Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TRAJECTORY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Time dependent semiclassical tunneling through one dimensional barriers using only real valued trajectories

The time independent semiclassical treatment of barrier tunneling has been understood for a very long time. Several semiclassical approaches to time dependent tunneling through barriers have also been presented. These typically involve trajectories for which the position variable is a complex function of time. In this paper, a method is presented that uses only real valued trajectories, thus avoiding the complications that can arise when complex trajectories are employed. This is accomplished by expressing the time dependent wave packet as an integration over momentum. The action function in the exponent in this expression is expanded to second order in the momentum. The expansion is around the momentum, p{sub 0{sup *}}, at which the derivative of the real part of the action is zero. The resulting Gaussian integral is then taken. The stationary phase approximation requires that the derivative of the full action is zero at the expansion point, and this leads to a complex initial momentum and complex tunneling trajectories. The “pseudo-stationary phase” approximation employed in this work results in real values for the initial momentum and real valued trajectories. The transmission probabilities obtained are found to be in good agreement with exact quantum results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analytic solutions for Asay foil trajectories with implications for ejecta source models and mass measurements

We consider the trajectory of an Asay foil ejecta diagnostic for scenarios where ejecta are produced at a singly shocked planar surface and fly ballistically through a perfect vacuum to the sensor. We do so by building upon a previously established mathematical framework derived for the analytic study of stationary sensors. First, we derive the momentum conservation equation for the problem, in a form amenable to accelerating sensors, in terms of a generic ejecta source model. The result is an integrodifferential equation of motion for the foil trajectory. This equation yields an easily calculable closed-form implicit solution for the foil trajectory in instant-production scenarios. From there, we derive a boundary condition that particle velocity distributions must satisfy if their associated foil trajectories are to exhibit a smooth initial acceleration, as occurs in some experiments. This condition is identical to one derived previously from a consideration of piezoelectric voltage data obtained in similar experiments. We also compare techniques for inferring accumulated ejecta masses from foil trajectories, first by deriving the exact solution, and then by quantifying the error imposed by a frequently used approximate solution (both subject to the assumption of instantaneous ejecta production). Finally, we examine the common practice of presenting inferred cumulative ejecta masses as a function of implied ejecta velocity, establishing the conditions under which this methodology is most meaningful.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonadiabatic dynamics with classical trajectories: The problem of an initial coherent superposition of electronic states

Advances in coherent light sources and development of pump–probe techniques in recent decades have opened the way to study electronic motion in its natural time scale. When an ultrashort laser pulse interacts with a molecular target, a coherent superposition of electronic states is created and the triggered electron dynamics is coupled to the nuclear motion. A natural and computationally efficient choice to simulate this correlated dynamics is a trajectory-based method where the quantum-mechanical electronic evolution is coupled to a classical-like nuclear dynamics. These methods must approximate the initial correlated electron–nuclear state by associating an initial electronic wavefunction to each classical trajectory in the ensemble. Different possibilities exist that reproduce the initial populations of the exact molecular wavefunction when represented in a basis. We show that different choices yield different dynamics and explore the effect of this choice in Ehrenfest, surface hopping, and exact-factorization-based coupled-trajectory schemes in a one-dimensional two-electronic-state model system that can be solved numerically exactly. Furthermore, this work aims to clarify the problems that standard trajectory-based techniques might have when a coherent superposition of electronic states is created to initialize the dynamics, to discuss what properties and observables are affected by different choices of electronic initial conditions and to point out the importance of quantum-momentum-induced electronic transitions in coupled-trajectory schemes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Broad-band trajectory mechanics

We present here a trajectory-based solution to the elastodynamic equation of motion that is valid across a wide range of seismic frequencies. That is, the derivation of the solution does not invoke a high-frequency assumption or require that the medium have smoothly varying properties. The approach, adopted from techniques used in quantum dynamics, produces a set of coupled ordinary differential equations for the trajectory, the slowness vector and the elastic wave amplitude along the ray path. The trajectories may be determined by a direct solution of the governing equations or derived as the by-product of a numerical wavefield simulation. Synthetic tests with interfaces and layers containing increasingly narrow transition zones indicate that the conventional high-frequency trajectories associated with the eikonal equation bend too sharply into high-velocity regions as the wavelength exceeds the transition zone width. Tests in a velocity model, based upon mapped structural surfaces from the Geysers geothermal field in California, indicate that discrepancies between high-frequency and broad-band trajectories can exceed several hundred metres at wavelengths of 1 Hz. An application to a crosswell tomographic imaging experiment demonstrates that the technique provides a basis for the seismic monitoring of fluid flow along narrow features such as fracture zones.

58 GEOSCIENCES↗

Rare behavior of growth processes via umbrella sampling of trajectories

We compute probability distributions of trajectory observables for reversible and irreversible growth processes. These results reveal a correspondence between reversible and irreversible processes, at particular points in parameter space, in terms of their typical and atypical trajectories. Thus key features of growth processes can be insensitive to the precise form of the rate constants used to generate them, recalling the insensitivity to microscopic details of certain equilibrium behavior. We obtained these results using a sampling method, inspired by the "s-ensemble" large-deviation formalism, that amounts to umbrella sampling in trajectory space. The method is a simple variant of existing approaches, and applies to ensembles of trajectories controlled by the total number of events. It can be used to determine large-deviation rate functions for trajectory observables in or out of equilibrium.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-473: A Patient-Specific QC Paradigm Based On Trajectory Log Files and DICOM Plan Files

Purpose: To evaluate a remote QC tool for monitoring treatment machine parameters and treatment workflow. Methods: The Varian TrueBeamTM linear accelerator is a digital machine that records machine axis parameters and MLC leaf positions as a function of delivered monitor unit or control point. This information is saved to a binary trajectory log file for every treatment or imaging field in the patient treatment session. A MATLAB analysis routine was developed to parse the trajectory log files for a given patient, compare the expected versus actual machine and MLC positions as well as perform a cross-comparison with the DICOM-RT plan file exported from the treatment planning system. The parsing routine sorts the trajectory log files based on the time and date stamp and generates a sequential report file listing treatment parameters and provides a match relative to the DICOM-RT plan file. Results: The trajectory log parsing-routine was compared against a standard record and verify listing for patients undergoing initial IMRT dosimetry verification and weekly and final chart QC. The complete treatment course was independently verified for 10 patients of varying treatment site and a total of 1267 treatment fields were evaluated including pre-treatment imaging fields where applicable. In the context of IMRT plan verification, eight prostate SBRT plans with 4-arcs per plan were evaluated based on expected versus actual machine axis parameters. The average value for the maximum RMS MLC error was 0.067±0.001mm and 0.066±0.002mm for leaf bank A and B respectively. Conclusion: A real-time QC analysis program was tested using trajectory log files and DICOM-RT plan files. The parsing routine is efficient and able to evaluate all relevant machine axis parameters during a patient treatment course including MLC leaf positions and table positions at time of image acquisition and during treatment.

60 APPLIED LIFE SCIENCES↗

Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

Purpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient’s chest wall. The purpose of this study was to characterize any trajectory-related differences in 3D x-ray dose distribution in a pendant target when imaged with different orbits. Methods: Two acquisition trajectories were evaluated: circular azimuthal (no-tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements. Simulations were performed with tungsten (W) filtration of a W-anode source; the simulated source flux was normalized to the measured exposure of a W-anode source. A water-filled cylindrical phantom was divided into 1 cm{sup 3} voxels, and the cumulative energy deposited was tracked in each voxel. Energy deposited per voxel was converted to dose, yielding the 3D distributed dose volumes. Additionally, three cylindrical phantoms of different diameters (10, 12.5, and 15 cm) and an anthropomorphic breast phantom, initially filled with water (mimicking pure fibroglandular tissue) and then with a 75% methanol-25% water mixture (mimicking 50–50 fibroglandular-adipose tissues), were used to simulate the pendant breast geometry and scanned on the physical system. Ionization chamber calibrated radiochromic film was used to determine the dose delivered in a 2D plane through the center of the volume for a fully 3D CT scan using the different orbits. Results: Measured experimental results for the same exposure indicated that the mean dose measured throughout the central slice for different diameters ranged from 3.93 to 5.28 mGy, with the lowest average dose measured on the largest cylinder with water mimicking a homogeneously fibroglandular breast. These results align well with the cylinder phantom Monte Carlo studies which also showed a marginal difference in dose delivered by a saddle trajectory in the central slice. Regardless of phantom material or filled fluid density, dose delivered by the saddle scan was negligibly different than the simple circular, no-tilt scans. The average dose measured in the breast phantom was marginally higher for saddle than the circular no tilt scan at 3.82 and 3.87 mGy, respectively. Conclusions: Not only does nontraditional 3D-trajectory CT scanning yield more complete sampling of the breast volume but also has comparable dose deposition throughout the breast and anterior chest volume, as verified by Monte Carlo simulation and physical measurements.

60 APPLIED LIFE SCIENCES↗

TU-CD-304-02: Planning and Delivery of Fully Dynamic Trajectory Modulated Arc Therapy On Pituitary Adenoma: Dosimetric Advantages Over Conventional Volumetric Modulated Arc Therapy

Purpose: To assess the potential benefit of trajectory modulated arc therapy (TMAT) for treatments of small benign intracranial tumor, pituitary adenoma. Methods: A TMAT planning platform that incorporates complex source motion trajectory involving synchronized gantry rotation with translational and rotational couch movement was used for the study. The platform couples an interactive trajectory generation tool with a VMAT algorithm that performs multi-resolution, progressive sampling MLC optimization on a user-designed trajectory. A continuous couch rotation of 160° angular span with ±20° mini gantry arcs was used to emulate a non-coplanar horizontal arc-like trajectory. Compared to conventional non-coplanar gantry arcs (60°-100° gantry rotation with couch kicks), TMAT limited the unnecessary low to medium dose spread in the anterior and posterior directions, where primary OARs (e.g., brainstem, optic chiasm, optic nerves, and lens) are in close proximity to the targeted pituitary tumor volume. For 5 standard fractionation pituitary adenoma cases (50.4Gy/28fractions), TMAT and non-coplanar VMAT plans were generated and compared under equivalent objectives/constraints. TMAT delivery was implemented and demonstrated on Varian TrueBeam via XML scripts. Results: Both techniques showed good target coverage while OARs were able to meet the constraints on QUANTEC guidelines. Notably, TMAT decreased the dose deposition in the anterior-to-posterior direction surrounding PTV. TMAT significantly reduced the mean doses on brainstem, optic nerves, eyes and lens by 47.29%±13.17%, 28.51%±8.68%, 80.82%±8.71% and 65.38%±19.99% compared with VMAT, all p≤0.01. Percentage reductions of maximum point dose in eyes and lens were 75.68%±10.30% and 70.72%±18.62% respectively for TMAT versus VMAT, all p≤0.01. A representative isocentric TMAT pituitary plan was delivered via an XML script with 200 control points and 282 MUs. Conclusion: Deliverable TMAT plans were achieved in developer mode in TrueBeam. TMAT was shown to be superior for pituitary adenoma irradiation in terms of OARs sparing.

60 APPLIED LIFE SCIENCES↗

SU-F-T-503: Trajectory Modulated Arc Therapy of Intracranial Lesions: Development of a Standardized Path-Based Technique for Fully Dynamic Couch-Gantry Modulated Treatments

Purpose: The integration of couch motion during arc delivery is necessitated to enable irradiation trajectories such as coronal arcs, and to enhance the geometrical sampling for dynamic deliveries to the highest extent. To enable such capability, a platform of Trajectory Modulated Arc Therapy (TMAT) is developed in conjunction with standardized noncollisional dynamic path-set for irradiation of intracranial lesions. Methods: A generalized path-set was constructed through the combination of sagittal arcs (45 degrees from the CAX), axial arcs, and coronal arcs produced through modulation of the dynamic rotation of couch. The standardized path was implemented in a contiguous manner enabling the formation of fully automated sub-trajectories to provide maximal geometrical convergence with minimal number of arcs. Progressive sampling technique is used for direct aperture optimization of the MLCs and the selection of couch positions across the control points. Dosimetry of the resulting plans was assessed relative to clinically delivered plans. Using the TrueBeam Developer Mode, plan deliverability was tested. Results: Treatment planning of TMAT sub-trajectories for central, anterior and posterior tumor sites with volumes ranging from 4.75cc to 107cc demonstrated radically reduced doses to the critical OARs when compared to the clinically treated VMAT. Specifically, percentage reduction in mean dose for critical organs such as brainstem, cochlea, and optic nerve are found to be as low as 74±15%, 50±26% and 74±30% respectively as compared to VMAT. Conformity Index, defined as the ratio of tumor volume (VPTV) and 100% dose volume (V(D100%)), was reduced up to 12% while the Gradient Index, defined as V(D100%)/V(D50%), was concurrently improved by up to 14%. Conclusion: An automated standardized trajectory with dynamically modulated couch-gantry arcs has been developed for intracranial radiotherapy. Through the incorporation of coronal arcs, it is demonstrated that significantly reduced OAR doses can be achieved relative to clinically treated patient plans via VMAT. Research Grant Funding Support by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

PANTHER: Trajectory Analysis

We want to organize a body of trajectories in order to identify, search for, classify and predict behavior among objects such as aircraft and ships. Existing comparison functions such as the Fréchet distance are computationally expensive and yield counterintuitive results in some cases. We propose an approach using feature vectors whose components represent succinctly the salient information in trajectories. These features incorporate basic information such as total distance traveled and distance between start/stop points as well as geometric features related to the properties of the convex hull, trajectory curvature and general distance geometry. Additionally, these features can generally be mapped easily to behaviors of interest to humans that are searching large databases. Most of these geometric features are invariant under rigid transformation. We demonstrate the use of different subsets of these features to identify trajectories similar to an exemplar, cluster a database of several hundred thousand trajectories, predict destination and apply unsupervised machine learning algorithms.

42 ENGINEERING↗

Six Degrees of Freedom (6DOF) Simulations of Supersonic Fragment Trajectories

In this report a process using existing technologies at Sandia National Laboratories (SNL) to simulate the six degrees-of-freedom (6DOF) trajectories of explosive fragments is described and tested. First, aerodynamic forces and moments as functions of orientation are computed using the SIERRA/Aero supersonic flow solver. The forces and moments are normalized and tabulated in a database. Second, this the aerodynamic coefficient database is imported into a 6DOF rigid body dynamics solver in order to compute the resulting trajectories. The supersonic flow simulations are tested for simple geometries and show good agreement with literature values. The simulation procedure is then demonstrated for an example fragment. The results of the example fragment indicate that the distance traveled in the early ight (from 2.5 km/s until decreasing down to 1 km/s) varies widely depending on the initial orientations. The fragment trajectory distribution and steady tumbling rate is explored. The study indicates that a 6DOF analysis will yield information about a spread of possible trajectories, while using an average drag coefficient can only represent the most likely trajectory.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Lunar Flight Study Series: Volume 7. Earth-Moon Transit Studies Based on Ephemeris Data and Using Best Available Computer Program: Principles for Reducing Earth-Moon Trajectory Analysis to Fundamentals - 2

This report presents an empirical investigation of earth-to-moon trajectories. The primary objective is to uncover relationships that result in the reduction of mission analysis or trajectory analysis problems to fundamentals. It is considered imperative that the results be accurate to the extent that any relationships that are uncovered are not brought about by simplifying or unrealistic assumptions. Consequently, the model used is as accurate as is presently available for use and the computations are performed under strict error controls. Procedures are reasonable from the engineering viewpoint. Some very helpful principles are uncovered. These may be briefly stated as follows: 1) Trajectories of constant flight time to the moon (in the 66 hour to 90 hour range), and arriving within a few minutes of the same time pass over a common point on the moon regardless of the arrival altitude and inclination, This common point of passage for such a family of trajectories is arbitrarily referred to as a VERTEX point; 2) These VERTEX points lie within a bounded region on the lunar surface as arrival time varies throughout the years, for a given flight time or flight time spread; 3) Increasing flight time results primarily in a longitude shift of the VERTEX point for a given arrival time; 4) Launch azimuth should be treated as a strong parameter regarding its influence on the vertex. Launch azimuth variations up to +/- 20 degrees about 90 degrees can shift the vertex as much as 3 degrees in latitude even when one is free to pick launch time, coast time, and S-IVB burn time appropriately with launch azimuth; and 5) The locus of periselenum, as arrival inclination takes on all possible values, is nearly circular about the vertex point for a given arrival altitude. A publication is now in preparation that applies these principles to much advantage in the solution of various trajectory analysis problems.

LUNAR FLIGHT↗

An analytic guidance technique for planetary and lunar approach trajectories.

An explicit, analytic guidance technique is developed for the hyperbolic approach phases of interplanetary and lunar spacecraft trajectories. The guidance technique is based upon a first-order analytic solution for the perturbed planet-centered (or moon-centered) trajectory. This trajectory is represented as the sum of two components: (1) the unperturbed osculating hyperbola at pericenter, and (2) first-order position and velocity perturbations due to gravitational effects of the sun and other planets. A closed-form analytic approximation for these perturbations valid for the entire approach trajectory is derived, thereby eliminating the need for numerical integration of the equations of motion. By means of this analytic trajectory model, the approach guidance problem is reduced to an equivalent two-body problem. The guidance objectives are specified in terms of actual, attainable conditions at pericenter, and the required corrective velocity is determined explicitly for both fixed and variable times of arrival.

Carlson, N. A.↗

Encounter trajectory design for SEP rendezvous with low mass celestial bodies.

This paper shows the considerations which precede and affect encounter trajectory design and the impact of this design on propulsion system performance requirements and interplanetary trajectory design. Representative missions selected to illustrate the problems and characteristics of encounter trajectory design are a Mercury Orbiter, Eros Rendezvous, Encke Rendezvous, and Ceres Orbiter. The paper shows that for SEP missions, particularly for low mass celestial bodies, the encounter trajectory may be freely specified to a large extent to satisfy mission goals rather than being dictated by a rigid interplanetary trajectory design.

Driver, J. M.↗

Space Trajectory Error Analysis Program (STEAP) for halo orbit missions. Volume 2: Programmer's manual

The six month effort was responsible for the development, test, conversion, and documentation of computer software for the mission analysis of missions to halo orbits about libration points in the earth-sun system. The software consisting of two programs called NOMNAL and ERRAN is part of the Space Trajectories Error Analysis Programs. The program NOMNAL targets a transfer trajectory from earth on a given launch date to a specified halo orbit on a required arrival date. Either impulsive or finite thrust insertion maneuvers into halo orbit are permitted by the program. The transfer trajectory is consistent with a realistic launch profile input by the user. The second program ERRAN conducts error analyses of the targeted transfer trajectory. Measurements including range, doppler, star-planet angles, and apparent planet diameter are processed in a Kalman-Schmidt filter to determine the trajectory knowledge uncertainty.

Byrnes, D. V.↗

Four-body trajectory optimization

A comprehensive optimization program has been developed for computing fuel-optimal trajectories between the earth and a point in the sun-earth-moon system. It presents methods for generating fuel optimal two-impulse trajectories which may originate at the earth or a point in space and fuel optimal three-impulse trajectories between two points in space. The extrapolation of the state vector and the computation of the state transition matrix are accomplished by the Stumpff-Weiss method. The cost and constraint gradients are computed analytically in terms of the terminal state and the state transition matrix. The 4-body Lambert problem is solved by using the Newton-Raphson method. An accelerated gradient projection method is used to optimize a 2-impulse trajectory with terminal constraint. The Davidon's Variance Method is used both in the accelerated gradient projection method and the outer loop of a 3-impulse trajectory optimization problem.

Pu, C. L.↗

Fixed-range optimum trajectories for short-haul aircraft

An algorithm, based on the energy-state method, is derived for calculating optimum trajectories with a range constraint. The basis of the algorithm is the assumption that optimum trajectories consist of, at most, three segments: an increasing energy segment (climb); a constant energy segment (cruise); and a decreasing energy segment (descent). This assumption allows energy to be used as the independent variable in the increasing and decreasing energy segments, thereby eliminating the integration of a separate adjoint differential equation and simplifying the calculus of variations problem to one requiring only pointwise extremization of algebraic functions. The algorithm is used to compute minimum fuel, minimum time, and minimum direct-operating-cost trajectories, with range as a parameter, for an in-service CTOL aircraft and for an advanced STOL aircraft. For the CTOL aircraft and the minimum-fuel performance function, the optimum controls, consisting of air-speed and engine power setting, are continuous functions of the energy in both climb and descent as well as near the maximum or cruise energy. This is also true for the STOL aircraft except in the descent where at one energy level a nearly constant energy dive segment occurs, yielding a discontinuity in the airspeed at that energy. The reason for this segment appears to be the relatively high fuel flow at idle power of the engines used by this STOL aircraft. Use of a simplified trajectory which eliminates the dive increases the fuel consumption of the total descent trajectory by about 10 percent and the time to fly the descent by about 19 percent compared to the optimum.

Erzberger, H.↗

Space shuttle engineering and operations support. ALT separation reference trajectories for tailcone on orbiter forward and aft CG configurations. Mission planning, mission analysis and software formulation

A preflight analysis of the ALT separation reference trajectories for the tailcone on, forward, and aft cg orbiter configurations is documented. The ALT separation reference trajectories encompass the time from physical separation of the orbiter from the carrier to orbiter attainment of the maximum ALT interface airspeed. The trajectories include post separation roll maneuvers by both vehicles and are generated using the final preflight data base. The trajectories so generated satisfy all known separation design criteria and violate no known constraints. The requirement for this analysis is given along with the specifications, assumptions, and analytical approach used to generate the separation trajectories. The results of the analytical approach are evaluated, and conclusions and recommendations are summarized.

Glenn, G. M.↗