Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TPC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

275 records · Page 16

Particle hit clustering and identification using point set transformers in liquid argon time projection chambers

Liquid argon time projection chambers are often used in neutrino physics and dark-matter searches because of their high spatial resolution. The images generated by these detectors are extremely sparse, as the energy values detected by most of the detector are equal to 0, meaning that despite their high resolution, most of the detector is unused in a particular interaction. Instead of representing all of the empty detections, the interaction is usually stored as a sparse matrix, a list of detection locations paired with their energy values. Traditional machine learning methods that have been applied to particle reconstruction such as convolutional neural networks (CNNs), however, cannot operate over data stored in this way and therefore must have the matrix fully instantiated as a dense matrix. Operating on dense matrices requires a lot of memory and computation time, in contrast to directly operating on the sparse matrix. We propose a machine learning model using a point set neural network that operates over a sparse matrix, greatly improving both processing speed and accuracy over methods that instantiate the dense matrix, as well as over other methods that operate over sparse matrices. Compared to competing state-of-the-art methods, our method improves classification performance by 14%, segmentation performance by more than 22%, while taking 80% less time and using 66% less memory. Compared to state-of-the-art CNN methods, our method improves classification performance by more than 86%, segmentation performance by more than 71%, while reducing runtime by 91% and reducing memory usage by 61%.

calibration and fitting methods↗

Lifetime study of the ColdADC for the Deep Underground Neutrino Experiment

ColdADC is a custom ASIC digitizer implemented in 65 nm CMOS technology using specialized techniques for long-term reliability in cryogenic environments. ColdADC was developed for use in the DUNE Far Detector complex, which will consist of four liquid argon time projection chambers. Each contains 17 kilotons liquid argon as the target material in order to measure neutrino oscillations. Approximately 40,000 ColdADC ASICs will be installed for DUNE in the first two large detectors and will be operated at cryogenic temperatures during the experiment without replacement. The lifetime of the ColdADC is a critical parameter affecting the data quality and physics sensitivity of the experiment. A measurement of the lifetime of the ColdADC was carried out, and the results shown in this paper assure orders of magnitude longer lifetime of the ColdADC than the planned operation time of the detectors.

Front-end electronics for detector readout↗

UA'(1): The search for low-mass dark matter in liquid xenon / Infrared Light for Liquid Xenon TPCs

Liquid xenon-based time projection chambers are used in a variety of applications spanning from the search for dark matter or signals from coherent neutrino-nucleus scattering, to detectors used in medicine and for nuclear non-proliferation. Extending the useful energy range of these detectors down to lower energies will prove extremely useful for such applications. However, various sources of single- and few-electron backgrounds limit the utility of experiments such as LZ and XENONnT to searches of lighter dark matter articles in the MeV mass range. These same backgrounds also limit their utility to measure signals from coherent neutrino-nucleus scattering of solar boron-8 neutrinos and Galactic supernovae. This research worked on multiple mitigation strategies to reduce these backgrounds, through improved xenon purity, infrared irradiation, and an improved theoretical understanding. Multiple dedicated liquid xenon setups were built to execute those tests, and data was successfully taken. Liquid xenon purity was shown to have an important impact, but infrared irradiation did not reduce these backgrounds.

47 OTHER INSTRUMENTATION↗

Participation in Intensity Frontier Neutrino Physics (closeout report)

The flagship currently-running experiment at Fermilab is the NuMI Off-axis νe Appearance (NOvA) experiment. Together with the (complementary) T2K experiment in Japan, it provides the opportunity for improved measurement precision on neutrino mixing parameters and addresses topics of strong interest: whether neutrino masses follow a normal (NH) or inverted (IH) hierarchy; whether the ν 3 state contains a symmetric mixture of ν µ and ν τ (“maximal mixing,” pointing to a possible new symmetry of nature), or, if not, what is the octant of θ 23 ; and whether neutrino mixing violates CP symmetry. Recent results from both experiments suggest we may be on the verge of important discoveries. Towards the end of the decade, these experiments will be superseded by DUNE in the U.S. and HyperK in Japan.

2x2↗

Data Compression in the NEXT-100 Data Acquisition System

NEXT collaboration detectors are based on energy measured by an array of photomultipliers (PMT) and topological event filtering based on an array of silicon photomultipliers (SiPMs). The readout of the PMT sensors for low-frequency noise effects and detector safety issues requires a grounded cathode connection that makes the readout AC-couple with variations in the signal baseline. Strict detector requirements of energy resolution better than 1% FWHM require a precise baseline reconstruction that is performed offline for data analysis and detector performance characterization. Baseline variations make it inefficient to apply traditional lossy data compression techniques, such as zero-suppression, that help to minimize data throughput and, therefore, the dead time of the system. However, for the readout of the SiPM sensors with less demanding requirements in terms of accuracy, a traditional zero-suppression is currently applied with a configuration that allows for a compression ratio of around 71%. The third stage in the NEXT detectors program, the NEXT-100 detector, is a 100 kg detector that instruments approximately five times more PMT sensors and twice the number of SiPM sensors than its predecessor, the NEXT-White detector, putting more pressure in the DAQ throughput, expected to be over 900 MB/s with the current configuration, which will worsen the dead time of the acquisition data system. This paper describes the data compression techniques applied to the sensor data in the NEXT-100 detector, which reduces data throughput and minimizes dead time while maintaining the event rate to the level of its predecessor, around 50 Hz.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗