Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectral mixture analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The diversity of aluminum-based drinking water treatment residuals for use in environmental remediation

Drinking water treatment residuals (DWTRs) are complex mixtures of organic and inorganic phases generally disposed of as waste materials. However, their strong sorptive properties could be further exploited to immobilize contaminants. To characterize these materials, we applied a range of analytical techniques to a set of aluminum-based DWTRs. Here we determined surface areas, elemental compositions using CHNS analysis and X-ray fluorescence (XRF), performed thermogravimetric analyses paired with mass spectrometry (TGA-MS), and used synchrotron-based methods: X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS). Elemental analyses and specific surface area measurements – that vary between 7.23 ± 0.03 and 197.6 ± 0.9 m 2 g –1 – indicate that non-coagulant additives must play an important role in controlling sorption. High resolution powder XRD reveals the presence of only a few crystalline minerals mostly derived from source waters or additives. Fe was detected by XRF in all samples, whereas Mn was present in significant levels in samples with potassium permanganate as additive. The chemical speciation of these elements was characterized by performing spectral decompositions of XAS spectra. The spectral features of Fe are consistent with iron(III) oxides/hydroxides and structural iron in clays. On the other hand, Mn is predominantly present under its reduced form, Mn(II).

54 ENVIRONMENTAL SCIENCES↗

Spectral Absorption of Solar Radiation by Aerosols during ACE-Asia

As part of the Asian Pacific Regional Aerosol Characterization Experiment (ACE-Asia), the upward and downward spectral solar radiant fluxes were measured with the Spectral Solar Flux Radiometer (SSFR), and the aerosol optical depth was measured with the Ames Airborne Tracking Sunphotometer (AATS-14) aboard the Center for INterdisciplinary Remotely-Piloted Aircraft Studies (CIRPAS) Twin Otter aircraft. IN this paper, we examine the data obtained for two cases: a moderately thick aerosol layer, 12 April, and a relatively thin aerosol case, 16 April 2001. ON both days, the Twin Otter flew vertical profiles in the Korean Strait southeast of Gosan Island. For both days we determine the aerosol spectral absorption of the layer and estimate the spectral aerosol absorption optical depth and single-scattering albedo. The results for 12 April show that the single-scattering albedo increases with wavelength from 0.8 at 400 nm to 0.95 at 900 nm and remains essentially constant from 950 to 1700 nm. On 16 April the amount of aerosol absorption was very low; however, the aerosol single-scattering albedo appears to decrease slightly with wavelength in the visible region. We interpret these results in light of the two absorbing aerosol species observed during the ACE-asia study: mineral dust and black carbon. The results for 12 April are indicative of a mineral dust-black carbon mixture. The 16 April results are possibly caused by black carbon mixed with nonabsorbing pollution aerosols. For the 12 April case we attempt to estimate the relative contributions of the black carbon particles and the mineral dust particles. We compare our results with other estimates of the aerosol properties from a Sea-Viewing Wide Field-of-View Sensor (SeaWiFS) satellite analysis and aerosol measurements made aboard the Twin Otter, aboard the National Oceanic and Atmospheric Administration Ronald H Brown ship, and at ground sites in Gosan and Japan. The results indicate a relatively complicated aerosol mixture of both industrial pollution (including black carbon) and mineral dust. This underscores the need for careful measurements and analysis to separate out the absorption effects of mineral dust and black carbon in the east Asia region.

Bergstrom, R. W.↗

A Machine Learning Framework for Error Compensation in Radiative Transfer Calculations

Radiative heat transfer influences the amount of heat flux transferred to the surface of the hypersonic vehicle, which is essential to evaluate the performance of thermal protection systems. The radiative heat flux is found to be computationally prohibitive while accounting for the variation in spatial, angular, and spectral domains. A new methodology has been recently developed to alleviate the cost of computation in the spectral domain by constructing flow-agnostic reduced-order models (ROMs). The developed spectral ROM databases provide grouping strategies that account for non-equilibrium absorption and emission as well as interaction between disparate species due to spectral overlap in associated radiative processes. However, the developed ROMs need to be optimized for a specific combination of interacting gas species and would need to re-calibrated in case individual species are added/omitted. In this work, we use various machine learning (ML) techniques to approximate the radiative intensities determined by a ROM optimized for a specific gas mixture. The ML model relies on the ROM databases developed for a single species which ignores any spectral overlap. Thus, radiation evaluation starts with a simple summation of radiative intensities predicted using these non-calibrated ROMs for the contributing species. The ML framework then provides a correction to account for the interplay in the frequency, i.e., emission of photons by one species and absorption by another, and yields mixture-specific radiation fields. Once trained on the individual ROM databases, the ML framework offers instantaneous corrections that serves as a time/cost effective alternative to the optimization of ROMs for a specific gas mixture. The ML framework is trained on both the high fidelity and ROM evaluated line of sight (LOS) data from Orion, Stardust, and FIRE II cases to obtain a general purpose correction model for earth re-entry scenarios when radiation contributions from both atomic nitrogen and atomic oxygen are considered. A geometric length scale parameter is used in the training process to account for errors introduced in the ROM databases as a consequence of high optical thickness. The efficacy of the ML framework is underscored through extensive analysis of train and test errors with respect to all the re-entry scenarios. The applicability of such an ML framework was further corroborated by embedding it in a state-of-the-art US3D - NERO system for determining the radiative heat flux transferred to the hypersonic vehicle surface.

Radiation↗

Passive acoustic leak detection for sodium cooled fast reactors using hidden Markov models

Acoustic leak detection for steam generators of sodium fast reactors have been an active research topic since the early 1970's and several methods have been tested over the years. Inspired by its success in the field of automatic speech recognition, we here apply hidden Markov models (HMM) in combination with Gaussian mixture models (GMM) to the problem. To achieve this, we propose a new feature calculation scheme, based on the temporal evolution of the power spectral density (PSD) of the signal. Using acoustic signals recorded during steam/water injection experiments done at the Indira Gandhi Centre for Atomic Research (IGCAR), the proposed method is tested. We perform parametric studies on the HMM+GMM model size and demonstrate that the proposed method a) performs well without a priori knowledge of injection noise, b) can incorporate several noise models and c) has an output distribution that simplifies false alarm rate control. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Spectral components of human cardiovascular responses to step changes in Lower Body Negative Pressure (LBNP) before and after 22 hour of 6 deg head down bed rest

Changes in autonomic outflow to peripheral organs during the development of bedrest induced orthostatic intolerance have not been determined. Recent studies have indicated that spectral analysis provides an indirect assessment of these changes. Eight male subjects were studied before and after 22 hours of 6 degree head down bedrest plus Lasix (40 mg. P.P.). Cardiovascular spectra (using an autoregressive technique) were determined for heart rate (HR, ECG), arterial pressure (AP, Finapres), radial artery flow (RF, Hokansen) and respiration rate (RR, BoMed). Spectra were obtained from 2.5 minute segments during control, lower body negative pressure (minus 10, 20, 30, 40, 50 mmHg) and recovery. Bedrest increased HR spectra power in the low frequency (.001 to .041 Hz) range, increased RF power in the low and mid (.04 to .18 Hz) range and increased AP power in the high (.18 to .50 Hz) frequency range. Increasing levels of lower body negative pressure decreased HR power and increased RF power in the high frequency range and decreased AP power in the low frequency range. Since spectral power of HR in the high frequency range has been shown to indicate parasympathetically mediated regulation and power in the low and mid frequency ranges indicates a sympathetic / parasympathetic mixture, then both bedrest and lower body negative pressure appeared to shift sympathetic / parasympathetic balance toward sympathetic regulation of HR. The interpretation of the spectral content of AP and RF with respect to their autonomic origins remains unclear.

Knapp, C. F.↗

HSRL-2 Observations of Aerosol Variability and Mixing During Boundary Layer Evolution in Houston

The NASA Langley airborne multi-wavelength High Spectral Resolution Lidar (HSRL-2) provides vertical distribution of aerosol optical properties as ?curtains? of aerosol extinction, backscatter and depolarization along the flight track, plus intensive properties that are used to infer aerosol type and external mixing of types. Deployed aboard the NASA Langley King Air on the DISCOVER-AQ field mission in Houston in September 2013, HSRL-2 flew a pattern that included 18 ground sites, repeated four times a day, coordinated with a suite of airborne in situ measurements. The horizontally and vertically resolved curtains of HSRL-2 measurements give an unparalleled view of the spatial and temporal variability of aerosol, which provide broad context for interpreting other measurements and models. In Houston, HSRL-2 generally observed significant variability with distinct layering: boundary layer, residual layer, and frequent upper layers of smoke transported from the Mississippi Valley. The period from Sep. 11-14 is notable for a large aerosol build-up and persistent layers in the free troposphere. We investigate the aerosol properties and evolution using the vertically resolved HSRL-2 measurements, typing and mixture analysis techniques, and boundary layer detection. Between morning and afternoon overpasses, as the boundary layer grows, many distinctions between the layers are lost as the aerosols become mixed. As the boundary layer collapses overnight, the aerosols are cut off and are observed in a distinct residual layer the following day. HSRL-2 measurements of the upper smoke layers suggest slightly different properties each day as new smoke enters the region, while the morning boundary layer indicates more similarity in local emissions day-to-day. HSRL-2 intensive variables (indicators of aerosol type) reflect complex yet predictable mixing. We will present the analysis of aerosol mixtures, and explore the WRF-Chem chemical transport model along the HSRL-2 flight path.

Sharon P Burton↗

Non-gray gas radiation effect on mixed convection in lid driven square cavity

A numerical study is performed to investigate the effect of non-gray radiation on mixed convection in a vertical two sided lid driven square cavity filled with air-H{sub 2}O-CO{sub 2} gas mixture. The vertical moving walls of the enclosure are maintained at two different but uniform temperatures. The horizontal walls are thermally insulated and considered as adiabatic walls. The governing differential equations are solved by a finite-volume method and the SIMPLE algorithm was adopted to solve the pressure–velocity coupling. The radiative transfer equation (RTE) is solved by the discrete ordinates method (DOM). The spectral line weighted sum of gray gases model (SLW) is used to account for non-gray radiation properties. Simulations are performed in configurations where thermal and shear forces induce cooperating buoyancy forces. Streamlines, isotherms, and Nusselt number are analyzed for three different values of Richardson’s number (from 0.1 to 10) and by considering three different medium (transparent medium, gray medium using the Planck mean absorption coefficient, and non-gray medium assumption).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-Assembled Light-Harvesting System from Chromophores in Lipid Vesicles

Lipid vesicles are used as the organizational structure of self-assembled light-harvesting systems. Following analysis of 17 chromophores, six were selected for inclusion in vesicle-based antennas. The complementary absorption features of the chromophores span the near-ultraviolet, visible, and near-infrared region. Although the overall concentration of the pigments is low (~1 μ M for quantitative spectroscopic studies) in a cuvette, the lipid-vesicle system affords high concentration (≥10 mM) in the bilayer for efficient energy flow from donor to acceptor. Energy transfer was characterized in 13 representative binary mixtures using static techniques (fluorescence–excitation versus absorptance spectra, quenching of donor fluorescence, modeling emission spectra of a mixture versus components) and time-resolved spectroscopy (fluorescence, ultrafast absorption). Binary donor–acceptor systems that employ a boron-dipyrrin donor (S 0 ↔ S 1 absorption/emission in the blue-green) and a chlorin or bacteriochlorin acceptor (S 0 ↔ S 1 absorption/emission in the red or near-infrared) have an average excitation-energy-transfer efficiency (Φ EET ) of ~50%. Binary systems with a chlorin donor and a chlorin or bacteriochlorin acceptor have Φ EET ~ 85%. The differences in Φ EET generally track the donor-fluorescence/acceptor-absorption spectral overlap within a dipole–dipole coupling (Förster) mechanism. Substantial deviation from single-exponential decay of the excited donor (due to the dispersion of donor–acceptor distances) is expected and observed. The time profiles and resulting Φ EET are modeled on the basis of (Förster) energy transfer between chromophores relatively densely packed in a two-dimensional compartment. Initial studies of two ternary and one quaternary combination of chromophores show the enhanced spectral coverage and energy-transfer efficacy expected on the basis of the binary systems. Collectively, this approach may provide one of the simplest designs for self-assembled light-harvesting systems that afford broad solar collection and efficient energy transfer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-D-204-01: Dual-Energy Calibration for Breast Density Measurement Using Spectral Mammography

Purpose: To investigate the feasibility of minimizing the systematic errors in dual-energy breast density quantification induced by the use of tissue-equivalent plastic phantoms as the calibration basis materials. Methods: Dual-energy calibration using tissue-equivalent plastic phantoms was performed on a spectral mammography system based on scanning multi-slit Si strip photon-counting detectors. The plastic phantom calibration used plastic water and adipose-equivalent phantoms as the basis materials, which have different x-ray attenuation properties compared to water and lipid in actual breast tissue. Two methods were used to convert the dual-energy decomposition measurements in plastic phantom thicknesses into true water and lipid basis. The first method was based entirely on the theoretical x-ray attenuation coefficients of the investigated materials in the mammographic energy range. The conversion matrix was determined from least-squares fitting of the target material using the reported attenuation coefficients of water and lipid. The second method was developed based on experimental calibrations, which measured the low-and high-energy signals of pure water and lipid of known thicknesses. A non-linear rational function was used to correlate the decomposed thicknesses to the known values, so that the conversion coefficients can be determined. Both methods were validated using independent measurements of water and lipid mixture phantoms. The correlation of the dual-energy decomposition measurements and the known values were studied with linear regression analysis. Results: There was an excellent linear correlation between the converted water thicknesses and the known values. The slopes of the linear fits were determined to be 0.63 and 1.03 for the simulation and experimental results, respectively. The non-linear fitting in the experimental approach reduced the root-mean-square (RMS) errors from approximately 3.4 mm to 1.5 mm. Conclusion: The results suggested that conversion of the dual-energy measurements into water and lipid thicknesses minimized the systematic errors in tissue decomposition studies.

60 APPLIED LIFE SCIENCES↗

SPECTROSCOPIC EFFECTS IN CH{sub 4}/H{sub 2}O ICES

Recent observations of CH{sub 4} in different astrophysical objects encourage laboratory research on methane/water ice mixtures. An IR spectroscopy laboratory investigation is presented on these systems. Co-deposited samples are formed by vapor deposition of CH{sub 4} and H{sub 2}O on a cold substrate, in a wide range of stoichiometries, from very diluted mixtures to CH{sub 4}/H{sub 2}O = 2.5 values. Samples are prepared at 14 K and at 40 K, and their temperature behavior is studied when they are warmed up to 60 K. The spectroscopic analysis is centered on the methane features, and also on the water dangling bonds (DBs) that appear in the spectra of the mixtures. The IR forbidden nu{sub 1} band shows up in the spectrum (3.44 {mu}m), indicating some form of distorted methane. The combination bands nu{sub 3} + nu{sub 4} and nu{sub 1} + nu{sub 4} are seen at 2.32 and 2.38 {mu}m, and the nu{sub 2} + nu{sub 3} band weakly at 2.21 {mu}m. Whereas nu{sub 3} is not shifted in spectra of mixed samples, the wavenumber peak of nu{sub 4} and its combination bands vary in a 6 cm{sup -1} range, providing a possible estimation for the relative methane concentration in the sample. Bands in the spectra of mixtures are always broader than their counterparts in pure CH{sub 4} ice. The intensity of nu{sub 4} appears to increase in mixed samples with respect to the pure solid. Raising the temperature of the ices up to 60 K liberates part of the methane, but a fraction is retained with a maximum value of approx7% +- 2%. This limit may provide information on the temperature properties of astrophysical objects. The different spectral characteristics of water DBs with increasing methane proportion in mixed samples can also furnish information to estimate the stoichiometry of the mixture.

79 ASTRONOMY AND ASTROPHYSICS↗

High-resolution rovibrational spectroscopy of trans -formic acid in the v 1 OH stretching fundamental: Dark state coupling and evidence for charge delocalization dynamics

High-resolution infrared (IR) reduced-Doppler absorption spectra of jet-cooled gas phase trans-formic acid in the v 1 OH stretching fundamental region are reported for the first time, obtained by supersonically expanding trans- formic acid/Ar mixtures through a slit jet nozzle source and rotationally cooling to T rot ≈ 10.9(5) K, with ab- sorption signals recorded by high-resolution difference-frequency IR absorption spectroscopy. Two a/b-type rovibrational bands of comparable intensity, one ~10-fold weaker b-type band, and one ~6-fold weaker a-type band are observed, with vibrational band origins at 3570.493(5), 3566.793(5), 3560.032(9), and 3534.6869(2) cm –1 , respectively. Based on previous Raman jet spectroscopic work by Nejad and Sibert [A. Nejad, E.L. Sibert III, The Raman jet spectrum of trans-formic acid and its deuterated isotopologs: Combining theory and experi- ment to extend the vibrational database, J. Chem. Phys. 154(6) (2021) 064301.], these four rovibrational bands have been assigned to v 1 , (v 2 + v 7 ), (v 6 + 2v 7 + 2v 9 ), and 2v 3 , respectively. Specifically, two of the three upper dark states (2 1 7 1 (a') and 6 1 7 2 9 2 (a')) are close enough to the “bright” 1 1 (a') state to facilitate strong anharmonic resonance interactions, which results in intensity mixing into the two zero-order bands that would otherwise be “dark”. Furthermore, our high-resolution spectral analysis reveals that there are local rotational crossings be- tween these zero-order 1 1 and 2 1 7 1 states resulting in extra lines (i.e., some upper levels in the nominally v 1 band have majority zero-order 2 1 7 1 state character). This motivates development of a 3 coupled state (1 1 , 2 1 7 1 , and 6 1 7 2 9 2 ) picture to aid in the spectral analysis, which is able to match all 3 observed band origins and relative band intensities, as well as indicate the necessity of multistate (> 2) coupling. Though limited by range of J and Ka levels (J’ ≤ 9 and K a ’ ≤ 3) populated at supersonic jet temperatures, this work offers first precision spec- troscopic analysis of trans-formic acid in the v 1 OH stretch region, which should aid in assignment of the more complete yet highly congested room temperature FTIR spectra. Lastly, and in sharp contrast to the spectral complexity in the three predominantly b-type bands, the lone a-type 2v 3 rovibrational band at 3534.6869(2) cm –1 is well described by a simple, rigid asymmetric top Hamiltonian.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Discrete models of fluids: spatial averaging, closure and model reduction

We consider semidiscrete ODE models of single-phase fluids and two-fluid mixtures. In the presence of multiple fine-scale heterogeneities, the size of these ODE systems can be very large. Spatial averaging is then a useful tool for reducing computational complexity of the problem. The averages satisfy exact balance equations of mass, momentum, and energy. These equations do not form a satisfactory continuum model because evaluation of stress and heat flux requires solving the underlying ODEs. To produce continuum equations that can be simulated without resolving microscale dynamics, we recently proposed a closure method based on the use of regularized deconvolution. Here we continue the investigation of deconvolution closure with the long term objective of developing consistent computational upscaling for multiphase particle methods. The structure of the fine-scale particle solvers is reminiscent of molecular dynamics. For this reason we use nonlinear averaging introduced for atomistic systems by Noll, Hardy, and Murdoch-Bedeaux. We also consider a simpler linear averaging originally developed in large eddy simulation of turbulence. We present several simple but representative examples of spatially averaged ODEs, where the closure error can be analyzed. Based on this analysis we suggest a general strategy for reducing the relative error of approximate closure. For problems with periodic highly oscillatory material parameters we propose a spectral boosting technique that augments the standard deconvolution and helps to correctly account for dispersion effects. We also conduct several numerical experiments, one of which is a complete mesoscale simulation of a stratified two-fluid flow in a channel. In this simulation, the operation count per coarse time step scales sublinearly with the number of particles.

Multiscale modeling, discrete models, fluid flow↗

Theoretical Basis for the Surface Spectral Reflectance Relationships Used in the MODIS Aerosol Algorithm

The analysis of data from the MODIS instrument on the Terra platform to derive global distribution of aerosols assumes a set of relationships between the blue, rho (sub blue), the red, rho (sub red), and 2.1 micrometers, rho (sub 2.1), spectral channels. These relations have been established from a series of measurements indicating that rho (sub blue) approximately 0.5 rho (sub red) approximately 0.25 rho (sub 2.1). Here we use a model to describe the transfer of radiation through a vegetation canopy composed of randomly oriented leaves to assess the theoretical foundations for these relationships. The influence of varying fractional vegetation coverage is simulated simply as a linear combination of pure soil and pure vegetation conditions, also known as Independent Pixel Approximation (IPA). Calculations for a wide range of leaf area indices and vegetation fractions show that rho (sub blue) is consistently about 1/4 of rho (sub 2.1) as used by MODIS for the whole range of analyzed cases, except for very dark soils, such as those found in burn scars. For its part, the ratio rho (sub red)/rho (sub 2.1) varies from less than the empirically derived value of 1/2 for dense and dark vegetation (rho (sub 2.1) less than 0.1), to more than 1/2 for bright mixture of soil and vegetation. This is in agreement with measurements over uniform dense vegetation, but not with measurements over mixed dark scenes. In the later case, the discrepancy is probably mitigated by shadows due to uneven canopy and terrain on a large scale. It is concluded that the value of this ratio should ideally be made dependent on the land cover type in the operational processing of MODIS data, especially over dense forests.

Kaufman, Yoram J.↗

Final Report – Cooperative Research and Development Agreement between National Energy Technology Laboratory and Solar Turbines Incorporated

The National Energy Technology Laboratory is developing the Raman Gas Analyzer (RGA) to be a fast, non-destructive instrument for on-line measurement of gas composition. The RGA prototype has been demonstrated to have an extremely fast response (<1 second) multi-gas analysis capability. All but the noble gases are Raman active, but Raman interaction is weak with gas phase substances. The RGA uses a reflectively lined capillary as the optical cell in a patented configuration, providing both a small sample volume for fast gas exchange, and a much greater Raman signal collection than traditional instrument configurations. This allows very fast measurement of fuel gases (hydrogen, methane, ethane, propane) as well as other common industrial gases (including CO, CO2, N2, O2, H2O). The RGA provides a new enabling technology for faster, smarter process control based on the chemical composition of the gases in the process, such as improving fuel flexibility and efficiency for power generation systems. NETL has constructed a field prototype of the RGA to test the instrument performance in various applications in fossil energy. Through this CRADA, the RGA prototype operation was tested using hydrocarbon mixtures and hydrogen on a combustor test rig for potential use in gas turbine engine testing. The testing was performed at the Solar Turbines Incorporated Harbor Drive facility in downtown San Diego, CA on December 3-7, 2018. The RGA was installed outside a combustor test bay, with a ¼" sample line connected from a point shortly upstream of the test combustor. The combustion test building online gas chromatograph reported analysis of a sample every 6 minutes. During testing, seven test conditions of pure gas or gas mixtures were supplied to a pressurized combustion test rig. A sample of the fuel gas was continuously analyzed using the RGA with a 1 second measurement and reporting time. For each test condition, once the steady condition was reached, the composition of the gas from the RGA measurements is reported, along with the expected composition from the flow meters, and the composition reported by the online gas chromatograph (GC). During this testing, the real-time measurement capability of the RGA was readily apparent. The composition changes occurring in real-time could be followed and observed to correspond to combustion behavior changes on the video monitor at the operator station. The largest concentration species were tracked well through the tests; however, from comparison of the RGA one-second data with the GC steady-state points, it appears the RGA had some difficulty with quantifying hydrocarbon mixtures, especially when some of the hydrocarbons were at low concentration. The difficulty was particularly noted for ethane and butane in these tests. The NETL team intends to address this in 2019. Moderate concentrations of nitrogen, carbon dioxide, and hydrogen (>10%) were readily observed in the spectral data and quantified closely to the GC measurements. While calibration data for propylene was collected in preparation for this testing, it was not observed during the testing, even when the test conditions had high concentrations of propane.

Source record↗

Lunar and Planetary Science XXXV: Missions and Instruments: Hopes and Hope Fulfilled

The titles in this section include: 1) Mars Global Surveyor Mars Orbiter Camera in the Extended Mission: The MOC Toolkit; 2) Mars Odyssey THEMIS-VIS Calibration; 3) Early Science Operations and Results from the ESA Mars Express Mission: Focus on Imaging and Spectral Mapping; 4) The Mars Express/NASA Project at JPL; 5) Beagle 2: Mission to Mars - Current Status; 6) The Beagle 2 Microscope; 7) Mars Environmental Chamber for Dynamic Dust Deposition and Statics Analysis; 8) Locating Targets for CRISM Based on Surface Morphology and Interpretation of THEMIS Data; 9) The Phoenix Mission to Mars; 10) First Studies of Possible Landing Sites for the Phoenix Mars Scout Mission Using the BMST; 11) The 2009 Mars Telecommunications Orbiter; 12) The Aurora Exploration Program - The ExoMars Mission; 13) Electron-induced Luminescence and X-Ray Spectrometer (ELXS) System Development; 14) Remote-Raman and Micro-Raman Studies of Solid CO2, CH4, Gas Hydrates and Ice; 15) The Compact Microimaging Spectrometer (CMIS): A New Tool for In-Situ Planetary Science; 16) Preliminary Results of a New Type of Surface Property Measurement Ideal for a Future Mars Rover Mission; 17) Electrodynamic Dust Shield for Solar Panels on Mars; 18) Sensor Web for Spatio-Temporal Monitoring of a Hydrological Environment; 19) Field Testing of an In-Situ Neutron Spectrometer for Planetary Exploration: First Results; 20) A Miniature Solid-State Spectrometer for Space Applications - Field Tests; 21) Application of Laser Induced Breakdown Spectroscopy (LIBS) to Mars Polar Exploration: LIBS Analysis of Water Ice and Water Ice/Soil Mixtures; 22) LIBS Analysis of Geological Samples at Low Pressures: Application to Mars, the Moon, and Asteroids; 23) In-Situ 1-D and 2-D Mapping of Soil Core and Rock Samples Using the LIBS Long Spark; 24) Rocks Analysis at Stand Off Distance by LIBS in Martian Conditions; 25) Evaluation of a Compact Spectrograph/Detection System for a LIBS Instrument for In-Situ and Stand-Off Detection; 26) Analysis of Organic Compounds in Mars Analog Samples; 27) Report of the Organic Contamination Science Steering Group; 28) The Water-Wheel IR (WIR) - A Contact Survey Experiment for Water and Carbonates on Mars; 29) Mid-IR Fiber Optic Probe for In Situ Water Detection and Characterization; 30) Effects of Subsurface Sampling & Processing on Martian Simulant Containing Varying Quantities of Water; 31) The Subsurface Ice Probe (SIPR): A Low-Power Thermal Probe for the Martian Polar Layered Deposits; 32) Deploying Ground Penetrating Radar in Planetary Analog Sites to Evaluate Potential Instrument Capabilities on Future Mars Missions; 33) Evaluation of Rock Powdering Methods to Obtain Fine-grained Samples for CHEMIN, a Combined XRD/XRF Instrument; 34) Novel Sample-handling Approach for XRD Analysis with Minimal Sample Preparation; 35) A New Celestial Navigation Method for Mars Landers; 36) Mars Mineral Spectroscopy Web Site: A Resource for Remote Planetary Spectroscopy.

Source record↗

Mimas: Preliminary Evidence For Amorphous Water Ice from VIMS

We have conducted a statistical clustering analysis (1,2) on a mosaic of VIMS data cubes obtained on February 13, 2010, for Saturn s satellite Mimas. Seven VIMS cubes were geometrically projected and re-sampled to a common spatial resolution. The clustering technique consists of a partitioning algorithm coupled to a criterion that prevents sub-optimal solutions and tests for the influence of random noise in the measurements. The clustering technique is agnostic about the meaning of the clusters, and scientific interpretation requires their a posteriori evaluation. The preliminary results yielded five clusters, demonstrating that spectral variability across Mimas surface is statistically significant. The ratios of the means calculated for each of the clusters show structure within the 1.6- micron water ice band, as well as the shape and the central wavelength of the strong ice band at 2 micron, that map spatially in patterns apparently related to the topography of Mimas, in particular certain regions in and around Herschel crater. The mean spectra of the five clusters, show similarities with laboratory spectra of amorphous and crystalline H2O ice (3) that are suggestive of the presence of an amorphous ice component in certain regions of Mimas, notably on the central peak of Herschel, on the crater floor, and in faults surrounding the crater. This may represent a mixture of both ice phases, or perhaps a layer of amorphous ice on a base of crystalline ice. Another possible occurrence of amorphous ice appears southwest of Herschel, close to the south pole.

Cruikshank, Dale P.↗

New Measurements of the Lyα Forest Continuum and Effective Optical Depth with LyCAN and DESI Y1 Data

Abstract We present the Ly α Continuum Analysis Network (LyCAN), a convolutional neural network that predicts the unabsorbed quasar continuum within the rest-frame wavelength range of 1040–1600 Å based on the red side of the Ly α emission line (1216–1600 Å). We developed synthetic spectra based on a Gaussian mixture model representation of nonnegative matrix factorization (NMF) coefficients. These coefficients were derived from high-resolution, low-redshift ( z < 0.2) Hubble Space Telescope/Cosmic Origins Spectrograph (COS) quasar spectra. We supplemented this COS-based synthetic sample with an equal number of DESI Year 5 mock spectra. LyCAN performs extremely well on testing sets, achieving a median error in the forest region of 1.5% on the DESI mock sample, 2.0% on the COS-based synthetic sample, and 4.1% on the original COS spectra. LyCAN outperforms principal component analysis (PCA) and NMF-based prediction methods using the same training set by 40% or more. We predict the intrinsic continua of 83,635 DESI Year 1 spectra in the redshift range of 2.1 ≤ z ≤ 4.2 and perform an absolute measurement of the evolution of the effective optical depth. This is the largest sample employed to measure the optical depth evolution to date. We fit a power law of the form τ ( z ) = τ 0 ( 1 + z ) γ to our measurements and find τ 0 = (2.46 ± 0.14) × 10 −3 and γ = 3.62 ± 0.04. Our results show particular agreement with high-resolution, ground-based observations around z = 2, indicating that LyCAN is able to predict the quasar continuum in the forest region with only spectral information outside the forest.

79 ASTRONOMY AND ASTROPHYSICS↗