Sodium Pumping via Condensation within a Non-Wetting Porous Structure

The sodium thermal electrochemical converter (Na-TEC) is a heat engine that generates electricity via the isothermal expansion of sodium ions through a beta”-alumina solid-electrolyte. The transfer of liquid sodium from a low-pressure condenser to a high-pressure evaporator is necessary to complete the thermodynamic cycle for this conversion process. A unique sodium capillary pump for the Na-TEC is proposed, whereby low-pressure sodium vapor is condensed within a non-wetting (i.e. contact angle > 90o) stainless steel porous structure. Due to the curvature of the non-wetting liquid-vapor interface, the liquid adjacent to the interface is at a higher pressure than the vapor. This is in contrast to traditional wicks, where the liquid adjacent to the interface has a lower pressure. Thus, the curvature created at this non-wetting condensation interface supplies a directed force upon the liquid sodium that effectively “pushes” it towards a high pressure region, whereas a traditional capillary wick “pulls” the liquid. Porous structures made of stainless steel 316 are commercially available, and this material is non-wetting to sodium at the relevant temperature range of the Na-TEC condenser (500K – 673K). An experimental set-up is used to measure several interfacial and transport properties of the condensed sodium within this porous structure. These properties include the temperature dependent Laplace pressure generated at the phase change interface and the permeability of the porous structure. Liquid sodium is in contact with the porous structure and is progressively pressurized with argon gas until the sodium “breaks through” and the liquid begins to flow. This break-through pressure is determined when electrical contact is established between the flowing liquid metal and a set of electrodes cemented along the flow path. The velocity of the flowing sodium can also be measured with these electrodes, and the permeability is then determined by fitting velocity data to the classical Darcy law. These interfacial properties are then applied to a conjugate heat transfer model, which treats the coupled momentum and thermal transport processes within the non-wetting porous structure as sodium vapor is condensed. Due to the low mass flowrates in the Na-TEC (< 0.1 mg/s), higher order friction terms are neglected and the classical Darcy’s law is used for non-isothermal, compressible sodium vapor flow. At lower temperatures, the sodium vapor density becomes sufficiently small and there is a transition from classic Poiseuille flow (Kn < 0.1) to Knudsen flow (Kn > 10). Furthermore, transport due to binary diffusion is considered for situations where there is a substantial presence of non-condensable argon inside the sodium vapor plenum. Initial modeling results showing expected mass flowrates, temperature profiles, and liquid-vapor interface locations are presented for various physical conditions. Finally, the main design features of an experimental set-up used to demonstrate this capillary pumping is described in detail, including the method used to measure the low sodium mass flowrates. Initial experimental results demonstrating sodium pumping for a range of temperatures (800K – 1100K) will be presented and compared against the model predictions. A pump curve used to gauge the performance of this pumping mechanism is also created.

14 SOLAR ENERGY↗

Convective Heat Transfer in Decay Heat Exchanger of Sodium-cooled Fast Reactor

Sodium-to-sodium heat exchangers such as the decay heat exchanger (DHX) are key components of the prototype generation [V sodium-cooled fast reactor (PGSFR). The DHX transfers the decay heat generated in the reactor core to the decay heat removal loop after a reactor shutdown. Shell-and-tube type with straight tube arrangement has been widely adopted for the sodium-to-sodium heat exchanger of the sodium-cooled fast reactor. Thus liquid metal heat transfer characteristics inside the tube and around the tube bundle have to be fully understood to design the sodium-to-sodium heat exchanger and evaluate its thermal performance accurately. Plenty of studies on the convective heat transfer of the liquid metals were conducted to present the Nusselt number (Nu) correlations with respect to the Peclet number (Pe). However, those correlations still deviated from each other considerably and few of correlations for low Pe range (less than 100) have been reported. Accordingly, it is difficult for a design code developer to choose a proper heat transfer coefficient correlation for the sodium-to-sodium heat exchanger particularly in a low flow rate range. Recently, a separate effect test for the DHX has been completed using the STELLA-1 facility at KAERI according to the STELLA program which aims at establishment of separate and integral test database (DB) for the design of the PGSFR. The heat transfer performance test of the DHX was successfully conducted under major operating conditions. The objective of this work is to suggest proper convective heat transfer correlations for tube- and shell-sides of the sodium-to-sodium heat exchanger based on the test DB obtained from STELLA-1. The Pe range of the analyzed experimental data is concentrated on less then 100. The adequacy of the suggested correlations is evaluated by applying to the DHX design code, SHXSA. Based on the DHX test DB of the STELLA-1, the proper convective heat transfer correlations for the tube- and shell-side of sodium-to-sodium heat exchangers were suggested. Two correlation combinations for each side were proposed and turned out to be reasonable through the evaluation using the SHXSA design code: Suggestion no. 1: - Lyon correlation (constant = 4) for tube-side; - Lubarsky-Kaufman correlation for shell-side. Suggestion no. 2: - Modified Lyon correlation (constant = 1.45) for tube-side; - Schad-modified correlation for shell-side The Pe ranges of the DHX test DB were 53 - 225 for the tube-side and 45 - 148 for the shell-side, but most of test conditions were concentrated on the Pe range of less than 100. Two correlation suggestions can be practically used for the design of sodium-to-sodium heat exchangers. However, by utilizing more test DB, it needs to be verified which one is closer to real phenomena. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dry Deactivation of Sodium Metal in a Molten LiCl-KCl-CsCl-NaCl System

An experimental study was performed with the objective of investigating and characterizing a dry technique for deactivation of sodium metal in a molten salt system. The study was performed in three parts. First, proof-of-principle testing of the technique was performed at bench scale. It involved loading and melting tens of grams of clean sodium metal atop a pool of LiCl-KCl-CsCl eutectic at ∼300°C and then adding ammonium chloride particles while mixing. The ammonium chloride reacted with sodium to form sodium chloride and nitrogen/hydrogen off-gases. The sodium chloride assimilated into the salt pool, forming a quaternary salt mixture of LiCl-KCl-CsCl-NaCl. The proof-of-principle testing repeatedly exhibited complete deactivation of the loaded sodium metal. Second, characterization of a LiCl-KCl-CsCl-NaCl system was performed using differential scanning calorimetry to produce a partial phase diagram of LiCl-KCl-CsCl eutectic versus NaCl, which identified the liquidus, solidus, and two-phase regions of the quaternary system. Third, the dry deactivation technique was demonstrated at kg-scale in an inert atmosphere radiological glovebox with sodium metal that was previously separated in the same glovebox from uranium metal in unirradiated blanket elements for the Fermi-1 nuclear reactor. The quaternary salt product at the end of the demonstration was sampled and showed complete deactivation of the sodium metal. Here, in short, this study qualified a technique to completely deactivate batches of sodium metal in the absence of air or water. While this study focused on the deactivation of sodium metal, including bond sodium from unirradiated blanket elements, the technique is applicable to other sources of sodium metal, such as sodium metal from batteries. Furthermore, the technique could also be extended to other alkali metal systems, including lithium, sodium, potassium, rubidium, cesium, and mixtures thereof.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Interfacial and Transport Property Measurements of Liquid Sodium within a Porous Structure

The sodium thermal electrochemical converter (Na-TEC) is a heat engine that generates electricity via the isothermal expansion of sodium ions through a beta”-alumina solid-electrolyte. The transfer of liquid sodium from a low-pressure condenser to a high-pressure evaporator is necessary to complete the thermodynamic cycle for this conversion process. A unique sodium capillary pump for the Na-TEC is proposed, whereby low-pressure sodium vapor is condensed within a non-wetting (i.e. contact angle > π/2) porous sample. The curvature created at this non-wetting condensation interface supplies a directed force upon the liquid sodium that effectively “pushes” it towards a high pressure region, rather than a traditional capillary wick that “pulls” the liquid. Porous structures made of stainless steel 316 are commercially available, and this material is non-wetting to sodium at the relevant temperature range of the Na-TEC condenser (500K – 673K). An experimental set-up is used to measure several interfacial and transport properties of the condensed sodium within this porous structure. These properties include the temperature dependent Laplace pressure generated at the phase change interface and the permeability of the porous structure. For the former, liquid sodium is in contact with the porous structure and is progressively pressurized with argon gas in increments of ~ 5 kPa until the sodium “breaks through” and the liquid begins to flow. This breakthrough pressure is determined when electrical contact is established between the flowing liquid metal and a set of electrodes cemented into the flow path. The velocity of the flowing sodium can also be measured with these electrodes, and the permeability is then determined by fitting velocity data to the classical Darcy law. Statistically significant results of these measurements, taken at multiple sodium temperatures, are presented. Furthermore, contact angle measurements of sessile sodium drops on stainless steel 316 are demonstrated. This contact angle information is used to define an effective pore radius for the porous structure, which is then validated with microscopy. All the physical parameters described herein are used as inputs in a condensation model to predict the mass flowrate of condensing sodium under a given pressure gradient across the porous structure. This condensation model is used to design the capillary pump for the Na-TEC.

14 SOLAR ENERGY↗

Cold Trap Dismantling and Sodium Removal at a Fast Breeder Reactor - 12327

The first German prototype Fast Breeder Nuclear Reactor (KNK) is currently being dismantled after being the only operating Fast Breeder-type reactor in Germany. As this reactor type used sodium as a coolant in its primary and secondary circuit, seven cold traps containing various amounts of partially activated sodium needed to be disposed of as part of the dismantling. The resulting combined difficulties of radioactive contamination and high chemical reactivity were handled by treating the cold traps differently depending on their size and the amount of sodium contained inside. Six small cold traps were processed onsite by cutting them up into small parts using a band saw under a protective atmosphere. The sodium was then converted to sodium hydroxide by using water. The remaining large cold trap could not be handled in the same way due to its dimensions (2.9 m x 1.1 m) and the declared amount of sodium inside (1,700 kg). It was therefore manually dismantled inside a large box filled with a protective atmosphere, while the resulting pieces were packaged for later burning in a special facility. The experiences gained by KNK during this process may be advantageous for future dismantling projects in similar sodium-cooled reactors worldwide. The dismantling of a prototype fast breeder reactor provides the challenge not only to dismantle radioactive materials but also to handle sodium-contaminated or sodium-containing components. The treatment of sodium requires additional equipment and installations to ensure a safe handling. Since it is not permitted to bring sodium into a repository, all sodium has to be neutralized either through a controlled reaction with water or by incinerating. The resulting components can be disposed of as normal radioactive waste with no further conditions. The handling of sodium needs skilled and experienced workers to minimize the inherent risks. And the example of the disposal of the large KNK cold trap shows the interaction with others and also foreign decommissioning projects can provide solutions with were unknown before. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Removal and Deactivation of Bond Sodium from Fast Reactor Blanket Materials

The disposition of sodium-bonded spent nuclear fuel and blanket materials in a repository is complicated by the presence of sodium metal that is used as a thermal bond between the uranium metal fuel and blanket slugs and their cladding. The concern is that the metallic sodium could react with water, producing explosive hydrogen gas, or could exhibit a pyrophoric character. Thus, experimental studies were performed to investigate and demonstrate the removal and deactivation of bond sodium from blanket material in a dry environment. Specifically, bond sodium was removed from unirradiated Fermi-1 blanket elements and an assembly via a melt-drain-evaporate process using elevated temperature and reduced pressure. The effectiveness of sodium metal removal from the blanket materials and their associated cladding was =99.9998%, based on post-test quantitative analyses. The separated sodium metal was collected and subsequently deactivated by reacting it in a molten state with a controlled addition of ammonium chloride particles atop a molten salt medium. In this process sodium chloride is formed and assimilates into the salt pool. The subsequent deactivation of the bond sodium produced a solid ingot of sodium chloride, potassium chloride, lithium chloride, and cesium chloride that was devoid of sodium metal based on post-test analyses of the salt product. Both the sodium removal and deactivation operations were conducted within a dry inert atmosphere enclosure. The results of this study substantiate a path forward for the disposition of sodium-bonded blanket materials, including 34 metric tons heavy metal in irradiated Fermi-1 blanket material currently stored at Idaho National Laboratory.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FY 2017-Progress Report on the Design and Construction of the Sodium Loop SMT-3

This report provides an update on the design of a forced-convection sodium loop to be used for the evaluation of sodium compatibility of advanced Alloy 709 with emphasis on long term exposures of tensile, creep, fatigue, creep fatigue, and fracture toughness ASTM-size specimens in support of ASME Code qualification and NRC licensing. The report is a deliverable (Level 4) in FY17 (M4AT-17AN1602094), under the Work Package AT-17AN160209, “Sodium Compatibility” performed by Argonne National Laboratory (ANL), as part of the Advanced Materials Program for the Advanced Reactor Technology. This work package enables the development of advanced structural materials by providing corrosion, microstructure, and mechanical property data from the standpoint of sodium compatibility of advanced structural alloys. The first sodium loop (SMT-1) with a single tank was constructed in 2011 at ANL and has been in operation for exposure of subsize sheet specimens of advanced alloys at a single temperature. The second sodium loop with dual tanks (SMT-2) was constructed in 2013 and has been in operation for the exposure of subsize sheet specimens of advanced alloys at two different temperatures. The current loop (SMT-3) has been designed to incorporate sufficient chamber capacity to expose a large number of ASTM-size specimens to evaluate the sodium effects on tensile, creep, fatigue, creep-fatigue, and fracture toughness properties, in support of ASME Code Qualification and USNRC Licensing. The design of individual components for the third sodium loop SMT-3 is almost complete. The design also has been sent to an outside vendor for piping analysis to be in compliance with ASME Code. A purchase order has been placed with an outside vendor for the fabrication of major components such as the specimen exposure tanks. However, we have contracted with another vendor to establish the piping design in compliance with ASME design codes. The piping design was completed in FY2017 and the information is being transmitted to the tank fabricator. The SMT-3 loop will be located in Building 206 adjacent to the currently operating SMT-2 loop. In addition, we have demolished the aged power supply system in Building 206 and installed a new transformer, wiring, and power panels for the new loop. Procurement of some of the long lead items such as valves, EM pumps, EM flowmeters, etc. is in progress and will continue in FY 2018. The construction of components such as cold trap, economizers, piping arrangement etc. will be performed in the central shops at ANL. About 150 liters of sodium for the loop will be procured in early FY2018. The loop system is designed to circulate sodium through the sample tanks and the associated loop without an operator for an extended period of time. With the three sodium loops (with single-tank, dual-tank and four–tanks), materials can be tested at different sodium temperatures, and large tensile, creep, fatigue, creep-fatigue, and fracture toughness specimens can be exposed to sodium for extended periods of time and generate data on mechanical properties in support of ASME Code Qualification and USNRC Licensing of advanced Alloy 709 for use as a structural material in SFRs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Report on the completion of long-lead components procurement of new sodium materials test loop

This report provides an update on the completion of long-lead components procurement of new sodium materials test loop. The loop, designated as SMT-3, is a forced-convection sodium loop to be used for the evaluation of sodium compatibility of advanced Alloy 709 with emphasis on long term exposures of tensile, creep, fatigue, creep fatigue, and fracture toughness ASTM-size specimens in support of ASME Code qualification and NRC licensing. The report is a deliverable (Level 4) in FY18 (M4NT-18AN050503013), under the Work Package NT-18AN05050301, “A709 Sodium Compatibility” performed by Argonne National Laboratory (ANL), as part of the Advanced Materials Program for the Advanced Reactor Technology. This work package enables the development of advanced structural materials by providing corrosion, microstructure, and mechanical property data from the standpoint of sodium compatibility of advanced structural alloys. The first sodium loop (SMT-1) with a single tank was constructed in 2011 at ANL and has been in operation for exposure of subsize sheet specimens of advanced alloys at a single temperature. The second sodium loop with dual tanks (SMT-2) was constructed in 2013 and has been in operation for the exposure of subsize sheet specimens of advanced alloys at two different temperatures. The current loop (SMT-3) has been designed to incorporate sufficient chamber capacity to expose a large number of ASTM-size specimens to evaluate the sodium effects on tensile, creep, fatigue, creep-fatigue, and fracture toughness properties, in support of ASME Code Qualification and USNRC Licensing. Three major long lead items were identified: 1) Selection and approval of location for the new loop and installation of the necessary infrastructure, such as transformer, power supply panels, and wiring, that is adequate for the long term operation of the loop, 2) Perform a detailed piping analysis that meets the ANL QA and Safety guidelines as well as complying with ASME Code requirements, and 3) Design and fabrication of the specimen exposure vessels that are capable of at least 42 tensile, creep, and fatigue specimens in each vessel and is compliant and compatible with ASME Code and the piping design analysis. The SMT-3 loop will be located in Building 206 adjacent to the currently operating SMT-2 loop. In addition, we have removed the aged power supply system in Building 206 and installed a new transformer, wiring, and power panels for the new loop. The preliminary loop design was sent to an outside vendor for a detailed piping analysis, to ensure compliance with the ASME Code guidelines. The piping design was completed in FY2017. The construction of components such as cold trap, economizers, piping arrangement etc. will be performed in the central shops at ANL. About 150 liters of sodium for the loop will be procured in early FY2018. The loop system is designed to circulate sodium through the sample tanks and he associated loop without an operator for an extended period of time. With the three sodium loops (i.e., single-tank, dual-tank and four–tank), materials can be tested at different sodium temperatures, and large tensile, creep, fatigue, creep-fatigue, and fracture toughness specimens can be exposed to sodium for extended periods of time and generate data on mechanical properties in support of ASME Code Qualification and USNRC Licensing of advanced Alloy 709 for use as a structural material in SFRs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Influence of Sodium on the Tensile Properties of Optimized Grade 92 Steel

This report provides an update on the evaluation of sodium compatibility of advanced alloy, optimized Grade 92, and the reference materials. The report is a deliverable (Level 3) in FY15 (M3AT-15AN1602072), under the Work Package AR-15AN160207, “Sodium Compatibility” performed by Argonne National Laboratory (ANL), as part of Advanced Reactor Technologies program. This work package supports the advanced structural materials development by providing corrosion, microstructure, and tensile property data from the standpoint of sodium compatibility of advanced structural alloys. During this fiscal year, sodium exposure experiments were performed at 600°C in forced convection sodium loops at Argonne National Laboratory. The oxygen content of sodium was controlled by the cold-trapping method to achieve ≈1 wppm oxygen level. Specimens were removed from the sodium loop after a pre-determined exposure time for post-sodium-exposure-examination, including weight and thickness measurements, cross-sectional examinations, microhardness measurements, microstructural characterization, and tensile tests at the sodium exposure temperature. Data of sodium-exposed specimens were compared with thermal aging data obtained at 650°C to separate the effects of sodium exposures and thermal aging. This report adds to the results on corrosion performance, microstructure and tensile properties of ferritic-martensitic exposed to sodium at 600°C. Specimens of G92-0, Opt. G92-4, Opt. G92-4T, and G91-H30176 for times up to 8,200 h, and Opt. G92-8T for 1,653 h were exposed to sodium at 600°C.

36 MATERIALS SCIENCE↗

Studies Conducted of Sodium Carbonate Contaminant Found on the Wing Leading Edge and the Nose Cap of the Space Shuttle Orbiter

In early 2001, three of the space shuttle orbiters were found to have a sodium carbonate contaminant on the wing leading edge and nose cap. These parts are made of a reinforced carbon/carbon material protected by silicon carbide (SiC) and a glass coating. The glass coating is known as Type A and is primarily sodium silicate with particles of SiC. NASA Glenn Research Center's Environmental Durability Branch was asked to determine the chemistry of this deposit formation and assess any possible detrimental effects. At low temperatures, the reverse reaction is favorable. Previous studies of the corrosion of glass show that carbon dioxide in the presence of water does form sodium carbonate on sodium silicate glass (ref. 1). It is quite likely that a similar scenario exists for the orbiter wing leading edge. All three orbiters that formed sodium carbonate were exposed to rain. This formation of sodium carbonate was duplicated in the laboratory. The Type A glass, which coats the wing leading edge and nose cap, was made in a freestanding form and exposed to water in two separate experiments. In one set of experiments, the coating was placed in a petri dish filled with water. As the water evaporated, sodium carbonate formed. In another case, water was slowly dripped on the coating and sodium carbonate formed. The sodium carbonate was detected by chemical analysis and, in some cases, xray diffraction showed a hydrated sodium carbonate. The next step was to examine possible detrimental effects of this sodium carbonate. There are three likely scenarios for the sodium carbonate deposit: (1) it may be removed with a simple rinse, (2) it may remain and flow back into the Type A glass after heating during reentry, or (3) it may remain and flow onto unprotected SiC and/or other parts after heating during reentry. The effect of case 1 is to remove the Na2O constituent from the Type A glass, thus decreasing its effectiveness as a sealant. Even so, overall, it is probably the best approach and was used by the NASA Kennedy Space Center when the deposits were first observed. The effect of case 2 is minimal and would actually restore the the Type A glass to its composition before carbonate formation. However, the problem with allowing the carbonate to remain leads to the third scenario, the deposit flowing onto other parts. A series of tests were conducted on unprotected SiC, and minimal effects were found in the short-term, but other ceramic and metal parts could be damaged by the molten sodium carbonate and would require close monitoring.

Jacobson, Nathan S.↗

Method and system for producing hydrogen using sodium ion separation membranes

A method of producing hydrogen from sodium hydroxide and water is disclosed. The method comprises separating sodium from a first aqueous sodium hydroxide stream in a sodium ion separator, feeding the sodium produced in the sodium ion separator to a sodium reactor, reacting the sodium in the sodium reactor with water, and producing a second aqueous sodium hydroxide stream and hydrogen. The method may also comprise reusing the second aqueous sodium hydroxide stream by combining the second aqueous sodium hydroxide stream with the first aqueous sodium hydroxide stream. A system of producing hydrogen is also disclosed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Removal of Bond Sodium from Full-Length Unirradiated Fermi-1 Blanket Elements and Assembly via Melt-Drain-Evaporate Process

Equipment was designed, fabricated, tested, and operated in an inert atmosphere radiological glovebox at Idaho National Laboratory to demonstrate the removal of bond sodium from full-length unirradiated Fermi-1 radial blanket elements and an entire radial blanket assembly using a Melt-Drain-Evaporate process. A series of three runs was performed with individual and multiple radial Fermi-1 blanket elements, and a fourth run was conducted with an entire Fermi-1 radial blanket assembly. After each run, the depleted uranium alloy slugs in every element slid out of its cladding, mechanically exhibiting the effectual absence of bond sodium. Quantitative and further qualitative analyses of the treated Fermi-1 material revealed the substantive, if not complete, absence of sodium metal in blanket element components. Indeed, entire columns of depleted uranium alloy slugs and associated cladding from select treated elements were separately contacted with water to react with residual sodium metal on the element surfaces, forming hydrogen gas. Samples of the resultant gas were analyzed to quantify the hydrogen concentration, which correlated to a residual sodium metal content for the treated element. Accordingly, no detectable sodium metal (<7 µg) was found on the surfaces of multiple depleted uranium alloy slugs after removal from its cladding. Detectable sodium metal, ranging from 14 to 30 µg, was found on the surfaces of one separated column of slugs and two separated full-length cladding segments. Each element originally contained ~25 g of bond sodium, resulting in quantitative sodium metal removal efficiencies of =99.9998%. The remaining separated uranium alloy slugs and cladding segments from the four runs were piece-wise immersed in alcohol while videorecording possible gas bubble formation as an additional qualitative analysis for residual sodium metal on treated surfaces, which identified the predominant absence of sodium reactivity on the balance of treated Fermi-1 blanket material. The results of this demonstration substantiate a path forward for treatment and disposal of 34 metric tons heavy metal of irradiated sodium-bonded Fermi-1 blanket material currently stored at Idaho National Laboratory.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validation of CONTAIN-LMR code for accident analysis of sodium-cooled fast reactor containments

CONTAIN-LMR 1 is an analytical tool for the containment performance of sodium cooled fast reactors. In this code, the modelling for the sodium fire is included: the oxygen diffusion model for the sodium pool fire, and the liquid droplet model for the sodium spray fire. CONTAIN-LMR is also able to model the interaction of liquid sodium with concrete structure. It may be applicable to different concrete compositions. Testing and validation of these models will help to qualify the simulation results. Three experiments with sodium performed in the FAUNA facility at FZK have been used for the validation of CONTAIN-LMR. For pool fire tests, calculations have been performed with two models. The first model consists of one gas cell representing the volume of the burn compartment. The volume of the second model is subdivided into 32 coupled gas cells. The agreement between calculations and experimental data is acceptable. The detailed pool fire model shows less deviation from experiments. In the spray fire, the direct heating from the sodium burning in the media is dominant. Therefore, single cell modeling is enough to describe the phenomena. Calculation results have reasonable agreement with experimental data. Limitations of the implemented spray model can cause the overestimation of predicted pressure and temperature in the cell atmosphere. The ability of the CONTAIN-LMR to simulate the sodium pool fire accompanied by sodium-concrete reactions was tested using the experimental study of sodium-concrete interactions for construction concrete as well as for shielding concrete. The model provides a reasonably good representation of chemical processes during sodium-concrete interaction. The comparison of time-temperature profiles of sodium and concrete shows, that the model requires modifications for predictions of the test results. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Carburization and decarburization behavior of Grade 91 ferritic-martensitic steel in liquid sodium environments

Here, this paper presents a study of carbon transfer and its effect on microstructure and tensile properties of Grade 91 (G91) ferritic-martensitic steel exposed to sodium at 550–650 °C. Sodium exposure tests were conducted in Argonne's forced convection sodium loops up to exposure times of ~40,000 h. Thermal aging study of G91 steel was conducted in parallel to isolate the thermal aging effect from the sodium effect. It was found that sodium exposures at 650 °C dissolved M 23 C 6 carbides, eliminated the martensite subgrain structure resulting in excessive grain growth and reduced the tensile strength by >50%, while sodium exposures at 550 and 600 °C had an insignificant effect on its microstructure and tensile properties. These effects were attributed to the carburization/decarburization process of G91 steel in sodium environments. Carbon concentrations in sodium were determined by a foil equilibration method. The estimated carbon concentration was in the range of 0.8–1.2 ppm in the SMT-1 loop and 0.3–0.7 ppm in the SMT-2 loop. Thermodynamic analysis of the carburization – decarburization process was conducted for G91 steels exposed in sodium environments. The carbon activity-concentration relationship for G91 was evaluated by considering four phases in G91, i.e. bcc ferrite, M 23 C 6 , NbC and VC carbides. It was found that the carburization-decarburization process in G91 steel was dictated by M 23 C 6 carbides at high carbon activities, while NbC and VC carbides dominated the process at low carbon activities. The calculated carburization-decarburization boundary showed that G91 would undergo decarburization at 650 °C and carburization at 550 °C in the sodium loop environments, which was consistent with our experimental observations. This experimental and theoretical analysis provided a basis for predicting the effect of carbon transfer on the integrity of reactor components in sodium environments and for the design of new alloys used in sodium-cooled fast reactors.

36 MATERIALS SCIENCE↗

Sodium selenosulfate at an innocuous dose markedly prevents cisplatin-induced gastrointestinal toxicity

Our previous studies in mice revealed that two weeks short-term toxicity of sodium selenosulfate was significantly lower than that of sodium selenite, but selenium repletion efficacy of both compounds was equivalent. In addition, we showed that sodium selenosulfate reduced nephrotoxicity of cisplatin (CDDP) without compromising its anticancer activity, thus leading to a dramatic increase of cancer cure rate from 25% to 75%. Hydration has been used in clinical practice to reduce CDDP-induced nephrotoxicity, but it cannot mitigate CDDP-induced gastrointestinal toxicity. The present work investigated whether sodium selenosulfate is a potential preventive agent for the gastrointestinal toxicity. In tumor-bearing mice, sodium selenosulfate was administered at a dose of 9.5 μmol/kg daily for 11 days, CDDP alone resulted in diarrhea by 88% on day 12, whereas the co-administration of CDDP and sodium selenosulfate dramatically reduced diarrhea to 6% (p < 0.0001). Such a prominent protective effect promoted us to evaluate the safety potential of long-term sodium selenosulfate application. Mice were administered with sodium selenosulfate or sodium selenite for 55 days at the doses of 12.7 and 19 μmol/kg. The low-dose sodium selenite caused growth suppression and hepatotoxicity which were aggravated by the high-dose, leading to 40% mortality rate, but no toxic symptoms were observed in the two sodium selenosulfate groups. Altogether these results clearly show that sodium selenosulfate at an innocuous dose can markedly prevent CDDP-induced gastrointestinal toxicity. -- Highlights: ►Cisplatin resulted in diarrhea in mice by 88%. ►i.p. selenosulfate at 9.5 μmol/kg daily for 11 days reduced diarrhea to 6%. ►i.p. selenosulfate at 19 μmol/kg daily for 55 days was not toxic. ►i.p. selenite at 19 μmol/kg daily for 55 days was lethal. ►Innocuous dose of selenosulfate greatly prevents cisplatin-induced diarrhea.

60 APPLIED LIFE SCIENCES↗

Development of Thermoacoustic Sensors for Sodium-cooled Fast Reactors

This Final Report refers to the project “Development of Thermoacoustic Sensors for Sodium-cooled Fast Reactor Systems”, which was led by Westinghouse Electric Company (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and University of Pittsburgh. Thermo-acoustic Power Sensors (TAPS) are self-powered, wireless sensors envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. This project was intended to specifically investigate their applicability to Sodium-cooled Fast Reactors (SFR). TAPS are non-invasive (wireless) and passive (self-powered) devices. The passivity derives from their ability to use conditions that “naturally” exist in a nuclear reactor, such as gamma and neutron flux, as power sources. They generate oscillating pressure waves (i.e., sound waves) which, with a frequency and amplitude dependent upon these conditions, can travel through the core and associated structures, and reach the outside of the reactor vessel where a properly designed network of receivers can detect and interpret them. These receivers require a very small amount of power which, during loss of power events, can be provided for example by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. The project aimed at TAPS development through a series of tasks which are listed and briefly discussed as follows. TASK 1 – Sensor hardware design Subtask 1a: Assessment of sensor applications to SFRs Subtask 1b: Development of sensor functional requirements Subtask 1c: Definition of sensor hardware design specifications Task description: TAPS design was informed by considerations on their application (Subtask 1a), both the ultimate one in an SFR and the actual one in the ANL testing facilities that was intended to be used in support of the project. Considerations were made to identify optimum sensor design features that optimize the sensor size, materials, and output signal, for installation inside an SFR core. These considerations led to the development of Functional Requirements (Subtask 1b) and Design Requirements (Subtask 1c). TASK 2 – Sensor Hardware Manufacture Subtask 2a: Sensor hardware construction drawing development Subtask 2b: Sensor manufacture and assembly Task description: TAPS technical drawings were developed (Subtask 2a) using the Design Requirements established under Task 1. Subsequently, in spite of some problems which ultimately caused the program to be delayed, TAPS manufacturing was completed based on drawings (Subtask 2b). TASK 3 – Development of TAPS Signal Measurement System and TAPS Testing in Water Subtask 3a: Design, assembly and testing of signal measurement system, and TAPS testing in water Subtask 3b: Signal prediction-correction methodology development Task description: An assessment was performed on the techniques that can potentially be used to detect the signals emitted by the TAPS, e.g. a fiber-optic based acoustic signal measurement system, a laser vibrometer system, or an accelerometer-based system. The most suited technology, i.e. the accelerometer-based system, was developed further, and tested in water (Subtask 3a). Moreover, efforts were made to develop the methodology required to determine the actual system temperature and neutron flux distribution using differences between the measured and predicted TAPS responses (Subtask 3b). TASK 4 – Sensor System Testing in Sodium Subtask 4a: Test plan development Subtask 4b: Design, assembly and testing in small-scale sodium facility Subtask 4c: Design, assembly and testing in large-scale sodium and structures facility Task description: Upon proper test plan development (Subtask 4a), the fabricated TAPS was planned to be tested in sodium, by using two sodium facilities at ANL having different size and different purpose. The Under Sodium Viewing (USV) small-scale facility was intended to be used to investigate the effect of sodium on the sensor and its performance (Subtask 4b). The Mechanism Engineering Test Loop (METL) large-scale facility was instead intended to be used to assess the additional effect of prototypical SFR structures, such as fuel assembly mockup or parts of the core restrain structure, on sensor performance (Subtask 4c). As discussed in Section 3.2.2.7, unexpected issues during the TAPS manufacturing process resulted in some activities being delayed, with the TAPS and USV facility developed to the point to be ready for testing in sodium, however without the possibility to actually perform such testing (including the testing in METL) due to the end of the program’s performance period. Overall, through the development and testing (in water only) of two TAPS devices (a First-Generation TAPS followed by an optimized Second-Generation TAPS), the project confirmed the capability of this technology to generate acoustic signals proportional to temperature, which can be detected through a network of accelerometers identified as the best-suited type of receivers for acoustic signal detection. Moreover, the project also developed a computational model to predict the characteristics of the acoustic signals being generated, which combines thermal analysis of the TAPS with Finite Element Modeling (FEM)-aided acoustic characterization of the system. This model was benchmarked against experimental data collected during the project and, although general agreement was obtained, some limitations of the modeling methods were identified, which require additional development. Additional testing is needed in order to assess the effect, on TAPS operation and performance, of environmental changes resulting from the transition from water to liquid sodium. Such testing, which is suggested to be performed in the future, should look specifically at 1) both the effect resulting from the different thermoacoustic behavior of sodium (relative to water) and the effects of higher temperature on TAPS performance, and 2) the performance of the sensor-receiver system when multiple TAPS are used simultaneously and prototypical reactor structures are positioned in the testing environment. The latter testing is needed to assess the effects that potential signal attenuation/ distortion phenomena, as well as potential interference between signals emitted simultaneously, have on the performance of the technology for ultimate application in a nuclear reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sodium Recycle Economics for Waste Treatment Plant Operations

Sodium recycle at the Hanford Waste Treatment Plant (WTP) would reduce the number of glass canisters produced, and has the potential to significantly reduce the cost to the U.S. Department of Energy (DOE) of treating the tank wastes by hundreds of millions of dollars. The sodium, added in the form of sodium hydroxide, was originally added to minimize corrosion of carbon-steel storage tanks from acidic reprocessing wastes. In the baseline Hanford treatment process, sodium hydroxide is required to leach gibbsite and boehmite from the high level waste (HLW) sludge. In turn, this reduces the amount of HLW glass produced. Currently, a significant amount of additional sodium hydroxide will be added to the process to maintain aluminate solubility at ambient temperatures during ion exchange of cesium. The vitrification of radioactive waste is limited by sodium content, and this additional sodium mass will increase low-activity waste-glass mass. An electrochemical salt-splitting process, based on sodium-ion selective ceramic membranes, is being developed to recover and recycle sodium hydroxide from high-salt radioactive tank wastes in DOE’s complex. The ceramic membranes are from a family of materials known as sodium (Na)—super-ionic conductors (NaSICON)—and the diffusion of sodium ions (Na+) is allowed, while blocking other positively charged ions. A cost/benefit evaluation was based on a strategy that involves a separate caustic-recycle facility based on the NaSICON technology, which would be located adjacent to the WTP facility. A Monte Carlo approach was taken, and several thousand scenarios were analyzed to determine likely economic results. The cost/benefit evaluation indicates that 10,000–50,000 metric tons (MT) of sodium could be recycled, and would allow for the reduction of glass production by 60,000–300,000 MT. The cost of the facility construction and operation was scaled to the low-activity waste (LAW) vitrification facility, showing cost would be roughly $150 million to $400 million for construction and $10 million to $40 million per year for operations. Depending on the level of aluminate supersaturation allowed in the storage tanks in the LAW Pretreatment Facility, these values indicate a return on investment of up to 25% to 60%.

sodium recycle, waste treatment↗

Test Matrix for the Fundamental Sodium-CO 2 Interaction Experiment (SNAKE)

An initial test matrix for fundamental sodium (Na)-carbon dioxide (CO 2 ) interactions has been formulated. These tests are designed to provide the data needed to understand sodium-CO 2 interactions and their consequences for Sodium-Cooled Fast Reactors (SFRs) incorporating supercritical CO 2 Brayton cycle power converters with compact diffusion-bonded sodium-to-CO 2 heat exchangers. The approach begins by considering the scenario and conditions of failure and release of CO 2 into sodium in a compact diffusion-bonded sodium-to-CO 2 heat exchanger. Phenomena following failure are identified and assessed through first principles analyses to identify the relevant regimes and conditions for which data on sodium-CO 2 interactions is needed. This is an important point because most data on sodium-CO 2 interactions reported in the literature are for conditions of less relevance to the case of a compact diffusion-bonded heat exchanger in the intermediate sodium circuit of a SFR. Based upon the results of the phenomena identification and first principles assessment, needs for fundamental experiments on sodium-CO 2 interactions are identified, and for each type of experiment, a general test matrix is formulated for testing in the ANL Na-CO 2 Interaction facility, SNAKE (S-CO 2 Na Kinetics Experiment), and other experiment facilities. An assessment of the sodium-CO 2 interaction phenomena involved in failure of compact diffusion-bonded heat exchangers and the needs for fundamental sodium-CO 2 interaction data under realistic conditions informed by such an assessment has never been carried out prior to the present report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗