Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TANKS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Automated Particle Analysis of Hanford Tank Wastes 241-AN-106, 241-AN-101, and 241-AW-105

This effort is involved in developing particle size and density distribution (PSDD) for the major phases within Hanford tank waste sludge. The object of this work has been to use automated particle analysis (APA) methods on the Scanning Electron Microscope (SEM) to provide PSDDs. The PSDD can be used to quantify the proportion of gibbsite particles likely to settle quickly and enable blending of wastes that may be prone to pipeline plugging such as the uranium phase, clarkeite with other wastes. The Hanford tank waste solids were analyzed with SEM combined with x-ray Energy Dispersive Spectroscopy (EDS) using APA. This method can allow thousands of individual particles to be characterized and so may provide a more representative view of the samples and information PSDDs. We characterized several as-received sludge samples and developed PSDD with APA. Sample preparation methods were found to impact the collected results, as it was more difficult to collect representative samples of the larger particles. Much of the material was also dried and cemented together that further impacted results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Molybdate Based Corrosion Inhibitor for use at the Savannah River Tank Farm Cooling Water System

The Savannah River Site (SRS) has relied on 51 underground storage tanks, many dating back to the 1950s, to store radioactive liquid waste generated from nuclear processing and radionuclide production. These tanks use carbon steel cooling coils, cooled by soft, acidic water, to dissipate the decayed heat produced by radioactive waste. For decades, following historical industry practices, chromate has been added to the cooling water (~450 ppm at pH 9-11) to effectively inhibit corrosion, ensuring cooling coil longevity. Inspections of failed coils reveal that chromate-treated surfaces are generally well-preserved.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Panel Session 98B: Treatment of Low-Activity Tank Waste at Hanford: Considering the Alternatives

This panel focused on alternative treatment of the Hanford Low-Activity Tank Waste. Currently, Tank Waste at the Hanford Site is to be separated into low-activity (LAW) and high-level waste (HLW) fractions, and then vitrified to produce immobilized LAW glass for onsite disposal, and HLW glass for ultimate geologic disposal. This panel discussed several commissioned studies by the National Laboratories, National Academies, and General Accountability Office to evaluate the risks, costs, and benefits associated with considering options for immobilizing portions of the Hanford LAW waste forms. Panelists with presentations: Analysis of Supplemental Treatment Approaches for Low-Activity Waste at the Hanford Nuclear Reservation Overview and Conclusions (Michael Stone); Analysis of Supplemental Treatment Approaches for Low-Activity Waste at the Hanford Nuclear Reservation: Disposal Performance Evaluation (Tom Brouns); National Academies Review of the Study on Supplemental Treatment Approaches of Low-Activity Waste at the Hanford Nuclear Reservation (Charles Ferguson); GAO Observations on Immobilizing Low-Activity Waste at DoE's Hanford Site (David Trimble)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effective thermal conductivity of insulation materials for cryogenic LH 2 storage tanks: A review

An accurate estimation of the effective thermal conductivity of various insulation materials is essential in the evaluation of heat leak and boil-off rate from liquid hydrogen storage tanks. In this work, we review the existing experimental data and various proposed correlations for predicting the effective conductivity of insulation systems consisting of powders, foams, fibrous materials, and multilayer systems. We also propose a first principles-based correlation that may be used to estimate the dependence of the effective conductivity as a function of temperature, interstitial gas composition, pressure, and structural properties of the material. We validate the proposed correlation using available experimental data for some common insulation materials. Further improvements and testing of the proposed correlation using laboratory scale data obtained using potential LH 2 tank insulation materials are also discussed.

08 HYDROGEN↗

Internal Insulation and Corrosion Control of Molten Chloride Storage Tanks

The National Renewable Energy Laboratory (NREL) is leading a multi-national team to validate the potential of a chloride-based molten-salt system that uses a ternary blend of MgCl2/KCl/NaCl to provide higher temperature thermal energy storage capability, thereby allowing for higher efficiency in the power block of next-generation concentrating solar power systems. While higher thermal stability, greater operating temperature, and a more efficient power cycle are possible, the molten chlorides present several unique challenges, including the design of internal liners to prevent the corrosion and thermal stress of alloy tank shells. This work discusses issues and potential solutions related to containment of molten chloride salt, specifically the design of the molten salt storage tanks.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Plutonium Retention by Crystalline Silicotitanate under Hyperalkaline Conditions Relevant to Tank-Side Cesium-Removal at the Hanford Site

Crystalline silicotitanate (CST) is used in Hanford’s Tank-Side Cesium-Removal (TSCR) process to selectively remove Cs-137 from highly caustic, nitrate-rich tank supernatants. Recent testing with actual waste samples suggests that CST can also retain measurable plutonium (Pu), which could affect radiological classification and disposal pathways for spent CST. To quantify this behavior, Pu partitioning to CST was studied under Hanford-relevant conditions using batch-contact experiments in a representative simulant (2 M NaNO3, 0.7 M NaOH). Isotherm data were measured and distribution ratios calculated, with Cs+ uptake used as benchmark. Under low-carbonate conditions, Pu was retained strongly by CST in systems initially contacted with either PuO2 nanoparticles (Pu(IV)) or aqueous Pu(VI), with distribution ratios of ~2,200–3,700 mL/g, generally exceeding those for Cs+ (~400–1,000 mL/g). Increasing carbonate concentration strongly reduced PuO2 nanoparticle retention; at [Na2CO3] = 1 M, distribution ratios decreased by up to one order of magnitude to roughly 100–300 mL/g. Electron microscopy suggests that Pu retention involves a combination of mechanisms such as PuO2 NP aggregation induced by CST leachate components, and association with CST bead surfaces.

Neumann, J.↗

Hanford Double Shell Waste Tank Corrosion Studies (Final Report FY2019)

During fiscal year (FY) 2019, the Savannah River National Laboratory (SRNL) focused on four primary tasks for Hanford Double Shell Tanks (DSTs) corrosion studies. The first task, New Limits, was a continuation from the electrochemical work started in FY16, to expand electrochemical testing to elevated temperatures and elevated hydroxide concentrations and evaluate how these factors will influence pitting corrosion. Using the pitting factor (PF) equation, these new conditions were validated to provide a conservative estimate for the susceptibility of pitting corrosion on legacy carbon steel. The second task, Secondary Liner Corrosion, focused on Vapor Space Corrosion (VSC) and immersion testing studies using two commercially available vapor corrosion inhibitors (VCIs). For this FY, the VCI strategy was applied mid-experiment to determine performance on weathered coupons. The third task, Long-Term Open Circuit Potential (OCP) Drift, was performed using simplified simulated chemistries to evaluate change in pitting corrosion risk due to evolution of corrosion potential for mill-scale and freshly polished 600-grit surfaces. Finally, the fourth task, Microbiologically-Influenced Corrosion (MIC) studies, was focused on the study of leak detection pit (LDP) water sent from the Hanford tank farm for determination of bacteria that can be conducive to corrosion using commercially available kits: BART TM and MICkit® 5. In addition, this FY, a secondary task was added which was a continuation of the study of the Quartz-enhanced Photoacoustic Spectroscopy (QEPAS) system. Work was started but was ultimately not pursued. A summary of each task performed is presented below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dissolution of Fluoride Salts in Hanford Tank Waste

The Direct Feed High-Level Waste (DFHLW) strategy seeks to bypass the Hanford Waste Treatment and Immobilization Plant Pretreatment Facility while retaining some processing functions to maximize waste feed loading and minimize high-level waste (HLW) waste volume. The DFHLW flowsheet needs leaching, washing, and solids concentration operations either in new or existing tanks. The effectiveness and efficiency of sludge washing has a substantial impact on DST space, mission duration, and the evaporation and low-activity waste (LAW) treatment operations required by these large wash-water additions. One target species requiring washing is fluoride. The HLW glass composition limits for fluorine drive operations to dissolve fluoride-bearing salts into the LAW fraction and thereby maximize waste loading in HLW glass. The fluoride in many high-level wastes at Hanford is predominantly in the form of fluoride-salt precipitates: villiaumite (NaF), kogarkoite (Na 3 FSO 4 ), and natrophosphate (Na 7 F(PO 4 ) 2 ·19H 2 O). Fluoride produces melter off-gas that creates corrosion risk in the off-gas system piping, while the sulfate and phosphate in the fluoride double salts kogarkoite and natrophosphate can be detrimental to glass waste loading. Fluoride salts are sparingly soluble, with solubilities ranging from approximately 40 to 130 kg per kL of pure water, and the dissolution kinetics of the three fluoride salts are not well known. Unexpected delays in a tank dissolution process could be encountered as a result of the lack of information about dissolution rates. In addition, if the double salts show transient non-stoichiometric dissolution of fluoride versus phosphate or sulfate, unexpectedly high concentrations of one of these other constituents could be produced. Washington River Protection Solutions authorized Pacific Northwest National Laboratory to collect the available data for fluoride salt dissolution rate, provide a scoping estimate of dissolution time if possible, and identify gaps in the understanding and predictive capability for estimating dissolution time. Open literature and Hanford reports were reviewed to document, understand, and (where possible) evaluate limitations on fluoride salt equilibria and dissolution kinetics, including both mass transport and surface reaction rate. Scoping estimates of dissolution time were made for mass-transfer-controlled dissolution of spherical particles of fluoride salts suspended in liquid. This is not the only potential governing mechanism; dissolution could be substantially slower if the surface reaction rate (the rate of release of ions from the surface) is the controlling mechanism. When the minimum amount of water for complete dissolution is used and the slip velocity between the liquid and suspended particles is less than or equal to the terminal settling velocity, the estimated mass-transfer rates allow 0.1 mm particles of fluoride salt to dissolve in minutes at 25 °C in water containing no other dissolved salts. Much larger solids, such as the 6-mm chunks that have been seen in heels, could take a few hours to more than a week to dissolve. The actual dissolution times will depend strongly on the actual slip velocity, the extent of particle suspension, constraint by surface reaction rates, the ratio of solvent to solid, and the presence of common ions that shift the solubility equilibria to restrict dissolution of fluoride salts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream (Volume 1)

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the Hanford AP tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing on a slipstream from the Hanford AP tank exhauster was conducted on March 23-24, 2018. This testing focused on both APR and PAPR cartridges. Previous testing of APR cartridges was conducted on the AP exhauster in June of 2016. However, an AP exhauster upgrade was completed in September 2016. In the most recent testing, slipstream vapors from the new AP exhauster were fed to two respirator cartridge test stands, one for the PAPR respirator cartridges and the other for the APR respirator cartridges. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—were also tested consecutively over the same two days as the APR cartridge tests, using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of Tank 22 Demister Solids Responsible for Preventing Adequate Purge Ventilation Flow (U)

In December 2020, about 2.5 grams of the solid material from the Tank 22 purge ventilation demister, responsible for preventing adequate purge ventilation flow, were delivered to Savannah River National Laboratory (SRNL) by Savannah River Remediation (SRR) for analysis to identify the chemical nature of the solids and possibly address why fresh water and caustic flushes with 50 wt. % sodium hydroxide solution are essentially ineffective in dissolving or dislodging the accumulated solids from the Tank 22 demister at low ambient temperature conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling of Glycolate Destruction in the Recycle Collection Tank

The Savannah River Site’s DWPF is being upgraded with the introduction of the NG flowsheet. Glycolic acid has been shown to be a superior alternative to formic acid for sludge processing. The new flowsheet improves or maintains necessary parameters such as 1) reduction of mercury, 2) adjustment of feed rheology, 3) pH stability, and 4) adjustment of melter oxidation/reduction potential. Further, the use of glycolic acid virtually eliminates the potential for catalytic hydrogen generation in DWPF processing DWPF process condensates are collected and returned to the Savannah River Site (SRS) CSTF. The RCT collects off-gas condensate during chemical processing, vitrification, and other unit operations performed in DWPF and is the singular return vessel delivering recycle effluent back to CSTF. Each batch of recycle will have a small amount of glycolate from chemical processing and melter off-gas condensates. To avoid potential flammability issues due to thermolysis of glycolate in the CSTF, Savannah River National Laboratory (SRNL) provided to Savannah River Remediation (SRR) at their request a Task Technical and Quality Assurance Plan (TTQAP) to quantify and mitigate glycolate returns via DWPF’s recycle stream. The request included testing of a process to oxidize glycolate and other organic species that are responsible for hydrogen generation from thermolysis. Following that work SRR provided a Task Technical Request (TTR) that requested process modeling. In 2021 a TTQAP was issued to cover the modeling work. Modeling draws data from laboratory scale studies using chemical simulants and radioactive waste samples. Chemical kinetic modeling was performed to evaluate the feasibility of using sodium permanganate to destroy glycolate in the RCT. The results from the laboratory studies were summarized in a series of reports. Reference 9 is a report of lab scale processing of actual DWPF Slurry Mix Evaporate Condensate Tank (SMECT) and Offgas Condensate Tank (OGCT) samples in the SRNL Shielded Cells. Tests at caustic conditions demonstrated sodium permanganate was effective in converting glycolate to oxalate, and permanganate (Mn 7+ ) is reduced to manganate (Mn 6+ ) with no significant formation of carbon dioxide or carbonate. Equation (1) was found to best describe the observed reaction of glycolate with permanganate under nominal (60 to 145 mg/L in RCT) glycolate entrainment conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sludge Batch 10 (SB10) Acceptance Evaluation: Radionuclide Concentrations in Tank 51 Washed Qualification Sample

Savannah River National Laboratory (SRNL) has been tasked with the radionuclide characterization of the washed Sludge Batch 10 (SB10) qualification sample. The washed SB10 qualification sample is based on SRR Engineering guidance and the sample slurry is expected to be similar in composition to Tank 51 slurry after final preparations for transfer to Tank 40. Forty-four radionuclides along with total alpha and beta activity have been reported herein. These radionuclide measurements are required for the Defense Waste Processing Facility (DWPF) Radiological Evaluation Program, DWPF Technical Safety Requirements (TSR)/Waste Acceptance Criteria (WAC) Evaluation, and the DWPF Solid Waste Characterization Program.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fiscal Year 2022. Filtration of Hanford Tank 241-AP-101 Supernatant at 16 °C

Bench-scale filtration testing of ~9 liters of supernatant from Hanford waste tank 241-AP-101, chilled to 16 °C, was conducted using a backpulse dead-end filter (BDEF) filtration system equipped with a feed vessel and a Mott inline filter Model 6610 (Media Grade 5) in the hot cells of the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. This was done to assess the performance of the anticipated third feed to the Tank Side Cesium Removal (TSCR) system. The as-received samples were diluted to the target sodium concentration and transferred to 1.5-liter polyethylene bottles and held at 16 °C for approximately 1 week prior to filtration. The feed was filtered through the BDEF system at a targeted flux of 0.065 gpm/ft 2 to match the prototypic operation of the TSCR system. During filtration, the differential pressure required to effect filtration at 0.065 gpm/ft 2 increased little over the filtration campaign and never reached 2 psid (the TSCR action limit). This indicates that the TSCR filter should perform well when processing AP-101 supernatant. After completing filtration of the AP-101 feed, the filter was cleaned. Solids concentrated from the backpulse solutions displayed sodium nitrate-type phases, aluminum and silicon phases reported as cancrinite or nitrate-cancrinite, a mixed chromium-aluminum oxide, iron oxides, and Ca-bearing phases (calcite). Scanning electron microscopy analyses showed that the average particle size was 0.5 micron.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Critical and Californium Source-Driven Noise Analysis Subcritical Measurements with an Unreflected Cylindrical Tank of Mixed Uranium-Plutonium Nitrate Solution

The reported experiments were performed by Oak Ridge National Laboratory (ORNL) at the Battelle Northwest Laboratory’s (now Pacific Northwest National Laboratory) critical experiments facility at Hanford, Washington in 1981 and used 16 days of critical facility time, not including 10 days for setup and removal of ORNL equipment. These measurements were to assess the capability of the Cf source-driven noise analysis (CSDNA) method to measure the subcriticality (keff) of mixed U-Pu nitrate solutions. In addition to the CSNDA measurements, measurements were also performed near delayed criticality where CSDNA measurements cannot be performed. This report documents the experiments that were not reported at that time by presenting the ORNL experimental results and any online analysis performed during and shortly after the measurements. The mixed nitrate solution had a U concentration at 188 grams per liter (g/L), a Pu concentration of 280 g/L, free acid normality of 2.80, H ion molarity of 5.9 and a specific gravity of 1.754 g/cm 3 , a 240 Pu isotopic content of 7.981 wt. %, and a 235 U isotopic content of 0.724 wt. %. The stainless-steel tank for the solution had an inside diameter of 35.38 cm, an outside diameter of 35.53 cm, a height of 56.72 cm, and bottom thickness of 0.9525 cm. A Zircaloy pipe with a 3.1496 cm outside diameter, a 2.7788 cm inside diameter, and bottom thickness of 0.635 cm was available for insertion of the Cf source in the center of the fissile solution. The Cf source was also located at the outside surface of the tank (solution height varied from 10 to 53 cm) and in the center of the solution (solution height varied from 10 to 60.7 cm). The CSDNA measurements were not analyzed online to determine the subcritical neutron multiplication factors. At all subcritical states, the break frequency noise analysis data was fitted to obtain the prompt neutron decay constant. The neutron multiplication factors were determined for the two configurations of the measurements near delayed criticality. The subcritical neutron multiplication factors from the CNSDA measurements can be obtained with further analysis. However, the near delayed critical configuration, the prompt neutron decay constants, the count rates, and the measured cross and auto power spectral densities can be calculated directly for benchmarking. Much of data presented in this report are from ORNL notes—not in the ORNL logbooks. For the final benchmark analysis, the data from the Battelle Northwest Laboratory (which operated the critical facility in 1981) critical facility logbook should be consulted and be incorporated where appropriate. The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Criticality Safety Benchmark Program (ICSBEP) or Nuclear Energy Agency benchmark. The data from these measurements are available from the ORNL Records Management Services Department, and the logbook is available from ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hanford Double Shell Waste Tank Corrosion Studies (Final Report FY2021)

For fiscal year (FY) 2021, the Savannah River National Laboratory (SRNL) focused on two experimental tasks related to Hanford Double Shell Tank (DST) chemistry and integrity. The first task focused on understanding risk of corrosion due to formation of either continuous layers or discrete patches of deposits on the tanks’ inner sidewalls and bottoms. The second task studied vapor space corrosion (VSC) inhibition of the secondary liner using vapor corrosion inhibitors (VCIs) at dosages less than the manufacturer recommended and a control test in which no VCIs were added.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 1

Washington River Protection Solutions (WRPS) conducted tests of four types of chemical cartridges for air-purifying respirators (APR) and powered air-purifying respirators (PAPR) to determine the period of time the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the Hanford AX tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing a cartridge service life. Testing is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing using vapors from a Hanford AX tank farm exhauster slipstream was conducted from August 25–27, 2017. Vapors from the exhauster slipstream were fed to two respirator cartridge test stands developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Four different cartridges were assessed. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using an APR cartridge test stand. Multipurpose PAPR cartridges—MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR57 (TL2) (3M Company, Maplewood, Minnesota)—also were tested over the same two days using a separate PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗