Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VEIN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A New Occlusion Device: Application of the ArtVentive Endoluminal Occlusion System (EOS)—First in Human Clinical Trial

Purpose: The purpose of this study was to determine the safety and efficacy of a new endoluminal occlusion device, ArtVentive endoluminal occlusion system (EOS), to occlude the spermatic vein in symptomatic males with varicoceles. Methods: The ArtVentive EOS device has been developed for percutaneous, peripheral occlusion of the peripheral arterial and venous vasculature. The system is comprised of an implantable occlusion device and a delivery catheter. At present, there are two device sizes: (a) size 1 for target vessels ranging between 3.5 and 5.5 mm in diameter, and (b) size 2 for target vessels 5.5–8.5 mm in diameter. The treatment group included six adult males, ages 22–34 years. Nine target vessels were occluded. A total of 20 devices were implanted in six subjects. Results: The acute occlusion rate at the end of the procedure was 100 % occurring in nine of nine vessels. The spermatic veins of all patients remained occluded on venography at 30 days follow-up. Pain scores related to varicoceles decreased in five of six patients. Conclusions: Although we recognize this study is limited, initial experience indicates that the ArtVentive EOS is a safe and effective new device for occlusion of vessels (varicoceles). The device has potential applications in other clinical conditions requiring occlusion of veins or arteries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Anatomical, Procedural, and Operator Skill Factors on the Success and Duration of Fluoroscopy-Guided Transjugular Intrahepatic Portosystemic Shunt

PurposeTo assess the impact of anatomical, procedural, and operator skill factors on the success and duration of fluoroscopy-guided transjugular intrahepatic portoystemic shunt following standard operating procedure (SOP).Material and MethodsDuring a 32-month period, 102 patients underwent transjugular intrahepatic portosystemic shunt creation (TIPS) by two interventional radiologists (IR) following our institutional SOP based on fluoroscopy guidance. Both demographic and procedural data were assessed. The duration of the intervention (D{sub Int}) and of the portal vein puncture (D{sub Punct}) was analyzed depending on the skill level of the IR as well as the anatomic or procedural factors.ResultsIn 99 of the 102 patients, successful TIPS without peri-procedural complications was performed. The mean D{sub Int} (IR1: 77 min; IR2: 51 min, P < 0.005) and the mean D{sub Punct} (IR1: 19 min; IR2: 13 min, P < 0.005) were significantly higher in TIPS performed by IR1 (with 2 years of clinical experience performing TIPS, n = 38) than by IR2 (>10 years of clinical experience performing TIPS, n = 61), (P < 0.005 both, Mann–Whitney U test). D{sub Int} showed a higher correlation with D{sub Punct} for IR2 (R{sup 2} = 0.63) than for IR1 (R{sup 2} = 0.13). There was no significant difference in the D{sub Punct} for both IRs with regard to the success of the wedged portography (P = 0.90), diameter of the portal vein (P = 0.60), central right portal vein length (P = 0.49), or liver function (MELD-Score before the TIPS procedure; P = 0.14).ConclusionTIPS following SOP is safe, fast, and reliable. The only significant factor for shorter D{sub Punct} and D{sub Int} was the clinical experience of the IR. Anatomic variability, successful portography, or liver function did not alter the duration or technical success of TIPS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Exposure in Transjugular Intrahepatic Portosystemic Shunt Creation

PurposeTransjugular intrahepatic portosystemic shunt (TIPS) creation is considered as being one of the most complex procedures in abdominal interventional radiology. Our aim was twofold: quantification of TIPS-related patient radiation exposure in our center and identification of factors leading to reduced radiation exposure.Materials and methodsThree hundred and forty seven consecutive patients underwent TIPS in our center between 2007 and 2014. Three main procedure categories were identified: Group I (n = 88)—fluoroscopic-guided portal vein targeting, procedure done in an image intensifier-based angiographic system (IIDS); Group II (n = 48)—ultrasound-guided portal vein puncture, procedure done in an IIDS; and Group III (n = 211)—ultrasound-guided portal vein puncture, procedure done in a flat panel detector-based system (FPDS). Radiation exposure (dose-area product [DAP], in Gy cm{sup 2} and fluoroscopy time [FT] in minutes) was retrospectively analyzed.ResultsDAP was significantly higher in Group I (mean ± SD 360 ± 298; median 287; 75th percentile 389 Gy cm{sup 2}) as compared to Group II (217 ± 130; 178; 276 Gy cm{sup 2}; p = 0.002) and Group III (129 ± 117; 70; 150 Gy cm{sup 2}p < 0.001). The difference in DAP between Groups II and III was also significant (p < 0.001). Group I had significantly longer FT (25.78 ± 13.52 min) as compared to Group II (20.45 ± 10.87 min; p = 0.02) and Group III (19.76 ± 13.34; p < 0.001). FT was not significantly different between Groups II and III (p = 0.73).ConclusionsReal-time ultrasound-guided targeting of the portal venous system during TIPS creation results in a significantly lower radiation exposure and reduced FT. Further reduction in radiation exposure can be achieved through the use of modern angiographic units with FPDS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Results of Stent Placement in Patients with Outflow Block After Living-Donor-Liver Transplantation

PurposeTo evaluate long-term results of stent placement retrospectively in patients with outflow block after living-donor-liver transplantation (LDLT).Materials and MethodsFor this institutional review board approved retrospective study conducted during 2002–2012, stents were placed in outflow veins in 15 patients (11.3 %, 15/133) (12 men; 3 female) in whom outflow block developed after LDLT. Their mean age was 52.3 years ± 15.3 (SD) (range, 4–69 years). Venous stenosis with a pressure gradient ≥5 mmHg (outflow block) was observed in the inferior vena cava in seven patients, hepatic vein in seven patients, and both in one patient. Technical success, change in a pressure gradient and clinical manifestations, and complications were evaluated. Overall survival of 15 patients undergoing outflow block stenting was compared with that of 116 patients without outflow block after LDLT.ResultsStents were placed across the outflow block veins without complications, lowering the pressure gradient ≤ 3 mmHg in all patients (100 %, 15/15). Clinical manifestations improved in 11 patients (73.3 %, 11/15), and all were discharged from the hospital. However, they did not improve in the other 4 patients (26.7 %, 4/15) who died in the hospital 1.0–3.7 months after stenting (mean, 2.0 ± 1.2 months). No significant difference in 5-year survival rates was found between patients with and without outflow block after LDLT (61.1 vs. 72.2 %, p = .405).ConclusionStenting is a feasible, safe, and useful therapeutic option to resolve outflow block following LDLT, providing equal survival to that of patients without outflow block.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional Image Fusion Guidance for Transjugular Intrahepatic Portosystemic Shunt Placement

IntroductionTo assess the safety, feasibility and effectiveness of image fusion guidance with pre-procedural portal phase computed tomography with intraprocedural fluoroscopy for transjugular intrahepatic portosystemic shunt (TIPS) placement.Materials and methodsAll consecutive cirrhotic patients presenting at our interventional unit for TIPS creation from January 2015 to January 2016 were prospectively enrolled. Procedures were performed under general anesthesia in an interventional suite equipped with flat panel detector, cone-beam computed tomography (CBCT) and image fusion technique. All TIPSs were placed under image fusion guidance. After hepatic vein catheterization, an unenhanced CBCT acquisition was performed and co-registered with the pre-procedural portal phase CT images. A virtual path between hepatic vein and portal branch was made using the virtual needle path trajectory software. Subsequently, the 3D virtual path was overlaid on 2D fluoroscopy for guidance during portal branch cannulation. Safety, feasibility, effectiveness and per-procedural data were evaluated.ResultsSixteen patients (12 males; median age 56 years) were included. Procedures were technically feasible in 15 of the 16 patients (94%). One procedure was aborted due to hepatic vein catheterization failure related to severe liver distortion. No periprocedural complications occurred within 48 h of the procedure. The median dose-area product was 91 Gy cm{sup 2}, fluoroscopy time 15 min, procedure time 40 min and contrast media consumption 65 mL. Clinical benefit of the TIPS placement was observed in nine patients (56%).ConclusionThis study suggests that 3D image fusion guidance for TIPS is feasible, safe and effective. By identifying virtual needle path, CBCT enables real-time multiplanar guidance and may facilitate TIPS placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Fusion Guidance with Pre-procedural CT with Real-Time Fluoroscopy for Adrenal Venous Sampling

PurposeTo assess the effectiveness of image fusion guidance (IF) with pre-procedural computed tomography (CT) with intraprocedural fluoroscopy for adrenal venous sampling (AVS).Materials and MethodsAVS before and after ACTH stimulation including bilateral segmental sampling of effluent tributaries was performed in 62 patients with IF. A 3D volume rendering image, including adrenal glands and veins extracted from previously obtained contrast-enhanced CT images, was manually registered to the real-time X-ray fluoroscopy. The technical success rates, procedure time, radiation exposure, and volume of contrast medium used were compared with 49 patients who underwent AVS without IF.ResultsNo significant differences in the technical success rates with and without IF were observed (98.4 vs. 91.8% for the right adrenal veins, p = 0.168, and 98.4 vs. 100% for the left adrenal veins, p = 1.000). The procedure time with IF was significantly shorter than that without IF (95.6 ± 18.8 vs. 108.4 ± 20.0 min, p = 0.001). The total dose-area product with IF was significantly lower than that without IF (43.1 ± 30.7 vs. 72.2 ± 45.3 Gy cm{sup 2}, p < 0.001). The contrast medium volume used with IF was significantly lower than that without IF (54.6 ± 21.9 vs. 65.7 ± 27.6 mL, p = 0.020).ConclusionsAlthough the contribution to improving the technical success rates was small in our study, IF can effectively reduce procedure time, radiation exposure, and volume of contrast medium during AVS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Approach, Technical Success, Complications, and Stent Patency of Sharp Recanalization for the Treatment of Chronic Venous Occlusive Disease: Experience in 123 Patients

Purpose: To report the technical success and complications following sharp recanalization of chronic venous occlusions. Materials and Methods: A total of 123 patients, including 75 (61.0%) men and 48 (39.0%) women, with mean age of 50.5 ± 17.5 years (range 19–90 years), underwent sharp recanalization of chronic venous occlusions. The etiologies of occlusion were chronic deep venous thrombosis (n = 43; 35.0%), prior central venous access (n = 39; 31.7%), indwelling cardiac leads (n = 21; 17.1%), and occluded venous stents (n = 20; 16.3%). The sites of venous occlusion included 59/123 (48.0%) thoracic central veins, 37 (30.1%) non-thoracic central veins, and 27 (22.0%) peripheral veins. Median length of occlusion was 3.2 ± 1.4 cm (range 1.3–10.9 cm). Results: Sharp recanalization was most commonly attempted with transseptal needles in 108/123 (87.8%), with a mean number of 1.2 ± 0.4 crossing devices per patient (range 1–4 devices). Targeting devices included a loop snare (n = 92; 74.8%), partially deployed Wallstent (n = 21; 17.1%), partially deployed Amplatzer vascular plug (n = 8; 6.5%), and an angioplasty balloon (n = 3; 2.4%). Technical success was achieved in 111 (90.2%) patients. There were 3 (2.4%) severe, 1 (0.8%) moderate, and 7 (5.7%) minor adverse events. Severe adverse events included 1 case each of pericardial tamponade, hemothorax, and inferior vena cava filter occlusion. 88 (71.5%) patients had venous stents placed; at the last follow-up examination, 68/86 (79.0%) stents were patent. Conclusion: Sharp recanalization has a high technical success and low rate of adverse events in the recanalization of chronic venous occlusions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors of Liver Toxicity Following Stereotactic Body Radiation Therapy for Hepatocellular Carcinoma

Purpose: To identify risk factors associated with a decline in liver function after stereotactic body radiation therapy (SBRT) for hepatocellular carcinoma. Methods and Materials: Data were analyzed from patients with hepatocellular carcinoma treated on clinical trials of 6-fraction SBRT. Liver toxicity was defined as an increase in Child-Pugh (CP) score ≥2 three months after SBRT. Clinical factors, SBRT details, and liver dose-volume histogram (DVH) parameters were tested for association with toxicity using logistic regression. CP class B patients were analyzed separately. Results: Among CP class A patients, 101 were evaluable, with a baseline score of A5 (72%) or A6 (28%). Fifty-three percent had portal vein thrombus. The median liver volume was 1286 cc (range, 766-3967 cc), and the median prescribed dose was 36 Gy (range, 27-54 Gy). Toxicity was seen in 26 patients (26%). Thrombus, baseline CP of A6, and lower platelet count were associated with toxicity on univariate analysis, as were several liver DVH-based parameters. Absolute and spared liver volumes were not significant. On multivariate analysis for CP class A patients, significant associations were found for baseline CP score of A6 (odds ratio [OR], 4.85), lower platelet count (OR, 0.90; median, 108 × 10{sup 9}/L vs 150 × 10{sup 9}/L), higher mean liver dose (OR, 1.33; median, 16.9 Gy vs 14.7 Gy), and higher dose to 800 cc of liver (OR, 1.11; median, 14.3 Gy vs 6.0 Gy). With 13 CP-B7 patients included or when dose to 800 cc of liver was replaced with other DVH parameters (eg, dose to 700 or 900 cc of liver) in the multivariate analysis, effective volume and portal vein thrombus were associated with an increased risk. Conclusions: Baseline CP scores and higher liver doses (eg, mean dose, effective volume, doses to 700-900 cc) were strongly associated with liver function decline 3 months after SBRT. A lower baseline platelet count and portal vein thrombus were also associated with an increased risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-129: Atlas Development for Cardiac Automatic Contouring Using Multi-Atlas Segmentation

Purpose: To develop a set of atlases for automatic contouring of cardiac structures to determine heart radiation dose and the associated toxicity. Methods: Six thoracic cancer patients with both contrast and non-contrast CT images were acquired for this study. Eight radiation oncologists manually and independently delineated cardiac contours on the non-contrast CT by referring to the fused contrast CT and following the RTOG 1106 atlas contouring guideline. Fifteen regions of interest (ROIs) were delineated, including heart, four chambers, four coronary arteries, pulmonary artery and vein, inferior and superior vena cava, and ascending and descending aorta. Individual expert contours were fused using the simultaneous truth and performance level estimation (STAPLE) algorithm for each ROI and each patient. The fused contours became atlases for an in-house multi-atlas segmentation. Using leave-one-out test, we generated auto-segmented contours for each ROI and each patient. The auto-segmented contours were compared with the fused contours using the Dice similarity coefficient (DSC) and the mean surface distance (MSD). Results: Inter-observer variability was not obvious for heart, chambers, and aorta but was large for other structures that were not clearly distinguishable on CT image. The average DSC between individual expert contours and the fused contours were less than 50% for coronary arteries and pulmonary vein, and the average MSD were greater than 4.0 mm. The largest MSD of expert contours deviating from the fused contours was 2.5 cm. The mean DSC and MSD of auto-segmented contours were within one standard deviation of expert contouring variability except the right coronary artery. The coronary arteries, vena cava, and pulmonary vein had DSC<70% and MSD>3.0 mm. Conclusion: A set of cardiac atlases was created for cardiac automatic contouring, the accuracy of which was comparable to the variability in expert contouring. However, substantial modification may need for auto-segmented contours of indistinguishable small structures.

60 APPLIED LIFE SCIENCES↗

Liver Resection with In Situ Hypothermic Perfusion: An Old but Effective Method

Background: More than 40 years ago, patients with tumors infiltrating the confluence of the hepatic veins were deemed unresectable; however, in situ hypothermic perfusion, first described by Fortner et al. (Ann Surg 180(4):644–652, 1974), allowed resection of these tumors. In order to prevent liver ischemia after total vascular exclusion, the liver was flushed with a cooled organ preservation solution. The surgeon was able to resect the tumor and reconstruct the hepatic veins with occlusion of the hepatic inflow and outflow. Methods: A 55-year-old female suffering from a leiomyosarcoma of the inferior vena cava (IVC) presented to our clinic. Three years ago, the IVC was replaced with a synthetic graft. During the patient’s follow-up, a computed tomography (CT) scan revealed three hepatic metastases of the sarcoma. A central metastasis in Segment 8 infiltrated the right hepatic vein (RHV), and two additional metastases were located in the left lateral segments. We used Fortner’s technique to resect these tumors. Results: The postoperative course of the patient was prolonged due to a hematoma that partially compressed the new RHV graft. A re-laparotomy was performed and drains were placed. On the 15th postoperative day, the patient was discharged in good health. Conclusions: Although nowadays patients with these unfortunate tumor locations can, to some extent, be managed non-operatively, surgery remains an option with a chance of cure. Azoulay et al. (Ann Surg 262(1):93–104, 2015) were able to show satisfactory 5-year-survival in 77 patients (30.4%), however 90-day mortality was high (19.5%). Therefore, patients need to be selected carefully. In the era of minimally invasive liver surgery, these old techniques should not vanish from the armamentarium of liver surgeons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robotic Extended Right Hemicolectomy with Complete Mesocolic Excision and D3 Lymph Node Dissection

Background: Recent studies have shown the benefits of complete mesocolic excision and extended lymphadenectomy (D3 lymph node dissection) in patients with colon cancer.1{sup –}3 Methods: We present the case of a 62-year-old male with hepatic flexure adenocarcinoma. No metastatic disease was identified by computed tomography. A robot-assisted extended right hemicolectomy with complete mesocolic excision, D3 lymph node dissection, and resection of the mesentery with intact visceral peritoneum was performed. Results: The trocars are placed in the right lower (8 mm), lower midline (8 mm), and left upper (12 mm) quadrants. The camera port is placed superior to the umbilicus, and the assistant port is placed in the left lower quadrant. The robotic right lower port is used to place the cecum on tension in order to outline the ileocolic pedicle. The assistant retracts the transverse colon cephalad to outline the superior mesenteric artery and vein. Using two robotic arms, the surgeon begins dissection over the superior mesenteric vein inferior to the ileocolic pedicle. Cephalad dissection along the superior mesenteric vein proceeds with reflection of the mesentery and D3 lymph nodes laterally to allow en bloc resection. The ileocolic and middle colic vessels are identified, ligated and divided at their origins. The plane is then developed between the right colon mesentery and the retroperitoneum, including Gerota’s fascia, duodenum, and head of the pancreas, in a medial-to-lateral fashion, with care taken to ensure an intact visceral peritoneum is maintained. The proximal transverse colon, hepatic flexure, and ascending colon are mobilized by taking down lateral attachments. The intervening mesentery is transected, and perfusion is assessed with indocyanine green fluorescence imaging. An intracorporeal, isoperistaltic, side-to-side anastomosis is performed using the 45-mm robotic stapler. The common enterotomy is sewn closed in two layers. Pathology showed T3N0 adenocarcinoma with all negative margins. Conclusion: Extended right hemicolectomy with complete mesocolic excision and D3 lymph node dissection is facilitated by a robotic approach, which improves visualization and instrument dexterity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An in-situ 3D micro-XRD investigation of water uptake by alkali-silica-reaction (ASR) product

The ASR products in concrete have various chemical compositions. It is yet unclear whether and how these products develop micro-expansion upon moisture ingress. This paper presents a 3D in-situ observation of the crystallography and volume change of an ASR-product-filled vein under varying relative-humidity (R.H.). The vein was observed to contain two layered nano-crystalline phases with distinct basal spacings, and was distributed heterogeneously in space. When R.H. changed from 10% to >38%, the basal spacing increased from 7.43 Å to 8.89 Å for one phase, whereas it remained constant (~10.9 Å) for the other. This is the first time that an ASR product is observed in-situ to exhibit crystal structural expansion during wetting process. However, the product-filled vein exhibited no noticeable swelling when R.H. varied from 10% to 97%. Our findings provide the first direct evidence that the moisturization-induced crystal structural change of ASR product may not be a plausible explanation to the macroscale concrete expansion.

36 MATERIALS SCIENCE↗

ChemCam investigation of the John Klein and Cumberland drill holes and tailings, Gale crater, Mars

The ChemCam instrument on the Mars Science Laboratory rover analyzed the rock surface, drill hole walls, tailings, and unprocessed and sieved dump piles to investigate chemical variations with depth in the first two martian drill holes and possible fractionation or segregation effects of the drilling and sample processing. Furthermore, the drill sites are both in Sheepbed Mudstone, the lowest exposed member of the Yellowknife Bay formation. Yellowknife Bay is composed of detrital basaltic materials in addition to clay minerals and an amorphous component. The drill tailings are a mixture of basaltic sediments and diagenetic material like calcium sulfate veins, while the shots on the drill site surface and walls of the drill holes are closer to those pure end members. The sediment dumped from the sample acquisition, processing, and handling subsystem is of similar composition to the tailings; however, due to the specifics of the drilling process the tailings and dump piles come from different depths within the hole. This then allows the ChemCam instrument to analyze samples representing the bulk composition from different depths. On the pre-drill surfaces, the Cumberland site has a greater amount of CaO and evidence for calcium sulfate veins, than the John Klein site. But, John Klein has a greater amount of calcium sulfate veins below the surface, as seen in mapping, drill hole wall analysis, and observations in the drill tailings and dump pile. In addition, the Cumberland site does not have any evidence of variations in bulk composition with depth down the drill hole, while the John Klein site has evidence for a greater amount of CaO (calcium sulfates) in the top portion of the hole compared to the middle section of the hole, where the drill sample was collected.

79 ASTRONOMY AND ASTROPHYSICS↗

RSPECT: A PROSPECT-based model incorporating the real structure of rice leaves

Radiative transfer models (RTMs) describe how light is absorbed, scattered, and transmitted within leaves by simulating mechanistic light propagation processes. The PROSPECT model is based on measurable parameters (the leaf biochemical content) and a non-measurable parameter (the leaf anatomical structure represented by the leaf structure parameter (N)). The effect of N on the optical properties of leaves has been investigated through a number of local and global sensitivity analyses. Other studies have directly evaluated the effect of the leaf anatomical structure on spectral reflectance, particularly in the near infrared region. However, the relationship between N and the anatomical structure is unclear. Here, in this study, we leveraged eLeaf, a ray tracing-based 3D rice leaf simulator, to establish relationships between leaf anatomical features and spectral properties, enabling us to replace N in the PROSPECT-4 model with measurable leaf anatomical parameters and develop the RSPECT model. The leaf thickness at minor vein, leaf thickness at bulliform cells, mesophyll thickness at minor vein, and distance between two minor veins could be used to predict N effectively. The RSPECT model achieved spectral simulation accuracy comparable to PROSPECT-4 and was more suitable for parameter inversion of the physical and chemical properties of rice leaves, with relative root mean square errors of 7.4% for chlorophyll content, 5.6% for equivalent water thickness, and 7.5% for dry matter content. In conclusion, RSPECT improves radiative transfer modeling by integrating measurable anatomical features and provides a framework for extending this approach to other vegetation types.

hyperspectral↗

Golden ratio in venation patterns of dragonfly wings

Abstract The vein pattern in insect wings allows this lightweight structure to carry multiple biological functions. Here, an investigation of the angular distribution of the vein struts in dragonfly wings revealed that the golden angle or golden ratio dominates the venation patterns. We find that the golden angle dominates the intervein angles in regions where thin veins and membranes demand strength reinforcement. A golden ratio partition method has thus been developed that explains a set of preferred intervein angles in distorted polygon-shaped venation cells throughout the venation pattern in dragonfly wings. These observations provide new evidence that the wing structure is spatially optimized, by the golden rule in nature, for supporting biomechanical functions of dragonfly wings.

36 MATERIALS SCIENCE↗

Heavy mineral distribution in stream sediment of Tapah area, Perak, Malaysia

This paper aims to provide the overview of occurrence, distribution and origin of the heavy minerals in the study area. A total of 45 selected stream sediment heavy mineral concentrate samples were panned using standard dulangs, dried and separated from other light minerals using bromoform. The heavy minerals were separated into different fractions at different amperes using Frantz Isodynamic magnetic separator. Mineral identification was done using binocular microscope augmented by X-ray diffraction analyses. Mineral abundance data were analysed graphically using triangular diagrams to show their origin. Dominant minerals present in the heavy mineral samples collected are ilmenite, cassiterite, tourmaline, zircon, topaz, and magnetite. The less common minerals, present in trace amounts are hematite, xenotime, allanite, monazite, rutile, anatase, leucoxene, chromite, garnet and olivine. Examination of the heavy mineral assemblage shows that they originated from granite batholiths of the Main Range, Changkat Rembian as well as from the metasedimentary rock in the area. The gold flakes present are found together with cassiterite and topaz indicating that gold originates from the mineralized veins contact-metamorphosed metasedimentary rocks. Almost all samples collected contain cassiterite grains in various amounts. From the mineral assemblage, the source of cassiterite originates from the mineralized quartz veins that cut granitic rocks of Main Range, Changkat Rembian as well as the metasedimentary rock in the area. Greisenized veins containing quartz, mica and tourmaline with the presence of wolframite and arsenopyrite also contribute to the presence of cassiterite in this study area.

36 MATERIALS SCIENCE↗

Microstructural characterization of phase-separated co-deposited Cu–Ta immiscible alloy thin films

Elevated temperature co-sputtering of immiscible elements ends in a variety of self-organized morphologies due to phase separation. Cu–Ta is used as a model system to understand the evolution of phase-separated microstructural morphologies by co-sputtering thin films with nominal 50–50 at.% composition at four temperatures: 25, 400, 600, and 800 °C. Scanning/transmission electron microscopy of the film cross sections showed the microstructure morphology varied from nanocrystalline Cu–Ta at 25 °C to a wavy ribbon-like structure at 400 °C, to Cu-rich agglomerates surrounded by Ta-rich veins at 600 and 800 °C. In the agglomerate-vein morphology, microstructural features were present on two length scales, from a few nanometers to a few tens of nanometers, thus making the structures hierarchical. On the nanoscale, the Cu-rich agglomerates contained Ta precipitates, whereas the Ta-rich veins had embedded Cu nanocrystals. The various microstructures can be attributed to the highly disparate constituent element interdiffusion at the deposition temperatures with the Cu having orders of magnitude higher mobility than Ta at the deposition temperatures. This research of processing–microstructure relationship will be useful in guiding the design of hierarchical multiphase microstructures in binary or multicomponent thin films with tailored mechanical properties.

36 MATERIALS SCIENCE↗

Chemical fractionations in meteorites. X - Ureilites

An investigation involving the measurement of 17 trace elements in 4 ureilites was conducted with the objective to obtain information for the characterization of the two components of the ureilites. The groundmass of the mineral is an olivine-clinopyroxene rock which is presumably the residue left after partial melting of a more primitive precursor. This ultramafic rock is permeated by a network of veins containing diamond, graphite, nickel-iron, and primordial noble gases. Attention is given to the vein material, the origin of the vein material, the 'constant' siderophile component and ultramafic rock, and questions concerning the origin of ureilites.

Higuchi, H.↗