Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Temperature and nonlinearity corrections for a photodiode array spectrometer used in the field

Temperature and nonlinearity effects are two important factors that limit the use of photodiode array spectrometers. Usually the spectrometer is calibrated at a known temperature against a reference source of a particular spectral radiance, and then it is used at different temperatures to measure sources of different spectral radiances. These factors are expected to be problematic for nontemperature-stabilized instruments used for in-the-field experiments, where the radiant power of the site changes continuously with the sun tilt. This paper describes the effect of ambient temperature on a nontemperature-stabilized linear photodiode array spectrometer over the temperature range from 5 deg. C to 40 deg. C. The nonlinearity effects on both signal amplification and different levels of radiant power have also been studied and are presented in this paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

What Caused the Lead burn-out in Spectrometer Magnet 2B

The spectrometer solenoids are supposed to be the first magnets installed in the MICE Cooling Channel. The results of the test of Spectrometer Magnet 2B are reported in a previous MICE Note. Magnet 2B was tested with all five coils connected in series. The magnet failed because a lead to coil M2 failed before it could be trained to its full design current of 275 A. First, this report describes the condition of the magnet when the lead failure occurred. The lead that failed was between the cold mass feed-through and the heavy lead that connected to coil M2 and the quench protection diodes. It is believed that the lead failed because the minimum propagation zone (MPZ) length was too short. The quench was probably triggered by lead motion in the field external to the magnet center coil. The effect of heat transfer on quench propagation and MPZ length is discussed. The MPZ length is compared for a number of cases that apply to the spectrometer solenoid 2B as built and as it has been repaired. The required heat transfer coefficient for cryogenic stability and the quench propagation velocity along the leads are compared for various parts of the Magnet leads inside the cold mass cryostat. The effect of the insulation on leads on heat transfer is and stability is discussed.

42 ENGINEERING↗

Ion-optical and Associated Magnet Feasibility Study of a High Rigidity Spectrometer

Ion-optical and magnet-feasibility studies were performed for the High Rigidity Spectrometer (HRS) at the Facility for Rare Isotope Beam (FRIB). The High Rigidity Spectrometer (HRS) will be the centerpiece experimental tool of the Facility for Rare-Isotope Beams (FRIB) fast-beam program The high magnetic rigidity of the HRS (8 Tm) will match the rigidities at which rare-isotope production yields at the FRIB fragment separator are maximum across the entire chart of nuclei and enable experiments with the most neutron-rich nuclei available at FRIB. Gain factors in luminosity of up to two orders of magnitude are achievable compared to running with existing spectrometers, which have a maximum rigidity of 4 Tm. The ion-optical studies were performed to ensure that the layout and properties meet the requirements for the scientific program envisioned for and articulated by the FRIB user community. Based on the ion-optical studies, magnet-feasibility studies were carried out to ensure that the magnets required for the HRS meet these requirements and can be constructed. The results of the ion-optical and magnet-feasibility studies form the basis of the pre-conceptual design for the HRS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Spectrum Determination for the Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) with a Multi-Sphere Spectrometer

This report presents the work that was performed to determine the neutron energy spectrum (spectrum) of the Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) with a neutron Multi-Sphere Spectrometer (MSS). The spectrometer measurements were performed when the generator is in an INL Materials and Fuels Complex (MFC) laboratory. The measurements were used in a spectrum unfolding software to calculate the neutron spectrum. Based on initial testing of the MSS spectrometer and experience with the unfolding software, an MMRTG spectrum is reported and a justification for the spectrum is provided.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

What Happened with Spectrometer Magnet 2B

The spectrometer solenoid is supposed to be the first magnets installed in MICE [1]-[4]. This report described what happened during the test of the MICE spectrometer solenoid 2B. First, the report describes the temperatures in the magnet, the cooler top plate and the shield during the run where the magnet quenched at 258 A. During this quench, a lead between the bottom of the HTS leads and the diode bank burned out causing the magnet to quench. Second, three methods for measuring the net heat flow into the cold mass are described. Third, there is a discussion of possible resistive heating in the HTS leads between liquid helium temperature and the copper plate, which is at about 50 K. Fourth, there is a discussion of the measured first stage heat loads in the magnet, when there is no current in the magnet. The first stage heat load calculations are based on knowing the first stage temperatures of the three two-stage pulse tube coolers and the single stage GM cooler. Fifth, the estimated heat load to the first stage when the magnet has current in it is discussed. Sixth, there is a comparison of the stage 1 heat loads in magnet 1A [5], magnet 2A [6], and magnet 2B [7]. Finally there is a discussion of recommended changes for improving the spectrometer solenoids so that the coolers can keep them cold.

42 ENGINEERING↗

Nanograting-based compact VUV spectrometer and beam profiler for in-situ characterization of high-order harmonic generation light sources

A compact, versatile device for VUV beam characterization is presented. It combines the functionalities of a VUV spectrometer and a VUV beam profiler in one unit and is entirely supported by a standard DN200 CF flange. The spectrometer employs a silicon nitride transmission nanograting in combination with a micro-channel plate based imaging detector. This enables the simultaneous recording of wavelengths ranging from 10 nm to 80 nm with a resolution of 0.25 nm to 0.13 nm. Spatial beam profiles with diameters up to 10 mm are imaged with 0.1 mm resolution. The setup is equipped with an in-vacuum translation stage that allows for in situ switching between the spectrometer and beam profiler modes and for moving the setup out of the beam. The simple, robust design of the device is well suited for non-intrusive routine characterization of emerging laboratory- and accelerator-based VUV light sources. Operation of the device is demonstrated by characterizing the output of a femtosecond high-order harmonic generation light source.

42 ENGINEERING↗

Measuring the masses of the charged hadrons using a RICH as a precision velocity spectrometer

The Selex experiment measured several billion charged hadron tracks with a high precision magnetic momentum spectrometer and high precision RICH velocity spectrometer. We have analyzed these data to simultaneously measure the masses of all the long lived charged hadrons and anti-hadrons from the {pi} to the {Omega} using the same detector and technique. The statistical precision achievable with this data sample is more than adequate for 0.1% mass measurements. We have used these measurements to develop and understand the systematic effects in using a RICH as a precision velocity spectrometer with the goal of measuring 10 masses with precision ranging from 100 KeV for the lightest to 1000 KeV for the heaviest. This requires controlling the radius measurement of RICH rings to the {approx} 10{sup -4} level. Progress in the mass measurements and the required RICH analysis techniques developed are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Methods for optical calibration of the BigBite hadron spectrometer

In this study, the techniques for the optical calibration of Jefferson Lab's large-acceptance magnetic hadron spectrometer, BigBite, have been examined. The most consistent and stable results were obtained using a method based on singular value decomposition. In spite of the complexity of the optics, the particles' positions and momenta at the target have been precisely reconstructed from the coordinates measured in the detectors by means of a single back-tracing matrix. The technique is applicable to any similar magnetic spectrometer and any particle type. For 0.55 GeV/c protons, we have established a vertex resolution of 1.2 cm, angular resolutions of 7 mrad and 13 mrad (in-plane and out-of-plane, respectively), and a relative momentum resolution of 1.6%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Influence of Emissions and Aqueous Processing on Particles Containing Black Carbon in a Polluted Urban Environment: Insights From a Soot Particle-Aerosol Mass Spectrometer

Inorganic and organic coatings on black carbon (BC) particles can enhance light absorption and affect atmospheric lifetimes of BC-containing particles and thus have significant implications for climate. To study the physical and chemical characteristics of atmospheric BC and BC-associated coatings, a soot particle-aerosol mass spectrometer was deployed during the winter of 2014–2015 in Fresno, a city located in the San Joaquin Valley of California, to selectively analyze BC-containing particles. Comparing soot particle-aerosol mass spectrometer measurements to those from the collocated single-particle soot photometer (SP2) and high-resolution aerosol mass spectrometer, we found that 17% of total submicrometer aerosol mass was associated with BC-containing particles, suggesting that a majority of the fine particles in Fresno contained no BC. Most BC-containing particles appeared to be associated with residential wood burning and vehicular traffic. These particles typically had a bulk-average mass ratio of coating to BC (R coat/rBC ) less than 2. However, during periods of persistent fog larger R coat/rBC values were observed, with the coatings primarily composed of secondary inorganic and organic components that likely resulted from aqueous-phase processing. Specifically, compared to periods with less fog, the BC coating increased in concentration and contained a larger fraction of nitrate and oxidized organic matter. The size distributions of BC and associated organic coating were generally centered around 300 nm in vacuum aerodynamic diameter. However, during foggy periods BC had an additional peak at ~400 nm and organics and nitrate displayed a prominent mode in the accumulation size range.

54 ENVIRONMENTAL SCIENCES↗

The Psyche Gamma-Ray and Neutron Spectrometer

A Gamma-Ray and Neutron Spectrometer (GRNS) instrument has been developed as part of the science payload for NASA’s Discovery Program Psyche mission to the M-class asteroid (16) Psyche. The GRNS instrument is designed to measure the elemental composition of Psyche with the goal to understand the origin of this mysterious, potentially metal-rich planetary body. The GRNS will measure the near-surface abundances for the elements Ni, Fe, Si, K, S, Al, and Ca, as well as the spatial distribution of Psyche’s metal-to-silicate fraction (or metal fraction). These measurements address three of the five Psyche mission science objectives: determine if Psyche is a core; determine whether small metal bodies incorporate light elements into the metal phase; and determine whether Psyche was formed under reducing conditions. The Gamma-Ray Spectrometer (GRS) uses a cryocooled, high-purity Ge (HPGe) sensor to detect cosmic-ray generated gamma rays in the 60 to 9000-keV energy range. The HPGe sensor is surrounded by a borated plastic anticoincidence shield that provides three functions: active background rejection from charged particle interactions in the HPGe sensor; fast neutron measurements; and direct measurements of the incident galactic cosmic ray flux. The Neutron Spectrometer (NS) uses three 3 He gas proportional sensors, each with different material wraps to measure thermal (<0.4 eV), low-energy epithermal (0.4 eV to 1 keV), and high-energy epithermal (up to 100 keV) neutrons. This paper provides an overview of the Psyche GRNS, including: its science and measurement objectives; the design of the instrument hardware, software, and operation; pre-launch performance measurements and its initial performance in space; and an overview of its data products and expected operation for different Psyche mission phases.

Engineering - Instrumentation related to nuclear s↗

Pseudo-equilibrium geometry of HNO determined by an E-Band CP-FTmmW spectrometer

An E-Band (60–90 GHz) chirped-pulse Fourier transform millimeter-wave spectrometer has been constructed for eventual kinetics and dynamics studies. The performance of the spectrometer is demonstrated with the molecule nitroxyl (HNO). Using the new spectrometer and by passing isotopically labelled methyl nitrite (CH 3 ONO) through a pyrolysis nozzle, the spectra of minor isotopologues of HNO have been obtained. The observations on the isotopologues identified here, H 15 NO, HN 18 O, and D 15 NO, have been combined with the earlier isotopic observations, HNO and DNO, to create a global r m (1) HNO geometry that approximates an equilibrium structure. Furthermore, the results are compared to high-level ab initio calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Erosion resistance test of SiC mirror sample for ITER divertor VUV spectrometer

A series of tests have been performed to validate the resistance of the Silicon Carbide (SiC) mirror as the first mirror material of ITER VUV spectrometers to all ITER environmental conditions. Here we focused on the erosion (and deposition) of the SiC mirror sample caused by high-energy neutral particles. The flux of neutral particles reaching the first mirror was calculated using the ZEMAX software with a simplified entrance duct model. In the calculation, the particle flux reaching the first wall is necessary and the previously reported values derived from the SOLPS calculations were used. Based on this estimated particle flux, the erosion resistance tests were performed to check the erosion effect due to the high-energy neutral particles on the first mirror of ITER divertor VUV spectrometer. In the experiment, erosion was induced by exposing the SiC mirror sample to hydrogen and deuterium plasmas (and ions). The target fluence of incident ions in experiment is based on the estimation of the flux of neutral particles in ITER. The surface shape, composition, erosion depth, and surface roughness were measured to check the damage of the mirror surface after erosion test. Based on simulations and erosion resistance tests, it was concluded that the SiC mirror can be used as the first mirror of ITER divertor VUV spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The lead-glass electromagnetic calorimeters for the magnetic spectrometers in Hall C at Jefferson Lab

The electromagnetic calorimeters of the various magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers design considerations, relevant construction information, and comparisons of simulated and experimental results are included. The energy resolution of the HMS and SOS calorimeters is better than $\sigma/E \sim 6%/\sqrt E $, and pion/electron ($\pi/e$) separation of about 100:1 has been achieved in energy range 1 -- 5 GeV. Good agreement has been observed between the experimental and simulated energy resolutions, but simulations systematically exceed experimentally determined $\pi^-$ suppression factors by close to a factor of two. For the SHMS spectrometer presently under construction details on the design and accompanying GEANT4 simulation efforts are given. The anticipated performance of the new calorimeter is predicted over the full momentum range of the SHMS. Good electron/hadron separation is anticipated by combining the energy deposited in an initial (preshower) calorimeter layer with the total energy deposited in the calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The aCORN backscatter-suppressed beta spectrometer

Backscatter of electrons from a beta detector, with incomplete energy deposition, can lead to undesirable effects in many types of experiments. We present and discuss the design and operation of a backscatter-suppressed beta spectrometer that was developed as part of a program to measure the electron–antineutrino correlation coefficient in neutron beta decay (aCORN). An array of backscatter veto detectors surrounds a plastic scintillator beta energy detector. The spectrometer contains an axial magnetic field gradient, so electrons are efficiently admitted but have a low probability for escaping back through the entrance after backscattering. Lastly, the design, construction, calibration, and performance of the spectrometer are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact light shield for the Psyche gamma-ray spectrometer

A compact, low-mass light shield has been designed for the Psyche space mission high-purity germanium gamma-ray spectrometer. The spectrometer will be vented to space, which can allow solar photons to enter the cryostat and cause charge-induced noise. The light shield was designed to block more than 99.9% of solar photons while maintaining high molecular conductance to space vacuum. COMSOL simulations and experiments were performed to characterize light shield photon attenuation and molecular conductance. Finally, the light shield was integrated onto the gamma-ray spectrometer and photon suppression and vacuum performance were demonstrated.

(16) Psyche↗

Ground calibration and in-flight commissioning of the Gamma-Ray and Neutron Spectrometer (GRNS) for NASA’s Psyche mission

NASA's Psyche spacecraft is currently enroute to the asteroid 16 Psyche, where it will perform an orbital investigation focused on determining the nature of the asteroid. A key part of this investigation is measurements of elemental composition to determine if the asteroid is rich in iron-nickel metal. To that end, the Psyche spacecraft payload includes a Gamma-Ray and Neutron Spectrometer (GRNS). GRNS is composed of two subsystems; a Gamma-Ray Spectrometer (GRS) with a high-purity germanium γ-ray sensor surrounded by a borated plastic scintillator Anti-Coincidence Shield (ACS), and a Neutron Spectrometer (NS) with three 3 He-filled gas proportional counters that are sensitive to different neutron energy regimes. We describe results from the pre-launch calibration campaign, along with early in-flight results from post-launch instrument commissioning. The information detailed here is focused on providing future users of GRNS data with the information needed to properly interpret the observations from the instrument.

Peplowski, Patrick N. [Johns Hopkins Univ., Baltim↗

The upgraded summing NaI(Tl) (SuN++) absorption spectrometer

Simulations of astrophysical processes require a plethora of nuclear physics input. In particular, models of neutron-capture nucleosynthesis like the s, i, and r processes require β-decay information and experimentally constrained neutron-capture reaction rates. Past experiments with the 4π Summing NaI(Tl) (SuN) total absorption spectrometer have provided these physics quantities. Here, we outline an upgrade of SuN to SuN++, where 20 new segments (12 NaI(Tl) and 8 CeBr 3 ) have been integrated into the pre-existing SuN total absorption spectrometer to provide increased energy and time resolution in β-decay experiments. The details of the newly upgraded SuN++ total absorption spectrometer are discussed with results from the commissioning experiment at the Facility for Rare Isotope Beams (FRIB) utilizing a 70 Cu beam.

CeBr3↗

On-chip spectrometers using stratified waveguide filters

We present an ultra-compact single-shot spectrometer on silicon platform for sparse spectrum reconstruction. It consists of 32 stratified waveguide filters (SWFs) with diverse transmission spectra for sampling the unknown spectrum of the input signal and a specially designed ultra-compact structure for splitting the incident signal into those 32 filters with low power imbalance. Each SWF has a footprint less than 1 µm × 30,µm, while the 1 × 32 splitter and 32 filters in total occupy an area of about 35 µm × 260 µm, which to the best of our knowledge, is the smallest footprint spectrometer realized on silicon photonic platform. Experimental characteristics of the fabricated spectrometer demonstrate a broad operating bandwidth of 180 nm centered at 1550 nm and narrowband peaks with 0.45 nm Full-Width-Half-Maximum (FWHM) can be clearly resolved. This concept can also be implemented using other material platforms for operation in optical spectral bands of interest for various applications.

42 ENGINEERING↗