Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Comparative Performance of Three Eye-Tracking Devices in Detection of Mild Traumatic Brain Injury in Acute Versus Chronic Subject Populations

ABSTRACT Introduction Presently, traumatic brain injury (TBI) triage in field settings relies on symptom-based screening tools such as the updated Military Acute Concussion Evaluation. Objective eye-tracking may provide an alternative means of neurotrauma screening due to sensitivity to neurotrauma brain-health changes. Previously, the US Army Medical Research and Development Command Non-Invasive NeuroAssessment Devices (NINAD) Integrated Product Team identified 3 commercially available eye-tracking devices (SyncThink EYE-SYNC, Oculogica EyeBOX, NeuroKinetics IPAS) as meeting criteria toward being operationally effective in the detection of TBI in service members. We compared these devices to assess their relative performance in the classification of mild traumatic brain injury (mTBI) subjects versus normal healthy controls. Materials and Methods Participants 18 to 45 years of age were assigned to Acute mTBI, Chronic mTBI, or Control group per study criteria. Each completed a TBI assessment protocol with all 3 devices counterbalanced across participants. Acute mTBI participants were tested within 72 hours following injury whereas time since last injury for the Chronic mTBI group ranged from months to years. Discriminant analysis was undertaken to determine device classification performance in separating TBI subjects from controls. Area Under the Curves (AUCs) were calculated and used to compare the accuracy of device performance. Device-related factors including data quality, the need to repeat tests, and technical issues experienced were aggregated for reporting. Results A total of 63 participants were recruited as Acute mTBI subjects, 34 as Chronic mTBI subjects, and 119 participants without history of TBI as controls. To maximize outcomes, poorer quality data were excluded from analysis using specific criteria where possible. Final analysis utilized 49 (43 male/6 female, mean [x̅] age = 24.3 years, SD [s] = 5.1) Acute mTBI subjects, and 34 (33 male/1 female, x̅ age = 38.8 years, s = 3.9) Chronic mTBI subjects were age- and gender-matched as closely as possible with Control subjects. AUCs obtained with 80% of total dataset ranged from 0.690 to 0.950 for the Acute Group and from 0.753 to 0.811 for the Chronic mTBI group. Validation with the remaining 20% of dataset produced AUCs ranging from 0.600 to 0.750 for Acute mTBI group and 0.490 to 0.571 for the Chronic mTBI group. Conclusions Potential eye-tracking detection of mTBI, per training model outcomes, ranged from acceptable to excellent for the Acute mTBI group; however, it was less consistent for the Chronic mTBI group. The self-imposed targeted performance (AUC of 0.850) appears achievable, but further device improvements and research are necessary. Discriminant analysis models differed for the Acute versus Chronic mTBI groups, suggesting performance differences in eye-tracking. Although eye-tracking demonstrated sensitivity in the Chronic group, a more rigorous and/or longitudinal study design is required to evaluate this observation. mTBI injuries were not controlled for this study, potentially reducing eye-tracking assessment sensitivity. Overall, these findings indicate that while eye-tracking remains a viable means of mTBI screening, device-specific variability in data quality, length of testing, and ease of use must be addressed to achieve NINAD objectives and DoD implementation.

General & Internal Medicine↗

Leveraging Topological Events in Tracking Graphs for Understanding Particle Diffusion

Abstract Single particle tracking (SPT) of fluorescent molecules provides significant insights into the diffusion and relative motion of tagged proteins and other structures of interest in biology. However, despite the latest advances in high‐resolution microscopy, individual particles are typically not distinguished from clusters of particles. This lack of resolution obscures potential evidence for how merging and splitting of particles affect their diffusion and any implications on the biological environment. The particle tracks are typically decomposed into individual segments at observed merge and split events, and analysis is performed without knowing the true count of particles in the resulting segments. Here, we address the challenges in analyzing particle tracks in the context of cancer biology. In particular, we study the tracks of KRAS protein, which is implicated in nearly 20% of all human cancers, and whose clustering and aggregation have been linked to the signaling pathway leading to uncontrolled cell growth. We present a new analysis approach for particle tracks by representing them as tracking graphs and using topological events – merging and splitting, to disambiguate the tracks. Using this analysis, we infer a lower bound on the count of particles as they cluster and create conditional distributions of diffusion speeds before and after merge and split events. Using thousands of time‐steps of simulated and in‐vitro SPT data, we demonstrate the efficacy of our method, as it offers the biologists a new, detailed look into the relationship between KRAS clustering and diffusion speeds.

McDonald, T.↗

A measurement technique to determine the calibration accuracy of an electromagnetic tracking system to radiation isocenter

Purpose: To present and characterize a measurement technique to quantify the calibration accuracy of an electromagnetic tracking system to radiation isocenter.Methods: This technique was developed as a quality assurance method for electromagnetic tracking systems used in a multi-institutional clinical hypofractionated prostate study. In this technique, the electromagnetic tracking system is calibrated to isocenter with the manufacturers recommended technique, using laser-based alignment. A test patient is created with a transponder at isocenter whose position is measured electromagnetically. Four portal images of the transponder are taken with collimator rotations of 45° 135°, 225°, and 315°, at each of four gantry angles (0°, 90°, 180°, 270°) using a 3 × 6 cm{sup 2} radiation field. In each image, the center of the copper-wrapped iron core of the transponder is determined. All measurements are made relative to this transponder position to remove gantry and imager sag effects. For each of the 16 images, the 50% collimation edges are identified and used to find a ray representing the rotational axis of each collimation edge. The 16 collimator rotation rays from four gantry angles pass through and bound the radiation isocenter volume. The center of the bounded region, relative to the transponder, is calculated and then transformed to tracking system coordinates using the transponder position, allowing the tracking system's calibration offset from radiation isocenter to be found. All image analysis and calculations are automated with inhouse software for user-independent accuracy. Three different tracking systems at two different sites were evaluated for this study.Results: The magnitude of the calibration offset was always less than the manufacturer's stated accuracy of 0.2 cm using their standard clinical calibration procedure, and ranged from 0.014 to 0.175 cm. On three systems in clinical use, the magnitude of the offset was found to be 0.053 ± 0.036, 0.121 ± 0.023, and 0.093 ± 0.013 cm.Conclusions: The method presented here provides an independent technique to verify the calibration of an electromagnetic tracking system to radiation isocenter. The calibration accuracy of the system was better than the 0.2 cm accuracy stated by the manufacturer. However, it should not be assumed to be zero, especially for stereotactic radiation therapy treatments where planning target volume margins are very small.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-394: The Use of Jaw Tracking in Intensity Modulated and Volumetric Modulated Arc Radiotherapy for Spine Stereotactic Radiosurgery

Purpose: To evaluate the potential advantages of jaw tracking for intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) in spine radiosurgery. Methods: VMAT and IMRT plans were retrospectively generated for ten patients. Six plans for each patient were created in the Eclipse treatment planning system for a Varian Truebeam equipped with a Millennium 120 MLC. Plans were created to study IMRT and VMAT plans with and without jaw tracking, as well as IMRT plans of different flattening filter free (FFF) energies. Plans were prescribed to the 90% isodose line to 16 or 18 Gy in one fraction to cover 95% of the target. Planning target volume (PTV) coverage, conformity index (CI), dose to spinal cord, distance to fall off from the 90% to 50% isodose line (DTF), as well as delivery time were evaluated. Ion chamber and film measurements were performed to verify calculated and measured dose distributions. Results: Jaw tracking decreased the spinal cord dose for both IMRT and VMAT plans, but a larger decrease was seen with the IMRT plans (p=0.004 vs p=0.04). The average D10% for the spinal cord was least for the 6MV FFF IMRT plan with jaw tracking and was greatest for the 10MV FFF plan without jaw tracking. Treatment times between IMRT and VMAT plans with or without jaw tracking were not significantly different. Measured plans showed greater than 98.5% agreement for planar dose gamma analysis (3%/2 mm) and less than 2.5% for point dose analysis compared to calculated plans. Conclusion: Jaw tracking can be used to help decrease spinal cord dose without any change in treatment delivery or calculation accuracy. Lower dose to the spinal cord was achieved using 6 MV beams compared to 10 MV beams, though 10 MV may be justified in some cases to decrease skin dose.

60 APPLIED LIFE SCIENCES↗

TH-E-17A-10: Markerless Lung Tumor Tracking Based On Beams Eye View EPID Images

Purpose: Dynamic tumor tracking or motion compensation techniques have proposed to modify beam delivery following lung tumor motion on the flight. Conventional treatment plan QA could be performed in advance since every delivery may be different. Markerless lung tumor tracking using beams eye view EPID images provides a best treatment evaluation mechanism. The purpose of this study is to improve the accuracy of the online markerless lung tumor motion tracking method. Methods: The lung tumor could be located on every frame of MV images during radiation therapy treatment by comparing with corresponding digitally reconstructed radiograph (DRR). A kV-MV CT corresponding curve is applied on planning kV CT to generate MV CT images for patients in order to enhance the similarity between DRRs and MV treatment images. This kV-MV CT corresponding curve was obtained by scanning a same CT electron density phantom by a kV CT scanner and MV scanner (Tomotherapy) or MV CBCT. Two sets of MV DRRs were then generated for tumor and anatomy without tumor as the references to tracking the tumor on beams eye view EPID images. Results: Phantom studies were performed on a Varian TrueBeam linac. MV treatment images were acquired continuously during each treatment beam delivery at 12 gantry angles by iTools. Markerless tumor tracking was applied with DRRs generated from simulated MVCT. Tumors were tracked on every frame of images and compared with expected positions based on programed phantom motion. It was found that the average tracking error were 2.3 mm. Conclusion: This algorithm is capable of detecting lung tumors at complicated environment without implanting markers. It should be noted that the CT data has a slice thickness of 3 mm. This shows the statistical accuracy is better than the spatial accuracy. This project has been supported by a Varian Research Grant.

60 APPLIED LIFE SCIENCES↗

Registration of clinical volumes to beams-eye-view images for real-time tracking

Purpose: The authors combine the registration of 2D beam’s eye view (BEV) images and 3D planning computed tomography (CT) images, with relative, markerless tumor tracking to provide automatic absolute tracking of physician defined volumes such as the gross tumor volume (GTV). Methods: During treatment of lung SBRT cases, BEV images were continuously acquired with an electronic portal imaging device (EPID) operating in cine mode. For absolute registration of physician-defined volumes, an intensity based 2D/3D registration to the planning CT was performed using the end-of-exhale (EoE) phase of the four dimensional computed tomography (4DCT). The volume was converted from Hounsfield units into electron density by a calibration curve and digitally reconstructed radiographs (DRRs) were generated for each beam geometry. Using normalized cross correlation between the DRR and an EoE BEV image, the best in-plane rigid transformation was found. The transformation was applied to physician-defined contours in the planning CT, mapping them into the EPID image domain. A robust multiregion method of relative markerless lung tumor tracking quantified deviations from the EoE position. Results: The success of 2D/3D registration was demonstrated at the EoE breathing phase. By registering at this phase and then employing a separate technique for relative tracking, the authors are able to successfully track target volumes in the BEV images throughout the entire treatment delivery. Conclusions: Through the combination of EPID/4DCT registration and relative tracking, a necessary step toward the clinical implementation of BEV tracking has been completed. The knowledge of tumor volumes relative to the treatment field is important for future applications like real-time motion management, adaptive radiotherapy, and delivered dose calculations.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-07: Development of a Programmable Motion Testbed for the Validation of Ultrasound Tracking Algorithms

Purpose: To develop an advanced testbed that combines a 3D motion stage and ultrasound phantom to optimize and validate 2D and 3D tracking algorithms for real-time motion management during radiation therapy. Methods: A Siemens S2000 Ultrasound scanner utilizing a 9L4 transducer was coupled with the Washington University 4D Phantom to simulate patient motion. The transducer was securely fastened to the 3D stage and positioned to image three cylinders of varying contrast in a Gammex 404GS LE phantom. The transducer was placed within a water bath above the phantom in order to maintain sufficient coupling for the entire range of simulated motion. A programmed motion sequence was used to move the transducer during image acquisition and a cine video was acquired for one minute to allow for long sequence tracking. Images were analyzed using a normalized cross-correlation block matching tracking algorithm and compared to the known motion of the transducer relative to the phantom. Results: The setup produced stable ultrasound motion traces consistent with those programmed into the 3D motion stage. The acquired ultrasound images showed minimal artifacts and an image quality that was more than suitable for tracking algorithm verification. Comparisons of a block matching tracking algorithm with the known motion trace for the three features resulted in an average tracking error of 0.59 mm. Conclusion: The high accuracy and programmability of the 4D phantom allows for the acquisition of ultrasound motion sequences that are highly customizable; allowing for focused analysis of some common pitfalls of tracking algorithms such as partial feature occlusion or feature disappearance, among others. The design can easily be modified to adapt to any probe such that the process can be extended to 3D acquisition. Further development of an anatomy specific phantom better resembling true anatomical landmarks could lead to an even more robust validation. This work is partially funded by NIH grant R01CA190298.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-08: Robotic System for Ultrasound Tracking in Radiation Therapy

Purpose: For safe and accurate real-time tracking of tumors for IGRT using 4D ultrasound, it is necessary to make use of novel, high-end force-sensitive lightweight robots designed for human-machine interaction. Such a robot will be integrated into an existing robotized ultrasound system for non-invasive 4D live tracking, using a newly developed real-time control and communication framework. Methods: The new KUKA LWR iiwa robot is used for robotized ultrasound real-time tumor tracking. Besides more precise probe contact pressure detection, this robot provides an additional 7th link, enhancing the dexterity of the kinematic and the mounted transducer. Several integrated, certified safety features create a safe environment for the patients during treatment. However, to remotely control the robot for the ultrasound application, a real-time control and communication framework has to be developed. Based on a client/server concept, client-side control commands are received and processed by a central server unit and are implemented by a client module running directly on the robot’s controller. Several special functionalities for robotized ultrasound applications are integrated and the robot can now be used for real-time control of the image quality by adjusting the transducer position, and contact pressure. The framework was evaluated looking at overall real-time capability for communication and processing of three different standard commands. Results: Due to inherent, certified safety modules, the new robot ensures a safe environment for patients during tumor tracking. Furthermore, the developed framework shows overall real-time capability with a maximum average latency of 3.6 ms (Minimum 2.5 ms; 5000 trials). Conclusion: The novel KUKA LBR iiwa robot will advance the current robotized ultrasound tracking system with important features. With the developed framework, it is now possible to remotely control this robot and use it for robotized ultrasound tracking applications, including image quality control and target tracking.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRA-08: Simulated Tumor Tracking in An MRI Linac for Lung Tumor Lesions Using the Monaco Treatment Planning System

Purpose: To simulate tumor tracking in an Elekta MRI-linac (MRL) and to compare this tracking method with our current ITV approach in terms of OAR sparing for lung cancer patients. Methods: Five SABR-NSCLC patients with central lung tumors were selected for reasons of potential enhancement of tumor-tissue delineation using MRI. The Monaco TPS was used to compare the current clinical ITV approach to a simulated, novel tracking method which used a 7MV MRL beam in the presence of an orthogonal 1.5 T magnetic field (4D-MRL method). In the simulated tracking scenario, achieved using the virtual couch shift (VCS), the PTV was defined using an isotropic 5mm margin applied to the GTV of each phase, as acquired from an 8-phase amplitude-binned 4DCT. These VCS plans were optimized and weighted on each phase. The dose weighting was performed using the patient-specific breathing traces. The doses were accumulated on the inhale phase. The two methods were compared by assessing the OAR DVHs. Results: The 4D-MRL method resulted in a reduced target volume (by an average of 29% over all patients). The benefits of using an MRL tracking system depended on the tumor motion amplitude and the relative OAR motion (ROM) to the target. The reduction in mean doses to parallel organs was up to 3 Gy for the heart and 2.1 Gy for the lung. The reductions in maximum doses to serial organs were up to 9.4 Gy, 5.6 Gy, and 8.7 Gy for the esophagus, spinal cord, and the trachea, respectively. Serial organs benefited from MRL tracking when the ROM was ≥ 0.3 cm despite small tumor motion amplitude in some cases. Conclusions: This work demonstrated the potential benefit for an MRL tracking system to spare OARs in SABR-NSCLC patients with central tumors. The benefits are embodied in the target volume reduction. This project was made possible with the financial support of Elekta.

60 APPLIED LIFE SCIENCES↗

Primary track recovery in high-definition gas time projection chambers

Abstract We develop and validate a new algorithm called primary track recovery () that effectively deconvolves known physics and detector effects from nuclear recoil tracks in gas time projection chambers (TPCs) with high-resolution readout. This gives access to the primary track charge, length, and vector direction (helping to resolve the “head-tail” ambiguity). Additionally, provides a measurement of the transverse and longitudinal diffusion widths, which can be used to determine the absolute position of tracks in the drift direction for detector fiducialization. Using simulated helium recoils in an atmospheric pressure TPC with a 70:30 mixture of $$\hbox {He:CO}_2$$ He:CO 2 we compare the performance of to traditional methods for all key track variables. We find that the algorithm reduces reconstruction errors, including those caused by charge integration, for tracks with mean length-to-width ratios 1.4 and above, corresponding to recoil energies of 20 keV and above in the studied TPCs. We show that improves on existing methods for head-tail disambiguation, particularly for highly inclined tracks, and improves the determination of the absolute position of recoils on the drift axis via transverse diffusion. We find that can partially recover charge structure integrated out by the detector in the z direction, but that its determination of energy and length have worse resolution compared to existing methods. We use experimental data to qualitatively verify these findings and discuss implications for future directional detectors at the low-energy frontier.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tracking of Polycarbonate Films using Low-energy Ions Final Report CRADA No. TC-774-94

Ion tracking is performed almost exclusively using ions with energies near or above the maximum in electronic stopping. For the present study, we have examined the results of etching ion tracks created by ions bombarding polycarbonate films with energies corresponding to stopping well below the maximum and just above the anticipated threshold for creating etchable latent tracks. Low-energy neon and argon ions with 18-60 keV /amu and fluences of about 10 8 /cm 2 were used to examine the limits for producing etchable tracks in polycarbonate films. By concentrating on the early stages of etching (i.e., -20 nm < SEM hole diameter < -100 nm), we can directly relate the energy deposition calculated for the incident ion to the creation of etchable tracks. The experimental results will be discussed with regard to the energy losses of the ions in the polycarbonate films and to the formation of continuous latent tracks through the entire thickness the films. These results have significant implications with respect to the threshold for formation of etchable tracks and to the use of low-energy ions for lithographic applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dark Matter and Track Triggering with the CMS Experiment (Final Report)

This report summarizes the progress from DOE Early Career Award entitled “Dark Matter and Track Triggering with the CMS Experiment”. The first major goal of the project was to establish a sensitive Dark Matter (DM) search program for the CMS experiment in Run-2 of the LHC. Two related strategies were developed to accomplish this goal. First, we designed and executed searches for DM produced in association with heavy flavor quark pairs, top/anti-top (ttbar) and bottom/anti-bottom (bbbar). In addition, we sought to maximize the power of Run-2 DM searches through the development of a statistical combination of all major search channels within a consistent theoretical framework. The results of these aspects of the project are detailed in Section 1. The second major goal of the project was to develop a real-time “Level-1” tracking trigger system for the high-luminosity LHC (HL-LHC) CMS upgrade. Charged particle tracking in the first stage of the CMS trigger will be crucial for surviving the high-pileup environment expected at the HL-LHC. The L1 tracking trigger must process all front-end hit data sent from the inner Tracker and will have just 4us to output track primitives to the downstream L1 trigger without data loss. Our development of the CMS tracking trigger is described in Section 2. The team supported by the award is given in Section 3. The project resulted in 10 peer reviewed publications, a graduate student thesis, and contributions to the CMS Phase-2 Tracker Technical Design Report, as is detailed in Section 4. Our development work for the CMS tracking trigger has been integrated in the backend system architecture for the Tracker upgrade.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Predicting Missing Regions in Charged Particle Tracks Using a Sparse 3D Convolutional Neural Network

The 2x2 Demonstrator is a prototype detector for the Deep Underground Neutrino Experiment (DUNE)'s Near Detector. Both the 2x2 Demonstrator and the Near Detector itself will have inactive regions wherein there is no sensitivity to charge deposition and light signals that arise from charged particle interactions with liquid argon. In the 2x2, these inactive regions are positioned in-between the active detector modules, which introduces the challenge of inferring what charge signals ought to look like in these regions. This study explores the use of a Sparse 3D Convolutional Neural Network (ConvNet) to infer missing regions in charged particle tracks. Hits corresponding to energy depositions are voxelized into a three-dimensional (3D) grid for each track. Inactive regions within the tracks are replaced with a dense, rectangular 3D grid of voxels, ensuring consistent step sizes in X, Y, and Z directions. Voxels in these dense regions are initialized with an energy value of -1, indicating nonphysical energy or charge. The model is trained to predict which voxels should activate as part of the track and which should not, with the goal of eventually inferring the missing charge or energy values in these voxels. Results indicate that the model accurately predicts track voxels within ±1 unit in X, Y, or Z directions and effectively identifies non-track voxels, despite some overprediction. The approach shows promise in prediction of missing track regions with some accuracy.

43 PARTICLE ACCELERATORS↗

Application of new radio tracking data types to critical spacecraft navigation problems

Earth-based radio tracking data types are considered, which involve simultaneous or nearly simultaneous spacecraft tracking from widely separated tracking stations. These data types are conventional tracking instrumentation analogs of the very long baseline interferometry (VLBI) of radio astronomy-hence the name quasi-VLBI. A preliminary analysis of quasi-VLBI is presented using simplified tracking data models. The results of accuracy analyses are presented for a representative mission, Viking 1975. The results indicate that, contingent on projected tracking system accuracy, quasi-VLBI can be expected to significantly improve navigation performance over that expected from conventional tracking data types.

Ondrasik, V. J.↗

Effect of cursor characteristics on pilots' tracking performance on a cathode-ray tube in dynamic simulation

The effects of cursor configuration, size, and orientation on the performance of 11 commercial airline pilots were investigated in a difficult compensatory tracking task in a moving-base aircraft simulator. Three levels of congruent cab motion (0, 1, and 2 times the visual motion) were superimposed on the tracking task. Data analysis of the mean tracking error scores revealed no significant effects of cursor size, orientation, or configuration on pilots' tracking performance. Mean tracking error did not significantly differ between the three levels of motion for the conditions with a single dot as the cursor. However, for the dotted and solid line cursors, tracking error significantly decreased from the no motion condition to the motion conditions. The addition of simulator motion significantly reduced tracking error for large cursors, but not for small ones such as a single dot

Junge, M. K.↗

A comparison of tracking with visual and kinesthetic-tactual displays

Recent research on manual tracking with a kinesthetic-tactual (KT) display suggests that under appropriate conditions it may be an effective means of providing visual workload relief. In order to better understand how KT tracking differs from visual tracking, both a critical tracking task and stationary single-axis tracking tasks were conducted with and without velocity quickening. On the critical tracking task, the visual displays were superior; however, the KT quickened display was approximately equal to the visual unquickened display. Mean squared error scores in the stationary tracking tasks for the visual and KT displays were approximately equal in the quickened conditions, and the describing functions were very similar. In the unquickened conditions, the visual display was superior. Subjects using the unquickened KT display exhibited a low frequency lead-lag that may be related to sensory adaptation.

Jagacinski, R. J.↗

A comparison of visual and kinesthetic-tactual displays for compensatory tracking

Recent research on manual tracking with a kinesthetic-tactual (KT) display suggests that under certain conditions it can be an effective alternative or supplement to visual displays. In order to understand better how KT tracking compares with visual tracking, both a critical tracking and stationary single-axis tracking tasks were conducted with and without velocity quickening. In the critical tracking task, the visual displays were superior, however, the quickened KT display was approximately equal to the unquickened visual display. In stationary tracking tasks, subjects adopted lag equalization with the quickened KT and visual displays, and mean-squared error scores were approximately equal. With the unquickened displays, subjects adopted lag-lead equalization, and the visual displays were superior. This superiority was partly due to the servomotor lag in the implementation of the KT display and partly due to modality differences.

Jagacinski, R. J.↗

Gravity model improvement using the DORIS tracking system on the SPOT 2 satellite

A high-precision radiometric satellite tracking system, Doppler Orbitography and Radio-positioning Integrated by Satellite system (DORIS), has recently been developed by the French space agency, Centre National d'Etudes Spatiales (CNES). DORIS was designed to provide tracking support for missions such as the joint United States/French TOPEX/Poseidon. As part of the flight testing process, a DORIS package was flown on the French SPOT 2 satellite. A substantial quantity of geodetic quality tracking data was obtained on SPOT 2 from an extensive international DORIS tracking network. These data were analyzed to assess their accuracy and to evaluate the gravitational modeling enhancements provided by these data in combination with the Goddard Earth Model-T3 (GEM-T3) gravitational model. These observations have noise levels of 0.4 to 0.5 mm/s, with few residual systematic effects. Although the SPOT 2 satellite experiences high atmospheric drag forces, the precision and global coverage of the DORIS tracking data have enabled more extensive orbit parameterization to mitigate these effects. As a result, the SPOT 2 orbital errors have been reduced to an estimated radial accuracy in the 10-20 cm RMS range. The addition of these data, which encompass many regions heretofore lacking in precision satellite tracking, has significantly improved GEM-T3 and allowed greatly improved orbit accuracies for Sun-synchronous satellites like SPOT 2 (such as ERS 1 and EOS). Comparison of the ensuing gravity model with other contemporary fields (GRIM-4C2, TEG2B, and OSU91A) provides a means to assess the current state of knowledge of the Earth's gravity field. Thus, the DORIS experiment on SPOT 2 has provided a strong basis for evaluating this new orbit tracking technology and has demonstrated the important contribution of the DORIS network to the success of the TOPEX/Poseidon mission.

Nerem, R. S.↗