Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Space walks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Frequency and velocity of rotational head perturbations during locomotion

The magnetic searth coil technique was used to record horizontal (yaw) and vertical (pitch) head rotations of 20 normal subjects during walking in place, running in place, vigorous voluntary horizontal head rotation, and vigorous voluntary vertical head rotation. Data are presented to show that (1) during locomotion, the head is stabilized in space incompletely but adequately so that the vestibuloocular reflex (VOR) is not saturated; (2) durign vigorous, voluntary head rotations, the maximum head velocity exceeds the range where the VOR can stabilize gaze; and (3) the frequencies of head rotations that occur during locomotion greatly exceed frequencies conventionally used in the laboratory for testing the VOR.

Grossman, G. E.↗

Strategies of Healthy Adults Walking on a Laterally Oscillating Treadmill

We mounted a treadmill on top of a six degree-of-freedom motion base platform to investigate locomotor responses produced by healthy adults introduced to a dynamic walking surface. The experiment examined self-selected strategies employed by participants when exposed to continuous, sinusoidal lateral motion of the support surface while walking. Torso translation and step width were used to classify responses used to stabilize gait in a novel, dynamic environment. Two response categories emerged. Participants tended to either fix themselves in space (FIS), allowing the treadbelt to move laterally beneath them, or they fixed themselves to the base (FTB), moving laterally as the motion base oscillated. The degree of fixation in both extremes varied across participants. This finding suggests that normal adults have innate and varied preferences for reacquiring gait stability, some depending more heavily on vision (FIS group) and others on proprioception (FTB group). Keywords: Human locomotion, Unstable surface, Treadmill, Adaptation, Stability

Brady, Rachel A.↗

2015 Sensorimotor Risk Standing Review Panel Evidence and Status Review For: the Risk of Impaired Control of Spacecraft/Associated Systems and Decreased Mobility Due to Vestibular/Sensorimotor Alterations Associated with Spaceflight

The 2015 Sensorimotor Risk Standing Review Panel (from here on referred to as the SRP) participated in a WebEx/teleconference with members of the Human Health Countermeasures (HHC) Element, representatives from the Human Research Program (HRP), NASA Headquarters, and NASA Research and Education Support Services (NRESS) on December 17, 2015 (list of participants is in Section VI of this report). The SRP reviewed the new Evidence Report for the Risk of Impaired Control of Spacecraft/Associated Systems and Decreased Mobility Due to Vestibular/Sensorimotor Alterations Associated with Spaceflight (from here on referred to as the 2015 Sensorimotor Evidence Report), and also received a status review of the Risk. The opening section of the 2015 Sensorimotor Evidence Report provides written descriptions of various incidents that have occurred during space missions. In most of these incidents, the main underlying contributing factors are not easy to identify unambiguously. For example, in section 1.9, a number of falls occurred while astronauts were walking on the moon. It is not clear to the SRP, however, why they fell. It is only possible to extrapolate from likely specific psychophysical or physiological abnormalities, but how these abnormalities were determined, and how they were directly responsible for the falls is unclear to the SRP. Section 2.1.2 on proprioception is very interesting, but the functional significance of the abnormalities detected is not clear. The SRP sees this as a problem throughout the report: a mapping between the component abnormalities identified and the holistic behaviors that are most relevant, for example, controlling the vehicle, and locomotion during egress, is generally lacking. The SRP thinks the cognitive section is too strongly focused on vestibular functioning. The SRP questions the notion that the main cognitive effects are mainly attributable to reversible vestibular changes induced by spaceflight. The SRP thinks that there can also be independent cognitive effects. The Functional Task Test (FTT) protocols and the Field Test are particularly valuable. The conclusion is that the unloading of major postural muscles experienced during spaceflight plays a central role in the alteration of functional task performance and balance control. This conclusion stands in contrast with the statements in other parts of the document that emphasize the role of vestibular changes on these functions. It would help to more fully integrate these two views on the predominant effects of spaceflight. Although the SRP thinks the countermeasures section is interesting, the proposed countermeasures are not well integrated with the abnormalities described in previous sections. The SRP thinks it would help enormously to have explicit links among each abnormality, its 2015 Sensorimotor Risk SRP Evidence Review Final Report 2 overall importance/impact on function, and the appropriate countermeasure that can be implemented to maintain adequate functioning.

Steinberg, Susan↗

STS-113 Post Flight Presentation

The STS-113 post-flight presentation begins with a view of Mission Specialists Michael E. Lopez-Alegria and John B. Herrington getting suited for the space mission. The STS-113 crew consists of: Commander James D. Wetherbee, Pilot Paul Lockhart, Mission Specialists Michael Lopez-Alegria and John Herrington. Cosmonauts Valery Korzun, and Sergei Treschev, and astronaut Peggy Whitson who are all members of the expedition five crew, and Commander Kenneth Bowersox, Flight Engineers Nikolai Budarin and Donald Pettit, members of Expedition Six. The main goal of this mission is to take Expedition Six up to the International Space Station and Return Expedition Five to the Earth. The second objective is to install the P(1) Truss segment. Three hours prior to launch, the crew of Expedition Six along with James Wetherbee, Paul Lockhart, Michael Lopez-Alegria and John Herrington are shown walking to an astrovan, which takes them to the launch pad. The actual liftoff is presented. Three Extravehicular Activities (EVA)'s are performed on this mission. Michael Lopez-Alegria and John Herrington are shown performing EVA 1 and EVA 2 which include making connections between the P1 and S(0) Truss segments, and installing fluid jumpers. A panoramic view of the ISS with the Earth in the background is shown. The grand ceremony of the crew exchange is presented. The astronauts performing everyday duties such as brushing teeth, washing hair, sleeping, and eating pistachio nuts are shown. The actual landing of the Space Shuttle is presented.

Source record↗

Preliminary Results from the Joint Russian and US Field Test: Measurement of Sensorimotor and Cardiovascular Responses Immediately Following Landing of the Soyuz Spacecraft

Ongoing collaborative research efforts between NASA's Neuroscience and Cardiovascular Laboratories, and the Institute of Biomedical Problems' (IBMP) Sensory-Motor and Countermeasures Laboratories have been measuring functional sensorimotor, cardiovascular and strength responses following bed rest, dry immersion, short duration (Space Shuttle) and long duration (Mir and International Space Station) space flights. While the unloading paradigms associated with dry immersion and bed rest have do serve as acceptable flight analogs, testing of crew responses following the long duration flights does not begin until a minimum of 24 hours after landing. As a result it is not possible to estimate the nonlinear trend of the early (<24 hr) recovery process nor is it possible to accurately assess the full impact of the decrements associated with long duration flight. To overcome these limitations both the Russian and U.S. sides have implemented testing at the time of landing and before the flight crews have left the landing site. By joint agreement this research effort has been identified as the functional Field Test (FT). For practical reasons the FT has been divided into two phases: the full FT and a preliminary pilot version (PFT) of the FT that is reduced in both length and scope. The primary goal of this research is to determine functional abilities in long duration space flight crews beginning as soon after landing as possible (< 2 hr) with one to three immediate follow-up measurements on the day of landing. This goal has both sensorimotor and cardiovascular elements including an evaluation of NASA's new anti-orthostatic compression garment as compared with the Russian Kentavr garment. Functional sensorimotor measurements will include, but are not limited to, assessment of hand/eye coordination, ability to egress from a seated position, walk normally without falling, measurement of dynamic visual acuity, ability to discriminate different forces generated with both the hands and legs, recovery from a fall, a coordinated walk involving tandem heel-to-toe placement and determination of postural ataxia while standing. The cardiovascular portion of the investigation includes blood pressure and heart rate measurements during a timed stand test in conjunction with postural ataxia testing. In addition to the immediate post-landing collection of data for the full FT, postflight data will be acquired at a minimum of one to three more other times within the 24 hr following landing and continue until functional sensorimotor and cardiovascular responses have returned to preflight normative values. The PFT represents a single trial run comprised of jointly agreed tests from the full FT and relies heavily on IBMP's Sensory-Motor and Countermeasures Laboratories for content, and implementation. The PFT is currently scheduled for the September 2013 landing of the Soyuz spacecraft (34S). Testing will include: (1) a sit-to-stand test, (2) recovery from a fall where the crewmember begins in the prone position on the ground and then stands for 3 min while cardiovascular stability is determined and postural ataxia data are acquired, and (3) a tandem heel-to-toe walk to determine changes in the central locomotor program. Video, cardiovascular parameters (heart rate and blood pressure), data from body-worn inertial sensors and severity of postflight motion sickness will be available for analysis. It is our intent to present, at this celebratory symposium, a summary of these data obtained from two crewmembers. In summary, the level of functional deficit is expected to be most profound during the acquisition of gravity loads immediately after landing when the demands for crew intervention in response to emergency operations will be greatest. Clearly measureable performance parameters such as ability to perform a seat egress, recover from a fall or the ability to see clearly when walking, and related physiological data (orthostatic responses) are required to provide an evidence base for characterizing programmatic risks and the degree of variability among crewmembers. Overall, these early functional and related physiological measurements will allow estimation of nonlinear sensorimotor and cardiovascular recovery trends to an accuracy that has not been previously captured in over 50 years of space flight.

Reschke, M. F.↗

Causal diamonds, cluster polytopes and scattering amplitudes

The “amplituhedron” for tree-level scattering amplitudes in the bi-adjoint φ 3 theory is given by the ABHY associahedron in kinematic space, which has been generalized to give a realization for all finite-type cluster algebra polytopes, labelled by Dynkin diagrams. In this letter we identify a simple physical origin for these polytopes, associated with an interesting (1 + 1)-dimensional causal structure in kinematic space, along with solutions to the wave equation in this kinematic “spacetime” with a natural positivity property. The notion of time evolution in this kinematic spacetime can be abstracted away to a certain “walk”, associated with any acyclic quiver, remarkably yielding a finite cluster polytope for the case of Dynkin quivers. The A n–3 , B n–1 /C n–1 and D n polytopes are the amplituhedra for n-point tree amplitudes, one-loop tadpole diagrams, and full integrand of one-loop amplitudes. We also introduce a polytope D¯ n , which chops the D n polytope in half along a symmetry plane, capturing one-loop amplitudes in a more efficient way.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Locomotion in a rotating environment

A rotating space station simulator is being used to obtain data on man's performance in a rotating environment. At present the facility is being used to assess the effects of rotation on man's walking capabilities on circular and flat walls at g-levels from 0.05 to 0.75g. Some of the preliminary results are reviewed.

Letko, W.↗

Design and Data Management System

The Design and Data Management System (DDMS) was developed to automate the NASA Engineering Order (EO) and Engineering Change Request (ECR) processes at the Propulsion Test Facilities at Stennis Space Center for efficient and effective Configuration Management (CM). Prior to the development of DDMS, the CM system was a manual, paper-based system that required an EO or ECR submitter to walk the changes through the acceptance process to obtain necessary approval signatures. This approval process could take up to two weeks, and was subject to a variety of human errors. The process also requires that the CM office make copies and distribute them to the Configuration Control Board members for review prior to meetings. At any point, there was a potential for an error or loss of the change records, meaning the configuration of record was not accurate. The new Web-based DDMS eliminates unnecessary copies, reduces the time needed to distribute the paperwork, reduces time to gain the necessary signatures, and prevents the variety of errors inherent in the previous manual system. After implementation of the DDMS, all EOs and ECRs can be automatically checked prior to submittal to ensure that the documentation is complete and accurate. Much of the configuration information can be documented in the DDMS through pull-down forms to ensure consistent entries by the engineers and technicians in the field. The software also can electronically route the documents through the signature process to obtain the necessary approvals needed for work authorization. The workflow of the system allows for backups and timestamps that determine the correct routing and completion of all required authorizations in a more timely manner, as well as assuring the quality and accuracy of the configuration documents.

Messer, Elizabeth↗

Quantum spatial search with multiple excitations

Spatial search is the problem of finding a marked vertex in a graph. A continuous-time quantum walk in the single-excitation subspace of an $n$ spin system solves the problem of spatial search by finding the marked vertex in $O(\sqrt{n})$ time. Here, we investigate a natural extension of the spatial search problem, marking multiple vertices of a graph, which are still marked with local fields. We prove that a continuous-time quantum walk in the $k$-excitation subspace of $n$ spins can determine the binary string of $k$ marked vertices with an asymptotic fidelity in time $O(\sqrt{n})$, despite the size of the state space growing as $O(n^k)$. Numerically, we show that this algorithm can be implemented with interactions that decay as $1/r^\alpha$, where $r$ is the distance between spins, and an $\alpha$ that is readily available in current ion trap systems.

Lewis, Dylan↗

Preliminary Sensorimotor and Cardiovascular Results from the Joint Russian/U.S. Pilot Field Test in Preparation for the Full Field Test

Ongoing collaborative research efforts between NASA's Neuroscience and Cardiovascular Laboratories, and the Institute of Biomedical Problems' (IBMP) Sensory-Motor and Countermeasures Laboratories have been measuring functional sensorimotor, cardiovascular and strength responses following bed rest, dry immersion, short-duration (Space Shuttle) and long-duration (Mir and International Space Station [ISS]) space flights. While the unloading paradigms associated with dry immersion and bed rest does serve as acceptable flight analogs, testing of crew responses following the long-duration flights previously has not been possible until a minimum of 24 hours after landing. As a result, it is not possible to estimate the nonlinear trend of the early (<24 hours) recovery process nor is it possible to accurately assess the full impact of the decrements associated with long-duration flight. To overcome these limitations, both the Russian and U.S. programs have implemented testing at the landing site. By joint agreement, this research effort has been identified as the functional Field Test (FT). For practical reasons the FT has been divided into two phases: the full FT and a preliminary pilot version (PFT) of the FT that is reduced in both length and scope. The primary goal of this research is to determine functional abilities in long-duration space-flight crews beginning as soon after landing as possible (< 2 hours) with one to three immediate follow-up measurements on the day of landing. This goal has both sensorimotor and cardiovascular elements, including evaluations of NASA's new anti-orthostatic compression garment and the Russian Kentavr garment. Functional sensorimotor measurements will include, but are not limited to, assessing hand/eye coordination, egressing from a seated position, walking normally without falling, measuring of dynamic visual acuity, discriminating different forces generated with both the hands and legs, recovering from a fall, coordinated walking involving tandem heel-to-toe placement, and determining postural ataxia while standing. The cardiovascular portion of the investigation includes measuring blood pressure and heart rate during a timed stand test in conjunction with postural ataxia testing (quiet stance sway) as well as cardiovascular responses during the other functional tasks. In addition to the immediate post-landing collection of data for the full FT, postflight data will be acquired between one and three more other times within the 24 hours after landing and will continue over the subsequent weeks until functional sensorimotor and cardiovascular responses have returned to preflight normative values. The PFT represents a single trial run comprised of a jointly agreed upon subset of tests from the full FT and relies heavily on IBMP's Sensory-Motor and Countermeasures Laboratories for content and implementation. The PFT has been collected on several ISS missions. Testing included: (1) a sit-to-stand test, (2) recovery from a fall where the crewmember began in the prone position on the ground and then stood for 3 minutes while cardiovascular stability was determined and postural ataxia data were acquired, and (3) a tandem heel-totoe walk test to determine changes in the central locomotor program. Video, cardiovascular parameters (heart rate and blood pressure), data from body-worn inertial sensors, and severity of postflight motion sickness were collected for each test session. In summary, the level of functional deficit is expected to be most profound during the acquisition of gravity loads immediately after landing when the demands for crew intervention in response to emergency operations will be greatest. Clearly measureable performance parameters such as ability to perform a seat egress, recover from a fall or the ability to see clearly when walking, and related physiologic data (orthostatic responses) are required to provide an evidence base for characterizing programmatic risks and the degree of variability among crewmembers for exploration missions where the crew will be unassisted after landing. Overall, these early functional and related physiologic measurements will allow estimation of nonlinear sensorimotor and cardiovascular recovery trends that has not been previously captured in over 50 years of space flight.

Reschke, M. F.↗

Zero-Gravity Locomotion Simulators: New Ground-Based Analogs for Microgravity Exercise Simulation

Maintaining health and fitness in crewmembers during space missions is essential for preserving performance for mission-critical tasks. NASA's Exercise Countermeasures Project (ECP) provides space exploration exercise hardware and monitoring requirements that lead to devices that are reliable, meet medical, vehicle, and habitat constraints, and use minimal vehicle and crew resources. ECP will also develop and validate efficient exercise prescriptions that minimize daily time needed for completion of exercise yet maximize performance for mission activities. In meeting these mission goals, NASA Glenn Research Center (Cleveland, OH, USA), in collaboration with the Cleveland Clinic (Cleveland, Ohio, USA), has developed a suite of zero-gravity locomotion simulators and associated technologies to address the need for ground-based test analog capability for simulating in-flight (microgravity) and surface (partial-gravity) exercise to advance the health and safety of astronaut crews and the next generation of space explorers. Various research areas can be explored. These include improving crew comfort during exercise, and understanding joint kinematics and muscle activation pattern differences relative to external loading mechanisms. In addition, exercise protocol and hardware optimization can be investigated, along with characterizing system dynamic response and the physiological demand associated with advanced exercise device concepts and performance of critical mission tasks for Exploration class missions. Three zero-gravity locomotion simulators are currently in use and the research focus for each will be presented. All of the devices are based on a supine subject suspension system, which simulates a reduced gravity environment by completely or partially offloading the weight of the exercising test subject s body. A platform for mounting treadmill is positioned perpendicularly to the test subject. The Cleveland Clinic Zero-g Locomotion Simulator (ZLS) utilizes a pneumatic subject load device to apply a near constant gravity-replacement load to the test subject during exercise, and is currently used in conjunction with the General Clinical Research Center for evaluating exercise protocols using a bedrest analog. The enhanced ZLS (eZLS) at NASA Glenn Research Center features an offloaded treadmill that floats on a thin film of air and interfaces to a force reaction frame via variably-compliant isolators, or vibration isolation system. The isolators can be configured to simulate compliant interfaces to the vehicle, which affects mechanical loading to crewmembers during exercise, and has been used to validate system dynamic models for new countermeasures equipment designs, such as the second International Space Station treadmill slated for use in 2010. In the eZLS, the test subject and exercise device can be pitched at the appropriate angle for partial gravity simulations, such as lunar gravity (1/6th earth gravity). On both the eZLS and the NASA-Johnson Space Center standalone ZLS installed at the University of Texas Medical Branch in Galveston, Texas, USA, the subject's body weight relative to the treadmill is controlled via a linear motor subject load device (LM-SLD). The LM-SLD employs a force-feedback closed-loop control system to provide a relatively constant force to the test subject during locomotion, and is set and verified for subject safety prior to each session. Locomotion data were collected during parabolic flight and on the eZLS. The purpose was to determine the similarities and differences between locomotion in actual and simulated microgravity. Subjects attained greater amounts of hip flexion during walking and running during parabolic flight. During running, subjects had greater hip range of motion. Trunk motion was significantly less on the eZLS than during parabolic flight. Peak impact forces, loading rate, and impulse were greater on the eZLS than during parabolic while walking with a low external load (EL) and rning with a high EL. Activation timing differences existed between locations in all muscles except for the rectus femoris. The tibialis anterior and gluteus maximus were active for longer durations on the eZLS than in parabolic flight during walking. Ground reaction forces were greater with the LM-SLD than with bungees during eZLS locomotion. While the eZLS serves as a ground-based analog, researchers should be aware that subtle, but measurable, differences in kinematics and leg musculature activities exist between the environments. Aside from space applications, zero-gravity locomotion simulators may help medical researchers in the future with development of rehabilitative or therapeutic protocols for injured or ill patients. Zero-gravity locomotion simulators may be used as a ground-based test bed to support future missions for space exploration, and eventually may be used to simulate planetary locomotion in partial gravity environments, including the Moon and Mars. Figure: Zero-gravity Locomotion Simulator at the Cleveland Clinic, Cleveland, Ohio, USA

Perusek, Gail P.↗

Grassmannian Diffusion Maps--Based Dimension Reduction and Classification for High-Dimensional Data

This work introduces the Grassmannian diffusion maps (GDMaps), a novel nonlinear dimensionality reduction technique that defines the affinity between points through their representation as low-dimensional subspaces corresponding to points on the Grassmann manifold. Here, the method is designed for applications, such as image recognition and data-based classification of constrained high-dimensional data where each data point itself is a high-dimensional object (i.e., a large matrix) that can be compactly represented in a lower-dimensional subspace. The GDMaps is composed of two stages. The first is a pointwise linear dimensionality reduction wherein each high-dimensional object is mapped onto the Grassmann manifold representing the low-dimensional subspace on which it resides. The second stage is a multipoint nonlinear kernel-based dimension reduction using diffusion maps to identify the subspace structure of the points on the Grassmann manifold. To this end, an appropriate Grassmannian kernel is used to construct the transition matrix of a random walk on a graph connecting points on the Grassmann manifold. Spectral analysis of the transition matrix yields low-dimensional Grassmannian diffusion coordinates embedding the data into a low-dimensional reproducing kernel Hilbert space. Further, a novel data classification/recognition technique is developed based on the construction of an overcomplete dictionary of reduced dimension whose atoms are given by the Grassmannian diffusion coordinates. Three examples are considered. First, a "toy" example shows that the GDMaps can identify an appropriate parametrization of structured points on the unit sphere. The second example demonstrates the ability of the GDMaps to revealing the intrinsic subspace structure of high-dimensional random field data. In the last ex- ample, a face recognition problem is solved considering face images subject to varying illumination conditions, changes in face expressions, and occurrence of occlusions. The technique presented high recognition rates (i.e., 95% in the best case) using a fraction of the data required by conventional methods.

42 ENGINEERING↗

Interoperable Services to Mitigate Lunar Position, Navigation, and Timing Challenges

Across the Earth, both civilian and government endeavors enjoy a built-in reliance on a position, navigation, and timing (PNT) infrastructure to which they are largely blind. Whether walking, driving, flying, or orbiting, Earth-centric PNT systems that have evolved over decades provide a core functionality to which we have grown accustomed for these pursuits. As NASA joins with other government space agencies and commercial partners to return humans to the Moon in a sustained manner within the current decade, expectations for PNT knowledge and timeliness at the Moon rival those on Earth. The need exists to develop a viable lunar-centric PNT infrastructure to support the planned human and robotic exploits. Navigating within the influence of the Moon presents its own set of challenges. Identification, understanding, and use of a unified reference frame and time system on which navigation is based becomes a fundamental need at the Moon. In addition to the unified foundational elements, measurement liability, dynamic conditions that require Earth-independent autonomous operations, and standards for PNT signals and message-based data exchange each represent distinct challenges to navigation in a burgeoning operational lunar environment. The PNT services planned as part of the lunar communications and navigation relay architecture known as LunaNet aid in surmounting the challenges. LunaNet interoperability specifications stipulate standards for signal parameters, messages, and lunar reference systems for PNT services. Within LunaNet’s defined interoperability resides the concept of a Reference Signal to provide communication signals specifically structured to enable measurement of pseudorange, Doppler, and time transfer by the recipient. One such signal type, the Augmented Forward Signal (AFS), functions as the mainstay for LunaNet PNT, while also serving the data needs for ubiquitous broadcast of network access and rapid unscheduled dissemination of alerts and messages. The presence of a geometrically distributed network of orbiting nodes transmitting the AFS forms the basis for the Lunar Augmented Navigation System (LANS), that delivers both radio navigation and data to multiple users in the lunar environment simultaneously. After reviewing the challenges associated with lunar navigation, this paper will describe the concepts and rationale behind the LunaNet PNT services. By borrowing techniques from Earth-centric Global Navigation Satellite Services (GNSS), the Tracking and Data Relay Satellite System, and the Consultative Committee for Space Data Standards, PNT from LunaNet aids to overcome challenges faced for accurate lunar navigation.

LunaNet↗

Interoperable Services to Mitigate Lunar Position, Navigation, and Timing Challenges

Across the Earth, both civilian and government endeavors enjoy a built-in reliance on a position, navigation, and timing (PNT) infrastructure to which they are largely blind. Whether walking, driving, flying, or orbiting, Earth-centric PNT systems that have evolved over decades provide a core functionality to which we have grown accustomed for these pursuits. As NASA joins with other government space agencies and commercial partners to return humans to the Moon in a sustained manner within the current decade, expectations for PNT knowledge and timeliness at the Moon rival those on Earth. The need exists to develop a viable lunar-centric PNT infrastructure to support the planned human and robotic exploits. Navigating within the influence of the Moon presents its own set of challenges. Identification, understanding, and use of a unified reference frame and time system on which navigation is based becomes a fundamental need at the Moon. In addition to the unified foundational elements, measurement liability, dynamic conditions that require Earth-independent autonomous operations, and standards for PNT signals and message-based data exchange each represent distinct challenges to navigation in a burgeoning operational lunar environment. The PNT services planned as part of the lunar communications and navigation relay architecture known as LunaNet aid in surmounting the challenges. LunaNet interoperability specifications stipulate standards for signal parameters, messages, and lunar reference systems for PNT services. Within LunaNet’s defined interoperability resides the concept of a Reference Signal to provide communication signals specifically structured to enable measurement of pseudorange, Doppler, and time transfer by the recipient. One such signal type, the Augmented Forward Signal (AFS), functions as the mainstay for LunaNet PNT, while also serving the data needs for ubiquitous broadcast of network access and rapid unscheduled dissemination of alerts and messages. The presence of a geometrically distributed network of orbiting nodes transmitting the AFS forms the basis for the Lunar Augmented Navigation System (LANS), that delivers both radio navigation and data to multiple users in the lunar environment simultaneously. After reviewing the challenges associated with lunar navigation, this paper will describe the concepts and rationale behind the LunaNet PNT services. By borrowing techniques from Earth-centric Global Navigation Satellite Services (GNSS), the Tracking and Data Relay Satellite System, and the Consultative Committee for Space Data Standards, PNT from LunaNet aids to overcome challenges faced for accurate lunar navigation.

Navigation↗

An Engineer, an Architect, and an Anthropologist Walk into a Conference Room...

Ethnographers are urged to "be there", in the field, in order to gain insight about a particular culture. When the field is unreachable, or does not yet exist, the applied anthropologist must adapt their methods accordingly while maintaining the integrity of their research. The space industry presents a unique case study for such a dilemma. Drawing on Bourdieu's 1977 reflection on the structural constraints and the forming of unconscious schemes of thought imposed by the material world on the body, this paper considers the effect of the presence and absence of place in applied, collaborative anthropological work.

Aiken, Jo↗

Benefits of a Single-Person Spacecraft for Weightless Operations

Historically, less than 20 percent of crew time related to extravehicular activity (EVA) is spent on productive external work.1 A single-person spacecraft with 90 percent efficiency provides productive new capabilities for maintaining the International Space Station (ISS), exploring asteroids, and servicing telescopes or satellites. With suits, going outside to inspect, service or repair a spacecraft is time-consuming, requiring pre-breathe time, donning a fitted space suit, and pumping down an airlock. For ISS, this is between 12.5 and 16 hours for each EVA, not including translation and work-site set up. The work is physically demanding requiring a day of rest between EVAs and often results in suit-induced trauma with frequent injury to astronauts fingers2. For maximum mobility, suits use a low pressure, pure oxygen atmosphere. This represents a fire hazard and requires pre-breathing to reduce the risk of decompression sickness (bends). With virtually no gravity, humans exploring asteroids cannot use legs for walking. The Manned Maneuvering Unit offers a propulsive alternative however it is no longer in NASA s flight inventory. FlexCraft is a single person spacecraft operating at the same cabin atmosphere as its host so there is no risk of the bends and no pre-breathing. This allows rapid, any-time access to space for repeated short or long EVAs by different astronauts. Integrated propulsion eliminates hand-over-hand translation or having another crew member operate the robotic arm. The one-size-fits-all FlexCraft interior eliminates the suit part inventory and crew time required to fit all astronauts. With a shirtsleeve cockpit, conventional displays and controls are used and because the work is not strenuous no rest days are required. Furthermore, there is no need for hand tools because manipulators are equipped with force multiplying end-effectors that can deliver the precise torque for the job.

Griffin, Brand N.↗

Preliminary Sensorimotor and Cardiovascular Results from the Joint Russian and U.S. Pilot Field Test with Planning for the Full Field Test Beginning with the Year Long Intenational Space Station

Ongoing collaborative research efforts between NASA's Neuroscience and Cardiovascular Laboratories, and the Institute of Biomedical Problems' (IBMP) Sensory-Motor and Countermeasures Laboratories have been measuring functional sensorimotor, cardiovascular and strength responses following bed rest, dry immersion, short duration (Space Shuttle) and long duration (Mir and International Space Station) space flights. While the unloading paradigms associated with dry immersion and bed rest does serve as acceptable flight analogs, testing of crew responses following the long duration flights previously has not been possible until a minimum of 24 hours after landing. As a result, it is not possible to estimate the nonlinear trend of the early (<24 hr) recovery process, nor is it possible to accurately assess the full impact of the decrements associated with long duration flight. To overcome these limitations, both the Russian and U.S. sides have implemented testing at landing site. By joint agreement, this research effort has been identified as the functional Field Test (FT). For practical reasons the FT has been divided into two phases: the full FT and a preliminary pilot version (PFT) of the FT that is reduced in both length and scope. The primary goal of this research is to determine functional abilities in long duration space flight crews beginning as soon after landing as possible (< 2 hr) with one to three immediate follow-up measurements on the day of landing. This goal has both sensorimotor and cardiovascular elements, including evaluations of NASA's new anti-orthostatic compression garment and the Russian Kentavr garment. Functional sensorimotor measurements will include, but are not limited to, assessment of hand/eye coordination, ability to egress from a seated position, walk normally without falling, measurement of dynamic visual acuity, ability to discriminate different forces generated with both the hands and legs, recovery from a fall, a coordinated walk involving tandem heel-to-toe placement, and determination of postural ataxia while standing. The cardiovascular portion of the investigation includes blood pressure and heart rate measurements during a timed stand test in conjunction with postural ataxia testing (quiet stance sway) as well as cardiovascular responses during other functional tasks. In addition to the immediate post-landing collection of data for the full FT, postflight data will be acquired at a minimum of one to three more other times within the 24 hr following landing and continue until functional sensorimotor and cardiovascular responses have returned to preflight normative values. The PFT represents a single trial run comprised of jointly agreed upon subset of tests from the full FT and relies heavily on IBMP's Sensory-Motor and Countermeasures Laboratories for content and implementation. The PFT was first conducted following the September 2013 landing of the Soyuz spacecraft (34S) and again following the landing of Soyuz 35S in November. Testing included: (1) a sit-tostand test, (2) recovery from a fall where the crewmember began in the prone position on the ground and then stood for 3 min while cardiovascular stability was determined and postural ataxia data were acquired, and (3) a tandem heel-to-toe walk test to determine changes in the central locomotor program. Video, cardiovascular parameters (heart rate and blood pressure), data from body-worn inertial sensors and severity of postflight motion sickness were collected for analysis. In summary, the level of functional deficit is expected to be most profound during the acquisition of gravity loads immediately after landing when the demands for crew intervention in response to emergency operations will be greatest. Clearly measureable performance parameters such as ability to perform a seat egress, recover from a fall or the ability to see clearly when walking, and related physiological data (orthostatic responses) are required to provide an evidence base for characterizing programmatic risks and the degree of variability among crewmembers for exploration missions where the crew will be unassisted after landing. Overall, these early functional and related physiological measurements will allow estimation of nonlinear sensorimotor and cardiovascular recovery trends to an accuracy that has not been previously captured in over 50 years of space flight.

Reschke, M. F.↗

Simulated Shuttle Egress: Comparison of Two Space Shuttle Protective Garments

In a previous study from our laboratory, we observed carbon dioxide (CO2) accumulation in the helmet of the NASA Launch and Entry Suit (LES) during a simulated emergency egress from the Space Shuttle. Eight of 12 subjects were unable to complete the egress simulation with a G-suit inflation pressure of 1.5 psi. The purpose of this report was to compare CO2 accumulation and egress walking time in the new Advanced Crew Escape Suit (ACES) with that in the LES.

Lee, Stuart M.C.↗