADS-B data, can then be used to alert the ground operator when another aircraft has entered one of these areas. This work presents a rigorous foundation for the concept of operational volumes for modeling and prototyping operations in such a tool as the UASP-kit. This includes establishing a class of algorithms to detect when an object is in an operational volume, and when one operational volume intersects or is contained in another. Additionally, this work provides rigorous proof that the algorithms work as intended. Scenarios are presented that model current UASP-kit operations and extend past the current capabilities of the technology to modeling more complex scenarios such as mission planning.

Operational Volumes↗

Estimating Highway Volumes Using Vehicle Probe Data - Proof of Concept: Preprint

This paper examines the feasibility of using sampled commercial probe data in combination with validated continuous counter data to accurately estimate vehicle volume across the entire roadway network, for any hour during the year. Currently either real time or archived volume data for roadways at specific times are extremely sparse. Most volume data are average annual daily traffic (AADT) measures derived from the Highway Performance Monitoring System (HPMS). Although methods to factor the AADT to hourly averages for typical day of week exist, actual volume data is limited to a sparse collection of locations in which volumes are continuously recorded. This paper explores the use of commercial probe data to generate accurate volume measures that span the highway network providing ubiquitous coverage in space, and specific point-in-time measures for a specific date and time. The paper examines the need for the data, fundamental accuracy limitations based on a basic statistical model that take into account the sampling nature of probe data, and early results from a proof of concept exercise revealing the potential of probe type data calibrated with public continuous count data to meet end user expectations in terms of accuracy of volume estimates.

25 ENERGY STORAGE↗

A comparison of segmented abdominopelvic fluid volumes with conventional CT signs of abdominal compartment syndrome in a trauma population

Purpose: To compare the utility of abdominopelvic fluid volume measurements with established computed tomography signs for refractory post-traumatic abdominal compartment syndrome. Methods: This retrospective observational cohort study included 64 consecutive adult trauma patients with preoperative CT and diagnosis of refractory abdominal compartment syndrome requiring decompressive laparotomy at a level I trauma referral center between 2004 and 2014. We hypothesized that abdominal fluid volume measurements would be more predictive of the need for early laparotomy than previously described conventional CT signs of refractory ACS. Abdominopelvic fluid volumes were determined quantitatively using semi-automated segmentation software. The following conventional imaging parameters were recorded: abdominal anteroposterior:transverse ratio (round belly sign); infrahepatic vena cava diameter; distal abdominal aortic diameter; largest single small bowel wall diameter; hydronephrosis, inguinal herniation; and mesenteric and body wall edema. For outcome analysis, patients were stratified into two groups: those who underwent early (< 24 h) and late (≥ 24 h) decompressive laparotomy following CT. Correlation analysis, comparison of means, and multivariate logistic regression were performed. Results: Abdominal fluid volumes (p = 0.001) and anteroposterior:transverse ratio (p = 0.009) were increased and inferior vena cava diameter (p = 0.009) was decreased in the early decompressive laparotomy group. Multivariate analysis including conventional CT variables, fluid volumes, and laboratory values revealed abdominal fluid volumes (p = 0.012; Δ in log odds of 1.002/mL) as the only independent predictor of early decompressive laparotomy. Conclusions: Segmented abdominopelvic free fluid volumes had greater predictive utility for decision to perform early decompressive laparotomy than previously described ACS-related CT signs in trauma patients who developed refractory abdominal compartment syndrome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Clinical Experience With the Strut-Adjusted Volume Implant (SAVI) Breast Brachytherapy Device for Accelerated Partial-Breast Irradiation (APBI): First 100 Patients With More Than 1 Year of Follow-Up

Purpose: The Strut-Adjusted Volume Implant (SAVI; Cianna Medical, Aliso Viejo, CA) is a multichannel single-entry brachytherapy device designed to allow dose modulation to minimize normal tissue dose while simultaneously maximizing target coverage. This is the first report on the initial 102 patients with nearly 2 years of median follow-up. Methods and Materials: One hundred two patients were treated at two institutions. Data were collected on eligibility and dosimetry and followed for toxicity and recurrence. Results: The median follow-up is 21 months. Overall dosimetry is outstanding (median percent of target volume receiving 90% of the prescription dose was 95.9%, volume of target receiving 150% of the prescription dose was 27.8 mL, and volume of target receiving 200% of the prescription dose was 14.0 cm{sup 3}). No devices were pulled prior to treatment completion. For patients with a skin bridge of less than 7 mm, the maximum median skin dose was 280 cGy (median percent of target volume receiving 90% of the prescription dose was 95.2%, volume of target receiving 150% of the prescription dose was 25.8 cm{sup 3} and volume of target receiving 200% of the prescription dose was 12.7 mL). For patients with both chest wall and skin of less than 7 mm, the maximum median lung dose was 205 cGy with simultaneous skin dose of 272 cGy. The rate of telangiectasia was 1.9%. Grade 1 hyperpigmentation developed in 10 patients (9.8%) and Grade 2 fibrosis in 2 patients (1.9%). There were 2 symptomatic seromas and 2 cases of asymptomatic fat necrosis (1.9%). Of the patients, 27% were not eligible for MammoSite balloon brachytherapy (Hologic, Inc., Marlborough, MA) and 5% were not eligible for any balloon brachytherapy. The recurrence rate was 1%. Conclusions: The SAVI appears to safely allow an increase in eligibility for APBI over balloon brachytherapy or three-dimensional conformal radiation, highlighting the outstanding device flexibility to maximize the target dose and minimize the normal tissue dose. The device was well tolerated by patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Therapy After Breast-Conserving Surgery: Does Hospital Surgical Volume Matter? A Population-Based Study in Taiwan

Purpose: To examine the association between hospital surgical volume and the use of radiation therapy (RT) after breast-conserving surgery (BCS) in Taiwan. Methods and Materials: We used claims data from the National Health Insurance program in Taiwan (1997-2005) in this retrospective population-based study. We identified patients with breast cancer, receipt of BCS, use of radiation, and the factors that could potentially associated with the use of RT from enrollment records, and the ICD-9 and billing codes in claims. We conducted logistic regression to examine factors associated with RT use after BCS, and performed subgroup analyses to examine whether the association differs by medical center status or hospital volumes. Results: Among 5,094 patients with newly diagnosed invasive breast cancer who underwent BCS, the rate of RT was significantly lower in low-volume hospitals (74% vs. 82%, p < 0.01). Patients treated in low-volume hospitals were less likely to receive RT after BCS (odds ratio = 0.72, 95% confidence interval = 0.62-0.83). In addition, patients treated after the implementation of the voluntary pay-for-performance policy in 2001 were more likely to receive RT (odds ratio = 1.23; 95% confidence interval = 1.05-1.45). Subgroup analyses indicated that the high-volume effect was limited to hospitals accredited as non-medical centers, and that the effect of the pay-for-performance policy was most pronounced among low-volume hospitals. Conclusions: Using population-based data from Taiwan, our study concluded that hospital surgical volume and pay-for-performance policy are positively associated with RT use after BCS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relationship Between Pelvic Organ-at-Risk Dose and Clinical Target Volume in Postprostatectomy Patients Receiving Intensity-Modulated Radiotherapy

Purpose: To investigate dose-volume consequences of inclusion of the seminal vesicle (SV) bed in the clinical target volume (CTV) for the rectum and bladder using biological response indices in postprostatectomy patients receiving intensity-modulated radiotherapy (IMRT). Methods and Materials: We studied 10 consecutive patients who underwent prostatectomy for prostate cancer and subsequently received adjuvant or salvage RT to the prostate fossa. The CTV to planning target volume (PTV) expansion was 7 mm, except posterior expansion, which was 5 mm. Two IMRT plans were generated for each patient, including either the prostate fossa alone or the prostate fossa with the SV bed, but identical in all other aspects. Prescription dose was 68.4 Gy in 1.8-Gy fractions prescribed to {>=}95% PTV. Results: With inclusion of the SV bed in the treatment volume, PTV increased and correlated with PTV-bladder and PTV-rectum volume overlap (Spearman {rho} 0.91 and 0.86, respectively; p < 0.05). As a result, the dose delivered to the bladder and rectum was higher (p < 0.05): mean bladder dose increased from 11.3 {+-} 3.5 Gy to 21.2 {+-} 6.6 Gy, whereas mean rectal dose increased from 25.8 {+-} 5.5 Gy to 32.3 {+-} 5.5 Gy. Bladder and rectal equivalent uniform dose correlated with mean bladder and rectal dose. Inclusion of the SV bed in the treatment volume increased rectal normal tissue complication probability from 2.4% to 4.8% (p < 0.01). Conclusions: Inclusion of the SV bed in the CTV in postprostatectomy patients receiving IMRT increases bladder and rectal dose, as well as rectal normal tissue complication probability. The magnitude of PTV-bladder and PTV-rectal volume overlap and subsequent bladder and rectum dose increase will be higher if larger PTV expansion margins are used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗