Aerosol and Gas Transport in Ventilation Ducts in Nonreactor Nuclear Facilities

This document summarizes outcomes and finding in FY 2022 from a project sponsored by the Nuclear Safety Research and Development Program, which is managed by the Office of Nuclear Safety, within the Office of Environment, Health, Safety and Security. Literature survey and data collection are discussed in Sections 1 and 2, respectively. Numerical modeling of particulate transports in ventilation systems performed for standard geometries and a full-scale ventilation system is described in Section 3, and Section 4 summarizes the development of proof-of-concept sensors featuring ultrasound technology for particle deposition removal. Conclusions and recommendations are outlined in Section 5.

42 ENGINEERING↗

Failure mode analysis of the FFTF heating and ventilation system 25

This document was prepared as a supplemental study to Chapter 9.4 of the FFTF Final Safety Analysis Report and is included as a Category A reference in FFTF System Design Description 25, Heating and Ventilation System. It contains the single failure mode analysis on all the heating and ventilation systems that are essential to the safety of the plant, and confirms the adequacy of the system design to accommodate single failures without jeopardizing overall plant safety.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Prognostic analysis of high-flow nasal cannula therapy and non-invasive ventilation in mild to moderate hypoxemia patients and construction of a machine learning model for 48-h intubation prediction—a retrospective analysis of the MIMIC database

Background This study aims to investigate the clinical outcome between high-flow nasal cannula (HFNC) and non-invasive ventilation (NIV) therapy in mild to moderate hypoxemic patients on the first ICU day and to develop a predictive model of 48-h intubation. Methods The study included adult patients from the MIMIC III and IV databases who first initiated HFNC or NIV therapy due to mild to moderate hypoxemia (100 < PaO2/FiO2 ≤ 300). The 48-h and 30-day intubation rates were compared using cross-sectional and survival analysis. Nine machine learning and six ensemble algorithms were deployed to construct the 48-h intubation predictive models, of which the optimal model was determined by its prediction accuracy. The top 10 risk and protective factors were identified using the Shapley interpretation algorithm. Result A total of 123,042 patients were screened, of which, 673 were from the MIMIC IV database for ventilation therapy comparison (HFNC n = 363, NIV n = 310) and 48-h intubation predictive model construction (training dataset n = 471, internal validation set n = 202) and 408 were from the MIMIC III database for external validation. The NIV group had a lower intubation rate (23.1% vs. 16.1%, p = 0.001), ICU 28-day mortality (18.5% vs. 11.6%, p = 0.014), and in-hospital mortality (19.6% vs. 11.9%, p = 0.007) compared to the HFNC group. Survival analysis showed that the total and 48-h intubation rates were not significantly different. The ensemble AdaBoost decision tree model (internal and external validation set AUROC 0.878, 0.726) had the best predictive accuracy performance. The model Shapley algorithm showed Sequential Organ Failure Assessment (SOFA), acute physiology scores (APSIII), the minimum and maximum lactate value as risk factors for early failure and age, the maximum PaCO 2 and PH value, Glasgow Coma Scale (GCS), the minimum PaO 2 /FiO 2 ratio, and PaO 2 value as protective factors. Conclusion NIV was associated with lower intubation rate and ICU 28-day and in-hospital mortality. Further survival analysis reinforced that the effect of NIV on the intubation rate might partly be attributed to the other impact factors. The ensemble AdaBoost decision tree model may assist clinicians in making clinical decisions, and early organ function support to improve patients’ SOFA, APSIII, GCS, PaCO 2 , PaO 2 , PH, PaO 2 /FiO 2 ratio, and lactate values can reduce the early failure rate and improve patient prognosis.

Fu, Wei↗

Exergy Analysis of a Convective Heat Pump Dryer Integrated with a Membrane Energy Recovery Ventilator

To increase energy efficiency, heat pump dryers and membrane dryers have been proposed to replace conventional fossil fuel dryers. Both conventional and heat pump dryers require substantial energy for condensing and reheating, while “active” membrane systems require vacuum pumps that are insufficiently developed. Lower temperature dehumidification systems make efficient use of membrane energy recovery ventilators (MERVs) that do not need vacuum pumps, but their high heat losses and lack of vapor selectivity have prevented their use in industrial drying. In this work, we propose an insulating membrane energy recovery ventilator for moisture removal from drying exhaust air, thereby reducing sensible heat loss from the dehumidification process and reheating energy. The second law analysis of the proposed system is carried out and compared with a baseline convective heat pump dryer. Irreversibilities in each component under different ambient temperatures (5–35 °C) and relative humidity (5–95%) are identified. At an ambient temperature of 35 °C, the proposed system substantially reduces sensible heat loss (47–60%) in the dehumidification process, resulting in a large reduction in condenser load (45–50%) compared to the baseline system. The evaporator in the proposed system accounts for up to 59% less irreversibility than the baseline system. A maximum of 24.5% reduction in overall exergy input is also observed. The highest exergy efficiency of 10.2% is obtained at an ambient condition of 35 °C and 5% relative humidity, which is more than twice the efficiency of the baseline system under the same operating condition.

Balaraman, Anand (ORCID:0000000218355788)↗

Reduction of noise generated by air conditioning and ventilation plants and transmitted to inhabited areas

The fans with which the conditioning and ventilation plants of weaving and spinning mills are equipped and the conditioning devices used in certain confection and knit wear departments of the textile industry generate loud noise. Solutions are presented for reducing the noise generated by the fans of ventilation and conditioning plants and transmitted to inhabited regions down to the admissible level, as well as the results obtained by experimental application of some noise reduction solutions in the conditioning plants of a spinning mill.

Harastaseanu, E.↗

Unsteady two dimensional airloads acting on oscillating thin airfoils in subsonic ventilated wind tunnels

The numerical calculation of unsteady two dimensional airloads which act upon thin airfoils in subsonic ventilated wind tunnels was studied. Neglecting certain quadrature errors, Bland's collocation method is rigorously proved to converge to the mathematically exact solution of Bland's integral equation, and a three way equivalence was established between collocation, Galerkin's method and least squares whenever the collocation points are chosen to be the nodes of the quadrature rule used for Galerkin's method. A computer program displayed convergence with respect to the number of pressure basis functions employed, and agreement with known special cases was demonstrated. Results are obtained for the combined effects of wind tunnel wall ventilation and wind tunnel depth to airfoil chord ratio, and for acoustic resonance between the airfoil and wind tunnel walls. A boundary condition is proposed for permeable walls through which mass flow rate is proportional to pressure jump.

Fromme, J.↗

Fuselage ventilation under wind conditions

To determine realistic fuselage ventilation rates for post-crash fires and full-scale fire tests, the effects on wind-about fuselage ventilation rate of various parameters were studied. The parameters investigated were fuselage size and shape, fuselage orientation and proximity to ground, fuselage-opening and location, and wind speed and direction.

Stuart, J. W.↗

Two dimensional aerodynamic interference effects on oscillating airfoils with flaps in ventilated subsonic wind tunnels

The numerical computation of unsteady airloads acting upon thin airfoils with multiple leading and trailing-edge controls in two-dimensional ventilated subsonic wind tunnels is studied. The foundation of the computational method is strengthened with a new and more powerful mathematical existence and convergence theory for solving Cauchy singular integral equations of the first kind, and the method of convergence acceleration by extrapolation to the limit is introduced to analyze airfoils with flaps. New results are presented for steady and unsteady flow, including the effect of acoustic resonance between ventilated wind-tunnel walls and airfoils with oscillating flaps. The computer program TWODI is available for general use and a complete set of instructions is provided.

Fromme, J.↗

Parametric instabilities of rotor-support systems with application to industrial ventilators

Rotor support systems interaction with parametric excitation is considered for both unequal principal shaft stiffness (generators) and offset disc rotors (ventilators). Instability regions and types of instability are computed in the first case, and parametric resonances in the second case. Computed and experimental results are compared for laboratory machine models. A field case study of parametric vibrations in industrial ventilators is reported. Computed parametric resonances are confirmed in field measurements, and some industrial failures are explained. Also the dynamic influence and gyroscopic effect of supporting structures are shown and computed.

Parszewski, Z.↗

Assessment of the impact of dipped guideways on urban rail transit systems: Ventilation and safety requirements

The ventilation and fire safety requirements for subway tunnels with dipped profiles between stations as compared to subway tunnels with level profiles were evaluated. This evaluation is based upon computer simulations of a train fire emergency condition. Each of the tunnel configurations evaluated was developed from characteristics that are representative of modern transit systems. The results of the study indicate that: (1) The level tunnel system required about 10% more station cooling than dipped tunnel systems in order to meet design requirements; and (2) The emergency ventilation requirements are greater with dipped tunnel systems than with level tunnel systems.

Source record↗

Ventilation flow: Submerged

The ventilation system on a submarine is discussed. When the submarine is submerged. The ventilation system provides a conditioned atmosphere in the ship with complete isolation from the outside. A conditioned atmosphere includes not only filtration and temperature and humidity control, but also air purification (removal of potentially harmful quantities of impurities and comtaminants) and revitalization (addition of vital life support oxygen). Carbon dioxide removal, the oxygen system, air conditioning, carbon monoxide removal, hydrogen removal, and atmosphere monitoring systems are among the topics discussed.

Hutchinson, D.↗

Pool fire-ventilation crossflow experiments in a simulated aircraft cabin interior

An experimental facility has been built to study pool fire dynamics and flame spread behavior in a 1/3-scale simulated aircraft interior; attention is presently given to pool fire ventilation crossflow using a 'channel' pool fire subjected to crossflow velocities that replicate postcrash conditions in a wide body aircraft. Crossflow velocity is noted to have a strong effect on visible flame geometry, tilting the flame over sharply. A reverse flow ceiling jet of hot gases was also present in all tests, however, and extended far upstream of the fire, so that despite the appearance of the visible flame, the vertical momentum of the plume was strong enough to establish the reverse flow layer and spread smoke and toxic gases upstream against a significant ventilating flow.

Bankston, C. P.↗

Pool fires in a simulated aircraft cabin interior with ventilation

Results of experiments conducted at the JPL to evaluate aircraft postcrash fire hazards are presented. The experiments were carried out in a one-third scale simulated aircraft cabin geometry to study pool fire and ventilation flow interactions. It is shown that wind-induced ventilation may significantly affect fire plume orientation, smoke transport, and heat fluxes and thus will affect subsequent fire spread and the immediate survivability of the passengers.

Bankston, C. P.↗

Intermodule ventilation studies for the Space Station

This paper examines the ability of the Space Station intermodule ventilation system to maintain centralized control of CO2 removal and O2 supply. The resulting concentration gradients that will arise are calculated by assuming steady state, ideal gas, isothermal conditions, and perfect mixing of air within and between the pressurized elements. In order to estimate the degree of mixing actually obtained for a given ventilation scheme, a program has been developed based on a potential flow solution technique. Preliminary results from this study indicate that substantial short circuiting and recirculation air flow patterns could arise if a simple duct and diffuser air exchange method at the docking port interface were employed.

Davis, Roy G.↗

An air bearing fan for EVA suit ventilation

The portable life-support system (PLSS) ventilation requirements are outlined, along with the application of a high-speed axial fan technology for extravehicular-activity (EVA) space-suit ventilation. Focus is placed on a mechanical design employing high-speed gas bearings, permanent magnet rotor, and current-fed chopper/inverter electronics. The operational characteristics of the fan unit and its applicability for use in a pure-oxygen environment are discussed. It delivers a nominal 0.17 cu m/min at 1.24 kPa pressure rise using 13.8 w of input power. It is shown that the overall selection of materials for all major component meets the NASA requirements.

Murry, Roger P.↗

Ventilation loss and pressurization in the NASA launch/entry suit: Potential for heat stress

The potential of the NASA Launch/Entry Suit (LES) for producing heat stress in a simulated Space Shuttle cabin environment was studied. The testing was designed to identify potential heat stress hazards if the LES were pressurized or if ventilation were lost. Conditions were designed to simulate an extreme pre-launch situation with chamber temperatures maintained at dry bulb temperature = 27.2 +/- 0.1 C, globe temperature = 27.3 +/- 0.1 C, and wet bulb temperature = 21.1 +/- 0.3 C. Two females and two males, 23 to 34 years of age, were employed in this study, with two subjects having exposures in all 3 conditions. Test durations in the ventilated (V) and unventilated (UV) conditions were designed for 480 minutes, which all subjects achieved. Pressurized runs (Pr) were designed for 45 minutes, which all subjects also achieved. While some significant differences related to experimental conditions were noted in rectal and mean skin temperatures, evaporation rates, sweat rates, and heart rate, these differences were not thought to be physiologically significant. The results indicate that the LES garment, in either the Pr or UV state, poses no danger of inducing unacceptable heat stress under the conditions expected within the Space Shuttle cabin during launch or reentry.

Kaufman, Jonathan W.↗

Ventilation of North Pacific Intermediate Waters - The role of the Alaskan Gyre

Hydrographic data, tritium data, and potential vorticity calculations suggest that although North Pacific Intermediate Water is formed in the northwest, the Alaskan Gyre might be an additional ventilation site. The proposed ventilation is quantified by a vertical column tritium inventory, which indicates an excess of 0.08 kg of tritium in the Alaskan Gyre. An evaluation of the energy stored in the water column and of wind and buoyancy forcing shows that during winter conditions enough energy can be pumped into the system to force 26.80 sigma(theta) to outcrop in the Alaskan Gyre. Model results suggest that relatively limited outcrops in time and space (tens of days and several hundred kilometers in diameter) can account for the excess tritium.

Van Scoy, Kim A.↗

Remote manual operator for space station intermodule ventilation valve

The Remote Manual Operator (RMO) is a mechanism used for manual operation of the Space Station Intermodule Ventilation (IMV) valve and for visual indication of valve position. The IMV is a butterfly-type valve, located in the ventilation or air circulation ducts of the Space Station, and is used to interconnect or isolate the various compartments. The IMV valve is normally operated by an electric motor-driven actuator under computer or astronaut control, but it can also be operated manually with the RMO. The IMV valve RMO consists of a handle with a deployment linkage, a gear-driven flexible shaft, and a linkage to disengage the electric motor actuator during manual operation. It also provides visual indication of valve position. The IMV valve RMO is currently being prepared for qualification testing.

Guyaux, James R.↗