Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Environmental monitoring for Space Station WP01

External contamination monitoring instrumentation for the Space Station work package one (WP01) elements, were imposed on the contractor as deliverable hardware. The monitoring instrumentation proposed by the WP01 contractor in response to the contract requirement includes both real time measurements and passive samples. Real time measurement instrumentation consists of quartz crystal microbalances for molecular deposition, ion gaseous species identification. Internal environmental contamination monitoring for particulates is included in both Lab and HAB modules. Passive samples consists of four sample mounting plates mounted external to the Space Station modules, two on the U.S. LAB, and two on the HAB module.

Zwiener, J. M.↗

Neural Networks Used to Compare Designed and Measured Time-Average Patterns

Electronic time-average holograms are convenient for comparing the measured vibration modes of fan blades with those calculated by finite-element models. At the NASA Lewis Research Center, neural networks recently were trained to perform what had been a simple visual comparison of the predictions of the design models with the measurements. Finite-element models were used to train neural networks to recognize damage and strain information encoded in subtle changes in the time-average patterns of cantilevers. But the design-grade finite element models were unable to train the neural networks to detect damage in complex blade shapes. The design-model-generated patterns simply did not agree well enough with the measured patterns. Instead, hybrid-training records, with measured time-average patterns as the input and model-generated strain information as the output, were used to effect successful training.

Decker, Arthur J.↗

Constraints on Ho from Time-Delay Measurements of PG1115+080

The observations that were performed as part of the award titled: Constraints on Ho From Time-Delay Measurements of PG1115+080 resulted in several scientific publications and presentations. We list these publications and presentations and provide brief description of the important science presented in them.

Chartas, George↗

Fluorescence time profile measurement of LAB based liquid scintillator in response to medium relativistic ion particles

Liquid scintillator is widely used in particle physics experiments due to its high light yield, good timing resolution, scalability and low cost. Certain liquid scintillators exhibit pulse shape discrimination capabilities because of difference in fluorescence timing properties induced by different particles. Its fluoresence timing properties have been measured mostly for radioactive decay sources at MeV energies. Here, we present a novel measurement of fluorescence time properties of Linear Alkyl Benzene (LAB) based liquid scintillator in response to high-energy ions of hydrogen (Z = 1), helium (Z = 2) and krypton at around 200–300 MeV/u for the first time. We compared the results to those from radioactive sources and observed a distinct dE / dX dependence, regardless of the particle type. These findings are essential for physics searches such as the diffuse supernova neutrino background in large liquid scintillator detectors like JUNO, and are also critical towards understanding the underlying scintillation timing mechanism.

Ion identification systems↗

Electronics for a Picosecond Time-of-flight Measurement

TITLE: Electronics for a Picosecond Time-of-flight Measurement ABSTRACT: Time-of-flight (TOF) detectors have historically been used as part of the particle identification capability of multi-purpose particle physics detectors. An accurate time measurement, combined with a momentum measurement based on the curvature of the track in a magnetic field, is often sufficient to determine the particle's mass, and thus its identity. Such detectors typically have measured the particle flight time extremely precisely, with an uncertainty of one hundred trillionths of a second (also referred to as 100 picoseconds). To put this in perspective it would be like counting all the people on the Earth and getting it right within 1 person! Another use of TOFs is to measure the vertex of the event, which is the location along the beam line where the incoming particles (typically protons) collide. This vertex positon is a well measured quantity for events where the protons collide “head on” as the outgoing particles produced when you blast the proton apart can be used to trace back to a vertex point from which they originated. More frequently the protons just strike a glancing blow and remain intact—in this case they are nearly parallel to the beam and you cannot tell their vertex without this ability to precisely measure the time of flight of the protons. Occasionally both happen in the same event, that is, a central system and two protons are produced. But are they from the same collision, or just a boring background where more than one collision in the same bunch crossing conspire to fake the signal of interest? That’s where the timing of the protons comes into play. The main idea is to measure the time it takes for the two protons to reach TOF detectors positioned equidistant from the center of the main detector. If the vertex is displaced to one side than that detector will measure a shorter time while the other side detector will measure a correspondingly longer time. Taking into account the speed of the particles, which is very close to the speed of light, an accuracy of 100 ps gives a vertex measurement of a few cm or a little more than an inch. At the Large Hadron Collider, where there are up to a hundred billion protons per bunch, and the collision region is compressed to a few inches, that is just not good enough. A higher level of precision is needed to determine whether the vertex of the protons and that of the central system are the same. A factor 10 improvement in the timing measurement to the 10 trillionths of a second level, for example would give the requisite 10 times improvement in the vertex measurement. An accurate measurement of the flight time depends on three key elements: the radiator that produces light when the proton passes through it, the photo-sensor that converts the light to an electrical signal, and the electronics that convert this electrical signal into a time measurement with a compact recordable format. With recent improvements in detector design featuring a series of quartz radiators connected to a micro-channel plate photomultiplier tube, this superior measurement capability is within reach if the readout electronics are sufficiently performant. As a result of the funding of this proposal, we have achieved our primary goals. 1) We have developed from scratch or improved upon existing designs of the full chain of electronics that can maintain the performance of a TOF detector from the output of the photo-sensor to the recording of a compressed data packet containing the timing information. We have accomplished this with a cost effective modular approach such that some or all of the components in the chain could easily be adapted for use in diverse particle physics experiments or in other areas where precise timing is required, such as medical and homeland security devices.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New method for measuring time-resolved spectra of lanthanide emission using square-wave excitation

A method using modulated continuous wave (CW) visible laser to measure time-resolved fluorescence spectra of trivalent rare-earth ions has been developed. Electro-optic modulator was used to modulate the CW pumping laser with a rise time of 2 μs. CW Nd{sup 3+} lasers were used as examples to present the method. Upconversion dynamic process of Ho{sup 3+} was studied utilizing a 532 nm CW laser. Quantum cutting dynamic process from Tb{sup 3+} to Yb{sup 3+} was analyzed by a 473 nm CW laser. This method can be applied to any CW laser such as He-Ne laser, Ar{sup +} laser, Kr{sup +} laser, Ti:sapphire laser, etc.

36 MATERIALS SCIENCE↗

High-time resolution measurements of solar wind heavy ions with SOHO/CELIAS/CTOF

The Charge Time-Of-Flight (CTOF) mass spectrometer as part of the Charge, ELement and Isotope Analysis System (CELIAS) onboard the SOlar and Heliospheric Observatory (SOHO) is designed to measure the kinetic properties and elemental/ionic composition of solar wind ions heavier than protons, which we refer to as heavy ions. This is achieved by the combined measurements of the energy-per-charge, the time-of-flight and the energy of incident ions. The CTOF instrument combines a remarkable time-of-flight resolution with a large effective area and a high measurement cadence. This allows to determine the Velocity Distribution Functions (VDFs) of a wide range of heavy ions with 5-minute time resolution which ensures that the complete VDF is measured under nearly identical solar wind and magnetic field conditions. For the measurement period between Day Of Year (DOY) 150 and 220 in 1996, which covers a large part of the instrument’s short life time, we analyzed VDFs of solar wind iron Fe{sup 8+}, Fe{sup 9+} and Fe{sup 10+} for differential streaming relative to the solar wind proton speed measured simultaneously with the CELIAS Proton Monitor (PM). We find an increasing differential streaming with increasing solar wind proton speed for all investigated ions up to ion-proton velocity differences of 30 - 50 km s{sup −1} at proton velocities of 500 km s{sup −1}, which is contradictory to an earlier CTOF study by [7]. We believe this difference is because in this study we used raw Pulse Height Analysis (PHA) data with a significantly increased mass and mass-per-charge resolution compared to the earlier used onboard preprocessed data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wall loss of atomic nitrogen determined by ionization threshold mass spectrometry

In the afterglow of an inductively coupled N{sub 2} plasma, relative N atom densities are measured by ionization threshold mass spectrometry as a function of time in order to determine the wall loss time t{sub wN} from the exponential decay curves. The procedure is performed with two mass spectrometers on different positions in the plasma chamber. t{sub wN} is determined for various pressures, i.e., for 3.0, 5.0, 7.5, and 10 Pa. For this conditions also the internal plasma parameters electron density n{sub e} and electron temperature T{sub e} are determined with the Langmuir probe and the rotational temperature T{sub rot}{sup N{sub 2}} of N{sub 2} is determined with the optical emission spectroscopy. For T{sub rot}{sup N{sub 2}}, a procedure is presented to evaluate the spectrum of the transition υ{sup ′}=0→υ{sup ″}=2 of the second positive system (C{sup 3}Π{sub u}→B{sup 3}Π{sub g}) of N{sub 2}. With this method, a gas temperature of 610 K is determined. For both mass spectrometers, an increase of the wall loss times of atomic nitrogen with increasing pressure is observed. The wall loss time measured with the first mass spectrometer in the radial center of the cylindrical plasma vessel increases linearly from 0.31 ms for 3 Pa to 0.82 ms for 10 Pa. The wall loss time measured with the second mass spectrometer (further away from the discharge) is about 4 times higher. A model is applied to describe the measured t{sub wN.} The main loss mechanism of atomic nitrogen for the considered pressure is diffusion to the wall. The surface loss probability β{sub N} of atomic nitrogen on stainless steel was derived from t{sub wN} and is found to be 1 for the present conditions. The difference in wall loss times measured with the mass spectrometers on different positions in the plasma chamber is attributed to the different diffusion lengths.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Passive Time Coincidence Measurements with HEU and DU Metal Castings

A Department of Energy sponsored Oak Ridge National Laboratory/Y-12 National Security Complex program of passive time coincidence measurements has been initiated at Y-12 to evaluate the ability to determine the presence of high enriched uranium (HEU) and distinguish it from depleted uranium (DU). This program uses the Nuclear Materials Identification System (NMIS) without an active interrogation source. Previous passive NMIS measurements with Pu metal and Pu oxide have been successful in determining the Pu mass, assuming a known 240Pu content. The spontaneous fission of uranium metal is considerably lower than Pu and measurements of this type have been performed at Lawrence Livermore National Laboratory. This work presents results of measurements of HEU and DU metal castings using moderated 3He detectors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Time-resolved measurement of photon emission during fast crack propagation in three-point bending fracture of silica glass and soda lime glass

Simultaneous time-resolved measurements of photon emission (PE) and fast crack propagation upon bending fracture were conducted in silica glass and soda lime glass. Observation of fracture surfaces revealed that macroscopic crack propagation behavior was similar between the silica glass and soda lime glass when fracture loads for these specimens were comparable and cracks propagated without branching. However, a large difference in the PE characteristics was found between the two glasses. In silica glass, PE (645–655 nm) was observed during the entire crack propagation process, whereas intense PE (430–490 nm and 500–600 nm) was observed during the initial stages of propagation. In contrast, only weak PE was detected in soda lime glass. These results show that there is a large difference in the atomic processes involved in fast crack propagation between these glasses, and that PE can be used to study brittle fracture on the atomic scale.

36 MATERIALS SCIENCE↗

Plastic scintillation detectors for time-of-flight mass measurements

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting Cyclotron Laboratory (NSCL) by increasing the number of photomultiplier tubes that read out their light signals to four per detector, and characterized them in a test experiment with 48 Ca beam at the NSCL. The new detectors achieved a time resolution (σ) of 7.5 ps. We systematically investigated different factors that affect their timing performance. In addition, we evaluated the ability of positioning the hitting points on the scintillator using the timing information and obtained a resolution (σ) below 1 mm for well-defined beam spots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive Time Coincidence Measurements with Assemblies of HEU and DU Castings

Five highly enriched (93.2 wt% 235U) uranium (HEU) and three depleted (0.2 wt% 235U) uranium (DU) castings were available for passive time coincidence measurements with two arrays of eight total liquid scintillation detectors and two arrays of 32 total moderated 3He detectors. In addition to measurements with each type of casting, measurements were also performed with both types of castings intermingled. The spontaneous fission rate for the casting is primarily due to the presence of 238U. Thus, the DU castings have ~15 times more spontaneous fission that the HEU castings with very little addition in multiplication with each addition of a DU casting. The characteristic time behavior of the fission chain multiplication process is determined by the 235U. The presence of the DU castings in these assemblies has three physical effects: provision of an additional source of neutrons to initiate fission chains in the HEU, reflection of neutrons back into the HEU, and shielding of the detectors from fission chain neutrons and gammas. The effects are investigated within the context of the time coincidence distributions using the signal-triggered multiplets and Feynman variances.

36 MATERIALS SCIENCE↗

Time-domain measurement of a self-amplified spontaneous emission free-electron laser with an energy-chirped electron beam and undulator tapering

We report, with an unequivocal time-domain measurement, that an appropriately chosen undulator taper can compensate for an electron beam longitudinal energy-chirp in a free-electron laser amplifier, leading to the generation of single-spike radiation close to the Fourier limit. The measurements were taken using the frequency-resolved optical gating technique by employing an advanced transient-grating diagnostic geometry. The reconstructed longitudinal radiation characteristics are compared in detail to prediction from time-dependent three-dimensional simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heat-flux measurements for the rotor of a full-stage turbine. II - Description of analysis technique and typical time-resolved measurements

An analytical technique for obtaining the time-resolved heat flux of a turbine blade is applied to the case of a TFE 731-2 hp full-stage rotating turbine. In order to obtain the heat flux values from the thin film gage temperature histories, a finite difference procedure is used to solve the heat equation with variable thermal properties. After setting out the data acquisition and analysis procedures, their application is illustrated for three midspan locations on the blade and operation at the design flow function. Results demonstrate that the magnitude of the heat flux fluctuation due to vane-balde interaction is large by comparison to the time-averaged heat flux at all investigated locations; FFT of a portion of the heat flux record illustrates that the dominant frequencies occur at the wake-cutting frequency and its harmonics.

Dunn, M. G.↗

Automating the interpretation of PM 2.5 time–resolved measurements using a data–driven approach

The rapid development of automated measurement equipment enables researchers to collect greater quantities of time-resolved data from indoor and outdoor environments. While significant, the interpretation of the resulting data can be a time-consuming effort. This paper introduces an automated process of interpreting PM 2.5 time-resolved data and differentiating PM 2.5 emissions resulting from indoor and outdoor sources. Here, we use Random Forest (RF), a machine learning approach, to study a dataset of 836 indoor emission events that occurred over a 2-week period in 18 apartments in California. In this paper, we show model development and evaluate its performance as the sample size and source vary. We discuss the characteristics of the dataset that tended to help the source identification and why. For example, we show that data from many events and from different apartments are essential for the model to be suitable for analyzing a new separate dataset. We also show that longitudinal data appear to be more helpful than the time frequency of measurements within a given apartment. We use the resulting RF model to analyze PM 2.5 data of an entirely separate dataset collected from 65 new homes in California. The RF model identifies 442 indoor emission events, with only a few misidentifications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model for Correlating Real-Time Survey Results to Contaminant Concentrations - 12183

The U.S. Environmental Protection Agency (EPA) Superfund program is developing a new Counts Per Minute (CPM) calculator to correlate real-time survey results, which are often expressed as counts per minute, to contaminant concentrations that are more typically provided in risk assessments or for cleanup levels, usually expressed in pCi/g or pCi/m{sup 2}. Currently there is no EPA guidance for Superfund sites on correlating count per minute field survey readings back to risk, dose, or other ARAR based concentrations. The CPM calculator is a web-based model that estimates a gamma detector response for a given level of contamination. The intent of the CPM calculator is to facilitate more real-time measurements within a Superfund response framework. The draft of the CPM calculator is still undergoing internal EPA review. This will be followed by external peer review. It is expected that the CPM calculator will at least be in peer review by the time of WM2012 and possibly finalized at that time. The CPM calculator should facilitate greater use of real-time measurement at Superfund sites. The CPM calculator may also standardize the process of converting lab data to real time measurements. It will thus lessen the amount of lab sampling that is needed for site characterization and confirmation surveys, but it will not remove the need for sampling. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TWO ACCURATE TIME-DELAY DISTANCES FROM STRONG LENSING: IMPLICATIONS FOR COSMOLOGY

Strong gravitational lenses with measured time delays between the multiple images and models of the lens mass distribution allow a one-step determination of the time-delay distance, and thus a measure of cosmological parameters. We present a blind analysis of the gravitational lens RXJ1131-1231 incorporating (1) the newly measured time delays from COSMOGRAIL, the COSmological MOnitoring of GRAvItational Lenses, (2) archival Hubble Space Telescope imaging of the lens system, (3) a new velocity-dispersion measurement of the lens galaxy of 323 {+-} 20 km s{sup -1} based on Keck spectroscopy, and (4) a characterization of the line-of-sight structures via observations of the lens' environment and ray tracing through the Millennium Simulation. Our blind analysis is designed to prevent experimenter bias. The joint analysis of the data sets allows a time-delay distance measurement to 6% precision that takes into account all known systematic uncertainties. In combination with the Wilkinson Microwave Anisotropy Probe seven-year (WMAP7) data set in flat wCDM cosmology, our unblinded cosmological constraints for RXJ1131-1231 are H{sub 0}=80.0{sup +5.8}{sub -5.7} km s{sup -1} Mpc{sup -1}, {Omega}{sub de} = 0.79 {+-} 0.03, and w=-1.25{sup +0.17}{sub -0.21}. We find the results to be statistically consistent with those from the analysis of the gravitational lens B1608+656, permitting us to combine the inferences from these two lenses. The joint constraints from the two lenses and WMAP7 are H{sub 0}=75.2{sup +4.4}{sub -4.2} km s{sup -1} Mpc{sup -1}, {Omega}{sub de}=0.76{sup +0.02}{sub -0.03}, and w = -1.14{sup +0.17}{sub -0.20} in flat wCDM, and H{sub 0}=73.1{sup +2.4}{sub -3.6} km s{sup -1} Mpc{sup -1}, {Omega}{sub {Lambda}}=0.75{sup +0.01}{sub -0.02}, and {Omega}{sub k}=0.003{sup +0.005}{sub -0.006} in open {Lambda}CDM. Time-delay lenses constrain especially tightly the Hubble constant H{sub 0} (5.7% and 4.0% respectively in wCDM and open {Lambda}CDM) and curvature of the universe. The overall information content is similar to that of Baryon Acoustic Oscillation experiments. Thus, they complement well other cosmological probes, and provide an independent check of unknown systematics. Our measurement of the Hubble constant is completely independent of those based on the local distance ladder method, providing an important consistency check of the standard cosmological model and of general relativity.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterizing sources and emissions of volatile organic compounds in a northern California residence using space- and time-resolved measurements

We investigate source characteristics and emission dynamics of volatile organic compounds (VOCs) in a single-family house in California utilizing time- and space-resolved measurements. About 200 VOC signals, corresponding to more than 200 species, were measured during 8 weeks in summer and five in winter. Spatially resolved measurements, along with tracer data, reveal that VOCs in the living space were mainly emitted directly into that space, with minor contributions from the crawlspace, attic, or outdoors. Time-resolved measurements in the living space exhibited baseline levels far above outdoor levels for most VOCs; many compounds also displayed patterns of intermittent short-term enhancements (spikes) well above the indoor baseline. Compounds were categorized as "high-baseline" or "spike-dominated" based on indoor-to-outdoor concentration ratio and indoor mean-to-median ratio. Short-term spikes were associated with occupants and their activities, especially cooking. High-baseline compounds indicate continuous indoor emissions from building materials and furnishings. Indoor emission rates for high-baseline species, quantified with 2-hour resolution, exhibited strong temperature dependence and were affected by air-change rates. Decomposition of wooden building materials is suggested as a major source for acetic acid, formic acid, and methanol, which together accounted for ~75% of the total continuous indoor emissions of high-baseline species.

54 ENVIRONMENTAL SCIENCES↗