Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Task Force”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

WE-B-207-02: CT Lung Cancer Screening and the Medical Physicist: A Dosimetry Summary of CT Participants in the National Lung Cancer Screening Trial (NLST)

The US National Lung Screening Trial (NLST) was a multi-center randomized, controlled trial comparing a low-dose CT (LDCT) to posterior-anterior (PA) chest x-ray (CXR) in screening older, current and former heavy smokers for early detection of lung cancer. Recruitment was launched in September 2002 and ended in April 2004 when 53,454 participants had been randomized at 33 screening sites in equal proportions. Funded by the National Cancer Institute this trial demonstrated that LDCT screening reduced lung cancer mortality. The US Preventive Services Task Force (USPSTF) cited NLST findings and conclusions in its deliberations and analysis of lung cancer screening. Under the 2010 Patient Protection and Affordable Care Act, the USPSTF favorable recommendation regarding lung cancer CT screening assisted in obtaining third-party payers coverage for screening. The objective of this session is to provide an introduction to the NLST and the trial findings, in addition to a comprehensive review of the dosimetry investigations and assessments completed using individual NLST participant CT and CXR examinations. Session presentations will review and discuss the findings of two independent assessments, a CXR assessment and the findings of a CT investigation calculating individual organ dosimetry values. The CXR assessment reviewed a total of 73,733 chest x-ray exams that were performed on 92 chest imaging systems of which 66,157 participant examinations were used. The CT organ dosimetry investigation collected scan parameters from 23,773 CT examinations; a subset of the 75,133 CT examinations performed using 97 multi-detector CT scanners. Organ dose conversion coefficients were calculated using a Monte Carlo code. An experimentally-validated CT scanner simulation was coupled with 193 adult hybrid computational phantoms representing the height and weight of the current U.S. population. The dose to selected organs was calculated using the organ dose library and the abstracted scan parameters. This session will review the results and summarize the individualized doses to major organs and the mean effective dose and CTDIvol estimate for 66,157 PA chest and 23,773 CT examinations respectively, using size-dependent computational phantoms coupled with Monte Carlo calculations. Learning Objectives: Review and summarize relevant NLST findings and conclusions. Understand the scope and scale of the NLST specific to participant dosimetry. Provide a comprehensive review of NLST participant dosimetry assessments. Summarize the results of an investigation providing individualized organ dose estimates for NLST participant cohorts.

60 APPLIED LIFE SCIENCES↗

WE-D-207-00: CT Lung Cancer Screening and the Medical Physicist: Moving Forward

In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancer Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in implementing Lung Cancer Screening protocols for CT, including utilizing resources such as the AAPM Protocols and the ACR Designated Lung Screening Center program. UCLA Department of Radiology has an Institutional research agreement with Siemens Healthcare; Dr. McNitt-Gray has been a recipient of Research Support from Siemens Healthcare in the past. Dr. Aberle has been a Member of Advisory Boards for the LUNGevity Foundation (2011-present) and Siemens Medical Solutions. (2013)

60 APPLIED LIFE SCIENCES↗

WE-D-207-01: Background and Clinical Implementation of a Screening Program

In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancer Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in implementing Lung Cancer Screening protocols for CT, including utilizing resources such as the AAPM Protocols and the ACR Designated Lung Screening Center program. UCLA Department of Radiology has an Institutional research agreement with Siemens Healthcare; Dr. McNitt-Gray has been a recipient of Research Support from Siemens Healthcare in the past. Dr. Aberle has been a Member of Advisory Boards for the LUNGevity Foundation (2011-present) and Siemens Medical Solutions. (2013)

60 APPLIED LIFE SCIENCES↗

WE-D-207-02: Capturing Data Elements and the Role of Imaging Informatics

In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancer Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in implementing Lung Cancer Screening protocols for CT, including utilizing resources such as the AAPM Protocols and the ACR Designated Lung Screening Center program. UCLA Department of Radiology has an Institutional research agreement with Siemens Healthcare; Dr. McNitt-Gray has been a recipient of Research Support from Siemens Healthcare in the past. Dr. Aberle has been a Member of Advisory Boards for the LUNGevity Foundation (2011-present) and Siemens Medical Solutions. (2013)

60 APPLIED LIFE SCIENCES↗

WE-D-207-03: CT Protocols for Screening and the ACR Designated Lung Screening Program

In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancer Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in implementing Lung Cancer Screening protocols for CT, including utilizing resources such as the AAPM Protocols and the ACR Designated Lung Screening Center program. UCLA Department of Radiology has an Institutional research agreement with Siemens Healthcare; Dr. McNitt-Gray has been a recipient of Research Support from Siemens Healthcare in the past. Dr. Aberle has been a Member of Advisory Boards for the LUNGevity Foundation (2011-present) and Siemens Medical Solutions. (2013)

60 APPLIED LIFE SCIENCES↗

Lung cancer mortality among construction workers: implications for early detection

Objectives This study examined predictors of lung cancer mortality, beyond age and smoking, among construction workers employed at US Department of Energy (DOE) sites to better define eligibility for low-dose CT (LDCT) lung cancer screening. Methods Predictive models were based on 17 069 workers and 352 lung cancer deaths. Risk factors included age, gender, race/ethnicity, cigarette smoking, years of trade or DOE work, body mass index (BMI), chest X-ray results, spirometry results, respiratory symptoms, beryllium sensitisation and personal history of cancer. Competing risk Cox models were used to obtain HRs and to predict 5-year risks. Results Factors beyond age and smoking included in the final predictive model were chest X-ray changes, abnormal lung function, chronic obstructive pulmonary disease (COPD), respiratory symptoms, BMI, personal history of cancer and having worked 5 or more years at a DOE site or in construction. Risk-based LDCT eligibility demonstrated improved sensitivity, specificity and positive predictive value compared with current US Preventive Services Task Force guidelines. The risk of lung cancer death from 5 years of work in the construction industry or at a DOE site was comparable with the risk from a personal cancer history, a family history of cancer or a diagnosis of COPD. LDCT eligibility criteria used for DOE construction workers, which includes factors beyond age and smoking, identified 86% of participants who eventually would die from lung cancer compared with 51% based on age and smoking alone. Conclusions Results support inclusion of risk from occupational exposures and non-malignant respiratory clinical findings in LDCT clinical guidelines.

Public, Environmental & Occupational Health↗

Comparative study of quarkonium transport in hot QCD matter

This document summarizes the efforts of the EMMI Rapid Reaction Task Force on “Suppression and (re)generation of quarkonium in heavy-ion collisions at the LHC”, centered around their 2019 and 2022 meetings. It provides a review of existing experimental results and theoretical approaches, including lattice QCD calculations and semiclassical and quantum approaches for the dynamical evolution of quarkonia in the quark-gluon plasma as probed in high-energy heavy-ion collisions. The key ingredients of the transport models are itemized to facilitate comparisons of calculated quantities such as reaction rates, binding energies, and nuclear modification factors. A diagnostic assessment of the various results is attempted and coupled with an outlook for the future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Few is different: deciphering many-body dynamics in mesoscopic quantum gases

Emergent macroscopic descriptions of matter, such as hydrodynamics, are central to our description of complex physical systems across a wide spectrum of energy scales. The conventional understanding of these many-body phenomena has recently been shaken by a number of experimental findings. Collective behavior of matter has been observed in mesoscopic systems, such as high-energy hadron–hadron collisions, or ultracold gases with only a few strongly interacting fermions. In such systems, the separation of scales between macroscopic and microscopic dynamics (at the heart of any effective theory) is inapplicable. To address the conceptual challenges that arise from these observations and explore the universality of emergent descriptions of matter, the EMMI Rapid Reaction Task Force was assembled. This document summarizes the RRTF discussions on recent theoretical and experimental advances in this rapidly developing field. Leveraging technological breakthroughs in the control of quantum systems, we can now quantitatively explore what it means for a system to exhibit behavior beyond the sum of its individual parts. In particular, the report highlights how the (in)applicability of hydrodynamics and other effective theories can be probed across three principal frontiers: the size frontier, the equilibrium frontier, and the interaction frontier.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Federation of UML models for cyber physical use cases

This method employs the concept of federation, which is defined as the use of existing models that represent aspects of a system in specific domains (such as physical and cyber security domains) and building interfaces to link all of domain models. Federation seeks to build on existing bodies of work. Some examples include the Common Information Models (CIM) maintained by the International Electrotechnical Commission Technical Committee 57 (IEC TC 57) for the electric power industry. Another relevant model is the CIM maintained by the Distributed Management Task Force (DMTF)? this CIM defines a representation of the managed elements in an Information Technology (IT) environment. The power system is an example of a cyber-physical system, where the cyber systems, consisting of computing infrastructure such as networks and devices, play a critical role in the operation of the underlying physical electricity delivery system. Measurements from remote field devices are relayed to control centers through computer networks, and the data is processed to determine suitable control actions. Control decisions are then relayed back to field devices. It has been observed that threat actors may be able to successfully compromise this cyber layer in order to impact power system operation. Therefore, future control center applications must be wary of potentially compromised measurements coming from field devices. In order to ensure the integrity of the field measurements, these applications could make use of compromise indicators from alternate sources of information such as cyber security. Thus, modern control applications may require access to data from sources that are not defined in the local information model. In such cases, software application interfaces will require integration of data objects from cross-domain data models. When incorporating or federating different domains, it is important to have subject matter experts work together, recognizing that not everyone has the same knowledge, responsibilities, focus, or skill set.

Source record↗

Process-Oriented Diagnostics: Principles, Practice, Community Development, and Common Standards

Process-oriented diagnostics (PODs) aim to provide feedback for model developers through model analysis based on physical hypotheses. However, the step from a diagnostic based on relationships among variables, even when hypothesis driven, to specific guidance for revising model formulation or parameterizations can be substantial. The POD may provide more information than a purely performance-based metric, but a gap between POD principles and providing actionable information for specific model revisions can remain. Furthermore, in coordinating diagnostics development, there is a trade-off between freedom for the developer, aiming to capture innovation, and near-term utility to the modeling center. Best practices that allow for the former, while conforming to specifications that aid the latter, are important for community diagnostics development that leads to tangible model improvements. Promising directions to close the gap between principles and practice include the interaction of PODs with perturbed physics experiments and with more quantitative process models as well as the inclusion of personnel from modeling centers in diagnostics development groups for immediate feedback during climate model revisions. Examples are provided, along with best-practice recommendations, based on practical experience from the NOAA Model Diagnostics Task Force (MDTF). Common standards for metrics and diagnostics that have arisen from a collaboration between the MDTF and the Department of Energy’s Coordinated Model Evaluation Capability are advocated as a means of uniting community diagnostics efforts.

58 GEOSCIENCES↗

Convective Transition Statistics over Tropical Oceans for Climate Model Diagnostics: GCM Evaluation

To assess deep convective parameterizations in a variety of GCMs and examine the fast-time-scale convective transition, a set of statistics characterizing the pickup of precipitation as a function of column water vapor (CWV), PDFs and joint PDFs of CWV and precipitation, and the dependence of the moisture–precipitation relation on tropospheric temperature is evaluated using the hourly output of two versions of the GFDL Atmospheric Model, version 4 (AM4), NCAR CAM5 and superparameterized CAM (SPCAM). The 6-hourly output from the MJO Task Force (MJOTF)/GEWEX Atmospheric System Study (GASS) project is also analyzed. Contrasting statistics produced from individual models that primarily differ in representations of moist convection suggest that convective transition statistics can substantially distinguish differences in convective representation and its interaction with the large-scale flow, while models that differ only in spatial–temporal resolution, microphysics, or ocean–atmosphere coupling result in similar statistics. Most of the models simulate some version of the observed sharp increase in precipitation as CWV exceeds a critical value, as well as that convective onset occurs at higher CWV but at lower column RH as temperature increases. While some models quantitatively capture these observed features and associated probability distributions, considerable intermodel spread and departures from observations in various aspects of the precipitation–CWV relationship are noted. For instance, in many of the models, the transition from the low-CWV, nonprecipitating regime to the moist regime for CWV around and above critical is less abrupt than in observations. Additionally, some models overproduce drizzle at low CWV, and some require CWV higher than observed for strong precipitation. For many of the models, it is particularly challenging to simulate the probability distributions of CWV at high temperature.

54 ENVIRONMENTAL SCIENCES↗

Realization, Timeline, Challenges and Ultimate Limits of Future Colliders

We present a summary of the Snowmass’21 Accelerator Frontier discussions on the future collider facilities for HEP and possible implementation scenarios and challenges. The main findings of the Implementation Task Force on the required R&D duration and construction cost will be discussed. We also take a look into the possible limits of ultimate colliders in terms of energy, luminosity, size, cost, power, and timeline.

43 PARTICLE ACCELERATORS↗

Unraveling Crop Residue Harvest Effects on Soil Organic Carbon

Crop residues protect soil resources, sustain soil organic carbon (SOC), cycle nutrients, support microbial communities, and provide bioenergy feedstock. Herein we (i) summarize the origin of the “Crop Residues for Advanced Biofuels: Effects on Soil Carbon” workshop; (ii) review the workshop structure; and (iii) present consensus points, unanswered questions, and outcomes of the workshop. Initiated by a farmer/ethanol investor’s letter to the American Society of Agronomy (ASA) President, an ASA Working Group (WG) was established to make a recommendation to the ASA Board on how to respond. The WG concluded a Tri-Society sponsored workshop involving farmers, ethanol production and marketing groups, agronomists, crop scientists, soil scientists, engineers, non-governmental organizations, life cycle analysis (LCA) experts, and regulatory personnel was needed to address the complex question that had been posed and to ensure all viewpoints were fully represented. The WG was expanded to an ASA Task Force who organized the workshop in Sacramento, CA. Eighty workshop attendees identified four consensus areas (crop residue management [CRM]; severity of soil erosion; tillage, CRM and erosion linkages; and the importance of simulation [LCA] models) and four unresolved themes (carbon sequestration, CRM effects on SOC stocks, changing climate effects, and the need to focus on ecosystem services rather than single endpoints). The workshop resulted in three direct outcomes: (i) development of a stakeholder funded SOC database, (ii) LCA and SOC model improvements, and (iii) development of this special section in Agronomy Journal. Dale and Ong (2014) concluded that large scale, renewable energy systems are no longer just a “good idea”; but essential, and during the next few decades society must develop systems capable of producing clean energy at the multi-terawatt scale. Crop residues such as corn (Zea mays L.) stover, and other cellulosic materials were identified as potential feedstocks to meet this demand and have been rigorously evaluated for the past decade (e.g., Perlack et al., 2005; U.S. Department of Energy, 2011 and 2016). However, it is also well established that crop residues have important ecosystem service and productivity functions (Larson, 1979; Johnson, 2018; Ibrahim et al., 2018).

54 ENVIRONMENTAL SCIENCES↗

Demonstration Report: Handheld UXO Discriminator, SERDP No. MR-1667

In 2003, the Defense Science Board observed: 'The problem is that instruments that can detect the buried UXOs also detect numerous scrap metal objects and other artifacts, which leads to an enormous amount of expensive digging. Typically 100 holes may be dug before a real UXO is unearthed! The Task Force assessment is that much of this wasteful digging can be eliminated by the use of more advanced technology instruments that exploit modern digital processing and advanced multi-mode sensors to achieve an improved level of discrimination of scrap from UXOs.' In keeping with these remarks and with prior funding (UX-1225, MM-0437, and MM-0838), the LBNL group has successfully designed and built the cart-mounted Berkeley UXO Discriminator (BUD) and demonstrated its performance at various test sites (cf. Gasperikova et al., 2007, 2008, and 2009). Because hand-held systems have the advantage of being lightweight, compact, portable, and deployable under most site conditions, they are particularly useful in areas of dense vegetation or challenging terrain. In heavily wooded areas or areas with steep or uneven terrain, hand-held sensors may be the only suitable device for UXO detection and discrimination because it can be carried through spaces that the operator could walk through or at least approach. Furthermore, it is desirable to find and characterize a metallic object without the need to accurately locate the sensors at multiple positions around the target. The ideal system would thus locate and characterize the target from a single position of the sensor and indicate to the operator where to flag the target for subsequent study. Based on these considerations, we designed and built a sensor package in a shape of a 14-in (0.35 m) cube. This hand-held prototype incorporates the key features of the cart-mounted system - (a) three orthogonal transmitters and ten pairs of receivers, and (b) difference or gradient measurements that significantly reduce the ambient and motion noise, and greatly enhance the sensitivity to the gradients of the target. The system characterizes the target from a single position. Results from a local test site were in a good agreement with theoretical performance calculations of such a device. This survey was designed to demonstrate performance of the system under realistic survey conditions at the Aberdeen Proving Ground (APG) in Aberdeen, MD. The survey was preformed in an area with known items ('Calibration Grid'), and in a seeded blind test area (the 'Blind Test Grid'). The ground truth for the surveys conducted on the Blind Test Grid was withheld from the testers. Only the graded test scores based on target detection and target classification were provided. For more information, see http://aec.army.mil/usaec/technology/uxo01c03.html.

54 ENVIRONMENTAL SCIENCES↗

Emerging technologies and approaches to minimize discharges into Lake Michigan Phase 2, Module 3 report.

Purdue University Calumet (Purdue) and Argonne National Laboratory (Argonne) have conducted an independent study to identify deployable technologies that could help the BP Whiting Refinery, and other petroleum refineries, meet future wastewater discharge limits. This study has been funded by BP. Each organization tested a subset of the target technologies and retains sole responsibility for its respective test design and implementation, quality assurance and control, test results obtained from each of the technologies, and corresponding conclusions and recommendations. This project was divided in two phases and modules. This report summarizes the work conducted by Argonne in Phase II Module 3 (Bench Scale Testing). Other Modules are discussed elsewhere (Emerging Technologies and Approaches to Minimize Discharges into Lake Michigan, Phase 2, Modules 1-3 Report, April 2011, prepared for BP Americas by the Argonne - Purdue Task Force). The goal of this project was to identify and assess available and emerging wastewater treatment technologies for removing mercury and vanadium from the Whiting Refinery wastewater and to conduct bench-scale tests to provide comparable, transparent, and uniform results across the broad range of technologies tested. After the bench-scale testing phase, a previously developed decision matrix was refined and applied by Argonne to process and review test data to estimate and compare the preliminary performance, engineering configuration, preliminary cost, energy usage, and waste generation of technologies that were shown to be able to remove Hg and/or V to below the target limit at the bench scale. The data were used as the basis to identify the best candidates for further testing at the bench or pilot scale on a slip stream of effluent to lake (ETL) or clarifier effluent (CE) at the Whiting Refinery to determine whether future limits could be met and to generate other pertinent data for scale-up and sustainability evaluation. As a result of this technology assessment, Argonne identified several technologies that, at the bench-scale, could achieve the targeted performance for the removal of mercury and vanadium. A subset of those technologies were recommended for further testing either at the bench scale or at the pilot scale to determine whether future discharge limits could be met at the pilot-scale. The objectives of this project module are to: (1) Test at the bench-scale a subset of the technologies previously identified in Module 1 for the removal of target heavy metals down to 1.3 ppt Hg and 280 ppb V; (2) Review and process bench-scale test results on the basis of the end-point performance measures matrix to determine preliminary comparative performance, cost-effectiveness, and potential engineering configuration of tested technologies; (3) Assess the technological feasibility and readiness of the identified technologies for implementation at the Whiting Refinery; and (4) Select technically and economically feasible mercury- and vanadium-removal technologies and vendors to be recommended for pilot-scale testing at the Whiting Refinery.

02 PETROLEUM↗

Green Building Policy Options for New Orleans

This document is adapted from a memo and report delivered to the City Council of New Orleans, the office of the Mayor of New Orleans, the Chairperson of the Citizen Stakeholders Group (New Orleans Energy Task Force) and the U.S. Department of Energy (DOE) Project Officer in 2008. The report outlines ideas for and potential impacts of various green building policies in New Orleans in the yearsfollowing Hurricane Katrina.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Government Program Briefing: Smart Metering

This document is adapted and updated from a memo delivered to the City Council of New Orleans, the office of the Mayor of New Orleans, the Chairperson of the Citizen Stakeholders Group (New Orleans Energy Task Force) and the U.S. Department of Energy (DOE) Project Officer in March 2008. This briefing piece provides an overview of the benefits, costs, and challenges of smart metering.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Potential Next Steps for the New Orleans City Council Energy Efficiency Resolution

This document is adapted from an actual February 2008 deliverable memo and report delivered by the National Renewable Energy Laboratory (NREL) to the City Council of New Orleans, the office of the Mayor of New Orleans, the Chairperson of the Citizen Stakeholders Group (New Orleans Energy Task Force) and the Department of Energy Project Officer in February of 2008.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗