Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Software errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A software environment for effective reliability management for pulsed power design

The reliable design of magnetically insulated transmission lines (MITLs) for very high current pulsed power machines must be accomplished in the future by utilizing a variety of sophisticated modeling tools. The complexity of the models required is high and the number of sub-models and approximations large. The potential for significant analyst error using a single tool is large, with possible reliability issues associated with the plasma modeling tools themselves or the chosen approach by the analyst to solve a given problem. Here, we report on a software infrastructure design that provides a workable framework for building self-consistent models and constraining feedback to limit analyst error. The framework and associated tools aid the development of physical intuition, the development of increasingly sophisticated models, and the comparison of performance results. The work lays the computational foundation for designing state-of-the-art pulsed-power experiments. The design and useful features of this environment are described. We discuss the utility of the Git source code management system and a GitLab interface for use in project management that extends beyond software development tasks.

42 ENGINEERING↗

MO-FG-202-01: A Fast Yet Sensitive EPID-Based Real-Time Treatment Verification System

Purpose: To create a real-time EPID-based treatment verification system which robustly detects treatment delivery and patient attenuation variations. Methods: Treatment plan DICOM files sent to the record-and-verify system are captured and utilized to predict EPID images for each planned control point using a modified GPU-based digitally reconstructed radiograph algorithm which accounts for the patient attenuation, source energy fluence, source size effects, and MLC attenuation. The DICOM and predicted images are utilized by our C++ treatment verification software which compares EPID acquired 1024×768 resolution frames acquired at ∼8.5hz from Varian Truebeam™ system. To maximize detection sensitivity, image comparisons determine (1) if radiation exists outside of the desired treatment field; (2) if radiation is lacking inside the treatment field; (3) if translations, rotations, and magnifications of the image are within tolerance. Acquisition was tested with known test fields and prior patient fields. Error detection was tested in real-time and utilizing images acquired during treatment with another system. Results: The computational time of the prediction algorithms, for a patient plan with 350 control points and 60×60×42cm^3 CT volume, is 2–3minutes on CPU and <27 seconds on GPU for 1024×768 images. The verification software requires a maximum of ∼9ms and ∼19ms for 512×384 and 1024×768 resolution images, respectively, to perform image analysis and dosimetric validations. Typical variations in geometric parameters between reference and the measured images are 0.32°for gantry rotation, 1.006 for scaling factor, and 0.67mm for translation. For excess out-of-field/missing in-field fluence, with masks extending 1mm (at isocenter) from the detected aperture edge, the average total in-field area missing EPID fluence was 1.5mm2 the out-of-field excess EPID fluence was 8mm^2, both below error tolerances. Conclusion: A real-time verification software, with EPID images prediction algorithm, was developed. The system is capable of performing verifications between frames acquisitions and identifying source(s) of any out-of-tolerance variations. This work was supported in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

THE EFFECT OF STARSPOTS ON ACCURATE RADIUS DETERMINATION OF THE LOW-MASS DOUBLE-LINED ECLIPSING BINARY GU Boo

GU Boo is one of only a relatively small number of well-studied double-lined eclipsing binaries that contain low-mass stars. Lopez-Morales and Ribas present a comprehensive analysis of multi-color light and radial velocity curves for this system. The GU Boo light curves presented by Lopez-Morales and Ribas had substantial asymmetries, which were attributed to large spots. In spite of the asymmetry, Lopez-Morales and Ribas derived masses and radii accurate to {approx_equal}2%. We obtained additional photometry of GU Boo using both a CCD and a single-channel photometer and modeled the light curves with the ELC software to determine if the large spots in the light curves give rise to systematic errors at the few percent level. We also modeled the original light curves from the work of Lopez-Morales and Ribas using models with and without spots. We derived a radius of the primary of 0.6329 +- 0.0026 R{sub sun}, 0.6413 +- 0.0049 R{sub sun}, and 0.6373 +- 0.0029 R{sub sun} from the CCD, photoelectric, and Lopez-Morales and Ribas data, respectively. Each of these measurements agrees with the value reported by Lopez-Morales and Ribas (R{sub 1} = 0.623 +- 0.016 R{sub sun}) at the level of {approx}2%. In addition, the spread in these values is {approx}1%-2% from the mean. For the secondary, we derive radii of 0.6074 +- 0.0035 R{sub sun}, 0.5944 +- 0.0069 R{sub sun}, and 0.5976 +- 0.0059 R{sub sun} from the three respective data sets. The Lopez-Morales and Ribas value is R{sub 2} = 0.620 +- 0.020 R{sub sun}, which is {approx}2%-3% larger than each of the three values we found. The spread in these values is {approx}2% from the mean. The systematic difference between our three determinations of the secondary radius and that of Lopez-Morales and Ribas might be attributed to differences in the modeling process and codes used. Our own fits suggest that, for GU Boo at least, using accurate spot modeling of a single set of multi-color light curves results in radii determinations accurate at the {approx}2% level.

79 ASTRONOMY AND ASTROPHYSICS↗

Virtual strain gage size study

DIC is a non-linear low-pass spatial filtering operation; whether we consider the effect of the subset and shape function, the strain window used in the strain calculation, of other post-processing of the results, each decision will impact the spatial resolution, of the measurement. More fundamentally, the speckle size limits, the spatial resolution by dictating the smallest possible subset. After this decision the processing settings are controlled by the allowable noise level balanced by possible bias errors created by the data filtering. This article describes a process to determine optimum DIC software settings to determine if the peak displacements or strains are being found.

97 MATHEMATICS AND COMPUTING↗

AutoUncertainties: A Python Package for Uncertainty Propagation

Propagation of uncertainties is of great utility in the experimental sciences. While the rules of (linear) uncertainty propagation are straightforward, managing many variables with uncertainty information can quickly become complicated in large scientific software stacks. Often, this requires programmers to keep track of many variables and implement custom error propagation rules for each mathematical operator and function. The Python package AutoUncertainties, described here, provides a solution to this problem.

97 MATHEMATICS AND COMPUTING↗

A Mesh-Free Method to Predictively Simulate Solid-to-Liquid Phase Transitions in Abnormal Thermal Environments

Particle methods in computational physics are useful for modeling the motion of fluids and solids subject to large deformations. Under these conditions, mesh-based approaches often fail due to decreasing element quality leading to inaccuracy and instability. The developed software package called Moab investigates and prototypes next-generation particle methods, focusing on rigorous error analysis and active error minimization strategies during the computation. The present work discusses examples calculations representative of real engineering problems with quantified and maximized accuracy while demonstrating the potential for meeting engineering performance requirements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Runtime Verification Framework for Control System Simulation

n a standard workflow for the validation of a control system, the control system is implemented as an extension to a simulator. Such simulators are complex software systems, and engineers may unknowingly violate constraints a simulator places on extensions. As such, errors may be introduced in the implementation of either the control system or the simulator leading to invalid simulation results. This paper presents a novel runtime verification approach for verifying control system implementations within simulators. The major contribution of the approach is the two-tier specification process. In the first tier, engineers model constraints using a domain-specific language tailored to modeling a controller’s response to changes in its input. The language is high-level and effectively hides the implementation details of the simulator, allowing engineers to specify design-level constraints independent of low-level simulator interfaces. In the second tier, simulator developers provide mapping rules for mapping design-level constraints to the implementation of the simulator. Using the rules, an automated tool transforms the design-level specifications into simulator-specific runtime verification specifications and generates monitoring code which is injected into the implementation of the simulator. During simulation, these monitors observe the input and output variables of the control system and report changes to the verifier. The verifier checks whether these changes follow the constraints of the control system. We describe application of this approach to the verification of the constraints of an HVAC control system implemented with the power grid simulator GridLAB-D.

control system↗

Validation of the Modelling of Corrosion Driven Expansion in Grouted Waste-forms - 16125

One of the current preferred solutions for the disposal of Intermediate Level radioactive waste in the UK is grout encapsulation inside steel boxes for long term storage. These boxes are then to be entombed in a Geological Disposal Facility once one is available. However, both prior to and during geological disposal, waste contents can react with the water present in the encapsulant grout and begin to corrode. This corrosion product occupies a larger volume (by several hundred percent) than the original material and the corrosion occurs over the course of decades and centuries, long after the encapsulant grout has set and hardened. The expanding waste then creates stresses in the encapsulant causing both it and the surrounding box to deform and, in extreme circumstances, and after long times, for the structural integrity of the box to fail. This behaviour needs to be quantified before the box can be approved for use as any excessive deformation could lead to a loss of containment or, since the boxes are stacked on top of each other, to a significant accident in the stores. Due to the long timescales involved, physical testing of the phenomenon in full scale is impossible. Instead, a combination of chemical modelling and finite element analysis is used to predict the extent of the corrosion in the waste and its effect of the integrity of the box. There are a number of difficulties in modelling the corrosion-driven expansion and subsequent deformation of the boxes. Although the corrosion occurs over a very long time scale, the event is highly non-linear and dynamic. All of the material models, including the steel and grout are non-linear. The deformation is in the order of 10s of centimetres, well beyond the static elastic range. Finally, the components must be allowed to move relative to each other which involve a lot of part to part contacts. This means that simple static modelling, which would solve quite quickly, cannot be used. Instead a dynamic analysis code, LS-DYNA, has been used to expand the product over time to simulate the corrosion-driven expansion. This software is generally used for modelling car crashes or scenarios where waste containers have been dropped. The analyses therefore include a significant inertial component. This paper will detail the NNL's approach to modelling this long-term, quasi-static phenomenon in the dynamic, impact oriented software code LS-DYNA. It will cover the problems inherent in this approach, the errors that it creates as well as the tests and solutions that NNL worked on in order to overcome them and be confident that the solution could be validated. This work will ultimately be used to determine the maximum inventory which can be stored in each box based on the waste content and the potential extent of expansion as well as any modification that could be made to the box design or the processing streams that may improve the storage solution. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Beowulf - Beta-Gamma Detector Calibration Graphical User Interface

Pacific Northwest National Laboratory (PNNL) has demonstrated significant advancement in using beta-gamma coincidence detectors to detect a wide range of radioxenon isotopes. To obtain accurate activities with the detector it must be properly calibrated by measuring a series of calibration gas samples. The data is analyzed to create the calibration block used in the International Monitoring System file format. Doing the calibration manually has proven to be tedious and prone to errors, requiring a high degree of expertise. The Beowulf graphical user interface (GUI) is a software application that encompasses several components of the calibration task and generates a calibration block, as well as, a detailed report describing the specific calibration process used. This additional document can be used as a Quality assurance certificate to assist in auditing the calibration. This paper consists of two sections. Section 1 will describe the capabilities of Beowulf and section 2 will be a representative report generated or the 137Cs calibration and quality assurance source.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Influence of Vibration on Surface Roughness in Turning

Errors in machining and the relation between the final surface roughness and the vibration of the machining system (the lathe, the attachment, the tool, and the workpiece) are considered, for the case of turning. Software for visualization of surface roughness produced by machining is developed.

42 ENGINEERING↗

Solving the software protection problem with intrinsic personal physical unclonable functions.

Physical Unclonable Functions (PUFs) or Physical One Way Functions (P-OWFs) are physical systems whose responses to input stimuli (i.e., challenges) are easy to measure (within reasonable error bounds) but hard to clone. The unclonability property comes from the accepted hardness of replicating the multitude of characteristics introduced during the manufacturing process. This makes PUFs useful for solving problems such as device authentication, software protection, licensing, and certified execution. In this paper, we focus on the effectiveness of PUFs for software protection in offline settings. We first argue that traditional (black-box) PUFs are not useful for protecting software in settings where communication with a vendor's server or third party network device is infeasible or impossible. Instead, we argue that Intrinsic PUFs are needed to solve the above mentioned problems because they are intrinsically involved in processing the information that is to be protected. Finally, we describe how sources of randomness in any computing device can be used for creating intrinsic-personal-PUFs (IP-PUF) and present experimental results in using standard off-the-shelf computers as IP-PUFs.

99 GENERAL AND MISCELLANEOUS↗

The QICK (Quantum Instrumentation Control Kit): Readout and control for qubits and detectors

We introduce a Xilinx RF System-on-Chip (RFSoC)-based qubit controller (called the Quantum Instrumentation Control Kit, or QICK for short), which supports the direct synthesis of control pulses with carrier frequencies of up to 6 GHz. The QICK can control multiple qubits or other quantum devices. The QICK consists of a digital board hosting an RFSoC field-programmable gate array, custom firmware, and software and an optional companion custom-designed analog front-end board. We characterize the analog performance of the system as well as its digital latency, important for quantum error correction and feedback protocols. We benchmark the controller by performing standard characterizations of a transmon qubit. We achieve an average gate fidelity of ℱ avg =99.93%. All of the schematics, firmware, and software are open-source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of and data reduction from compact Thomson parabola spectrometers

Thomson parabola spectrometers are used to characterize MeV ion beams produced in high intensity laser interactions. These spectrometers disperse multiple ion species according to their charge to mass ratio through the use of parallel electric and magnetic fields. Analytical solutions for ion deflection in electric and magnetic fields have been used to extract ion spectra with the assumption that fringing effects are negligible. Experimental space restrictions and dynamic range requirements necessitate designs that stress the analytical assumptions. Depending on design parameters, the error in the analytical assumption can be comparable to the energy resolution. Estimates are provided to approximate the error on the total ion deflection. A method for modeling ion trajectories including fringing effects is presented using software freely available or in common use. The magnetostatic fields are modeled in 3D, including material properties of nearby magnetic materials using RADIA. Electrostatic fields are modeled in 2D for a spectrometer implementing angled plates using the partial differential equation toolbox in MATLAB. Using these models to calculate the ion trajectory allows for analysis of a Thomson parabola spectrometer with an arbitrary field configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Versioned distributed arrays for resilience in scientific applications: Global view resilience

Exascale studies project reliability challenges for future high-performance computing (HPC) systems. We propose the Global View Resilience (GVR) system, a library that enables applications to add resilience in a portable, application-controlled fashion using versioned distributed arrays. We describe GVR’s interfaces to distributed arrays, versioning, and cross-layer error recovery. Using several large applications (OpenMC, the preconditioned conjugate gradient solver PCG, ddcMD, and Chombo), we evaluate the programmer effort to add resilience. The required changes are small (<2% LOC), localized, and machine-independent, requiring no software architecture changes. We also measure the overhead of adding GVR versioning and show that generally overheads <2% are achieved. We conclude that GVR’s interfaces and implementation are flexible and portable and create a gentle-slope path to tolerate growing error rates in future systems.

97 MATHEMATICS AND COMPUTING↗

Software resilience and the effectiveness of software mitigation in microcontrollers

Commercially available microprocessors could be useful to the space community for noncritical computations. There are many possible components that are smaller, lower-power, and less expensive than traditional radiation-hardened microprocessors. Many commercial microprocessors have issues with single-event effects (SEEs), such as single-event upsets (SEUs) and single-event transients (SETs), that can cause the microprocessor to calculate an incorrect result or crash. In this paper we present the Trikaya technique for masking SEUs and SETs through software mitigation techniques. Furthermore, test results show that this technique can be very effective at masking errors, making it possible to fly these microprocessors for a variety of missions.

97 MATHEMATICS AND COMPUTING↗

Fractionated stereotactic radiotherapy: A method to evaluate geometric and dosimetric uncertainties using radiochromic films

In the authors' hospital, stereotactic radiotherapy treatments are performed with a Varian Clinac 600C equipped with a BrainLAB m3 micro-multileaf-collimator generally using the dynamic conformal arc technique. Patient immobilization during the treatment is achieved with a fixation mask supplied by BrainLAB, made with two reinforced thermoplastic sheets fitting the patient's head. With this work the authors propose a method to evaluate treatment geometric accuracy and, consequently, to determine the amount of the margin to keep in the CTV-PTV expansion during the treatment planning. The reproducibility of the isocenter position was tested by simulating a complete treatment on the anthropomorphic phantom Alderson Rando, inserting in between two phantom slices a high sensitivity Gafchromic EBT film, properly prepared and calibrated, and repeating several treatment sessions, each time removing the fixing mask and replacing the film inside the phantom. The comparison between the dose distributions measured on films and computed by TPS, after a precise image registration procedure performed by a commercial piece of software (FILMQA, 3cognition LLC (Division of ISP), Wayne, NJ), allowed the authors to measure the repositioning errors, obtaining about 0.5 mm in case of central spherical PTV and about 1.5 mm in case of peripheral irregular PTV. Moreover, an evaluation of the errors in the registration procedure was performed, giving negligible values with respect to the quantities to be measured. The above intrinsic two-dimensional estimate of treatment accuracy has to be increased for the error in the third dimension, but the 2 mm margin the authors generally use for the CTV-PTV expansion seems adequate anyway. Using the same EBT films, a dosimetric verification of the treatment planning system was done. Measured dose values are larger or smaller than the nominal ones depending on geometric irradiation conditions, but, in the authors' experimental conditions, always within 4%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-469: Implementation of VAs Web-Based Radiotherapy Incident Reporting and Analysis System (RIRAS)

Purpose: This Web-based Radiotherapy Incident Reporting and Analysis System (RIRAS) is a tool to improve quality of care for radiation therapy patients. This system is an important facet of continuing effort by our community to maintain and improve safety of radiotherapy.Material and Methods: VA’s National Radiation Oncology Program office has embarked on a program to electronically collect adverse events and good-catch data of radiation treatment of over 25,000 veterans treated with radiotherapy annually. This VA-Intranet based software design has made use of dataset taxonomies and data dictionaries defined in AAPM/ASTRO reports on error reporting. We used proven industrial and medical event reporting techniques to avoid several common problems faced in effective data collection such as incomplete data due to data entry fatigue by the reporters, missing data due to data difficult to obtain or not familiar to most reporters, missing reports due to fear of reprisal etc. This system encompasses the entire feedback loop of reporting an incident, analyzing it for salient details, and developing interventions to prevent it from happening again. The analysis reports with corrective, learning actions are shared with the reporter/facility and made public to the community (after deidentification) as part of the learning process. Results: Till date 50 incident/good catches have been reported in RIRAS and we have completed analysis on 100% of these reports. This is done due to the fact that each reported incidents is investigated and a complete analysis/patient-safety-work-product report is generated by radiation oncology domain-experts. Conclusions Because of the completeness of the data, the system has enabled us to analyze process steps and track trends of major errors which in the future will lead to implementing system wide process improvement steps and safe standard operating procedures for each radiotherapy treatment modality/technique and fulfills our goal of “Effecting Quality While Treating Safely”. RIRAS developed and copyrighted by TSG Innovations Inc.

60 APPLIED LIFE SCIENCES↗

WE-D-BRA-04: Online 3D EPID-Based Dose Verification for Optimum Patient Safety

Purpose: To develop an online 3D dose verification tool based on EPID transit dosimetry to ensure optimum patient safety in radiotherapy treatments. Methods: A new software package was developed which processes EPID portal images online using a back-projection algorithm for the 3D dose reconstruction. The package processes portal images faster than the acquisition rate of the portal imager (∼ 2.5 fps). After a portal image is acquired, the software seeks for “hot spots” in the reconstructed 3D dose distribution. A hot spot is in this study defined as a 4 cm{sup 3} cube where the average cumulative reconstructed dose exceeds the average total planned dose by at least 20% and 50 cGy. If a hot spot is detected, an alert is generated resulting in a linac halt. The software has been tested by irradiating an Alderson phantom after introducing various types of serious delivery errors. Results: In our first experiment the Alderson phantom was irradiated with two arcs from a 6 MV VMAT H&N treatment having a large leaf position error or a large monitor unit error. For both arcs and both errors the linac was halted before dose delivery was completed. When no error was introduced, the linac was not halted. The complete processing of a single portal frame, including hot spot detection, takes about 220 ms on a dual hexacore Intel Xeon 25 X5650 CPU at 2.66 GHz. Conclusion: A prototype online 3D dose verification tool using portal imaging has been developed and successfully tested for various kinds of gross delivery errors. The detection of hot spots was proven to be effective for the timely detection of these errors. Current work is focused on hot spot detection criteria for various treatment sites and the introduction of a clinical pilot program with online verification of hypo-fractionated (lung) treatments.

60 APPLIED LIFE SCIENCES↗