Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Modeling, design and thermal performance of a BIPV/T system thermally coupled with a ventilated concrete slab in a low energy solar house: Part 1, BIPV/T system and house energy concept

This paper is the first of two papers that describe the modeling, design, and performance assessment based on monitored data of a building-integrated photovoltaic-thermal (BIPV/T) system thermally coupled with a ventilated concrete slab (VCS) in a prefabricated, two-storey detached, low energy solar house. This house, with a design goal of near net-zero annual energy consumption, was constructed in 2007 in Eastman, Quebec, Canada - a cold climate area. Several novel solar technologies are integrated into the house and with passive solar design to reach this goal. An air-based open-loop BIPV/T system produces electricity and collects heat simultaneously. Building-integrated thermal mass is utilized both in passive and active forms. Distributed thermal mass in the direct gain area and relatively large south facing triple-glazed windows (about 9% of floor area) are employed to collect and store passive solar gains. An active thermal energy storage system (TES) stores part of the collected thermal energy from the BIPV/T system, thus reducing the energy consumption of the house ground source heat pump heating system. This paper focuses on the BIPV/T system and the integrated energy concept of the house. Monitored data indicate that the BIPV/T system has a typical efficiency of about 20% for thermal energy collection, and the annual space heating energy consumption of the house is about 5% of the national average. A thermal model of the BIPV/T system suitable for preliminary design and control of the airflow is developed and verified with monitored data. (author)

14 SOLAR ENERGY↗

Medium-Duty Delivery Truck Integrated Bidirectional Wireless Power Transfer System With Grid and Stationary Energy Storage System Connectivity

Electric vehicles (EVs) can provide power to the grid or buildings similar to distributed energy resources (DER) for energy balancing applications or optimizing the operation of the microgrids in harmony with the other DER assets. This article presents the operating modes of a bidirectional wireless power transfer (WPT) system designed for a medium-duty package delivery vehicle. The WPT system designed for this study can transfer 20 kW of power across 11 in of air gap using custom-designed double-D (DD) couplers with LCC–LCC tuning networks. The proposed system utilizes a 480-V three-phase grid connection, a plug-in hybrid delivery truck with bidirectional WPT, and a stationary energy storage system (SESS) that can be connected to the primary-side dc link. Due to the differences in primary and secondary dc bus voltages, and considering the voltage of the SESS, asymmetric voltage gains were used in the system. Sensitivity analyses of this system with respect to these voltage levels are presented. Five different operating modes of the grid, SESS, and the EV battery are investigated with experimental results. Control algorithms are described for grid-to-vehicle (G2V) and vehicle-to-grid (V2G) operating modes. A bidirectional WPT system is operated with a power factor of 0.99 on the grid side in every operating mode. The EV battery was charged with 20.3 kW with an overall efficiency of 93.02% in the G2V operating mode. Finally, in the V2G operating mode, the WPT system provided 12.82 kW of power back to the grid with an overall efficiency of 89.08%.

25 ENERGY STORAGE↗

Composite Socio-Technical Systems: A Method for Social Energy Systems

In order to model and study the interactions between social on technical systems, a systemic method, namely the composite socio-technical systems (CSTS), is proposed to incorporate social systems, technical systems and the interaction mechanism between them. A case study on University of Denver (DU) campus grid is presented in paper to demonstrate the application of the proposed method. In the case study, the social system, technical system, and the interaction mechanism are defined and modelled within the framework of CSTS. Distributed and centralized control and management schemes are investigated, respectively, and numerical results verifies the feasibility and performance of the proposed composite system method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Secure environment establishment for FPGA-based safety-critical systems: quality management system context - 159

The paper discusses importance of secure development and operational environment establishment process, its particular stages, including security-oriented analysis and assessment of safety-critical instrumentation and control (I and C) systems. Two particular aspects are covered - security assessment and security assurance related to processes established by Quality Management System (QMS). One of the underlying ideas for the security assessment approach is in performance of gap analysis. Such analysis considers influence of all different factors within I and C system development process, and further application of Intrusion Modes and Effect Criticality Analysis (IMECA) technique. It makes the approach applicable to various safety-critical systems, considering underlying technologies (for example, Field-Programmable Gate Arrays (FPGA). Nowadays FPGA technology is often used in wide spectrum of hardware devices - from personal devices to complex I and C systems for Nuclear Power Plants (NPPs). The problem of cyber security assessment and assurance for FPGA technology in general and its application in safety-critical I and C systems in particular is not completely solved due to several reasons that cover regulations, QMS processes, implementation of development and verification activities, etc. The paper overviews existing regulations, which cover various aspects of NPP I and C systems development and operation, FPGA technology implementation, and secure development and operational environment establishment and assurance. The paper also emphasizes that complex approach should be used to identify and mitigate all specific vulnerabilities thorough the whole life cycle on the basis on Intrusion Modes, Effect and Criticality Analysis technique. The paper also proposes approach to the development of safety-critical I and C systems in the scope of cyber security assurance process at developer site. Secure development environment is described as a key factor during the development process and the paper also discusses establishment and maintenance of such environment as a part of company's Nuclear Quality Assurance's QMS. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimal Strategies for Hybrid Battery‐Storage Systems Design

As stationary hybrid energy‐storage systems (HESS) for power systems applications have recently drawn interest due to their enhanced performance and decreasing cost, developing systematic approaches for HESS design while considering controls is gaining traction. Herein, a method is presented to optimally design hybrid battery storage by proposing a mathematical modeling framework, formulated as a mixed integer linear programming model. The optimization is capable of handling multiple subsystems of batteries, considering their economic and technological performance. Decisions involve sizing of the batteries, optimal temporal and strategic dispatch to end uses, and energy sources for charging each battery. The applicability of the model is tested on four case studies for three battery chemistries representing distinct objectives: high‐power, high‐energy, and second life. Compared to traditionally designed battery storage with a homogeneous battery, optimally designed hybrid systems can save 12%–26% of system costs, depending on the nature of the dispatch profile. Findings point to design preference toward the second life battery supplemented with some high‐power or high‐energy battery capacity, or both. With the utilized electricity price structure, customers can experience approximately 10%–35% reduction in their bills.

Koleva, Mariya↗

Microbial Enhanced Oil Recovery in Fractional-Wet Systems: A Pore-Scale Investigation

Microbial enhanced oil recovery (MEOR) is a technology that could potentially increase the tertiary recovery of oil from mature oil formations. However, the efficacy of this technology in fractional-wet systems is unknown, and the mechanisms involved in oil mobilization therefore need further investigation. Our MEOR strategy consists of the injection of ex situ produced metabolic byproducts produced by Bacillus mojavensis JF-2 (which lower interfacial tension (IFT) via biosurfactant production) into fractional-wet cores containing residual oil. Two different MEOR flooding solutions were tested; one solution contained both microbes and metabolic byproducts while the other contained only the metabolic byproducts. The columns were imaged with X-ray computed microtomography (CMT) after water flooding, and after MEOR, which allowed for the evaluation of the pore-scale processes taking place during MEOR. Results indicate that the larger residual oil blobs and residual oil held under relatively low capillary pressures were the main fractions recovered during MEOR. Residual oil saturation, interfacial curvatures, and oil blob sizes were measured from the CMT images and used to develop a conceptual model for MEOR in fractional-wet systems. Overall, results indicate that MEOR was effective at recovering oil from fractional-wet systems with reported additional oil recovered (AOR) values between 44 and 80%; the highest AOR values were observed in the most oil-wet system.

02 PETROLEUM↗

System design and analysis of thermal power dispatch systems for boiling water reactors

Nuclear power plants are crucial to meeting net zero emission goals and achieving energy sustainability. Integrating these plants with clean energy technologies such as high-temperature steam electrolysis (HTSE) may improve the efficiency and economic competitiveness of these plants. Here, the current study investigates the design and operation of a thermal power dispatch (TPD) system for coupling boiling water reactors (BWRs) to HTSE plants. The TPD system extracts a portion of the steam from the reactor’s main steam line and transfers its thermal energy to an HTSE plant through a power transport loop. A TPD system for 5 % steam extraction has been designed and the system performance during steady and transient operations has been analyzed. The TPD system dispatched a total of 197 MW thermal energy to the HTSE plant under nominal design conditions. Saturated steam at 7.17 MPa from the BWR plant was condensed and subcooled to a temperature of 168 °C, while a mass flow rate of 91.1 kg/s of superheated steam was dispatched to the HTSE plant. Furthermore, the system performance during transient operation showed a continuous transition from the initial hot standby mode to the nominal power dispatch level. The transient simulation results emphasized the importance of investigating component level performance for the TPD system design. The current results will guide future works on the development of integrated energy systems for hydrogen production or process heat applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Coupling fast fluid dynamics and multizone airflow models in Modelica Buildings library to simulate the dynamics of HVAC systems

Multizone models are widely used in building airflow and energy performance simulations due to their fast computing speed. However, multizone models assume that the air in a room is well mixed, consequently limiting their application. In specific rooms where this assumption fails, the use of computational fluid dynamics (CFD) models may be an alternative option. Previous research has mainly focused on coupling CFD models and multizone models to study airflow in large spaces. While significant, most of these analyses did not consider the coupled simulation of the building airflow with the building’s Heating, Ventilation, and Air-Conditioning (HVAC) systems. This paper tries to fill the gap by integrating the models for HVAC systems with coupled multizone and CFD simulations for airflows, using the Modelica simulation platform. To improve the computational efficiency, we incorporated a simplified CFD model named fast fluid dynamics (FFD). We first introduce the data synchronization strategy and implementation in Modelica. Then, we verify the implementation using two case studies involving an isothermal and a non-isothermal flow by comparing model simulations to experiment data. Afterward, we study another three cases that are deemed more realistic. Furthermore, this is done by attaching a variable air volume (VAV) terminal box and a VAV system to previous flows to assess the capability of the models in studying the dynamic control of HVAC systems. Finally, we discuss further research needs on the coupled simulation using the models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-Driven Distributed Algorithms for Estimating Eigenvalues and Eigenvectors of Interconnected Dynamical Systems

Here, the paper presents data-driven algorithms to estimate in a distributed manner the eigenvalues, right and left eigenvectors of an unknown linear (or linearized) interconnected dynamic system. In particular, the proposed algorithms do not require the identification of the system model in advance before performing the estimation. As a first step, we consider interconnected dynamical system with distinct eigenvalues. The proposed strategy first estimates the eigenvalues using the well-known Prony method. The right and left eigenvectors are then estimated by solving distributively a set of linear equations. One important feature of the proposed algorithms is that the topology of communication network used to perform the distributed estimation can be chosen arbitrarily, given that it is connected, and is also independent of the structure or sparsity of the system (state) matrix. The proposed distributed algorithms are demonstrated via a numerical example.

97 MATHEMATICS AND COMPUTING↗

Solubility of U(VI) in chloride solutions. III. The stable oxides/hydroxides in MgCl 2 systems: Pitzer activity model for the system UO 2 2+ –Na + –K + –Mg 2+ –H + –OH – –Cl – –H 2 O(l)

Here we have developed new chemical, thermodynamic and activity models for the system UO 2 2+ –Na + –K + –Mg 2+ –H + –OH – –Cl – –H 2 O(l) within the Pitzer approach. The new thermodynamic model is based on previously reported data treated within the SIT approach for NaCl and KCl systems, as well as on new experimental data determined in this work for the MgCl 2 system. The solubility of uranium(VI) was studied in 0.01–5.15 mol·kg w –1 MgCl 2 solutions at pH m = 4.1–9.7 (with pH m = –log [H + ]). Experiments were performed under Ar atmosphere at T = (22 ± 2) °C. In all investigated systems, the solubility of U(VI) is controlled by metaschoepite, UO 3 ·2H 2 O(cr). In contrast to previously investigated NaCl and KCl systems, no ternary Mg–U(VI)–OH(s) solid phases formed in alkaline MgCl 2 solutions within the timeframe of this study (≤ 200 days). A very significant increase in the solubility (up to 3 log 10 -units) is observed in acidic to near-neutral pH m conditions when increasing MgCl 2 concentration from 0.01 to 5.15 mol·kg w –1 , which reflects the strong ion interaction processes taking place in concentrated MgCl 2 brines. The solubility of UO 3 ·2H 2 O(cr) in the investigated NaCl, KCl and MgCl 2 solutions is well described with the solubility and hydrolysis constants recommended by Altmaier et al., (2017) and NEA–TDB, and a Pitzer activity model derived in the present work. The latter model considers experimental data reported in the present study and available in the literature for NaCl, KCl and MgCl 2 systems (solubility, potentiometric and spectroscopic data), in combination with well-stablished estimation methods and correlations with SIT coefficients. Finally, chemical, thermodynamic and Pitzer activity models provided in this work for the system UO 2 2+ –Na + –K + –Mg 2+ –H + –OH – –Cl – –H 2 O(l) accurately describe all evaluated datasets, and represent an adequate tool for the calculation of U(VI) solubility and aqueous speciation in a variety of geochemical conditions including concentrated brine systems of relevance in salt-based repositories for nuclear waste disposal.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion-beam irradiation of lanthanum compounds in the systems La{sub 2}O{sub 3}-Al{sub 2}O{sub 3} and La{sub 2}O{sub 3}-TiO{sub 2}

Thin crystals of La{sub 2}O{sub 3}, LaAlO{sub 3}, La{sub 2/3}TiO{sub 3}, La{sub 2}TiO{sub 5}, and La{sub 2}Ti{sub 2}O{sub 7} have been irradiated in situ using 1 MeV Kr{sup 2+} ions at the Intermediate Voltage Electron Microscope-Tandem User Facility (IVEM-Tandem), Argonne National Laboratory (ANL). We observed that La{sub 2}O{sub 3} remained crystalline to a fluence greater than 3.1x10{sup 16} ions cm{sup -2} at a temperature of 50 K. The four binary oxide compounds in the two systems were observed through the crystalline-amorphous transition as a function of ion fluence and temperature. Results from the ion irradiations give critical temperatures for amorphisation (T{sub c}) of 647 K for LaAlO{sub 3}, 840 K for La{sub 2}Ti{sub 2}O{sub 7}, 865 K for La{sub 2/3}TiO{sub 3}, and 1027 K for La{sub 2}TiO{sub 5}. The T{sub c} values observed in this study, together with previous data for Al{sub 2}O{sub 3} and TiO{sub 2}, are discussed with reference to the melting points for the La{sub 2}O{sub 3}-Al{sub 2}O{sub 3} and La{sub 2}O{sub 3}-TiO{sub 2} systems and the different local environments within the four crystal structures. Results suggest that there is an observable inverse correlation between T{sub c} and melting temperature (T{sub m}) in the two systems. More complex relationships exist between T{sub c} and crystal structure, with the stoichiometric perovskite LaAlO{sub 3} being the most resistant to amorphisation. - Graphical abstract: La{sub 2}TiO{sub 5} with atypical co-ordination for Ti, TiO{sub 5} is found to be different in radiation resistance to La{sub 2}Ti{sub 2}O{sub 7} and La{sub 2/3}TiO{sub 3}. Irradiation of La-Ti-O, and La-Al-O based systems has found that radiation damage resistance is related to the ability of the system to disorder.

36 MATERIALS SCIENCE↗

Distribution system versus bulk power system: identifying the source of electric service interruptions in the US

This study reports on the results from efforts by the Institute of Electric and Electronics Engineers (IEEE) Distribution Reliability Working Group (DRWG) and the U.S. Energy Information Administration (EIA) to improve the usefulness of reliability metrics by developing and then applying consistent, yet distinct measures of the continuity of supply based on the portion of the electric power system from which power interruptions originate: the lower voltage distribution system versus the high‐voltage bulk power system. The modified metrics better support reliability planning in the US because they separately measure the effectiveness of actions to improve reliability made by the two distinct groups of firms (and their regulators or oversight bodies) that are responsible for planning and operating each portion of the US electric power system. The authors then present for the first time quantitative information on the reliability of each portion of the US electric power system. When reliability is measured using the system average interruption duration index and the system average interruption frequency index, they find that the distribution system accounts for at least 94 and 92%, respectively, of all interruptions. They also find that these relationships have been stable over the recent past.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Conservation Voltage Reduction (CVR) via Two-Timescale Control in Unbalanced Power Distribution Systems

Voltage control devices are employed in power distribution systems to reduce the power consumption by operating the system closer to the lower acceptable voltage limits; this technique is called conservation voltage reduction (CVR). The different modes of operation for system’s legacy devices (with binary control) and new devices (e.g. smart inverters with continuous control) coupled with variable photovoltaic (PV) generation results in voltage fluctuations which makes it challenging to achieve CVR objective. This paper presents a two-timescale control of feeder’s voltage control devices to achieve CVR that includes (1)a centralized controller operating in a slower time-scale to coordinate voltage control devices across the feeder and (2) local controllers operating in a faster timescale to mitigate voltage fluctuations due to PV variability. The centralized controller utilizes a three-phase optimal power flow model to obtain the decision variables for both legacy devices and smart inverters. The local controllers operate smart inverters to minimize voltage fluctuations and restore nodal voltages to their reference values by adjusting the reactive power support. The proposed approach is validated using the IEEE-123 bus (medium-size) and R3-12.47-2 (large-size) feeders. It is demonstrated that the proposed approach is effective in achieving the CVR objective for unbalanced distribution systems.

optimal control, distributed generation, fluctuati↗

Architecture, implementation, and testing of a multiple-shell gas injection system for high current implosions on the Z accelerator

Tests are ongoing to conduct {approx}20 MA z-pinch implosions on the Z accelerator at Sandia National Laboratory using Ar, Kr, and D{sub 2} gas puffs as the imploding loads. The relatively high cost of operations on a machine of this scale imposes stringent requirements on the functionality, reliability, and safety of gas puff hardware. Here we describe the development of a prototype gas puff system including the multiple-shell nozzles, electromagnetic drivers for each nozzle's valve, a UV pre-ionizer, and an inductive isolator to isolate the {approx}2.4 MV machine voltage pulse present at the gas load from the necessary electrical and fluid connections made to the puff system from outside the Z vacuum chamber. This paper shows how the assembly couples to the overall Z system and presents data taken to validate the functionality of the overall system.

42 ENGINEERING↗

Optimal system size for complex dynamics in random neural networks near criticality

In this article, we consider a model of dynamical agents coupled through a random connectivity matrix, as introduced by Sompolinsky et al. [Phys. Rev. Lett. 61(3), 259–262 (1988)] in the context of random neural networks. When system size is infinite, it is known that increasing the disorder parameter induces a phase transition leading to chaotic dynamics. We observe and investigate here a novel phenomenon in the sub-critical regime for finite size systems: the probability of observing complex dynamics is maximal for an intermediate system size when the disorder is close enough to criticality. We give a more general explanation of this type of system size resonance in the framework of extreme values theory for eigenvalues of random matrices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Relation between delayed feedback and delay-coupled systems and its application to chaotic lasers

We present a systematic approach to identify the similarities and differences between a chaotic system with delayed feedback and two mutually delay-coupled systems. We consider the general case in which the coupled systems are either unsynchronized or in a generally synchronized state, in contrast to the mostly studied case of identical synchronization. We construct a new time-series for each of the two coupling schemes, respectively, and present analytic evidence and numerical confirmation that these two constructed time-series are statistically equivalent. From the construction, it then follows that the distribution of time-series segments that are small compared to the overall delay in the system is independent of the value of the delay and of the coupling scheme. By focusing on numerical simulations of delay-coupled chaotic lasers, we present a practical example of our findings.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gas mixing system for imaging of nanomaterials under dynamic environments by environmental transmission electron microscopy

A gas mixing manifold system that is capable of delivering a stable pressure stream of a desired composition of gases into an environmental transmission electron microscope has been developed. The system is designed to provide a stable imaging environment upon changes of either the composition of the gas mixture or upon switching from one gas to another. The design of the system is described and the response of the pressure inside the microscope, the sample temperature, and sample drift in response to flow and composition changes of the system are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

How large are nonadiabatic effects in atomic and diatomic systems?

With recent developments in simulating nonadiabatic systems to high accuracy, it has become possible to determine how much energy is attributed to nuclear quantum effects beyond zero-point energy. Here, we calculate the non-relativistic ground-state energies of atomic and molecular systems without the Born-Oppenheimer approximation. For this purpose, we utilize the fixed-node diffusion Monte Carlo method, in which the nodes depend on both the electronic and ionic positions. Our report shows the ground-state energies for all systems studied, ionization energies for the first-row atoms and atomization energies for the first-row hydrides. We find the ionization energies of the atoms to be nearly independent of the Born-Oppenheimer approximation, within the accuracy of our results. The atomization energies of molecular systems, however, show small effects of the nonadiabatic coupling between electrons and nuclei.

74 ATOMIC AND MOLECULAR PHYSICS↗