Thermo-acoustoelastic effect of Rayleigh wave: Theory and experimental verification

Previous studies showed that the thermally-induced ultrasonic bulk wave velocity change could be used to measure acoustoelastic coefficients and third-order elastic constants of elastic materials. This method is naturally immune from the ambient temperature effect and has improved sensitivity and a simpler test setup than the conventional acoustoelastic test. However, Rayleigh wave is preferred for thick components or structures with only one accessible surface. In this work, the thermo-hyperelastic constitutive equation, along with acoustoelastic theory, is used to derive the expression of the thermo-acoustoelastic coefficient (TAEC) of Rayleigh wave. The numerical relationship between the TAEC of Rayleigh wave and Murnaghan constants ( l, m and n ) are given for common metals. Further, the TAEC expressions for Rayleigh wave and shear wave are similar, and both are dominated by the constant m . The TAEC of Rayleigh wave was measured on an aluminum 6061 specimen using the thermal modulation experiment in a temperature range of 22 ~ 35°C. The measured TAEC shows good agreement with the theoretical calculation. Then the third-order elastic constants were calculated based on TAECs of bulk waves and Rayleigh wave.

42 ENGINEERING↗

Ultrasonic evaluation of mechanical properties of thick, multilayered, filament wound composites

A preliminary investigation is conducted to define capabilities and limitations of ultrasonic and acousto-ultrasonic measurements related to mechanical properties of filament wound graphite/epoxy composite structures. The structures studied are segments of filament wound cylinders formed of multiple layers of hoop and helical windings. The segments consist of 24 to 35 layers and range from 3.02 to 3.34 cm in wall thickness. The resultant structures are anisotropic, heterogeneous, porous, and highly attenuating to ultrasonic frequencies greater than 1 MHz. The segments represent structures to be used for space shuttle booster cases. Ultrasonic velocity and acousto-ultrasonic stress wave factor measurement approaches are discussed. Correlations among velocity, density, and porosity, and between the acousto-ultrasonic stress wave factor and interlaminar shear strength are presented.

Kautz, H. E.↗

Ultrasonic evaluation of mechanical properties of thick, multilayered, filament-wound composites

A preliminary investigation is conducted to define capabilities and limitations of ultrasonic and acousto-ultrasonic measurements related to mechanical properties of filament wound graphite/epoxy composite structures. The structures studied are segments of filament wound cylinders formed of multiple layers of hoop and helical windings. The segments consist of 24 to 35 layers and range from 3.02 to 3.34 cm in wall thickness. The resultant structures are anisotropic, heterogeneous, porous, and highly attenuating to ultrasonic frequencies greater than 1 MHz. The segments represent structures to be used for Space Shuttle booster cases.Ultrasonic velocity and acousto-ultrasonic stress wave factor measurement approaches are discussed. Correlations among velocity, density, and porosity, and between the acousto-ultrasonic stress wave factor and interlaminar shear strength are presented.

Kautz, H. E.↗

Apparatus for acoustically coupling an ultrasonic transducer with a body

An apparatus for acoustically coupling an ultrasonic transducer with a body along whose surface waves are to be transmitted includes a wedge having a first surface for acoustically contacting a subject surface area of a body to be measured, on which surface waves are to be transmitted, and a second surface for accoustically contacting an ultrasonic transducer. The wedge includes a cylinder in which the second surface is present and which is movably disposed in a recess in a block in which the first surface is present, for orienting the first surface and the second surface relative to each other so that ultrasonic waves emitted by the ultrasonic transducer generate surface waves which travel on the subject surface area of the body when the ultrasonic transducer is in acoustic contact with the second surface and the first surface is in acoustic contact with the subject surface area of the body. In the preferred embodiment, there is a third surface which is orientable relative to the first surface so that ultrasonic waves emitted by an ultrasonic transducer in contact with the third surface generate surface waves which travel on the subject surface area of the body when the first surface is an acoustic contact with the subject surface area of the body.

Marshall, Scot H.↗

Contoured PPM-EMAT Design for Ultrasonic Communication On Metallic Pipe Channels

Ultrasonic guided waves can be used as the carriers of information in ultrasonic communication for pipe or plate channels. Permanent Periodic Magnet (PPM) Electromagnetic Acoustic Transducer (EMAT) can potentially provide unique capabilities for a communication system as a non-contact transmitter and receiver, which can selectively generate different modes of shear-horizontal (SH) waves. The SH wave shows the potentials in achieving high bitrate without error in ultrasonic communication. However, when a steel pipe is used as the communication channel, especially one with a radius comparable to the size of the transducer, no guided wave signal can be excited or detected by existing PPM-EMAT's with flat coupling surface. In this paper, a 3D printed magnet holder is designed which can shape the magnet array. Also, the transmitter/receiver coils are made of flexible printed circuit which can fit over the curvature of the pipe channels. The contoured PPM-EMAT transmitter and receiver can conform to the surface of the steel pipe channel in order to generate and detect torsional waves. Experimental tests of signal transmission with PPM-EMAT on a 160cm-long stainless steel pipe determine the optimal frequency for communication to be 916KHz. Information transmission experimental results confirm the validity of contoured PPM-EMAT for communication with a bitrate of 5kbps.

Huang, Xin↗

Three-dimensional broadband nonlinear phased array imaging

System include an ultrasonic transducer configured to couple to a nondestructive testing (NDT) sample and configured to produce and direct an ultrasonic probe wave at a selected frequency into a subsurface region of the NDT sample, a 3D laser scanning vibrometer configured to direct a detection beam in a scan area on a surface of the NDT sample and to receive a return beam from the scan area, and to detect, based on the return beam, a 3D motion of the surface across a wideband frequency range, and a processor, and a memory configured with instructions that, when executed by the processor, cause the processor to produce sub-surface image data of the NDT sample at multiple harmonics of the selected frequency in the wideband frequency range based on the detected 3D surface motion, wherein the sub-surface image data describes a nonlinear defect response produced in the NDT sample by interaction of the ultrasonic probe wave with the subsurface region.

Remillieux, Marcel↗

Effect of rice husk ash-derived activator on the structural build-up of alkali activated materials

Highlights: • Filtered and unfiltered sodium silicate solutions were synthesised from RHA. • The dissolution efficiency of RHA in NaOH solution was 76.3%. • RHA-derived activator showed a structural build-up comparable to the commercial activator in AAM pastes. • The undissolved residues in the unfiltered RHA-derived activator increased the yield stress. • Comparable compressive strength and early age gel formation were observed from both commercial and RHA-derived solutions. Waste-derived sodium silicates (SSs) were synthesised from rice husk ash (RHA) to produce alkali activated materials (AAMs) using fly ash and slag as precursors. The effects of these SSs on the structural build-up were investigated by monitoring the evolution of the viscoelasticity, ultrasonic pulse waves, setting time, and infrared spectra. Two types of RHA derived SSs (filtered SS and unfiltered SS) were prepared to investigate the effect of the undissolved residue on the hardening process. The derived SS contained a large portion of monomer silicate species. The results showed that the structural build-up mechanism was comparable between the AAMs activated by the filtered SS and a commercial SS. The unfiltered SS increased the yield stress of the paste by up to 10 times. However, the residues in the unfiltered SS had insignificant impacts on the gel formation and compressive strength when using identical SiO{sub 2}/Na{sub 2}O and Na{sub 2}O/binder ratios in the mix design.

36 MATERIALS SCIENCE↗

Progress on Advancing the Robotic Air-slot Volumetric Inspection System (RAVIS) for Hanford Under-tank Inspection - 20519

The 27 in-service double-shell tank (DST) systems at Hanford provide interim storage for nearly 56 million gallons of nuclear and hazardous chemical legacy waste. The safe and reliable storage of the waste is critical to the site's extended cleanup mission. While in service, the leak integrity of the DSTs must be demonstrated to satisfy the Washington Administrative Code, inform decisions on tank management, and gauge fitness for continued service beyond originally intended design lives. The carbon steel plates and welds that comprise DST primary tank sidewalls and lower knuckles are routinely 'sampled' for volumetric non-destructive testing using ultrasonic inspection technology to determine whether corrosion pitting, cracking, or general corrosion are occurring that could compromise tank leak integrity. However, the carbon steel plates and welds that comprise the bottoms of primary tanks have not been thoroughly inspected since the DSTs were constructed (i.e., since 1968-1986) due to limited physical access to the exterior tank bottoms. The Robotic Air-slot Volumetric Inspection System, or 'RAVIS,' is being engineered to overcome the challenge of tank bottom in-service inspection. The system will be deployed under primary tanks within the small cooling channels/air-slots in the refractory pads upon which the tanks rest and will use ultrasonic guided wave inspection technology to volumetrically inspect physically inaccessible regions that make up ∼90% of a tank bottom, as well as regions that are physically accessible from the air-slots but comprise only ∼10% of a tank bottom. This paper describes the air-slot sensor and robotic deployment system and focuses on the testing approach and methods that are being applied to support (1) design feedback and performance acceptance (requirement verification) and (2) performance repeatability/reliability assessments (qualification) to ensure the RAVIS is prepared for successful inservice inspections of primary tank bottoms. Test progress made against the test plan, the results of 2019 testing, and the future outlook are included. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Adhesive joint evaluation by ultrasonic interface and lamb waves

Some results on the application of interface and Lamb waves for the study of curing of thin adhesive layers were summarized. In the case of thick substrates (thickness much more than the wave length) the interface waves can be used. In this case the experimental data can be inverted and the shear modulus of the adhesive film may be explicitly found based on the measured interface wave velocity. It is shown that interface waves can be used for the study of curing of structural adhesives as a function of different temperatures and other experimental conditions. The kinetics of curing was studied. In the case of thin substrates the wave phenomena are much more complicated. It is shown that for successful measurements proper selection of experimental conditions is very important. This can be done based on theoretical estimations. For correctly selected experimental conditions the Lamb waves may be a sensitive probe of adhesive bond quality and may be used or cure monitoring.

Rokhlin, S. I.↗

Ultrasonic verification of five wave fronts in unidirectional graphite epoxy composite

The existence of five different waves fronts in a unidirectional graphite fiber reinforced epoxy composite with energy flux propagation at the angle of 60 deg with respect to the fiber direction is verified by measuring their corresponding group and phase velocities of longitudinal and shear waves using the through transmission technique. The experimental and theoretical values of phase velocities show excellent agreement for all three modes of wave propagation. It is also verified that the maximum output voltage amplitude is obtained when the line joining the centers of the transmitting and receiving transducers is parallel to the energy propagation direction defined by the deviation angle.

Seng, Han-Song↗

Compressional wave velocities of a lunar regolith sample in a simulated lunar environment

Ultrasonic compressional wave velocities have been measured in the laboratory for an Apollo 15 soil sample (15301, 38) under very low uniaxial stress and high vacuum conditions. The velocities measured range from 125 to 522 m/sec. The velocities of the soil are stress dependent and are strongly affected by compaction history. Hertzian contact theory does not appear to fit the data adequately for the pressure range of the experiment. Moderate increases in temperature do not have a significant effect on the compressional wave velocities.

Johnson, D. M.↗

Detecting Lamb waves with broad-band acousto-ultrasonic signals in composite structures

Lamb waves can be produced and detected in ceramic matrix composites (CMC) and metal matrix composites (MMC) plates using the acousto-ultrasonic configuration employing broadband transducers. Experimental dispersion curves of lowest symmetric and antisymmetric modes behave in a manner analogous to the graphite/polymer theoretical curves. In this study a basis has been established for analyzing Lamb wave velocities for characterizing composite plates. Lamb wave dispersion curves and group velocities were correlated with variations in axial stiffness and shear stiffness in MMC and CMC. For CMC, interfacial shear strength was also correlated with the first antisymmetric Lamb mode.

Kautz, Harold E.↗

Lamb Wave Assessment of Fiber Volume Fraction in Composites

Among the various techniques available, ultrasonic Lamb waves offer a convenient method of examining composite materials. Since the Lamb wave velocity depends on the elastic properties of a material, an effective tool exists to evaluate composites by measuring the velocity of these waves. Lamb waves can propagate over long distances and are sensitive to the desired in-plane elastic properties of the material. This paper discusses a study in which Lamb waves were used to examine fiber volume fraction variations of approximately 0.40-0.70 in composites. The Lamb wave measurements were compared to fiber volume fractions obtained from acid digestion tests. Additionally, a model to predict the fiber volume fraction from Lamb wave velocity values was evaluated.

Seale, Michael D.↗

Lamb Wave Assessment of Fatigue and Thermal Damage in Composites

Among the various techniques available, ultrasonic Lamb waves offer a convenient method of evaluating composite materials. Since the Lamb wave velocity depends on the elastic properties of a structure, an effective tool exists to monitor damage in composites by measuring the velocity of these waves. Lamb wave measurements can propagate over long distances and are sensitive to the desired in-plane elastic properties of the material. This paper describes two studies which monitor fatigue damage and two studies which monitor thermal damage in composites using Lamb waves. In the fatigue studies, the Lamb wave velocity is compared to modulus measurements obtained using strain gage measurements in the first experiment and the velocity is monitored along with the crack density in the second. In the thermal damage studies, one examines samples which were exposed to varying temperatures for a three minute duration and the second includes rapid thermal damage in composites by intense laser beams. In all studies, the Lamb wave velocity is demonstrated to be an excellent method to monitor damage in composites.

Seale, Michael D.↗

Ultrasonic nondestructive evaluation of additively manufactured wear coatings

Here, this work pertains to the nondestructive evaluation of additively deposited coatings using ultrasound measurements. The specific objective was to evaluate using ultrasound surface wave measurements the quality of Stellite 21 coatings deposited on Inconel 718 substrates by the directed energy deposition (DED) additive manufacturing (AM) process. The surface wave speed and diffuse backscatter amplitude of the ultrasound waves were correlated with both cracking and warpage of the coating. This research is important, because, the integrity of DED-processed coatings currently requires a combination of destructive metallographic studies and X-ray computed tomography analysis, which are both expensive and time consuming. Instead of using a normal incidence configuration for the ultrasound measurements, the surface-wave approach allows the inspection of the near surface coating integrity. Three different frequencies were used to excite surface waves because each frequency has a different penetration depth. The signals obtained were used to quantify and compare the surface wave speed and surface wave-diffuse ultrasonic backscatter amplitude from five different DED-processed Stellite coated samples. Considering destructive metallurgical characterization as a reference, surface wave measurements were found to be effective for examining coating integrity. Further, the backscatter amplitude of the surface waves was correlated with the crack density and warpage. These flaws also change the stress state of the Stellite coating and consequently the surface wave propagation speed and its scattering behavior.

36 MATERIALS SCIENCE↗

Least Squares Reverse Time Migration (LSRTM) for Damage Imaging in Composite Laminates

A method for adapting least squares reverse time migration (LSRTM) for ultrasonic guided wave imaging of composite laminates is proposed in this paper. As composites become more widely used in fields such as the aerospace industry, the need for high-resolution imaging in structural health monitoring (SHM) and nondestructive evaluation (NDE) is also growing. For instance, delamination is a common problem in composite laminates, which has led to a certain degree of apprehension in the use of composite materials for load-bearing structures. Although the solver-based imaging techniques using conventional reverse time migration (RTM) methods illuminate damage with a wide range of damage-scattering effects, the resulting images do not fully define the damage regions due to the limited data acquisition aperture, sensor density, frequencies/wavelengths, and incompleteness of adjoint reconstruction. Previously, the LSRTM theory was derived by incorporating a least squares migration (LSM) algorithm into RTM, and benchmarked its high-resolution damage imaging performance for isotropic plates. To improve damage imaging in composite laminates, a process to create an ultrasonic guided wave-based LSRTM method for anisotropic materials is proposed in this paper. The derivation of the forward modeling operator and the adjoint operator is presented. Numerical case studies were conducted to show the improvement of LSRTM over RTM in mapping damage in composite plates. Multiple damage sites or damage with a complex shape were created in the numerical studies based on 1) Born approximation-based modeling or 2) reduction of the plate stiffness-based modeling. LSRTM begins by using a forward modeling process. The forward modeling accuracy for the flexural wave solver used in this study for LSRTM was also compared with the results from a three-dimensional rotated staggered grid (RSG) elastodynamic finite difference solver, previously open-sourced by NASA Langley Research Center. These benchmarking studies have shown that the LSRTM method is more effective in reducing artifacts, improving resolution, and enhancing damage model reconstruction compared to RTM in composite laminates.

Jiaze He↗

Machined phononic crystals to block high-order Lamb waves and crosstalk in through-metal ultrasonic communication systems

For systems that require complete metallic enclosures (e.g., containment buildings for nuclear reactors), it is impossible to access interior sensors and equipment using standard electromagnetic techniques. A viable way to communicate and supply power through metallic barriers is the use of elastic waves and ultrasonic transducers, introducing several design challenges that must be addressed. Specifically, the use of multiple communication channels on the same enclosure introduces an additional mechanism for signal crosstalk between channels: guided waves propagating in the barrier between channels. This work numerically and experimentally investigates a machined phononic crystal to block MHz Lamb wave propagation between ultrasonic communication channels, greatly reducing wave propagation and the resulting crosstalk voltage. Blind grooves are machined into one or both sides of a metallic barrier to introduce a periodic unit cell, greatly altering the guided wave dispersion in the barrier. Numerical simulations are used to determine a set of groove geometries for testing, and experiments were performed to characterize the wave-blocking performance of each design. The best-performing design was tested using piezoelectric transducers bonded to the barrier, showing a 14.4 dB reduction in crosstalk voltage. Overall, the proposed periodic grooving method is a promising technique for completely isolating ultrasonic power/data transfer systems operating in a narrow frequency range.