Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tank testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Optimal Control of an Oscillating Surge Wave Energy Converter

During this project, we experimentally investigated the hydrodynamics and performance of a laboratory-scale oscillating surge wave energy converter (OSWEC).We looked at how flap buoyancy and driveline losses (primarily in the form of stiction) affected the dynamics and performance of the device. In addition, we assessed the influence of flap profile (rounded vs. square edges) on OSWEC hydrodynamics. Through this, we were able to develop a deeper understanding of OSWEC performance and provide guidance on strategies to counteract artifacts that may be present in laboratory models, but are absent in field-scale devices. To do this, we tested a laboratory-scale OSWEC in the Sea Wave Environmental Lab (SWEL) wave tank at the National Renewable Energy Laboratory (NREL). We ran several types of experiments to investigate the hydrodynamics and performance of the device. Overall, we achieved the overall goal of experimentally investigating the hydrodynamics and performance of this device. We discovered important and unexpected trends in performance, and collected time-resolved data to help us further investigate the underlying hydrodynamics responsible for these trends. In addition, we are currently using the time-resolved data from these experiments to build data-driven models of the dynamics, which can in turn be used to inform data-driven model predictive control of this device and address this objective in the future.

16 TIDAL AND WAVE POWER↗

Tests of a High Temperature Sample Conditioner for the Waste Treatment Plant LV-S2, LV S3, HV S3A and HV-S3B Exhaust Systems

Tests were performed to evaluate a sample conditioning unit for stack monitoring at Hanford Tank Waste Treatment and Immobilization Plant (WTP) exhaust stacks with elevated air temperatures. The LV-S2, LV-S3, HV-S3A and HV-S3B exhaust stacks are expected to have elevated air temperature and dew point. At these emission points, exhaust temperatures are too high to deliver the air sample directly to the required stack monitoring equipment. As a result, a sample conditioning system is considered to cool and dry the air prior to its delivery to the stack monitoring system. The method proposed for the sample conditioning is a dilution system that will introduce cooler, dry air to the air sample stream. This method of sample conditioning is meant to reduce the sample temperature while avoiding condensation of moisture in the sample stream. An additional constraint is that the ANSI/HPS N13.1-1999 standard states that at least 50% of the 10 µm aerodynamic diameter (AD) particles present in the stack free stream must be delivered to the sample collector. In other words, depositional loss of particles should be limited to 50% in the sampling, transport, and conditioning systems. Based on estimates of particle penetration through the LV-S3 sampling system, the diluter should perform with about 80% penetration or better to ensure that the total sampling system passes the 50% or greater penetration criterion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the January 2023 Semiannual Tank 50 Salt Solution Sample

In this Technical Report, the chemical and radionuclide contaminant results from the January 2023 Semiannual sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Mission Completion (SRMC) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility (SPF), where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) LIMITS and TARGETS that were established at the time the Tank 50 sample was obtained.1 The chemical and radionuclide contaminant results from the characterization of the January 2023 semiannual sampling of Tank 50 were requested by SRMC personnel via a Task Technical Request (TTR)2 and details of the testing are presented in the Savannah River National Laboratory (SRNL) Task Technical and Quality Assurance Plan (TTQAP).3 This Technical Report is part of Deliverable 2 relating to Task 1 from the SRMC request.2 Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals per Task 2 from the SRMC request will be obtained semiannually for the January 2023 and July 2023 Tank 50 samples.

Crawford, Charles L.↗

Performance Evaluation of Low-Cost Condensers Immersed in the Water Tank of a Heat Pump Water Heater

This paper reports the effect of low-cost immersed condensers on the performance of a heat pump water heater (HPWH) that does not require a water-circulating pump. The proposed design is based on the immersion of an L-style condenser coil through an opening in the top of the water tank. The novel design aims to eliminate the need for the water-circulating pumps, thereby substantially improving efficiency and reducing costs and maintenance of the HPWH system. Comprehensive computational fluid dynamics (CFD) simulations and experimental tests were performed, and the results showed that the CFD simulations were close to the experimental data. Further results confirm that the L-style condenser can introduce buoyancy-driven flow and eliminate temperature stratification in the studied HPWH water tank, thereby improving the heat transfer coefficient and coefficient of performance of the HPWH. The testing results further showed that the L-style condenser enabled more than 53% higher coefficient of performance and 400% higher heat transfer coefficient compared with the straight vertical condenser, and achieved much faster water heating. Furthermore, the effects of immersed condensers with different circuits on the HPWH performance were evaluated and compared. All results indicate that the current energy-saving and inexpensive HPWH technology is technically valid, and the benefits of performance improvement and low cost are attractive in future HPWH design.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Vitrification of Hanford Tank 241-AP-107 with Recycled Condensate

During the vitrification of nuclear waste at the Hanford Waste Treatment and Immobilization Plant (WTP) – the primary mission of the U.S. Department of Energy Office of River Protection – the offgas condensate generated from the waste-to-glass conversion is currently planned to be concentrated by evaporation in the Effluent Management Facility (EMF). This concentrated condensate can then be recycled back to the incoming waste and vitrified. To test the recycle process, a test apparatus was designed to mimic the EMF evaporator and used to concentrate a volume of condensate that had been previously produced during the vitrification of Hanford tank 241-AP-107 (referred to herein as AP-107) waste in a continuous laboratory-scale melter (CLSM). The test apparatus successfully concentrated the AP-107 condensate by a factor of 10 while retaining over 90 % of the technetium-99 ( 99 Tc), Cs, and I inventory. A second portion of AP-107 waste was retrieved by Washington River Protection Solutions, LLC, given to Pacific Northwest National Laboratory, and combined with the AP-107 condensate concentrate after undergoing solids filtration and cesium removal by ion exchange. This combination served to approximate the recycling action to be performed at the WTP. After the addition of glass-forming chemicals (GFCs), the combined AP-107 waste and AP-107 condensate concentrate were processed in the CLSM to produce a glass, called AP-107-1R, that was designed to satisfy the WTP baseline requirements (Kim et al. 2012). During the 8.87 hours of processing, 7.27 kg of AP-107-1R glass were produced for an average glass production rate of 1739 kg m 2 d -1 . Compared to the previous run in the CLSM without recycled condensate, the run with the recycle had a greater average glass production rate, but the rate was within the potential range of variability when processing melter feeds with similar composition in the CLSM. The glass produced from the AP-107 recycle run in the CLSM was within 10 % of the target AP-107-1R glass composition with respect to the primary glass components. Analysis of the minor component impurities revealed that their content in the glass product had approached their nominal target after 2 turnovers of the glass inventory in the CLSM while the activity of the minor radionuclides was retained in the glass product. The 99 Tc and total cesium content in the combined AP-107 waste and recycled condensate were maintained at concentrations expected to be experienced at the WTP. During processing in the CLSM, at discrete sampling time periods, the target 99 Tc/Cs mass ratio in the glass formulation varied from 0.9 to 62.9. Across this range, the Cs retention in the glass ranged from 53 to 60 %, while the retention from the entire runtime totaled 68 %, values which align with Cs retention in other scaled melter systems while processing LAW melter feeds at 99 Tc/Cs mass ratios ranging from 1 to 100. The 99 Tc retention in the glass ranged from 22 to 32 %, primarily due to the cold-cap coverage on the glass melt surface, the area covered by reacting melter feed, varying from ~80 % to ~95 % during processing, demonstrating greater volatility of 99 Tc from the glass while more surface was exposed, as expected based on previous 99 Tc volatility studies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nitrate and Nitrite at Hanford – From Tanks to Natural Attenuation

Washington River Protection Solutions, LLC (WRPS) contracted Pacific Northwest National Laboratory (PNNL) in support of their maturation testing and analysis to develop and deploy an ambient temperature solidification/stabilization process for low-activity waste (LAW) (referred to as “grout” in this report). The intent of this effort is to support a sample-and-send regulatory and processing strategy in the Hanford 200 West Area, specifically considering grout waste forms disposal at Hanford in the Integrated Disposal Facility (IDF). Currently the disposal of grouted LAW is not an option because the IDF is not permitted to receive this waste form. The material presented in this report is intended to help inform the U.S. Department of Energy (DOE), the site operating contractors, regulatory agencies, and stakeholders of the future implications of IDF disposal of a grouted LAW waste form, specifically for the behavior of nitrate (NO 3 - ) and nitrite (NO 2 - ) at the Hanford. The only calculation of nitrate release from a hypothetical grouted LAW inventory in the IDF showed that the overall release was slightly above the compliance limit of 45 mg/L nitrate and 3.32 mg/L nitrate after 1000 years (Asmussen et al. 2019). As such, uncertainty around the impact of nitrate and nitrite release from the IDF was identified in the recent National Academies of Sciences study of Hanford supplemental LAW by both the national laboratory team and Hanford stakeholders (Bates et al. 2023). However, these calculations (and others for the IDF involving secondary waste grout) may be conservative as no nitrate and nitrite retention in the grout waste form was assumed, nor any attenuation in the subsurface. There is evidence from the literature of processes that can attenuate nitrate migration both in the waste form and in the Hanford subsurface. If found to be technically defensible and likely to occur in the IDF and associated subsurface, then these processes should be included in modeling of the IDF to represent the behavior of nitrate and nitrite more accurately. Doing so would remove unnecessary conservatism in the modeling projections and reduce the uncertainty in assessments of facility compliance of a grouted LAW waste form in the IDF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Organic Evaporation, Oxidation, and Hydrolysis Testing in Support of Hanford Sample-and-Send

The Hanford site has approximately 54 to 56 million gallons of radioactive mixed waste stored in 156 unretrieved underground storage tanks. The Hanford Waste Treatment and Immobilization Plant (WTP) is being built to treat and immobilize the tank waste. The baseline method for immobilization of Low Activity Waste (LAW) through the WTP is vitrification, but additional immobilization capacity is needed to supplement the initial LAW melters. An alternative cementitious waste form is being investigated for that future immobilization method. However, one impediment to a cementitious waste form is the presence of Land Disposal Restricted (LDR) organic chemicals in tank waste, which are regulated on a concentration based standard in the final waste form. Hence, if the quantity of organics in LAW is high enough, they must be destroyed or removed to make a waste form compatible with disposal in a mixed low level waste landfill. This work evaluates potential avenues for treatment of LDR organics to eliminate the impediment and permit possible use of a cementitious waste form. Vacuum evaporation testing to remove LDR organics consisted of preparing a non-radioactive LAW simulant, spiking that simulant with organic chemicals, and evaporating the mixture via differential distillation. The apparatus was a laboratory-scale vacuum evaporator operated at 60 ±5 torr absolute (vacuum evaporation). The LAW simulant represented the liquid expected to be retrieved from the Hanford tank farms at approximately 4.0 M [Na+] total sodium ion concentration. The concentration of the organic chemicals added was significantly higher than typically found in the tank waste samples since the higher levels were necessary to assist in analytical measurement and tracking of the spiked species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the September Bimonthly Calendar Year 2022 Tank 50 Salt Solution Sample

In this Technical Report, the chemical and radionuclide contaminant results from the 2022 September bimonthly sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Mission Completion (SRMC) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility (SPF), where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) LIMITS and TARGETS that were established at the time the Tank 50 sample was obtained. The chemical and radionuclide contaminant results from the characterization of the 2022 September bimonthly sampling of Tank 50 were requested by SRMC personnel via a Task Technical Request (TTR). Details of the testing are presented in the Savannah River National Laboratory (SRNL) Task Technical and Quality Assurance Plan (TTQAP). This Technical Report is the TTR deliverable relating Salt Solution Analysis from the SRMC request. The following facts pertaining to the WAC are drawn from the analytical results, including analytical uncertainty, provided in this report. 1) WAC LIMITS and TARGETS were met for all analyzed chemical and radioactive contaminants for which the detection limits are below the WAC LIMITS and TARGETS; 2) Measured average concentrations of nitrate, nitrite and total mercury are approximately 24%, 9% and 12% of the WAC LIMITS, respectively; 3) Measured average concentrations of Tc-99 and I-129 are approximately 19% and 20% of the WAC LIMITS, respectively; 4) All other radionuclide average concentrations are at 4% or less of the WAC LIMITS and TARGETS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recent Cryogenic Carbon Capture™ Field Test Results

Sustainable Energy Solutions (SES) has been developing Cryogenic Carbon Capture™ (CCC) since 2008. In that time, two processes have been developed, the External Cooling Loop and Compressed Flue Gas CCC processes (CCC-ECL and CCC-CFG, respectively). The CCC-ECL process cools the flue gas with an external refrigerant loop. This process currently captures up to 1 tonne of CO2 per day (TPD). SES has tested CCC-ECL on real flue gas slip streams from subbituminous coal, bituminous coal, biomass, natural gas, shredded tires, and municipal waste fuels at field sites that include utility power stations, heating plants, cement kilns, and pilot-scale research reactors. The CO2 concentrations from these tests ranged from 5 to 22% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2 and PMxx at 95+%. NO was also captured at a modest rate. The CCC-CFG process has been scaled up to a 0.25 ton per day system. This system has been tested on real flue gas streams including subbituminous coal, bituminous coal, and natural gas at field sites that include utility power stations, heating plants, and pilot-scale research reactors. CO2 concentrations for these tests ranged from 5 to 15% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2, and PMxx at 95+%. NO was also captured at 90+%. Hg capture was also verified and the resulting effluent from CCC-CFG was below a 1ppt concentration. This paper will focus on discussion of the capabilities of CCC generally, the results of CCC-ECL field testing, and future steps surrounding the development of this technology. Test results that will be presented have been collected during 9 months of testing at a commercial power plant under funding from the US Department of Energy (DOE) and the host utility. Testing of one of the systems at a commercial cement plant in the United States will also be discussed. During this testing, the system captured CO2 from the cement plant and stored the CO2 in pressurized tanks. These tanks were provided to a partner company that later used the CO2 in a CO2 utilization demonstration. The CO2 was utilized to cure concrete manufactured using cement from the same plant where the CO2 was captured. This integrated capture and utilization demonstration was the first time that the cement industry has shown in the field that it can sequester its CO2 emissions in its main product stream. This represents a potential game changing solution for industrial CO2 emissions. Operational data and host-site feedback indicate that the CCC process is ideally suited for deployment into a variety of commercial environments. A few areas of de-risking remain to make sure the technology can meet very strict industrial reliability standards. These areas of de-risking are identified and discussed. The product CO2 is shown to meet specification for many uses including industrial and merchant applications. The technology is nearing readiness for deployment at commercial scale and several initial target markets have been identified.

20 FOSSIL-FUELED POWER PLANTS↗

Vitrification Testing of HLW with High Phosphate

Projections of the number of high level waste (HLW) canisters to be produced in the Hanford Tank Waste Treatment and Immobilization Plant (WTP) (e.g., [1]) are based upon the inventory of the tank wastes, the anticipated performance of the sludge treatment processes, and current understanding of the capability of the borosilicate glass waste form. The WTP HLW melter design, unlike earlier Department of Energy (DOE) melter designs, incorporates a glass bubbler system. The bubblers create active glass pool mixing and thereby improve heat and mass transfer and glass melting rate. The WTP HLW melters each have a glass surface area of 3.75 m 2 and depth of ~1.1 m. The two melters in the HLW facility together are designed to produce up to 7.5 MT of glass per day at 100% availability. Further increases in HLW waste processing rates can potentially be achieved by optimization of the feed and glass formulations, increasing the melter operating temperature above 1150⁰C, and by increasing the waste loading in the glass product. Increasing the waste loading also has the added benefit of decreasing the number of canisters for storage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pilot-Scale Testing of an Integrated Circuit for the Extraction of Rare Earth Minerals and Elements from Coal and Coal Byproducts Using Advanced Separation Technologies

The primary objective of this project was to develop and demonstrate an integrated pilot-scale circuitry for recovering high-value rare earth elements (REEs) from coal and coal byproducts. The target performance was to produce a mixed REE product with content of at least two percent by weight on a dry mass basis in a cost-effective and environmentally benign manner. During the first nine months of the project period (Phase 2 Budget Period 2), pilot plant construction was completed including all field site startup activities such as permitting, engineering design, procurement/bidding, unit fabrication, site construction, equipment installation, module assembly, safety training, and circuit shakedown. During the remaining 21 months of project period (Phase 2 Budget Period 3), detailed field-testing activities were performed including feedstock sample collection and preparation, exploratory testing, circuit modification, detailed parametric study, and performance optimization. A detailed techno-economic analysis was performed based on the pilot plant testing findings which provided various scenarios for REE production. The project successfully accomplished the proposed target performance by producing mixed rare earth oxide (REO) with greater than 90% purity by weight in a continuous pilot scale operation from two distinctly different coarse refuse materials (i.e., West Kentucky No. 13 and Fire Clay coal seams), and at least three secondary sources (i.e., heap leach process and naturally formed acid mine drainage system). Project partners included the University of Kentucky, Virginia Tech, West Virginia University, Alliance Coal, Blackhawk Mining, Mineral Refining Company, and Mineral Separation Technologies. The pilot scale test facility was constructed at a former mining complex owned by Alliance Natural Resource Partners (Alliance Coal). The site was rehabilitated to accommodate the equipment installation, construction and fabrication, electrical power requirement, water line management and containment. The process units constructed and installed included X-ray sorting unit, crushing and grinding unit, physical separation unit, acid leaching unit, solvent extraction unit, and wastewater management unit. A rare earth mineral concentration unit was constructed as a standalone unit for flexible operation. A detailed environmental assessment and control plan was carried out to identify and quantify any potential impacts of the pilot-scale processing circuitry on the human and eco-system health and well-being. Corresponding mitigation strategies and control measures were provided. A conceptual flowsheet was developed to effectively remove thorium and uranium from high purity rare earth oxide mix or any potential radionuclide enriched stream. The two distinct feedstock materials were secured from the Blackhawk Mining Complex in eastern Kentucky where the Fire Clay (Hazard No. 4) seam is processed. The West Kentucky No. 13 (Baker) coarse refuse material was collected from an active process stream at an Alliance coal preparation plant located in western Kentucky. Characterization analysis indicated that both of feed materials generated from the two sources contained >300 ppm of TREEs on a dry whole mass basis which met the requirements for a qualified feed stock. The two feedstocks were further upgraded using a dual x-ray sorter to prepare the feed material for hydrometallurgical circuit. Thermal treatment on feed material prior to leaching was found to: 1) improve the leaching recovery of REEs, 2) increase the leaching kinetics, and 3) allow the leaching reaction to occur at lower acidity. Roasting at 600°C was selected as the pre-treatment condition for both West Kentucky No. 13 and Fire Clay coarse refuse material. Over 40% of leaching recovery was achieved by roasting West Kentucky No. 13 material having a top particle size of 3 mm in the pilot scale operation using 1.2M sulfuric acid leaching at 75OC. Initial pilot scale testing involved continuous operation of the pilot plant for 94 hours. The leaching unit was operated at solid-to-liquid ratio of 1 to 10 (w/v) using 0.5M sulfuric acid solution at a temperature of 75°C. The continuous solvent extraction circuit utilized rougher and cleaner units with DEHPA and TBP as the extractants. An innovative stripping circuit was developed to accumulate the REE concentration in the stripping solution to a level above 600 ppm. A bleed stream from the recycled strip solution was treated using oxalic acid precipitation which produced a high grade rare earth oxalate. The oxalate product was roasted to remove the oxalate which produced a rare earth oxide product having a purity greater 90%. Due to high concentrations of contaminant ions in the pregnant leach solution (PLS), a modified flowsheet was developed that involved pre-concentration of the REEs using multiple stages of precipitation and redissolution. The advantage of this process was improved removal of contamination before the downstream purification process and a significant cost reduction relative to the circuit that utilized the solvent extraction process. The modified circuitry included processes involving leaching, multistage precipitation, redissolution, and oxalate precipitation followed by roasting of the oxalate product. The circuit produced a mixed REO that was 92.96% pure from the initial test. A detailed parametric test plan was carried out which involved varying key parameters including solids feed rate, acid flowrate, acid concentration, multistage precipitation pH, redissolution pH, oxalate precipitation dosage and pH. The response variables included REE recovery, contaminant recovery, REO product grade and overall chemical consumption. Test results indicated that the acid-to-solid ratio is the key parameter to leaching efficiency as performance deteriorated with an increase in solids concentration. The optimal pH determined for REE precipitation and redissolution was 6.5 and 2.5, respectively. Additional tests were conducted to further improve the flowsheet. Recirculating a portion of the PLS to the feed of the leach tanks improved the leaching performance by lowering the pH of the leaching system and reducing the contamination recovery by shortening the residence time. Moreover, the removal of Al prior to REE precipitation significantly reduced the oxalic acid consumption in the oxalate precipitation circuit. The modified circuit produced over 90% grade REO by weight from both West Kentucky No. 13 and Fire Clay coarse refuse material in pilot scale continuous test programs. A case analysis model was developed to project the REE and major contaminants concentration in each PLS stream based on the leaching condition, pH cut point, and oxalic acid dosage. A correlation was established using empirical and semi-empirical models. Using the models, chemical consumption required for each stage was predicted based on the projected performance of the hydrometallurgy circuit. After identifying the optimum conditions, validation tests were carried out for the treatment of both West Kentucky No. 13 and Fire Clay coarse refuse materials in the pilot plant. The actual circuit performance and chemical consumptions were very close to the model predictions. Other than the two coarse refuse sources, several secondary feedstocks were also tested in the pilot plant facility. A “heap leach” system was constructed using the coarse refuse material generated from cleaning the West Kentucky No. 13 seam coal. Using the two stage SX rougher and cleaner circuit, a concentrate with a grade >90% REO was produced while recovering >97% of the REEs from the heap leach PLS. Naturally generated acid mine drainage (AMD) from West Kentucky No.13 mine was processed using the multistage precipitation circuit in the pilot plant in a test conducted for a period of 32 hours. The final grade of the mix RE oxide produced from the AMD was 90.84% with an overall circuit recovery of 64%. The primary source of REE was the selective precipitation steps involving iron and aluminum rejection. The hydrophobic-hydrophilic separation (HHS) process was proven to effectively recover coal from fine waste materials. For REM recovery, the HHS process was able to produce concentrates at grades of approximately 1.8% REE on an ash basis; however, recovery values were typically low, <10%, under the optimal conditions determined in the laboratory-scale testing. Staged testing of the pilot-scale HHS process for coal recovery and semi-continuous laboratory testing for REM testing showed that a total concentration ratio of more than 15x was observed for the REM recovery process. A circuit simulation package was developed for REE extraction and purification using a spreadsheet-based platform (Microsoft Excel). The REESim circuit simulation package is configured to track the mass and volume flows of components passing through a series of unit operations specified and configured by the user. The mass rates can then be utilized by the user to determine important performance indicators such as product mass yields, concentrate purity levels, element-by-element recoveries, and so forth. The techno-economic analysis showed that the roasting and leaching operations were the most expensive capital items, each contributing approximately 30% to the total capital cost. One notable contributor to the high production costs was the low REE recovery observed in the pilot scale trials. The product basket price was shown to have a strong influence on the economic viability of the scenarios, with the scandium price being the most significant influencer. Operating cost was shown to be extremely sensitive to REE recovery, REE feed grade, and leaching acid consumption. An analysis of ten different scenarios for a 500 t/h commercial operation revealed that three were economically favorable, producing internal rates of return varying from 27.7% to 33.1% and payback periods of 4 to 5 years. The project successfully developed and demonstrated a process to recover REEs from coal and coal byproducts in a pilot-plant operation which consistently produced over 90% grade REO mix from varies types of feedstocks. Commercialization analysis showed that the technology readiness level successfully achieved TRL 6 at the end of the project and demonstrated the need and the potential for scaling the process to further advance the technologies toward the goal of providing a domestic supply of REEs at a commercial scale.

01 COAL, LIGNITE, AND PEAT↗

Development of an MC&A toolbox for liquid-fueled molten salt reactors with online reprocessing (Final Report)

A critical barrier to the deployment of MSRs is the absence of a well-defined nuclear material control and accounting (MC&A) approach, a vital prerequisite to meet NRC licensing requirements as well as facilitating future international exports. Liquid-fueled MSR variants (especially those incorporating online refueling or reprocessing) present a unique set of challenges to traditional nuclear material control and accountancy. Unlike solid-fueled light-water reactors, traditional item-counting methods cannot be applied as an accountancy strategy. Rather, MC&A approaches to MSR variants (including both uranium and thorium fueled designs) are more analogous to bulk material handling facilities (e.g., enrichment and reprocessing); yet further complicating matters is the fact that fuel medium is also highly radioactive. Meanwhile, the space of MSRs covers a broad range of design parameters, including thermal and fast spectra designs; operation in actinide breeder or burner modes, choice of actinide fuel used (e.g., 235 U, 232 Th / 233 U, denatured 233 U, etc.), pool or loop-type configuration, and even different salt chemistry. Each of these design choices introduce significant challenges to MC&A approaches within MSR facilities. We propose to bridge this gap for liquid-fueled MSRs by developing a modular, component-based test framework for evaluating viable process monitoring and MC&A techniques specifically suited to liquid-fueled MSR system variants employing online refueling or reprocessing. This test platform will consist of a toolbox of independent process modules representing discrete physical units (such as the reactor core, off-gas processing, decay tanks, and actinide separation units), each with its own self-contained physics responsive to the input mass flow, along with appropriate measurement models that can be coupled to key flow points. These dynamic physical signatures thus afford the ability to test the viability and efficacy of potential accountancy techniques under the full range of reactor operating conditions. As process modules are connected via mass flows, the result is a reconfigurable, generic MSR mass flow model capable of serving as an MC&A test platform for a broad spectrum of possible MSR configurations. The resulting MSR MC&A toolbox will enable robust assessment of accountancy strategies for this unique facility type, including analysis of physical feedbacks arising both from depletion of the fuel over time as well as from potential off-normal events, including those introduced by equipment failures (e.g., a pump failure) as well as by malicious action (i.e., attempts to divert material). The proposed toolbox both addresses a critical needs area for the MPACT analysis toolkit while leveraging existing MPACT-sponsored tools, especially with respect to simulation of measurement and accountancy techniques for advanced fuel cycle facilities. Beyond enabling new analysis capabilities for MSR systems, the design of this toolbox will be to such to maximize compatibility with existing MPACT tools, such to enhance existing facility MC&A analysis capabilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

RELAP5-3D Modeling of High Temperature Test Facility (HTTF) Test PG-26

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors with prismatic fuel and reflector blocks. Several tests have been completed, and more are still planned to at the HTTF, including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This report analyses test PG-26, a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC. PG-26 has been performed at the HTTF between May 30 and June 30, 2019. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heaters. The DCC transient was initiated during the 50 th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test. Version 4.4.2ie of the RELAP5-3D computer code has been used to model the HTTF PG-26 test, and results have been compared to available high-quality measured data. The model used in this study is the quality-controlled HTTF RELAP5-3D model (HTTF base 2018-04-19 QA), originally developed by P. Bayless. The report includes RELAP5-3D results of the “base calculations” as well as some sensitivities to important uncertain model inputs, such as primary helium mass flow rate, core ceramic thermal properties, as well as heat evacuation and loop friction models. Using the base RELAP5-3D model predicts a countercurrent helium flow in the hot duct observed at the beginning of the DCC, but instead of going into a molecular diffusion mode, the model predicts the onset of natural convection. Increasing friction in the core and hot duct prevents the natural convection from happening in some of the simulations. Although some temperatures are well predicted (and even overpredicted), the general tendency is to underpredict the ceramic and helium temperatures and heat removal rates during the DCC, resulting in many of the assessment findings being in minimal or insufficient agreement with the data. It is worth noting that the described discrepancies between measured data and RELAP5-3D predictions are not RELAP5-3D code limitations. More so, they reflect limitations in boundary condition and thermal property knowledge. While the RELAP5-3D calculations of the test provide some insights into what happens during the transient, and point to missing or potentially uncertain data to which the experimenters can direct their attention, the principal conclusion is that the PG-26 test data are insufficient for a system code assessment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling of HTTF test PG-26 using RELAP5-3D and SAM

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors (HTGR) with prismatic fuel and reflector blocks [1]. Several tests have been completed at the HTTF including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This summary reports on the analysis of test PG-26 using the INL system code REALP5-3D [2] as well as the ANL system code SAM [3]. Test PG-26 is a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC [4]. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heater banks. The DCC transient was initiated during the 50th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test.

97 MATHEMATICS AND COMPUTING↗

Hanford Double Shell Waste Tank Corrosion Studies- Final Report FY2024

For fiscal year (FY) 2024, the Savannah River National Laboratory (SRNL) focused on two experimental tasks related to Hanford Double Shell Tank (DST) chemistry and integrity. The first task focused on understanding risk of corrosion due to formation of either continuous layers or discrete patches of solids on the tanks’ inner sidewalls and bottoms. The objective of this task was to determine the effect of solid deposits on the corrosion risk to the tank bottom, and whether a combination of scale, saltcake and loose solids lead to under deposit corrosion. Electrochemical testing in a single cell arrangement was employed to determine a threshold inhibitor level for the interstitial liquid in the solids, above which carbon steel was not susceptible to corrosion beneath the solids. The inhibitor levels tested were based on the previously determined probability of failure for carbon steel in a simulated waste (i.e., Pitting Factor).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sludge Batch 11 Assembly: Tank 26

Savannah River Mission Completion Nuclear Safety and Engineering Integration (SRMC-E) has requested that Savannah River National Laboratory (SRNL) perform Tank 26 characterization analyses in support of Sludge Batch 11 (SB11) assembly. This report provides important characterization of the slurry in Tank 26 prior to transfer from Tank 26 to Tank 51 that confirms the transfer is "Low Rem" and ensures the sludge concurs with the estimated transfer mass for the SB11 recipe. Two Tank 26 samples were delivered to SRNL and composited into a single sample in September 2023. The composite sample was analyzed for the following: density, weight percent solids, chemical composition, radionuclides, supernate corrosion control tests, and x-ray diffraction for burkeite, gibbsite, and boehmite. The slurry was also evaluated for sulfate washing behavior in order to provide knowledge on insoluble sulfate dissolution during Tank 51 sludge washing similar to a previous washing study performed in 2019. The Tank 26 sample results are consistent with and representative of PUREX sludge and the prior usage of Tank 26 as a feed tank for the 1F and 2F Evaporators.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sludge Batch 11 Assembly: Tank 26 (Rev.1)

Savannah River Mission Completion Nuclear Safety and Engineering Integration (SRMC-E) has requested that Savannah River National Laboratory (SRNL) perform Tank 26 characterization analyses in support of Sludge Batch 11 (SB11) assembly. This report provides important characterization of the slurry in Tank 26 prior to transfer from Tank 26 to Tank 51 that confirms the transfer is "Low Rem" and ensures the sludge concurs with the estimated transfer mass for the SB11 recipe. Two Tank 26 samples were delivered to SRNL and composited into a single sample in September 2023. The composite sample was analyzed for the following: density, weight percent solids, chemical composition, radionuclides, supernate corrosion control tests, and x-ray diffraction for burkeite, gibbsite, and boehmite. The slurry was also evaluated for sulfate washing behavior in order to provide knowledge on insoluble sulfate dissolution during Tank 51 sludge washing similar to a previous washing study performed in 2019. The Tank 26 sample results are consistent with and representative of PUREX sludge and the prior usage of Tank 26 as a feed tank for the 1F and 2F Evaporators.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Review of Tank 48H Treatment of Tetraphenylborate with Permanganate

Tank 48H contains roughly 270,000 gallons of radioactive waste material. The waste stored in this tank was to be processed in multiple stages utilizing facilities at the Savannah River Site (SRS) almost 30 years ago. The In-Tank Precipitation Process (ITP) was initiated in Tank 48H, which precipitated highly radioactive cesium-137 using sodium tetraphenylborate (NaTPB). While the process succeeded in precipitating the Cs, Sr, and other actinides, it also generated an unexpectedly large amount of benzene. The evolved benzene created a safety concern and made the waste incompatible with further downstream processing. This halted the ITP, and a new method of treatment was required to continue processing the legacy waste contained in Tank 48H. A myriad of treatment options have been proposed with multiple teams of researchers assembled to work on this highly complex issue over the last few decades. This review investigated one potentially viable treatment option, in-tank oxidation with sodium permanganate. Permanganate has been well known in literature as a strong oxidizing agent for organic compounds, as well as being utilized at the Savannah River Site (SRS) in other processes. A small number of studies have been conducted utilizing waste simulants to evaluate the use of permanganate as an oxidant for tetraphenylborate (TPB). A search of the literature and data from these studies indicates that permanganate could be a viable treatment for destruction of TPB in Tank 48H. While the scoping studies had a small number of individual experiments and nonideal conditions, the permanganate decomposed up to 90% of the TPB. A free hydroxide concentration above 1.0 M is required for tank corrosion control. Simulant studies indicate no decrease in TPB decomposition by permanganate until pH 14. The simulant studies show an increase in TPB decomposition as the temperature of the solution is increased to 40 °C. The post-reaction analysis of previous simulant tests did not look at all of the organic degradation products. Investigations into what these organic products are and in what quantity will help guide determinations as to whether the downstream processing facilities are able to handle the material that will be generated. Study on the time frame for the reaction between permanganate and TPB should be investigated as the literature reports only extend out to two weeks reaction time. The permanganate treatment conditions indicate no corrosion control concerns and a longer timescale reaction may be needed for in-tank treatment. In addition, further study would be useful to identify a lower boundary condition for the ratio of TPB and oxidant. The simulant tests applied large excesses of permanganate, and this may be unnecessary. The size constraint of the tank means that there will be practical limitations on the amount of sodium permanganate that can be added to the tank. The amount of permanganate should be minimized as much as possible while still ensuring decomposition of the TPB to minimize the amount of manganese dioxide solids generated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗