Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

NASA Ames Unitary Plan Wind Tunnel: Infrared Flow Visualization

Infra-red thermography can visualize surface flow features including boundary layer transition, shock impingement, streamwise vortex impingement, flow separation, and buffet. The Infra-red thermography system at the NASA ARC Unitary Plan Wind Tunnel allows for continuous monitoring of wind tunnel models with up to four cameras simultaneously. For best results the models should be covered with a high emissivity coating, and the images processed to enhance contrast. However image processing algorithms allow some flow information to be recovered even from uncoated models.

Garbeff, Ted↗

Development of Unsteady Pressure-Sensitive Paint Application on NASA Space Launch System

The key measurement to acquire for understanding unsteady flow is surface pressure. Unsteady Pressure-Sensitive Paint (uPSP) is an emerging optical technique used in wind tunnel testing to measure fluctuating surface pressures. Recently, tests were conducted on NASA’s Space Launch System in NASA Ames Research Center’s Unitary Plan Wind Tunnel to determine the aeroacoustics environment and assist in developing the buffet forcing functions. Unsteady PSP data was collected during this test campaign. Steady state PSP data, infrared thermography, shadowgraph, accelerometer data, and dynamic pressure transducer data were also collected. In all 50 TB of data were collected during the three days of testing. During these three days of testing, a repeating transonic and supersonic alpha sweep condition was acquired. This paper presents these two wind tunnel conditions and examines how the temperature influences the PSP data. In the first large demonstration of uPSP in 2015 on an NESC-, AETC-sponsored wind tunnel test, lifetime PSP results highlighted the influence the model temperature had on the PSP data. A best practice of heat soaking the model before acquiring calibration images was followed during the test campaign presented in this paper. An infrared thermography camera and thermocouples were installed in the model to collect more details of the model surface temperature. Data processing schemes for uPSP are still in development but will be briefly presented here as well.

Roozeboom, Nettie H.↗

Automatic Incorporation of Flaws into Cad and FEA Models Based On Measured NDE Data

Automatic incorporation of non-destructive evaluation (NDE) data into CAD and finite element (FE) models for structural analysis is essential for accurate residual-life and strength analyses of composite structures. Currently, two significant but independent challenges exist for incorporating NDE data in such analyses: interpretation of the NDE signals to locate and characterize the structural defects and the incorporation of that information into structural analysis tools. The first challenge will be addressed through linear inversion of calculated synthetic responses generated by a simulation engine to evaluate flaw size, location, and other characteristics. The second challenge will be addressed by building on prior and parallel defect modeling efforts to integrate suitable flaw models into the CAD/finite-element representation of a specimen. Ultrasonic NDE information is usually represented using C-Scans of time-of-flight or intensity information. Other modalities such as thermography and computed tomography (CT) could also be used to characterize the structure. This information will first be projected into material coordinates and then aligned with the specimen’s finite element mesh. The NDE data can then be incorporated by inserting flaw geometry into the CAD and FE analysis model and automatic modification of local material properties and boundary conditions. This process will enable the use of structural analysis tools even for practical modalities such as ultrasound and thermography which may not directly give accurate-enough geometric information to fully define the flaw. The full flaw characteristics will be inferred using prior expert and modeling knowledge to categorize flaw signatures. Outputs for this project will include demonstrated methods for creating structural analysis geometric models that incorporate flaw characterization information; these models can then be used directly in popular commercial FEA software. In addition, the primary deliverable for the project will include a software that will be able to automatically incorporate different kinds of flaws into an existing FE models. The models will be generated in standard file formats to enable direct import into the analysis software.

Adarsh Krishnamurthy↗

NASA Langley Aerothermodynamic Ground Tests in Support of the Boundary Layer Transition (BOLT) Flight Experiment

The Air Force Office of Scientific Research (AFOSR) has sponsored the Boundary Layer Transition (BOLT) Experiments to investigate hypersonic boundary layer transition on a low-curvature, concave surface with swept leading edges. This paper provides a review of aerothermodynamic ground test contributions by NASA Langley Research Center to the design of the BOLT flight experiment. Several test entries into the Langley Aerothermodynamics Laboratory 20-Inch Mach 6 Air Tunnel are discussed. Global surface heating distributions on subscale BOLT models were measured using either phosphor thermography or infrared thermography at a range of model attitudes and freestream Reynolds numbers. An initial test entry provided the first experimental measurements of transition on the BOLT geometry. A second test entry investigated the effects of distributed surface roughness along the swept leading edges. A third test entry provided an evaluation of the aeroheating environment on the aerodynamic fairings and a portion of the flight vehicle downstream of the BOLT experiment. These entries were intended to support the development and design of flight hardware and instrumentation for the BOLT flight experiment.

Elizabeth F Rieken↗

Aftbody Aeroheating Wind Tunnel Measurements on a Hypersonic Inflatable Aerodynamic Decelerator

The aftbody aeroheating environment of a Hypersonic Inflatable Aerodynamic Decelerator (HIAD) was investigated in the NASA Langley 31-Inch Mach 10 Air Tunnel. The wind tunnel model geometry was representative of the Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) vehicle. Aeroheating data were obtained for a range of Reynolds numbers and angles-of-attack using global phosphor thermography. Aeroheating data were also obtained using a developmental IR thermography technique for evaluation of data quality.

Elizabeth F Rieken↗

Thermal Inspection of a Composite Fuselage Section Using theMethod of Proper Generalized Decomposition

Proper Generalized Decomposition (PGD) is a reduced order modeling technique for the simulation of physical systems whose governing equations depend on boundary conditions, initial conditions, material properties, and geometric parameters. It uses separated representations of system covariates combined with an iterative approximation method known as successive enrichment in order to compute an accurate parameter-dependent approximation to the full governing equations. PGD can also be used as an alternative to the Singular Value Decomposition (SVD) of a matrix and therefore as an alternative to PCA thermography. In this paper PGD was used to analyze data derived from the inspection of a composite fuselage forward section using flash thermography, and the results were compared against the standard PCA approach.

Nondestructive Evaluation↗

Separation and Transition on the ROTEX-T Cone-Flare

As part of NATO STO AVT-346 “Predicting Hypersonic Boundary-Layer Transition on Complex Geometries,” coordinated experimental and computational studies were conducted on the ROTEX-T, a cone-flare geometry used in a successful flight-test experiment. At the as-flown conditions, a separation bubble existed at the compression corner. Separation, reattachment, and the multifaceted linear instability paths leading this bubble to transition to turbulence are challenging to predict, but have significant impact on surface pressure and heat flux. High-resolution background-oriented schlieren and infrared thermography measurements were made in the AFOSR–Notre Dame Large Mach-6 Quiet Tunnel at freestream unit Reynolds numbers from 5.8×10(exp 6) to 12.2×10(exp 6) m-1and nominally zero angle of attack. High-speed self-aligned focusing schlieren, infrared thermography, and focused laser differential interferometry measurements were made in the AFRL Mach-6 Ludwieg Tube from 2.2×10(exp 6) to 24.7×10(exp 6) m-1and nominally zero degrees angle of attack. The surface heat-flux and Stanton number distributions were computed. Separation and reattachment locations, as well as the flow state at each, were determined from the combination of surface and off-wall measurements. The convective and global boundary-layer instabilities of the axisymmetric laminar flow at the experimental conditions were investigated computationally. Amplification of Mack’s first and second modes were observed to have logarithmic amplification factors between 5 to 7.5 at the separation location, depending on conditions. The flow was found to be globally unstable to stationary three-dimensional disturbances concentrated in the reattachment region. Previous analysis of the ROTEX-T flight data had not assessed reattachment location or the flow state upon reattachment. Thanks to the insights gained from the coordinated, on- and off-wall ground-test measurements, these evaluations have now been made. The separation location indicated by laminar simulations is consistently numerically predicted to be upstream of the experimentally observed location for a transitional separation bubble. The cause of this difference is understood to lie in the steady-state and axisymmetric assumptions made by both solvers employed to compute the basic states analyzed, as flow topology considerations assert that unsteady two-dimensional or axisymmetric separation bubbles are structurally unstable and will become three-dimensional. Computed laminar heating rates prior to separation agreed well with experiment; transitional heating rates after reattachment were between laminar and turbulent computations.

CFD Validation↗

Separation and Transition on the ROTEX-T Cone-Flare

As part of NATO STO AVT-346 “Predicting Hypersonic Boundary-Layer Transition on Complex Geometries,” coordinated experimental and computational studies were conducted on the ROTEX-T, a cone-flare geometry used in a successful flight-test experiment. At the as-flown conditions, a separation bubble existed at the compression corner. Separation, reattachment, and the multifaceted linear instability paths leading this bubble to transition to turbulence are challenging to predict, but have significant impact on surface pressure and heat flux. High-resolution background-oriented schlieren and infrared thermography measurements were made in the AFOSR–Notre Dame Large Mach-6 Quiet Tunnel at freestream unit Reynolds numbers from 5.8×10(exp 6) to 12.2×10(exp 6) m-1and nominally zero angle of attack. High-speed self-aligned focusing schlieren, infrared thermography, and focused laser differential interferometry measurements were made in the AFRL Mach-6 Ludwieg Tube from 2.2×10(exp 6) to 24.7×10(exp 6) m-1and nominally zero degrees angle of attack. The surface heat-flux and Stanton number distributions were computed. Separation and reattachment locations, as well as the flow state at each, were determined from the combination of surface and off-wall measurements. The convective and global boundary-layer instabilities of the axisymmetric laminar flow at the experimental conditions were investigated computationally. Amplification of Mack’s first and second modes were observed to have logarithmic amplification factors between 5 to 7.5 at the separation location, depending on conditions. The flow was found to be globally unstable to stationary three-dimensional disturbances concentrated in the reattachment region. Previous analysis of the ROTEX-T flight data had not assessed reattachment location or the flow state upon reattachment. Thanks to the insights gained from the coordinated, on- and off-wall ground-test measurements, these evaluations have now been made. The separation location indicated by laminar simulations is consistently numerically predicted to be upstream of the experimentally observed location for a transitional separation bubble. The cause of this difference is understood to lie in the steady-state and axisymmetric assumptions made by both solvers employed to compute the basic states analyzed, as flow topology considerations assert that unsteady two-dimensional or axisymmetric separation bubbles are structurally unstable and will become three-dimensional. Computed laminar heating rates prior to separation agreed well with experiment; transitional heating rates after reattachment were between laminar and turbulent computations.

CFD Validation↗

Bond Line Thickness Estimation in Composite Structures Using Multiple Inspection Techniques

Imaging and other nondestructive evaluation techniques are commonly used for material characterization and defect recognition in safety critical aerospace applications, with data fusion providing the framework for uncertainty quantification in these contexts. Most commonly, forward physics-based modeling predicts the response conditioned on material properties and defect assumptions, and probabilistic methods are used to infer the hidden state of the subject of the inspection from a combination of prior information, likelihoods, and inspection data. In this paper Bayesian methods are used to estimate bond thickness in lap joints comprised of aluminum adherends using a combination of infrared thermography and ultrasound. The concept of the conflation of probability distributions is applied to combine the posterior distributions derived from thermography and ultrasound and the quality of the fused estimates are compared against the individual estimates against synthetic data that was created to mimic the inspection of a lap joint comprised of aluminum adherends.

thermal nondestructive evaluation↗

Thermographic phosphor digital image correlation

The invention advances the ratio method of phosphor thermography using two machine vision cameras for full-field temperature measurements of a solid surface. As an example, algorithms from digital image correlation (DIC) can be used to determine the stereoscopic imaging system intrinsic and extrinsic parameters, and accurately register material points on the sample to subpixel locations in each image with 0.07 px or better accuracy. A phosphor calibration sample fabricated using aerosol deposition can be used for in situ determination of the temperature-versus-intensity ratio relationship. The full calibration methodology and several improvements on two-color phosphor thermography open the door for full-field temperature measurements in dynamic tests with deforming test specimens. In particular, thermographic phosphors can be combined with stereo digital image correlation in a novel diagnostic, TP+DIC, to measure time-resolved full-field surface strains and temperatures simultaneously, thereby enabling testing in combined thermo-mechanical environments.

Winters, Caroline↗

Heat loads from ICRF and LH wave absorption in the SOL: characterization on JET and implications for the ITER-Like Wall

Heat loads from ICRF and LH wave absorption in the SOL are characterized on JET from the de-convolution of surface temperatures measured by infrared thermography. The spatial localization, quantitative estimates, parametric dependence and physical origin of the observed heat fluxes are documented. Implications of these observations are discussed for the operation of JET with an ITER-Like Wall, featuring Beryllium tiles with reduced power handling capability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accelerated Stress Testing of Perovskite Photovoltaic Modules: Differentiating Degradation Modes with Electroluminescence Imaging

Herein, electroluminescence (EL) and thermal imaging are used to examine p–i–n metal halide perovskite (MHP) photovoltaic (PV) mini-modules (MA0.6FA0.4PbI3, 20 cells, 78 cm2) before and after indoor-accelerated stress testing or outdoor deployment. Distinct spatial patterns in the EL images emerge, which depend on the external stress conditions experienced by the mini-module. Imaging results highlight a distribution of dark speckle features that dominate after UV stress, attributed to widespread interfacial contact degradation. Lateral intensity gradients across cells dominate after thermal cycling (TC) stress, attributed to current crowding near scribe defects. While current–voltage analysis alone does not give full insight on the degradation process, this study shows that distinct degradation modes can be further defined by multimodal electro-optical imaging (i.e., EL combined with photoluminescence and dark lock-in thermography). Neither UV exposure nor TC-accelerated stress testing alone replicates the same degradation signatures observed after outdoor deployment, suggesting that multiple degradation modes occur under concurrent stressors outdoors. Finally, spatial characterization of degradation modes in MHP PV mini-modules before and after accelerated stress testing lays the groundwork for developing targeted accelerated stress testing procedures through comparison with outdoor aging.

14 SOLAR ENERGY↗

Temperature evolution on Rh/Al{sub 2}O{sub 3} catalyst during partial oxidation of methane in a reverse flow reactor

Catalytic partial oxidation of methane was investigated in a reverse flow reactor with commercial Rh/Al{sub 2}O{sub 3} catalyst in pellets. The process is carried out in a catalytic fixed bed reactor and switching of feed flow direction is obtained through four electrovalves synchronized in pairs. Temperature profile along the catalyst bed was measured by fast IR thermography and product composition was measured with a continuous gas analyzer. Feed direction switching time, water to methane ratio and inert section length were investigated as process parameters. Data of catalyst bed temperature evolution during the flow cycle are presented, discussed and related to reactor performance as a function of reverse flow switching period. The effect of water addition to the reacting mixture on the dynamics of catalyst bed temperature evolution is also presented. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-situ thermal analysis of intermetallic and thermite projectiles in high velocity impact experiments

Particle fragmentation influences thermochemical energy conversion processes in different ways and is of significance in energy generation technologies. Different reactive material formulations trigger varied thermal response in extreme environments such as high velocity impact. Here we investigated optical thermal response of powder gun launched intermetallic (Al:Zr) and thermite (Al:MoO 3 ) projectiles using pyrometry and thermography. Projectiles were launched at 1250 m/s into an air-filled chamber and impacted a steel witness plate to create a dust explosion. The pyrometer was configured to measure temperatures directly at the point of impact, while the thermographic system measured temperatures throughout the explosion chamber. Results show that impact temperatures ranged between 3500 and 4000 K, but that the dynamics of energy conversion were different for the intermetallic and thermite projectiles. The intermetallic exhibited secondary reactions due to fragmented debris impacting the walls of the chamber. The thermite exhibited greater gas generation, propelling the debris field, and producing a more stochastic response with faster spreading and dissipation of thermal energy. Unique features such as microexplosions within fragmented particles were also analyzed. While both reactive materials produce similar temperatures, their mechanisms of energy conversion and release are different, indicating the potential of these materials for different ballistic applications.

42 ENGINEERING↗

Local convection characteristics of inline arrangement of Kagome-shaped unit cells in a square duct

Transient liquid crystal thermography experiments have been conducted to determine detailed convective heat transfer coefficients at the endwalls of lattice-frame configurations based on Kagome-shaped unit cells. Kagome unit cells with porosity of 0.88 were arranged in an inline manner, where two such arrangements were studied. In the first arrangement, a total of ten unit cells were placed next to each other along the streamwise direction resulting in a continuous configuration. In the 2nd arrangement, alternate unit cells from the continuous configuration were dropped, resulting in a discrete configuration which featured a total of 5 Kagome unit cells. Due to the asymmetric nature of the strut connections within the unit cell, the convective heat transfer coefficient maps were determined for the two opposite walls where the struts meet the endwalls. Transient liquid crystal experiments were conducted for Reynolds number ranging between 10,000 and 30,000. Here, the study was focused on the developing nature of flow along the streamwise direction and the local convection characteristics for continuous and discrete arrangement of unit cells. For the continuous configuration, the Nusselt number ratios (N u /Nu 0 ) varied between 3.15–3.46 and 2.75–2.89 for the two walls A and B, respectively. For the discrete configuration, convective heat transfer coefficients varied between 2.56–2.71 and 2.09–2.40 for the two walls. Kagome unit cells have the potential to be fabricated through inexpensive manufacturing routes such as wire-woven method and these unit cells find their applications in the areas which require different heat transfer levels on opposite walls.

Kagome↗

“The development of a through-plane reactive excitation technique for detection of pinholes in membrane-containing MEA sub-assemblies”

As markets for polymer-electrolyte-membrane fuel cells (PEMFC) expand, there continues to be a need for the development and implementation of in-line quality inspection techniques to enable high-volume manufacturing methods for membrane-electrode assemblies (MEAs). These techniques mitigate the potential impact of poor quality on the cost of MEA components by real-time identification of process-induced irregularities, which can result from the manufacturing process or subsequent handling of the material during assembly into a full MEA. A particular type of irregularity known to impact MEA lifetime is loss of membrane integrity, e.g. via a pinhole. In this work, we focus on development of a technique to detect pinholes in membrane-containing MEA sub-assemblies - as opposed to in just the membrane - using a reactive excitation strategy coupled with infrared thermography for detection. A specialized device is introduced and, using various MEA sub-assemblies, is shown to enable detection of pinholes in stationary samples. Multi-physics modeling is utilized to understand and predict the impact of various design and operational parameters of this technique. The feasibility of the technique is demonstrated through both modeling and in-situ results. For example, a detectable (≥1 degree C) thermal response for a membrane pinhole of approximately 90 um in diameter is measured in a fraction of a second. The observed detection time is considered to be appropriate for further exploration of the technique in an in-line configuration.

30 DIRECT ENERGY CONVERSION↗

Dependence of divertor heat flux widths on heating power, flux expansion, and plasma current in the NSTX

Here, we report the dependence of the lower divertor surface heat flux profiles, measured from infrared thermography and mapped magnetically to the mid-plane on loss power into the scrape-off layer (P LOSS ), plasma current (I p ), and magnetic flux expansion (f exp ), as well as initial results with lithium wall conditioning in NSTX. Here we extend previous studies to higher triangularity ~0.7 and higher I p ≤ 1.2 MA. First we note that the mid-plane heat flux width mapped to the mid-plane, $λ^{mid}_q$, is largely independent of P LOSS for P LOSS ≥ 4 MW. $λ^{mid}_q$ is also found to be relatively independent of f exp ; peak heat flux is strongly reduced as f exp is increased, as expected. Finally, $λ^{mid}_q$ is shown to strongly contract with increasing I p such that $λ^{mid}_q$ ∝ I$^{-1.6}_p$ with a peak divertor heat flux of q div, peak ~ 15 MW/m 2 when I p = 1.2 MA and P LOSS ~ 6 MW. These relationships are then used to predict the divertor heat flux for the planned NSTX-Upgrade, with heating power between 10 and 15 MW, B t = 1.0 T and I p = 2.0 MA for 5 s.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatially resolved phase transformation mapping in 410 stainless steel during additive manufacturing visualized via real-time infrared data

Here, in this study, we demonstrate that spatially resolved cooling curves derived from real-time infrared (IR) thermography during additive manufacturing (AM) can capture spatial variations in phase transformation temperatures through cooling curve analysis (CCA). Using this approach, we show that during laser hot-wire deposition of 410 stainless steel (410SS), the martensite start temperature (M s ) evolves dynamically throughout the build. The M s temperature is spatially nonuniform, ranging from 185 °C to 348 °C, with the lowest values toward the build center and higher values toward the upper region of the deposit. In the lower portion of the build, no M s inflection is detected via CCA, consistent with transformation occurring earlier during thermal cycling followed by tempering during subsequent thermal cycles. These trends in M s are corroborated by characterizing the microstructure by electron backscatter diffraction (EBSD). Traditionally, M s is assumed to be constant, and a single interpass temperature is applied during both deposition and residual stress modeling. Our results demonstrate that IR-derived cooling curves provide a route to spatially and temporally resolved transformation temperature tracking for dynamic interpass control and improved residual-stress modeling.

Additive manufacturing↗