Test methods for image-based information in next-generation manufacturing

Typical control designs in the process systems engineering literature have assumed that the primary sensing methodologies are traditional instruments such as thermocouples. Digitalization is changing the landscape for manufacturing, and data-based sensing modalities (e.g., image-based sensing) are becoming of greater interest for plant control. These considerations require novel test/evaluation solutions. For example, process systems engineering researchers may wish to test image-based sensors in simulation. In this work, we provide preliminary thoughts on how image-based technologies might be evaluated via simulation for process systems.

Henrique Oyama↗

Test Methods and Protocols for Environmental and Safety Hazards Associated with Home Energy Retrofits

A number of health hazards and hazards to the durability of homes may be associated with energy retrofitting and home renovation projects. Among the hazards associated with energy retrofit work, exposure to radon is thought to cause more than 15,000 deaths per year in the U.S., while carbon monoxide poisoning results in about 20,000 injuries and 450 deaths per year. Testing procedures have beendeveloped for identifying and quantifying hazards during retrofitting. These procedures commonly include a battery of tests to screen combustion appliances for safe operation, including worst case depressurization measurement, backdrafting (spillage) under depressurized or normal conditions, and carbon monoxide production.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Test Methods and Protocols for Environmental and Safety Hazards Associated with Home Energy Retrofits

A number of health hazards and hazards to the durability of homes may be associated with energy retrofitting and home renovation projects. Among the hazards associated with energy retrofit work, exposure to radon is thought to cause more than 15,000 deaths per year in the U.S., while carbon monoxide poisoning results in about 20,000 injuries and 450 deaths per year. Testing procedures have been developed for identifying and quantifying hazards during retrofitting. These procedures commonly include a battery of tests to screen combustion appliances for safe operation, including worst case depressurization measurement, backdrafting (spillage) under depressurized or normal conditions, and carbon monoxide production.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtex-II Pro SEE Test Methods and Results

The Xilinx Virtex-II Pro is a platform FPGA that embeds multiple microprocessors within the fabric of an SRAM-based reprogrammable FPGA. The variety and quantity of resources provided by this family of devices make them very attractive for spaceflight applications. However, these devices will be susceptible to single event effects (SEE), which must be mitigated. To use the Virtex-II Pro reliably in space applications, these devices must first be tested to determine if they are susceptible to single event latchup (SEL), the degree to which they are susceptible to single event upsets (SEU) and single event transients (SET), and how these effects are manifested in the device. With this information, mitigations schemes can be developed and tested that address the specific susceptiblities of these devices. This initial SEE test uses a commercial off the shelf Virtex-II Pro evaluation board, with a single processor XC2VP7 FPGA. The FPGA on this board is an acid etched device, which can be partially covered with a shield. The shield covers a portion of the logic, routing, and memory resources along with some of the RocketIO transceivers. The processor, along with a large portion of logic, routing, memory, and transceivers are left exposed. This test will be performed at the Cyclotron Laboratories at Texas A&M University and Michigan State University using ions of varying energy levels and fluencies.

Petrick, David↗

HOT SPIN-AND-BURST TEST METHODS FOR AIRCRAFT TURBINE WHEELS

Methods are described for suspension-system vibration damping, automatically controlled induction heating through radiation pyrometers, rotating-disk temperature measurement, and unattended operation with a safety-interlock system.

BURST↗

ASTM and VAMAS activities in titanium matrix composites test methods development

Titanium matrix composites (TMC's) are being considered for a number of aerospace applications ranging from high performance engine components to airframe structures in areas that require high stiffness to weight ratios at temperatures up to 400 C. TMC's exhibit unique mechanical behavior due to fiber-matrix interface failures, matrix cracks bridged by fibers, thermo-viscoplastic behavior of the matrix at elevated temperatures, and the development of significant thermal residual stresses in the composite due to fabrication. Standard testing methodology must be developed to reflect the uniqueness of this type of material systems. The purpose of this paper is to review the current activities in ASTM and Versailles Project on Advanced Materials and Standards (VAMAS) that are directed toward the development of standard test methodology for titanium matrix composites.

Johnson, W. S.↗

Binomial Test Method for Determining Probability of Detection Capability for Fracture Critical Applications

The capability of an inspection system is established by applications of various methodologies to determine the probability of detection (POD). One accepted metric of an adequate inspection system is that for a minimum flaw size and all greater flaw sizes, there is 0.90 probability of detection with 95% confidence (90/95 POD). Directed design of experiments for probability of detection (DOEPOD) has been developed to provide an efficient and accurate methodology that yields estimates of POD and confidence bounds for both Hit-Miss or signal amplitude testing, where signal amplitudes are reduced to Hit-Miss by using a signal threshold Directed DOEPOD uses a nonparametric approach for the analysis or inspection data that does require any assumptions about the particular functional form of a POD function. The DOEPOD procedure identifies, for a given sample set whether or not the minimum requirement of 0.90 probability of detection with 95% confidence is demonstrated for a minimum flaw size and for all greater flaw sizes (90/95 POD). The DOEPOD procedures are sequentially executed in order to minimize the number of samples needed to demonstrate that there is a 90/95 POD lower confidence bound at a given flaw size and that the POD is monotonic for flaw sizes exceeding that 90/95 POD flaw size. The conservativeness of the DOEPOD methodology results is discussed. Validated guidelines for binomial estimation of POD for fracture critical inspection are established.

Generazio, Edward R.↗

Impact of Testing Method on Safety Assessment of Aged Li-Ion Cells: Part II – Aged Cells Without Li Plating

Understanding the safety profile of aged Li-ion batteries is essential for developing effective battery management and hazard mitigation strategies. However, most safety assessments have focused on fresh batteries, with just a few calorimetry studies on aged batteries with metal oxide positive electrodes. This study provides a broad assessment of commercial 18650-type Li-ion batteries with NCA, NMC, and LFP positive electrodes, both uncycled and aged under conditions that promoted solid electrolyte interphase (SEI) growth as the dominant degradation mechanism. The cells underwent mechanical (nail penetration, crush), electrical (overcharge, overdischarge), and thermal (accelerating rate calorimetry) abuse tests. Safety was rated on general characteristics such as mass loss, maximum temperature, and EUCAR (European Council for Automotive R&D) hazard level, as well as characteristics specific to individual abuse tests. Generally, aged cells with SEI growth exhibited similar or improved safety compared to uncycled cells, contrasting with our previous findings on NCA cells with Li plating as the dominant aging mechanism (Part I of this series). Yet, some tests and characteristics indicated reduced aged cell safety, such as earlier triggering of mechanical failure. These results emphasize the need to examine aged battery safety across diverse empirical techniques, degradation modes, and chemistries.

Lithium-ion cells↗

Modern Methods of Testing

After a brief survey of the commonly used single-value test methods, the importance of the determination of the incipient knock for the octane number is discussed and improvements suggested for the knock testing in the CFR engine. The DVL supercharge test method with its superiority of direct determination of fuel knock in each single cylinder of an airplane engine without involving structural changes, is described and the advantages of a multiple-value method enumerated. A diagrammatic presentation of the knock characteristics is presented.

Seeber, F↗

A flight test method for pilot/aircraft analysis

In high precision flight maneuvres a pilot is a part of a closed loop pilot/aircraft system. The assessment of the flying qualities is highly dependent on the closed loop characteristics related to precision maneuvres like approach, landing, air-to-air tracking, air-to-ground tracking, close formation flying and air-to air refueling of the receiver. The object of a research program at DFVLR is the final flight phase of an air to ground mission. In this flight phase the pilot has to align the aircraft with the target, correct small deviations from the target direction and keep the target in his sights for a specific time period. To investigate the dynamic behavior of the pilot-aircraft system a special ground attack flight test technique with a prolonged tracking maneuvres was developed. By changing the targets during the attack the pilot is forced to react continously on aiming errors in his sights. Thus the closed loop pilot/aircraft system is excited over a wide frequency range of interest, the pilot gets more information about mission oriented aircraft dynamics and suitable flight test data for a pilot/aircraft analysis can be generated.

Koehler, R.↗

Statistical fracture behavior of doped UO 2 using a ball-on-ring equibiaxial flexure test method

Metal oxide dopants, such as titanium and chromium oxides, have garnered considerable attention for their potential to increase grain size (≥ 30 µm) in UO 2 fuel, purportedly enhancing fission gas retention during reactor operation. Fuel performance is significantly impacted by fuel fracture behavior, so it is important to understand the effects of enhanced grain size and dopant content on UO 2 fuel fracture. UO 2 pellets were doped with 0.1 wt% TiO 2 and 0.3 wt% Cr 2 O 3 to alter density and grain size. Inductively coupled plasma mass spectroscopy measured dopant levels pre- and post-sintering. X-ray diffraction revealed lattice changes and microstrain via Rietveld refinement. Field emission scanning electron microscopy determined grain sizes of approximately 30 µm for TiO 2 doping and 7 µm for Cr 2 O 3 doping. Transverse rupture strength tests were performed on over 30 samples per dataset to obtain characteristic strength and Weibull modulus. Results indicate no statistical difference in fracture strength between 0.1 wt% TiO 2 doped UO 2 and undoped UO 2 , while 0.3 wt% Cr 2 O 3 doped UO 2 exhibited a 20% decrease in fracture strength. Doped UO 2 samples also showed reduced Weibull modulus compared to undoped UO 2 , suggesting increased scatter in fracture strength. This study's findings suggest that titanium and chromium oxide doping in UO 2 , regardless of grain size, induce residual stresses, decreasing fracture strength and increasing variability in fracture behavior.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design Enhancement and Improved Post-Actuation Test Method for a 1/4 inch Normally Closed Pyro Valve

The NASA/JPL Cassini mission to Saturn will launch in October, 1997 and arrive at Saturn in the year 2004 with a 4 year mission to orbit the planet. The main propulsion thrust vector and attitude control for the spacecraft is supplied by the Cassini Propulsion Module Subsystem (C-PMS). This system will use numerous ordnance-actuated, normally-closed (NC) pyro valves to perform mission critical tasks over the 11 year mean mission duration (NMD). The proper operation of this NC valve requires it to isolate fluid flow until commanded open. Once open, the valve must allow an unobstructed flow path and seal internally to prevent leakage external to the valve. This paper documents a design evolution to a qualified, Viking heritage design with improvements in design details that control external leakage to levels that support the planetary mission of this spacecraft. In addition, it addresses an improved post-actuation leak test technique, used to better detect gas leakage past the valve's primary metal-to-metal internal seal.

Cassini↗

Development of Mini-Compact Tension Test Method for Determining Fracture Toughness Master Curves for Reactor Pressure Vessel Steels

Small specimens are playing the key role in evaluating properties of irradiated materials. The use of small specimens provides several advantages. Typically, only a small volume of material can be irradiated in a reactor at desirable conditions in terms of temperature, neutron flux, and neutron dose. A small volume of irradiated material may also allow for easier handling of specimens. Smaller specimens reduce the amount of radioactive material, minimizing personnel exposures and waste disposal. However, use of small specimens imposes a variety of challenges as well. These challenges are associated with proper accounting for size effects and transferability of small specimen data to the real structures of interest. Any fracture toughness specimen that can be made out of the broken halves of standard Charpy specimens may have exceptional utility for evaluation of reactor pressure vessels (RPVs) since it would allow one to determine and monitor directly actual fracture toughness instead of requiring indirect predictions using correlations established with impact data. The Charpy V-notch specimen is the most commonly used specimen geometry in surveillance programs. Validation of the mini compact tension specimen (mini-CT) geometry has been performed on previously well characterized Midland beltline Linde 80 (WF-70) weld in the unirradiated condition. It was shown that the fracture toughness transition temperature, To, measured by these Mini-CT specimens is almost the same as To value that was derived from various larger fracture toughness specimens. Moreover, an International collaborative program has been established to extend the assessment and validation efforts to irradiated Linde 80 weld metal. The program is underway and involves the Oak Ridge National Laboratory (ORNL), Central Research Institute for Electrical Power Industry (CRIEPI), and Electric Power Research Institute (EPRI). The irradiated Mini-CT specimens from broken halves of previously tested Charpy specimens of Midland beltline weld have been machined and just arrived to ORNL as part of this international collaboration. The ORNL will initiate tests of the irradiated Linde 80 weld in FY2017 and results of this international program will be reported in FY2018.

42 ENGINEERING↗

Splat Quenching as a High Throughput Rapid Solidification Testing Method for Developing Additive Manufacturing Alloys

Splat quenching as a high throughput rapid solidification screening tool is evaluated. Samples were made using known alloys (SS316, IN625, Ti-5553) to evaluate and establish the microstructures for a variety of alloy systems as well as the predicted cooling rates. The samples are inductively heated and levitated prior to being struck between two platens that produce a high contact pressure and a thin sample resulting in cooling rates on the order of 10 6 to 10 7 K/s. Process parameters were evaluated with analytical models in addition to numerical simulations to provide an effect of process variables such as substrate material, melt superheat, and platen velocity on the resulting solidification. The splat thickness was found to be controlled by platen velocity, melt superheat, as well as the feedstock volume. The sample thickness is the key controlling factor for varying the average cooling rate experienced by the splat quenched sample. The splat quenching techniques can reach regions of rapid solidification space that meet and exceed laser and electron beam techniques across the sample. In conclusion, the results of the study provide a useful foundation in understanding the splat quenching technique and its potential as a low effort tool to explore rapid solidification effects on alloys.

Alloy Design↗

The continuing evolution of torsades de pointes liability testing methods: Is there an end in sight?

Drug-induced torsades de pointes (TdP) is a syndrome that includes a potentially lethal cardiac arrhythmia. It has been identified as a possible adverse drug reaction (ADR) for drugs which affect the repolarization processes of the heart. In order to predict the potential for TdP liability, regulatory guidelines have been developed which require that new drugs be safety screened. Unfortunately, however, despite this requirement there are no validated preclinical models with TdP incidence as a hard endpoint. Therefore, surrogate biomarkers are used. The most common and eliciting the most discussion/controversy among cardiovascular scientists is the duration of the QT interval of the ECG. Since no single model is available to wholly assess drug-induced TdP liability, safety pharmacologists employ a battery of complementary preclinical models in order to develop an integrated risk assessment (IRA). Ideally, the IRA should be comprised of the results from the effects of the new chemical entity (NCE) on the human ether-a-go-go related (hERG) gene assay (actually a screen for block of the hERG gene product, the inward rectifying K current, IKr) and ECG effects in the conscious canine. However, since neither model is ideal the findings are generally supplemented by conduct of several additional experimental in vitro assays, namely the rabbit left ventricular wedge preparation, Langendorff isolated rabbit heart or isolated canine Purkinje fibre; nevertheless, as with many preclinical models, there is only limited validation and a resultant lack of general acceptance. Institution of regulatory guidance documents such as ICH S7A and S7B in conjunction with heightened awareness of the electrophysiological mechanisms that may be responsible for the development of TdP has led to a sharp fall in proarrhythmic compounds securing licensing, but at what costs? Supplementary experimental assays have furthered our understanding of drug-induced torsadogenesis, and it is now recognized that TdP is a multicausal event. This means that a perceived 'positive' torsadogenic risk using one of the aforementioned models does not necessarily guarantee proarrhythmia. There has been an overall fall in the total number of NCEs pursued through development due to strict regulatory guidelines. Here we suggest that regulatory barriers can be alleviated by improving the integrated risk approach. But this requires better validation and deployment of existing preclinical models together with the invention of more precise and accurate models.

60 APPLIED LIFE SCIENCES↗