Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Azimuthal radiometric temperature measurements of wheat canopies

The effects of azimuthal view angle on the radiometric temperature of wheat canopies at various stages of development are investigated. Measurements of plant height, total leaf area index, green leaf area index and Feeks growth stage together with infrared radiometric temperature measurements at 12 azimuth intervals with respect to solar azimuth and at different solar zenith angles were obtained for four wheat canopies at various heights. Results reveal a difference on the order of 2 C between the temperatures measured at azimuths of 0 and 180 deg under calm wind conditions, which is attributed to the time-dependent transfer of heat between canopy component surfaces. The azimuthal dependence must thus be taken into account in the determination of radiometric temperatures.

Kimes, D. S.↗

High-resolution surface temperature measurements on rotating turbine blades with an infrared pyrometer

A high-resolution pyrometer was developed and tested on a modified turbine engine. The pyrometer was used to obtain temperature profiles of the viewed surface of turbine blades in the engine at tip speeds up to 366 meters per second. The combination of coherent fiber optics, a silicon avalanche detector, and high-speed electronics enabled surface resolution of a spot diameter of 0.05 centimeter. The data, in the form of temperature profiles, was obtained in near real time as a hard copy output from a computer display terminal. Temperatures measured with the pyrometer and with thermocouples agreed within 2 percent at temperatures between 977 to 1144 K.

Uguccini, O. W.↗

Robust Carbon Dioxide Plume Imaging Using Joint Tomographic Inversion of Seismic Onset Time and Distributed Pressure and Temperature Measurements (Final Report)

We develop and demonstrate rapid and cost-effective methodologies for spatiotemporal tracking of CO2 plumes during geologic sequestration using joint inversion of seismic data and distributed pressure and temperature measurements. Key elements of our methodology are: (a) a computationally efficient approach to pressure and temperature propagation, (b) analysis of time lapse seismic data using a novel ‘seismic onset time’ approach to detect fluid front propagation, and (c) data assimilation and uncertainty assessment via joint inversion of pressure, temperature and time lapse seismic data, and (d) validating the numerical tomographic inversion using a CO2 injection demonstration projects, specifically data collected from the from the Petra Nova Parish Holdings CCUS project in the West Ranch Field, Texas and the Chester-16 reef CO2 injection site in Northern Michigan which is part of the DOE Midwestern Carbon Sequestration Project. The research team is led by Texas A&M University and includes Battelle as a subcontractor with support from Shell, Anadarko, Chevron and JX Nippon. A carbon dioxide (CO2) water-alternating-gas (WAG) pilot was conducted to gain insights into tertiary oil recovery potential via CO2 flood in the West Ranch Field as part of the Petra Nova project, the world’s largest post-combustion CO2 capture and utilization initiative. With a fluvial formation geology and large contrasts in permeability, this is a challenging and novel application of CO2 enhanced oil recovery (EOR). We build a predictive dynamic model of the subsurface that incorporates the multiphase and compositional data acquired during the pilot operation. The calibrated model is used for the carbon dioxide plume imaging. The study began with an initialization of the pilot sector model extracted from a calibrated full-field model. The pilot model calibration follows a two-step hierarchical workflow. First, we performed a large-scale update of the permeability distribution by integrating available bottomhole pressure and multiphase production data. In the second step, local permeability field is fine-tuned using a streamline-based method to match CO2 breakthrough times at the producers. The predictive capability of the calibrated model was verified through two blind validation tests: (1) the model showed good agreement with saturation logs acquired at two observation wells; and (2) the model reproduced the CO2 recovery as a fraction of the injected CO2. The use of seismic onset times has shown great promise for integrating near-continuous seismic surveys for updating geologic models. In this study, we analyze the impact of seismic survey frequency on the onset time approach aiming to extend the application of onset time to infrequent seismic surveys. In addition, we quantitatively examine the nonlinearity of the onset time method and compare it to the commonly used amplitude inversion method. We carry out a sensitivity analysis of seismic survey frequency based on the complete seismic survey data (over 175 surveys) of steam injection in a heavy oil reservoir (Peace River Unit) in Canada. Our results show that an adequate onset time map can be obtained from the infrequent seismic surveys by interpolation between seismic surveys as long as there is no change in the dominant underlying physics between the successive surveys. The study also shows that nonlinearity of the onset time method can be -smaller than that of the amplitude inversion method by several orders of magnitude. Application to the Brugge benchmark case shows that the onset time method obtains comparable permeability update as the traditional seismic amplitude inversion method with faster computation and improved convergence characteristics. We extend the streamline-based data integration approach to incorporate distributed temperature sensor (DTS) data using the concept of thermal tracer travel time. Then, a hierarchical workflow composed of evolutionary and streamline methods is employed to jointly history match the DTS and pressure data. Finally, CO2 saturation and streamline maps are used to visualize the CO2 plume movement during the sequestration process. The hierarchical workflow is applied to a carbon sequestration project in a carbonate reef reservoir within the Northern Niagaran Pinnacle Reef Trend in Michigan, USA. The monitoring data set consists of distributed temperature sensing (DTS) data acquired at the injection well and a monitoring well, flowing bottom-hole pressure data at the injection well, and time-lapse pressure measurements at several locations along the monitoring well. The history matching results indicate that the CO2 movement is mostly restricted to the intended zones of injection which is consistent with an independent warm-back analysis of the temperature data. In addition to employing simulation models and inverse methods for CO2 plume imaging, we also initialized a data-driven technology for detecting inter-well connectivity based on production and pressure data. Our machine-learning framework is built on the statistical recurrent unit (SRU) model and interprets well-based injection/production data into inter-well connectivity without relying on a geologic model. We test it on synthetic and field-scale CO2 EOR projects utilizing the water-alternating-gas (WAG) process. The validation of the proposed data-driven inter-well connectivity assessment is performed using synthetic data from simulation models where inter-well connectivity can be easily measured using the streamline-based flux allocation. The SRU model is shown to offer excellent prediction performance on the synthetic case. Despite significant measurement noise and frequent well shut-ins imposed in the field-scale case, the SRU model offers good prediction accuracy, the overall relative error of the phase production rates at most producers ranges from 10% to 30%. It is shown that the dominant connections identified by the data-driven method and streamline method are in close agreement. Texas A&M University, the lead organization in the project, was primarily responsible for the development of tomographic approaches for CO2 plume mapping in conjunction with distributed pressure, temperature and seismic onset time data. Battelle, as a subcontractor, was primarily responsible for the development of analytical and empirical methods for analyzing transient injection rate and pressure data from point/line sources such as injection and monitoring wells. An additional area of emphasis for Battelle was the use of machine learning for such tasks as inferring reservoir connectivity information from injection-production data, and identifying variable importance for machine learning-based proxy models developed from full-physics simulations. The two organizations also collaborated on the application of the tomographic inversion methodology for a field data set.

02 PETROLEUM↗

Soil moisture from temperature measurements at the Earth's surface, update

Soil moisture budgets at the Earth's surface were investigated based on soil and atmospheric temperature variations. A number of data sets were plotted and statistically analyzed in order to accentuate the existence and the characteristics of mesoscale soil temperature extrema variations and their relations to other parameters. The correlations between diurnal temperature extrema for air and soil in drought and non-drought periods appear to follow different characteristic patterns, allowing an inference of soil moisture content from temperature data. The recovery of temperature extrema after a precipitation event also follows a characteristic power curve rise between two limiting values which is an indicator of evaporation rates. If these indicators are applied universally to regional temperature data, soil moisture content or drought conditions can be inferred directly from temperature measurements.

Welker, J. E.↗

Gas temperature measurements using the dual-line detection Rayleigh scattering technique

A new laser-induced Rayleigh scattering method is presented for the improved temperature diagnostics of gas flows. In the present technique, the two lines of a copper vapor laser are used to obtain the time and space resolved temperature. A single set of optics is used to form the optical probe and to collect the signal simultaneously from both the 510 nm and the 578 nm lines. The dual-line detection allows for the determination and removal of surface-scattered laser light from a Rayleigh signal thereby improving the applicability of Rayleigh scattering to near wall flows with a high degree of glare. An optical system using the dual-line detection technique is built, calibrated and tested in a hot air jet under various levels of background contamination. The results indicate that highly accurate temperature measurements are possible even when the laser-line background intensity, captured by the collecting optics, is five times that of the Rayleigh signal.

Otugen, M. Volkan↗

Gas temperature measurements using the dual-line detection Rayleigh scattering technique

A new laser-induced Rayleigh scattering method is presented for the improved temperature diagnostics of gas flows. In the present technique, the two lines of a copper vapor laser are used to obtain the time and space resolved temperature. A single set of optics is used to form the optical probe and to collect the signal simultaneously from both the 510 nm and the 578 nm lines. The dual-line detection allows for the determination and removal of surface-scattered laser light from a Rayleigh signal thereby improving the applicability of Rayleigh scattering to near wall flows with a high degree of glare. An optical system using the dual-line detection technique is built, calibrated and tested in a hot air jet under various levels of background contamination. The results indicate that highly accurate temperature measurements are possible even when the laser-line background intensity, captured by the collecting optics, is five times that of the Rayleigh signal.

Otugen, M. V.↗

The role of fiberoptics in remote temperature measurement

The use of optical fibers in conjunction with infrared detectors and signal processing electronics represents the latest advance in the field of non-contact temperature measurement and control. The operating principles and design of fiber-optic radiometric systems are discussed and the advantages and disadvantages of using optical fibers are addressed. Signal processing requirements and various infrared detector types are also described. Several areas in which infrared fiber-optic instrumentation is used for temperature monitoring and control are discussed.

Vanzetti, Riccardo↗

One-dimensional air temperature measurements by air resonance enhanced multiphoton Ionization thermometry (ART)

In this work, a detailed calibration study is performed to establish non-intrusive one-dimensional (1D) rovibrational temperature measurements in unseeded air, based on air resonance enhanced multiphoton ionization thermometry (ART). ART is generated by REMPI (resonance enhanced multi-photon ionization) of molecular oxygen and subsequent avalanche ionization of molecular nitrogen in a single laser pulse. ART signal, the fluorescence from the first negative band of molecular nitrogen, is directly proportional to the 2-photon transition of molecular oxygen C 3 Π (v = 2) ← X 3 Σ (v’=0), which is used to determine temperature. Experimentally, hyperfine structures of the O 2 rotational branches with high temperature sensitivity are selectively excited through a frequency-doubled dye laser. Electron-avalanche ionization of N 2 results in the fluorescence emissions from the first negative bands of N 2 + near 390, 425, and 430nm, which are captured as a 1D line by a gated intensified camera. Post processing of the N 2 + fluorescence yields a 1D thermometry line that is representative of the air temperature. It is demonstrated that the technique provides ART fluorescence of ∼5cm in length in the unseeded air, presenting an attractive thermometry solution for high-speed wind tunnels and other ground test facilities.

42 ENGINEERING↗

Turbine gas temperature measurement and control system

A fluidic Turbine Inlet Gas Temperature (TIGIT) Measurement and Control System was developed for use on a Pratt and Whitney Aircraft J58 engine. Based on engine operating requirements, criteria for high temperature materials selection, system design, and system performance were established. To minimize development and operational risk, the TIGT control system was designed to interface with an existing Exhaust Gas Temperature (EGT) Trim System and thereby modulate steady-state fuel flow to maintain a desired TIGT level. Extensive component and system testing was conducted including heated (2300F) vibration tests for the fluidic sensor and gas sampling probe, temperature and vibration tests on the system electronics, burner rig testing of the TIGT measurement system, and in excess of 100 hours of system testing on a J58 engine. (Modified author abstract)

Webb, W. L.↗

Noncontact true temperature measurement, 2

A laser pyrometer was developed for acquiring the true temperature of a levitated sample. The reflectivity is measured by first expanding the laser beam to cover the entire cross-sectional surface of the diffuse target. The reflectivity calibration of this system is determined from the surface emissivity of a target with a blackbody cavity. The emissivity of the real target can then be calculated. The overall system constant is obtained by passively measuring the radiance of the blackbody cavity (emissivity = 1.0) at a known, arbitrary temperature. Since the photosensor used is highly linear over the entire operating temperature range, the true temperature of the target can then be computed. The latest results available from this on-going research indicate that true temperatures thus obtained are in very good quantitative agreement with thermocouple measured temperatures.

Lee, Mark C.↗

Temperature Measurements Reveal Accretion Of Ice On Airfoils

Method of detecting accretion of ice on airfoil based on measurement of difference between temperatures at icing and nonicing locations on airfoil. Release of latent heat of fusion gives rise to characteristic gradient of temperature. Temperatures and difference between them measured by use of contact sensors or remote sensor. Measurements used to trigger alarms and/or deicing equipment.

Hansman, Robert J., Jr.↗

Further development of the dynamic gas temperature measurement system

A compensated thermocouple measurement method was experimentally verified. Dynamic signal content from an atmospheric pressure laboratory burner was measured by the dynamic temperature sensor and a relatively delicate fine-wire resistance thermometer. Compensated data from the two dynamic temperature sensor thermoelements were compared with the compensated fine-wire data in the frequency domain. Absolute differences between spectral line amplitudes measured with different sensors are small relative to the mean temperature and verify the compenation method. Increases in precision of the measurement method require optimization of several factors, and directions for further work are identified.

Elmore, D. L.↗

Temperature Measurements in Hypersonic Wind Tunnels via Femtosecond Coherent Anti-Stokes Raman Scattering

A femtosecond coherent anti-Stokes Raman scattering (fs CARS) instrument is developed to perform gas-phase thermometry in cold-flow hypersonic wind tunnels. Measurements are reported for Mach 8 and 14 pure-nitrogen flows. The fs CARS instrument includes a 100 fs pump/Stokes pulse and a spectrally narrow probe pulse from a second harmonic bandwidth compressor. Important experimental considerations such as limits on the pump/Stokes pulse energy are discussed. The fs CARS focusing and collimating optics are mounted on a two-axis translation stage system to scan the measurement location during a 30 second wind tunnel run. Single-laser-shot rotational CARS spectra are recorded at the laser repetition rate of 1 kHz in the wind tunnel freestream and near simple cone models. Spectral fitting is used to determine quantitative gas temperatures. Freestream temperatures at Mach 8 and 14 spanned ranges of 40–75 and 35–50 K, respectively, depending on tunnel operating conditions. Temperature variations across the central 100 mm span of the wind tunnel were quantified. Measured temperature jumps across conical bow shocks from various models varied by less than 1% from predicted values. Hypersonic boundary layer measurements were demonstrated. In conclusion, these measurements illustrate the utility and robustness of this instrument for the study of complex fluid flow phenomena in challenging ground test facilities.

Aerodynamics↗

Tangential extreme ultraviolet and soft x-ray diagnostic system for time-resolved temperature measurement on the High Beta Tokamak-Extended Pulse

The High Beta Tokamak-Extended Pulse has recently incorporated a tangential multi-energy extreme ultraviolet and soft x-ray diagnostic system. This system enables measurements of the electron temperature and the examination of mode dynamics within the tokamak. While other systems have been built for poloidal views over similar temperature ranges, this is the first multi-energy tangential-view system designed to work in a temperature range below 200 eV in a tokamak. To facilitate these measurements, a filter wheel comprising five distinct groups of dual-filters has been developed and implemented. By employing a combination of 0.1 μm aluminum and 0.2 μm titanium filters, the system allows estimation of electron temperature profiles through reconstruction of the emission profile using the standard “double-foil” technique. The influence of impurities and filter oxide layers on measurement outcomes is examined. Results reveal that, while the absolute electron temperature values may exhibit some deviations, key characteristics like the electron temperature profile shape and inversion radius during sawtooth events remain consistent. This consistency confirms the system’s suitability for core plasma studies. This system has proven effective in detecting and analyzing internal magnetohydrodynamic phenomena, such as sawteeth.

Instruments & Instrumentation↗