Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEMPERATURE PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

The behavior of the plasmapause at mid-latitudes - Isis 1 Langmuir probe measurements

Observations of the electron concentration and the temperature from the electrostatic probes on the Isis 1 satellite were used to examine the location and behavior of the plasmapause at about 3000-km altitude in the vicinity of L = 4. At these altitudes the electron concentration measurements are equivalent to measurements of H(+), since the satellite is well into the protonosphere. The plasmapause is evident as a sharp drop in electron concentration by a factor of 100 as the satellite passes into the polar cap, and a corresponding increase is observed as it enters the plasmasphere on the opposite side of the earth. An enhancement of temperature is also observed at the plasmapause, an effect that is most visible at night, when the temperatures at latitudes above and below the plasmapause are usually very low. The position of the plasmapause decreases with magnetic activity but is found to be somewhat less sensitive to Kp than is the equatorial plasmapause.

Brace, L. H.↗

Air Data Probe Anomalies in Flight through Measured High Ice Water Content Conditions

High concentrations of ice crystals in convective storms have caused anomalous air temperature and airspeed readings during commercial and research flight operations. These anomalies occur when ice crystals are ingested in the heated probe inlet, melt or partially melt to liquid water, and then refreeze or remain in a liquid state depending on the probe heat and cloud conditions. In pitot probes, the refreezing may cause complete blockage of the total pressure, which causes airspeed anomalies. In total air temperature probes, the melted ice water may flow near the temperature sensing element and cause the total air temperature reading to approach 0 degree Celsius. During the High Ice Water Content (HIWC) RADAR and HIWC-2022 flight campaigns and the Convective Process Experiment (CPEX-CV) flight campaign, a total of 71 anomalies were recorded on the NASA DC-8 pitot probes when subjected to specific flight and cloud conditions. Similarly, a research TAT probe mounted near the pitot probes had 19 anomalies. This paper presents analyses of the measured natural conditions that led to these TAT and pitot anomalies, identifies two types of pitot probe anomalies, applies a concentration factor to estimate local TWC conditions near the TAT and pitot probes, and identifies the static air temperature and pressure altitude where the anomalies occurred on the Part 33 Appendix D envelope.

Aircraft Icing↗

Air Data Probe Anomalies in Flight through Measured High Ice Water Content Conditions

High concentrations of ice crystals in convective storms have caused anomalous air temperature and airspeed readings during commercial and research flight operations. These anomalies occur when ice crystals are ingested in the heated probe inlet, melt or partially melt to liquid water, and then refreeze or remain in a liquid state depending on the probe heat and cloud conditions. In pitot probes, the refreezing may cause complete blockage of the total pressure, which causes airspeed anomalies. In total air temperature probes, the melted ice water may flow near the temperature sensing element and cause the total air temperature reading to approach 0 degree Celsius. During the High Ice Water Content (HIWC) RADAR and HIWC-2022 flight campaigns and the Convective Process Experiment (CPEX-CV) flight campaign, a total of 71 anomalies were recorded on the NASA DC-8 pitot probes when subjected to specific flight and cloud conditions. Similarly, a research TAT probe mounted near the pitot probes had 19 anomalies. This paper presents analyses of the measured natural conditions that led to these TAT and pitot anomalies, identifies two types of pitot probe anomalies, applies a concentration factor to estimate local TWC conditions near the TAT and pitot probes, and identifies the static air temperature and pressure altitude where the anomalies occurred on the Part 33 Appendix D envelope.

Aircraft Icing↗

Spatial Variations in Titan's Atmospheric Temperature: ALMA and Cassini Comparisons from 2012 to 2015

Submillimeter emission lines of carbon monoxide (CO) in Titan's atmosphere provide excellent probes of atmospheric temperature due to the molecule's long chemical lifetime and stable, well constrained volume mixing ratio. Here we present the analysis of 4 datasets obtained with the Atacama Large Millimeter/Submillimeter Array (ALMA) in 2012, 2013, 2014, and 2015 that contain strong CO rotational transitions. Utilizing ALMA's high spatial resolution in the 2012, 2014, and 2015 observations, we extract spectra from 3 separate regions on Titan's disk using datasets with beam sizes ranging from 0.35 ×0.28'' to 0.39 ×0.34''. Temperature profiles retrieved by the NEMESIS radiative transfer code are compared to Cassini Composite Infrared Spectrometer (CIRS) and radio occultation science results from similar latitude regions. Disk-averaged temperature profiles stay relatively constant from year to year, while small seasonal variations in atmospheric temperature are present from 2012 to 2015 in the stratosphere and mesosphere ( approx. 100-500 km) of spatially resolved regions. We measure the stratopause (320 km) to in- crease in temperature by 5 K in northern latitudes from 2012 to 2015, while temperatures rise throughout the stratosphere at lower latitudes. We observe generally cooler temperatures in the lower stratosphere ( approx. 100 km) than those obtained through Cassini radio occultation measurements, with the notable exception of warming in the northern latitudes and the absence of previous instabilities; both of these results are indicators that Titan's lower atmosphere responds to seasonal effects, particularly at higher latitudes. While retrieved temperature profiles cover a range of latitudes in these observations, deviations from CIRS nadir maps and radio occultation measurements convolved with the ALMA beam-footprint are not found to be statistically significant, and discrepancies are often found to be less than 5 K throughout the atmosphere. ALMA's excellent sensitivity in the lower stratosphere (60-300 km) provides a highly complementary dataset to contemporary CIRS and radio science observations, including altitude regions where both of those measurement sets contain large uncertainties. The demonstrated utility of CO emission lines in the submillimeter as a tracer of Titan's atmospheric temperature lays the groundwork for future studies of other molecular species -particularly those that exhibit strong polar abundance enhancements or are pressure-broadened in the lower atmosphere, as temperature profiles are found to consistently vary with latitude in all three years by up to 15 K.

Thelen, Alexander E.↗

Temperature and Flow Measurements in Incompressible Heated Jets

An experimental study is conducted to perform time-resolved temperature and velocity measurements on a Mach 0.08 jet at total temperatures of 295 K and 353 K. Mean and rms temperature data acquired using two fine wire sensors with diameters 1.3 and 3.8 μm are compared. In order to extend the limited frequency response of the wires, the temperature data are post-processed using a frequency compensation technique available in the literature. Corresponding velocity measurements are performed at cold and heated conditions using single and parallel wire probes. Simultaneously measured temperature and velocity data obtained using the parallel wire probe are used to calculate correlations pertinent to axial turbulent heat flux. In addition to shedding some light on the aerothermal properties of heated turbulent jets, vis-`a-vis their cold counterparts, this study also provides a database for numerical prediction of these flows.

Temperature measurement, turbulence, Jets, Turbule↗

Thermal Field Imaging Using Ultrasound

It is often desirable to be able to determine the temperature field in the interiors of opaque fluids forced into convection by externally imposed temperature gradients. To measure the temperature at a point in an opaque fluid in the usual fashion requires insertion of a probe, and to determine the full field therefore requires either the ability to move this probe or the introduction of multiple probes. Neither of these solutions is particularly satisfactory, although they can lead to quite accurate measurements. As an alternative we have investigated the use of ultrasound as a relatively non-intrusive probe of the temperature field in convecting opaque fluids. The temperature dependence of the sound velocity can be sufficiently great to permit a determination of the temperature from timing the traversal of an ultrasound pulse across a chamber. In this paper we will present our results on convecting flows of transparent and opaque fluids. Our experimental cells consist of relatively narrow rectangular cavities made of thermally insulating materials on the sides, and metal top and bottom plates. The ultrasound transducer is powered by a pulser/receiver, the signal output of which goes to a very high speed signal averager. The average of several hundred to several thousand signals is then sent to a computer for storage and analysis. The experimental procedure is to establish a convective flow by imposing a vertical temperature gradient on the chamber, and then to measure, at several regularly spaced locations, the transit time for an ultrasound pulse to traverse the chamber horizontally (parallel to the convecting rolls) and return to the transducer. The transit time is related to the temperature of the fluid through which the sound pulse travels. Knowing the relationship between transit time and temperature (determined in a separate experiment), we can extract the average temperature across the chamber at that location. By changing the location of the transducer it is then possible to find the average temperature at different locations along the chamber, thereby determining the temperature profile along the system. (In the future we will construct an array of transducers. This will give us the capability to determine the temperature profile much more rapidly than at present, an important consideration if time-dependent phenomena are to be studied.) To validate our procedure we introduced encapsulated liquid crystal particles into glycerol. The liquid crystal particles' color varies depending on the temperature of the fluid. A photograph of the fluid through transparent sidewalls therefore gives a picture of the temperature field of the convecting fluid, independent of our ultrasound imaging. A representative result is shown in the Figure 1, which reveals a very satisfying correspondence between the two techniques. Therefore we have a great deal of confidence that the ultrasound imaging approach is indeed measuring the actual temperature profile of the fluid. The technique has also been applied to convecting liquid metal flows, and representative data will be presented from those experiments as well.

Andereck, D.↗

Combination probe for hi-frequency unsteady aerodynamic measurements

A combination probe for time-resolved measurements of unsteady compressible flows in transonic wind tunnels is described. The probe measures stagnation (total) temperature and pressure, static pressure, and flow angles in two planes. From these, the fluctuating mass flux, Mach number, and velocity as well as their components in three directions can be deduced. The combination probe consists of a dual hot-wire aspirating temperature and pressure probe mounted piggyback with a high-frequency angle probe. The angle probe has four surface-mounted silicon pressure sensors. A scheme is described for retrieving from the four pressure signals the stagnation and static pressures, Mach number, and flow angles in two planes. The calibrations forming the base for this procedure, obtained from steady-state tests, are given. Typical data obtained in the Karman vortex street shed from a cylinder and at the exit of a Mach 0.4 air jet are presented.

Ng, W. F.↗

A combination probe for high-frequency unsteady aerodynamic measurements in transonic wind tunnels

A combination probe for time-resolved measurements for unsteady compressible flows is described. The probe measures stagnation (total) temperature and pressure, static pressure, and flow angles in two planes. From these, the fluctuating mass flux, Mach number, and velocity as well as their components in three directions can be deduced. The combination probe consists of a dual hot-wire aspirating temperature and pressure probe mounted piggyback with a high-frequency angle probe. The angle probe has four surface-mounted silicon pressure sensors. A scheme is described for retrieving from the four pressure signals the stagnation and static pressures, Mach number, and flow angles in two planes. The calibrations forming the basis for this procedure, obtained from steady-state tests, are given. Typical data obtained in the Karman vortex street shed from a cylinder and at the exit of a Mach-0.4 air jet are presented.

Ng, Wing F.↗

Wind-Tunnel and Flight Test Results for the Measurements of Flow Variables at Supersonic Speeds Using Improved Wedge and Conical Probes

The results of supersonic wind-tunnel tests on three probes at nominal Mach numbers of 1.6, 1.8 and 2.0 and flight tests on two of these probes up to a Mach number of 1.9 are described. One probe is an 8 deg. half-angle wedge with two total-pressure measurements and one static. The second, a conical probe, is a cylinder that has a 15 deg., semi-angle cone tip with one total-pressure orifice at the apex and four static-pressure orifices on the surface of the cone, 90 deg. apart, and about two-thirds of the distance from the cone apex to the base of the cone. The third is a 2 deg. semi-angle cone that has two static ports located 180 deg. apart about 1.5 inches behind the apex of the cone. The latter probe was included since it has been the "probe of choice" for wind-tunnel flow-field pressure measurements (or one similar to it) for the past half-century. The wedge and 15 deg. conical probes used in these tests were designed for flight diagnostic measurements for flight Mach numbers down to 1.35 and 1.15 respectively, and have improved capabilities over earlier probes of similar shape. The 15. conical probe also has a temperature sensor that is located inside the cylindrical part of the probe that is exposed to free-stream flow through an annulus at the apex of the cone. It enables the determination of free-stream temperature, density, speed of sound, and velocity, in addition to free-stream pressure, Mach number, angle of attack and angle of sideslip. With the time-varying velocity, acceleration can be calculated. Wind-tunnel tests of the two probes were made in NASA Langley Research Center fs Unitary Plan Wind Tunnel (UPWT) at Mach numbers of 1.6, 1.8, and 2.0. Flight tests were carried out at the NASA Dryden Flight Research Center (DFRC) on its F-15B aircraft up to Mach numbers of 1.9. The probes were attached to a fixture, referred to as the Centerline Instrumented Pylon (CLIP), under the fuselage of the aircraft. Problems controlling the velocity of the flow through the conical probe required for accurate temperature measurements are noted, as well as some calibration problems of the miniature pressure sensors that required a re-calculation of the flow variables. Data are presented for angle of attack, pressure and Mach number obtained in the wind tunnel and in flight. In the wind tunnel some transient data were obtained by translating the probes through the shock flow field created by a bump on the wind-tunnel wall.

Bobbitt, Percy J.↗

Pyrometric Gas and Surface Temperature Measurements

A multiwavelength pyrometer possessing advantages over the one- and two-wavelength designs is described. Results of its application to surface temperature measurements of ceramics is presented. Also described is a probe suitable for gas temperature measurements to temperatures > 2600 K. The design of the probe includes a multiwavelength pyrometer with fiber optic input.

Fralick, Gustave↗

Dilution jet mixing program, phase 3

The objectives of the program were: (1) to extend the data base on mixing of a single-sided row of jets with a confined crossflow, (2) to collect a data base on mixing of multiple rows of jets with confined crossflow, (3) to develop empirical jet mixing correlations, and (4) to perform limited three-dimensional calculations for some of these test configurations. The tests were performed with uniform mainstream conditions for several orifice plate configurations. Schematics of the test section and the orifice configurations are given. Temperature and pressure measurements were made in the test section at 4 axial and 11 transverse stations, using a 60-element rake probe. The measured temperature distributions for these tests are reported.

Srinivasan, R.↗

Ice Crystal Icing Investigation on a Honeywell Uncertified Research Engine in an Altitude Simulation Icing Facility

A Honeywell Uncertified Research Engine was exposed to various ice crystal conditions in the NASA Glenn Propulsion Systems Laboratory. Simulations using NASA's 1D Icing Risk Analysis tool were used to determine potential inlet conditions that could lead to ice crystal accretion along the inlet of the core flowpath and into the high pressure compressor. These conditions were simulated in the facility to develop baseline conditions. Parameters were then varied to move or change accretion characteristics. Data were acquired at altitudes varying from 5 kft to 45 kft, at nominal ice particle Median Volumetric Diameters from 20 µm to 100 µm, and total water contents of 1 g/m3 to 12 g/m3. Engine and flight parameters such as fan speed, Mach number, and inlet temperature were also varied. The engine was instrumented with total temperature and pressure probes. Static pressure taps were installed at the leading edge of the fan stator, front frame hub, the shroud of the IGV, and first two rotors. Metal temperatures were acquired for vane stators 1-2. In-situ measurements of the particle size distribution were acquired three meters upstream of the engine forward fan flange and one meter downstream of the fan in the bypass in order to study particle break-up behavior. Cameras were installed in the engine to capture ice accretions at the leading edge of the fan stator, splitter lip, and inlet guide vane. Additional measurements acquired but not discussed in this paper include: high speed pressure transducers installed at the trailing edge of the first stage rotor and light extinction probes used to acquire particle concentrations at the fan exit stator plane and at the inlet to the core and bypass. The goal of this study was to understand key parameters of accretion, acquire particle break-up data aft of the fan, and generate a unique icing dataset for model and tool development. This work described in the paper focuses on the effect of particle break-up. It was found that there was significant particle break-up downstream of the fan in the bypass especially with larger initial particle sizes. The metal temperatures on the inlet guide vanes and stators show a temperature increase with increasing MVD. Accretion behavior was very similar across all test cases. However at the inlet guide vanes, the accretion decreased with increasing particle size.

Ashlie B Flegel↗

Satellite measurements of ionic concentrations applied to low altitude incoherent scatter interpretations

The determination of ion and electron temperatures and electron density from incoherent scatter radar data has in the past involved assumptions concerning the ionospheric composition below 250 km. Using a very large data base of measurements of O(+), O2(+), NO(+), and N2(+) made by the Atmosphere Explorer C satellite, a model has been developed of the ionic concentration between 130 and 300 km as a function of solar zenith angle. As the effect of the new model is to increase the radar determinations of the temperature, this may explain previous discrepancies between Langmuir probe and incoherent scatter temperatures, where the comparisons have been made at these low altitudes

Torr, M. R.↗

Acoustic Pyrometry Applied to Gas Turbines and Jet Engines

Internal gas temperature is one of the most fundamental parameters related to engine efficiency and emissions production. The most common methods for measuring gas temperature are physical probes, such as thermocouples and thermistors, and optical methods, such as Coherent Anti Stokes Raman Spectroscopy (CARS) or Rayleigh scattering. Probes are relatively easy to use, but they are intrusive, their output must be corrected for errors due to radiation and conduction, and their upper use temperature is limited. Optical methods are nonintrusive, and they measure some intrinsic property of the gas that is directly related to its temperature (e.g., lifetime or the ratio of line strengths). However, optical methods are usually difficult to use, and optical access is not always available. Lately, acoustic techniques have been receiving some interest as a way to overcome these limitations.

Fralick, Gustave C.↗

Evidence of atmospheric gravity wave perturbations of the Brunt-Vaisala frequency in the atmosphere

A series of high altitude, medium resolution, measurements of temperature, pressure and turbulence have been performed by the Air Force Geophysics Laboratory. These measurements were conducted using the VIZ Manufacturing Co. microsondes with attached micro-thermal probes measuring the temperature structure coefficient. A typical atmospheric temperature measurement is given. Several small temperature inversions are evident in the troposphere. The stratosphere is marked with numerous fluctuations in the temperature profile. Microsondes provide temperature and pressure measurements every 4 seconds up to a maximum altitude of 30 km (MSL). Since the average ascent rate is 5 m/s, the altitude interval between the measurement reports is 20 m. The potential temperature is calculated from the temperature and pressure. Spectral analysis of atmospheric Brunt-Vaisala frequencies reveal spectra similiar to the velocity spectra of Dewan et al. (1984), Daniels (1982), and Endlich and Singleton (1969). The Brunt-Vaisala spectra indicate the existence of separate, distinguishable wave modes.

Good, R. E.↗

Hot-Wire Probe for Compressible Subsonic Flow

Probe measures velocity, density, and total temperature fluctuations. Three-wire probe used with each wire operating at different overheat ratio. Technique extendable into transonic and low supersonic flow regimes without difficulty except for those problems usually associated with lengthy calibration and possible wire breaking.

Stainback, P. C.↗

Electron and ion temperatures - A comparison of ground-based incoherent scatter and AE-C satellite measurements

The paper presents the results of comparisons of AE-C electron temperature of the ionosphere determined from the cylindrical electrostatic probe and the ion temperature of the ionosphere determined from the planar retarding potential analyzer with electron and ion temperatures determined from four incoherent scatter facilities: Arecibo, St. Santin, Millstone Hill, and Chatanika. Good agreement was obtained between the in situ and remote measurements of electron and ion temperatures. Longitudinal variations are found to be very important in the comparison of electron temperatures at some locations.

Benson, R. F.↗

2009 Goose Bay Experiment Ocean Measurements: Data - Part 1

During late February and early March 2009, a field experiment was performed using the NASA P3 over the Labrador Sea. During this experiment, expendable probes deployed from the aircraft acquired ocean mixed layer temperature, salinity and currents Probes were deployed during three flights of the four. Overall 7 AXBTs, 15 AXCTDs and 7 AXCPs were deployed with a success rate of nearly 70%. This is much lower than expected based on prior experience deploying from other aircraft. But given the difficulties associated with the Pneumatic Sonobuoy Launch Tube mechanism on the NASA P3, this rate likely can be improved significantly by using a different deployment mechanism. Additionally, two sets of collocated measurements of AXBTs, AXCPs and AXCTDs were made to verify the drop rates and measurements of the old AXBTs. While there were differences in the measurements, the old AXCTDs are performing well. The expendable data from the experiment are compared to the Argo profiles in the region to check for consistency. Comparisons indicate all the expendable probes acquired useful data and are well within the range of values measured by Argo floats.

Jacob, S. Daniel↗