STELLAR ARCHEOLOGY IN THE GALACTIC HALO WITH ULTRA-FAINT DWARFS. VII. HERCULES

We present the first time-series study of the ultra-faint dwarf galaxy Hercules. Using a variety of telescope/instrument facilities we secured about 50 V and 80 B epochs. These data allowed us to detect and characterize 10 pulsating variable stars in Hercules. Our final sample includes six fundamental-mode (ab-type) and three first-overtone (c-type) RR Lyrae stars, and one Anomalous Cepheid. The average period of the ab-type RR Lyrae stars, (P{sub ab}) = 0.68 days ({sigma} = 0.03 days), places Hercules in the Oosterhoff II group, as found for almost the totality of the ultra-faint dwarf galaxies investigated so far for variability. The RR Lyrae stars were used to obtain independent estimates of the metallicity, reddening, and distance to Hercules, for which we find [Fe/H] = -2.30 {+-} 0.15 dex, E(B - V) = 0.09 {+-} 0.02 mag, and (m - M){sub 0} = 20.6 {+-} 0.1 mag, in good agreement with the literature values. We have obtained a V, B - V color-magnitude diagram (CMD) of Hercules that reaches V {approx} 25 mag and extends beyond the galaxy's half-light radius over a total area of 40' Multiplication-Sign 36'. The CMD and the RR Lyrae stars indicate the presence of a population as old and metal-poor as (at least) the Galactic globular cluster M68.

79 ASTRONOMY AND ASTROPHYSICS↗

2540 km: Bimagic Baseline for Neutrino Oscillation Parameters

We show that a source-to-detector distance of 2540 km, motivated recently [S. K. Raut, R. S. Singh, and S. U. Sankar, arXiv:0908.3741] for a narrow band superbeam, offers multiple advantages for a low energy neutrino factory with a detector that can identify muon charge. At this baseline, for any neutrino hierarchy, the wrong-sign muon signal is almost independent of CP violation and {theta}{sub 13} in certain energy ranges. This allows the identification of the hierarchy in a clean way. In addition, part of the muon spectrum is also sensitive to the CP violating phase and {theta}{sub 13}, so that the same setup can be used to probe these parameters as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MRI-based Preplanning Using CT and MRI Data Fusion in Patients With Cervical Cancer Treated With 3D-based Brachytherapy: Feasibility and Accuracy Study

Purpose: Magnetic resonance imaging (MRI)-assisted radiation treatment planning enables enhanced target contouring. The purpose of this study is to analyze the feasibility and accuracy of computed tomography (CT) and MRI data fusion for MRI-based treatment planning in an institution where an MRI scanner is not available in the radiotherapy department. Methods and Materials: The registration inaccuracy of applicators and soft tissue was assessed in 42 applications with CT/MRI data fusion. The absolute positional difference of the center of the applicators was measured in four different planes from the top of the tandem to the cervix. Any inaccuracy of registration of soft tissue in relation to the position of applicators was determined and dose-volume parameters for MRI preplans and for CT/MRI fusion plans with or without target and organs at risk (OAR) adaptation were evaluated. Results: We performed 6,132 measurements in 42 CT/MRI image fusions. Median absolute difference of the center of tandem on CT and MRI was 1.1 mm. Median distance between the center of the right ovoid on CT and MRI was 1.7 and 1.9 mm in the laterolateral and anteroposterior direction, respectively. Corresponding values for the left ovoid were 1.6 and 1.8 mm. Rotation of applicators was 3.1 Degree-Sign . Median absolute difference in position of applicators in relation to soft tissue was 1.93, 1.50, 1.05, and 0.84 mm in the respective transverse planes, and 1.17, 1.28, 1.27, and 1.17 mm in selected angular directions. The dosimetric parameters for organs at risk on CT/MRI fusion plans without OAR adaptation were significantly impaired whereas the target coverage was not influenced. Planning without target adaptation led to overdosing of the target volume, especially high-risk clinical target volume - D{sub 90} 88.2 vs. 83.1 (p < 0.05). Conclusions: MRI-based preplanning with consecutive CT/MRI data fusion can be safe and feasible, with an acceptable inaccuracy of soft tissue registration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electro-osmo-dialysis through nanoporous layers physically conjugated to micro-perforated ion-exchange membranes: Highly selective accumulation of trace coions

This study explores theoretically and numerically the phenomenon of counter-flow accumulation of trace coions during electro-osmo-dialysis through composite membranes containing nanoporous and perforated ion-exchange layers. The combination of charged nanopores and perforations allows electroosmosis, and ion concentration polarization appears near the ion-exchange layer. Accumulation of trace coions occurs because their advective and electromigration flow velocity components have opposite signs and are locally compensating in depletion regions where electric fields are high. This local compensation of flow components can give rise to high accumulation factors (>1000 in some cases) for trace coions at some distance from the interface between the nanoporous and ion-exchange layers. Moreover, the extent of this accumulation depends on the trace-coion diffusion coefficient. The resulting selectivity between different coions might serve as a basis for environmentally friendly separation of ionic species such as synthetic peptides or rare-earth elements. For example, a periodic process might include accumulation followed by species release into smaller volumes of solution. For both rare-earth ions and peptide-like species, the accumulation selectivity between ions with small differences in mobilities depends on system parameters such as nanoporous-layer thickness, distance between the perforations, and the zeta potential of the nanopore surface. Here, the use of optimal values of these membrane parameters may enable tuning of the electro-osmo-dialysis system for separation of specific ions. Modelling reveals that despite inhomogeneous patterns of fluid and ion flows close to the nanoporous/perforated ion-exchange interface, at relatively short distances from this interface (less than half the distance between the perforations) all the flows become practically one-dimensional (1D). Similarly, the concentration profiles of trace coions also become 1D. The flow one-dimensionality at short distances from the current-polarized interface enables a simple 1D approximation that is useful for an approximate analysis of trends in this multi-parameter system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precursor of pair-density wave in doping Kitaev spin liquid on the honeycomb lattice

Abstract We study the effects of doping the Kitaev model on the honeycomb lattice where the spins interact via the bond-directional interaction J K , which is known to have a quantum spin liquid as its exact ground state. The effect of hole doping is studied within the t - J K model on a three-leg cylinder using density-matrix renormalization group. Upon light doping, we find that the ground state of the system has a dominant quasi-long-range charge-density-wave correlations but short-range single-particle correlations. In the pairing channel, the even-parity superconducting correlation is dominant with d -wave-like symmetry, which oscillates in sign as a function of separation with a period equal to that of the spin-density wave and two times the charge-density wave. Although these correlations fall rapidly (possibly exponentially) at long distances, this is never-the-less the example where a pair-density wave is the leading instability in the pairing channel on the honeycomb lattice.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

PDR MODEL MAPPING OF PHYSICAL CONDITIONS VIA SPITZER/IRS SPECTROSCOPY OF H{sub 2}: THEORETICAL SUCCESS TOWARD NGC 2023-SOUTH

We use the Infrared Spectrograph on Spitzer to observe the southern part of the reflection nebula NGC 2023, including the Southern Ridge, which is a photodissociation region (PDR) par excellence excited by HD 37903. Five pure-rotational H{sub 2} emission lines are detected and mapped over and around the Southern Ridge in order to compare with predicted level column densities from theoretical PDR models. We find very good agreement between PDR model predictions and emission line intensities and ratios measured with Spitzer, leading us to conclude that grain photoelectric heating sufficiently warms the gas to produce the observed H{sub 2} line emission via collisional excitation. On the Southern Ridge, we infer a hydrogen nucleus density n{sub H} Almost-Equal-To 2 Multiplication-Sign 10{sup 5} cm{sup -3} and radiation field strength {chi} Almost-Equal-To 10{sup 4} relative to the local Galactic interstellar radiation field. This high value for {chi} independently predicts a distance toward HD 37903 of 300 pc and is consistent with the most recent Hipparcos results. Over the map we find that both n{sub H} and {chi} vary by a factor of {approx}3. Such two-dimensional variations provide clues about the underlying three-dimensional structure of the Southern Ridge field, which appears to be the tip of a molecular cloud. We also map variations in excitation temperature and the ortho-to-para ratio, the latter attaining values of {approx}1.5-2.0 on the Southern Ridge, and find that PDR modeling can readily reproduce observed ortho-to-para ratios that are <3 for rotational excitation dominated by collisional processes. Last, the stars Sellgren C and G are discovered to be resolved on archival Hubble Space Telescope images into two point sources each, with separations of {approx}<0.''5.

79 ASTRONOMY AND ASTROPHYSICS↗

J/{psi}({psi}{sup '}) Production at the Tevatron and LHC at O({alpha}{sub s}{sup 4}v{sup 4}) in Nonrelativistic QCD

We present a complete evaluation for J/{psi}({psi}{sup '}) prompt production at the Tevatron and LHC at next-to-leading order in nonrelativistic QCD, including color-singlet, color-octet, and higher charmonia feeddown contributions. The short-distance coefficients of {sup 3}P{sub J}{sup [8]} at next-to-leading order are found to be larger than leading order by more than an order of magnitude but with a minus sign at high transverse momentum p{sub T}. Two new linear combinations of color-octet matrix elements are obtained from the CDF data, and used to predict J/{psi} production at the LHC, which agrees with the CMS data. The possibility of {sup 1}S{sub 0}{sup [8]} dominance and the J/{psi} polarization puzzle are also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gibbs-Thomson Law for Singular Step Segments: Thermodynamics Versus Kinetics

Classical Burton-Cabrera-Frank theory presumes that thermal fluctuations are so fast that at any time density of kinks on a step is comparable with the reciprocal intermolecular distance, so that the step rate is about isotropic within the crystal plane. Such azimuthal isotropy is, however, often not the case: Kink density may be much lower. In particular, it was recently found on the (010) face of orthorhombic lysozyme that interkink distance may exceed 500-600 intermolecular distances. Under such conditions, Gibbs-Thomson law (GTL) may not be applicable: On a straight step segment between two corners, communication between the comers occurs exclusively by kink exchange. Annihilation between kinks of opposite sign generated at the comers results in the grain in step energy entering GTL. If the step segment length l much greater than D/v, where D and v are the kink diffusivity and propagation rate, respectively, the opposite kinks have practically no chance to annihilate and GTL is not applicable. The opposite condition of the GTL applicability, l much less than D/v, is equivalent to the requirement that relative supersaturation Delta(sub mu)/kT much less than alpha/l, where alpha is molecular size. Thus, GTL may be applied to a segment of 10(exp 3)alpha approx. 3 x 10(exp -5)cm approx 0.3 micron only if supersaturation is less than 0.1%, while practically used driving forces for crystallization are much larger. Relationships alternative to the GTL for different, but low, kink density have been discussed. They confirm experimental evidences that the Burton-Cabrera-Frank theory of spiral growth is growth rates twice as low as compared to the observed figures. Also, application of GTL results in unrealistic step energy while suggested kinetic law give reasonable figures.

Chernov, A. A.↗

Evaluation of superficial dosimetry between treatment planning system and measurement for several breast cancer treatment techniques

Purpose: Dosimetric accuracy in radiation treatment of breast cancer is critical for the evaluation of cosmetic outcomes and survival. It is often considered that treatment planning systems (TPS) may not be able to provide accurate dosimetry in the buildup region. This was investigated in various treatment techniques such as tangential wedges, field-in-field (FF), electronic compensator (eComp), and intensity-modulated radiotherapy (IMRT). Methods: Under Institutional Review Board (IRB) exemption, radiotherapy treatment plans of 111 cases were retrospectively analyzed. The distance between skin surface and 95% isodose line was measured. For measurements, Gafchromic EBT2 films were used on a humanoid unsliced phantom. Multiple layers of variable thickness of superflab bolus were placed on the breast phantom and CT scanned for planning. Treatment plans were generated using four techniques with two different grid sizes (1 Multiplication-Sign 1 and 2.5 Multiplication-Sign 2.5 mm{sup 2}) to provide optimum dose distribution. Films were placed at different depths and exposed with the selected techniques. A calibration curve for dose versus pixel values was also generated on the same day as the phantom measurement was conducted. The DICOM RT image, dose, and plan data were imported to the in-house software. On axial plane of CT slices, curves were drawn at the position where EBT2 films were placed, and the dose profiles on the lines were acquired. The calculated and measured dose profiles were separated by check points which were marked on the films before irradiation. The segments of calculated profiles were stretched to match their resolutions to that of film dosimetry. Results: On review of treatment plans, the distance between skin and 95% prescribed dose was up to 8 mm for plans of 27 patients. The film measurement revealed that the medial region of phantom surface received a mere 45%-50% of prescribed dose. For wedges, FF, and eComp techniques, region around the nipple received approximately 80% of prescribed dose, although only IMRT showed inhomogeneous dose profile. At deeper depths mainly (6-11 mm depths), film dosimetry showed good agreement with the TPS calculation. In contrast, the measured dose at a 3-mm depth was higher than TPS calculation by 15%-30% for all techniques. For the tangential and IMRT techniques, 1 Multiplication-Sign 1 mm{sup 2} grid size showed a smaller difference than that with a 2.5 Multiplication-Sign 2.5 mm{sup 2} grid size compared to the measurements. Conclusions: In general, TPS even with advanced algorithms do not provide accurate dosimetry in the buildup region, as verified by EBT2 film for all treatment techniques. For all cases, TPS and measured doses were in agreement from 6 mm in depth but differed at shallower depths. Grid size plays an important role in dose calculation. For accurate dosimetry small grid size should be used where differences are lower between TPS and measurements.

60 APPLIED LIFE SCIENCES↗

Dosimetric perturbations due to an implanted cardiac pacemaker in MammoSite{sup Registered-Sign} treatment

Purpose: To investigate dose perturbations for pacemaker-implanted patients in partial breast irradiation using high dose rate (HDR) balloon brachytherapy. Methods: Monte Carlo (MC) simulations were performed to calculate dose distributions involving a pacemaker in Ir-192 HDR balloon brachytherapy. Dose perturbations by varying balloon-to-pacemaker distances (BPD = 50 or 100 mm) and concentrations of iodine contrast medium (2.5%, 5.0%, 7.5%, and 10.0% by volume) in the balloon were investigated for separate parts of the pacemaker (i.e., battery and substrate). Relative measurements using an ion-chamber were also performed to confirm MC results. Results: The MC and measured results in homogeneous media without a pacemaker agreed with published data within 2% from the balloon surface to 100 mm BPD. Further their dose distributions with a pacemaker were in a comparable agreement. The MC results showed that doses over the battery were increased by a factor of 3, compared to doses without a pacemaker. However, there was no significant dose perturbation in the middle of substrate but up to 70% dose increase in the substrate interface with the titanium capsule. The attenuation by iodine contrast medium lessened doses delivered to the pacemaker by up to 9%. Conclusions: Due to inhomogeneity of pacemaker and contrast medium as well as low-energy photons in Ir-192 HDR balloon brachytherapy, the actual dose received in a pacemaker is different from the homogeneous medium-based dose and the external beam-based dose. Therefore, the dose perturbations should be considered for pacemaker-implanted patients when evaluating a safe clinical distance between the balloon and pacemaker.

60 APPLIED LIFE SCIENCES↗

Selecting registration schemes in case of interstitial lung disease follow-up in CT

Purpose: Primary goal of this study is to select optimal registration schemes in the framework of interstitial lung disease (ILD) follow-up analysis in CT. Methods: A set of 128 multiresolution schemes composed of multiresolution nonrigid and combinations of rigid and nonrigid registration schemes are evaluated, utilizing ten artificially warped ILD follow-up volumes, originating from ten clinical volumetric CT scans of ILD affected patients, to select candidate optimal schemes. Specifically, all combinations of four transformation models (three rigid: rigid, similarity, affine and one nonrigid: third order B-spline), four cost functions (sum-of-square distances, normalized correlation coefficient, mutual information, and normalized mutual information), four gradient descent optimizers (standard, regular step, adaptive stochastic, and finite difference), and two types of pyramids (recursive and Gaussian-smoothing) were considered. The selection process involves two stages. The first stage involves identification of schemes with deformation field singularities, according to the determinant of the Jacobian matrix. In the second stage, evaluation methodology is based on distance between corresponding landmark points in both normal lung parenchyma (NLP) and ILD affected regions. Statistical analysis was performed in order to select near optimal registration schemes per evaluation metric. Performance of the candidate registration schemes was verified on a case sample of ten clinical follow-up CT scans to obtain the selected registration schemes. Results: By considering near optimal schemes common to all ranking lists, 16 out of 128 registration schemes were initially selected. These schemes obtained submillimeter registration accuracies in terms of average distance errors 0.18 ± 0.01 mm for NLP and 0.20 ± 0.01 mm for ILD, in case of artificially generated follow-up data. Registration accuracy in terms of average distance error in clinical follow-up data was in the range of 1.985–2.156 mm and 1.966–2.234 mm, for NLP and ILD affected regions, respectively, excluding schemes with statistically significant lower performance (Wilcoxon signed-ranks test, p < 0.05), resulting in 13 finally selected registration schemes. Conclusions: Selected registration schemes in case of ILD CT follow-up analysis indicate the significance of adaptive stochastic gradient descent optimizer, as well as the importance of combined rigid and nonrigid schemes providing high accuracy and time efficiency. The selected optimal deformable registration schemes are equivalent in terms of their accuracy and thus compatible in terms of their clinical outcome.

60 APPLIED LIFE SCIENCES↗

Vacancy Relaxation in Cubic Crystals

The configuration of the atoms surrounding a vacancy in four face-centered cubic and three body-centered cubic metals has been computed, using a pairwise, central-force model in which the energy of interaction between two atoms was taken to have the form of a Morse function. Only radial relaxations were considered. The first and second nearest-neighbor relaxations for the face-centered systems were found to be: Pb (1.42,−0.43), Ni (2.14,−0.39), Cu(2.24,−0.40) and Ca (2.73,−0.41, expressed in percentages of normal distances. For the body-centered systems the relaxations out to the fourth nearest neighbors to the vacancy were: Fe (6.07,−2.12, −0.25, −), Ba (7.85, −2.70, 0.70, −0.33) and Na (10.80, −3.14, 3.43, −0.20). The positive signs indicate relaxation toward the vacancy and the negative signs indicate relaxation away from the vacancy. The energies of relaxation (eV) are: Pb (0.162), Ni (0.626), Cu (0.560), Ca (0.400), Fe (1.410), Ba (0.950) and Na (0.172).

Girifalco, L. A.↗

Prediction of a measurable sign change in the Casimir force using a magnetic fluid

Here, we demonstrate quantum levitation controlled by Casimir forces acting between a polystyrene surface and a Teflon-coated metallic substrate immersed in a mixture of toluene and magnetite particles. This system experiences repulsion-attraction transitions in the Casimir interaction for distances where the effect is measurable. This Casimir trapping can be controlled by clever choices of metallic and ferrofluid materials, which are directly linked to the emergence of the trapping effect. Thermal and quantum contributions are investigated in detail, showing how the optical and magnetic properties of the ferrofluid and other materials affect the magnitude of the trapping and its distance range of observability.

Ma, Long [University of South Florida, Tampa, FL (↗

WISEP J061135.13–041024.0 AB: A J-band flux reversal binary at the L/T transition

We present Keck II laser guide star adaptive optics observations of the brown dwarf WISEP J061135.13–041024.0 showing it is a binary with a component separation of 0.''4. This system is one of the six known resolved binaries in which the magnitude differences between the components show a reversal in sign between the Y/J band and the H/K bands. Deconvolution of the composite spectrum results in a best-fit binary solution with L9 and T1.5 components. We also present a preliminary parallax placing the system at a distance of 21.2 ± 1.3 pc. Using the distance and resolved magnitudes we are able to place WISEP J061135.13–041024.0 AB on a color-absolute magnitude diagram, showing that this system contributes to the well-known 'J-band bump' and the components' properties appear similar to other late-type L and early-type T dwarfs. Fitting our data to a set of cloudy atmosphere models suggests the system has an age >1 Gyr with WISE 0611–0410 A having an effective temperature (T {sub eff}) of 1275-1325 K and mass of 64-65 M {sub Jup}, and WISE 0611–0410 B having T {sub eff} = 1075-1115 K and mass 40-65 M {sub Jup}.

79 ASTRONOMY AND ASTROPHYSICS↗

AMUSE-Field I: NUCLEAR X-RAY PROPERTIES OF LOCAL FIELD AND GROUP SPHEROIDS ACROSS THE STELLAR MASS SCALE

We present the first results from AMUSE-Field, a Chandra survey designed to characterize the occurrence and intensity of low-level accretion onto supermassive black holes (SMBHs) at the center of local early-type field galaxies. This is accomplished by means of a Large Program targeting a distance-limited (<30 Mpc) sample of 103 early types spanning a wide range in stellar masses. We acquired new ACIS-S observations for 61 objects down to a limiting (0.3-10 keV) luminosity of 2.5 Multiplication-Sign 10{sup 38} erg s{sup -1}, and we include an additional 42 objects with archival (typically deeper) coverage. A nuclear X-ray source is detected in 52 out of the 103 galaxies. After accounting for potential contamination from low-mass X-ray binaries, we estimate that the fraction of accreting SMBHs within the sample is 45% {+-} 7%, which sets a firm lower limit on the occupation fraction within the field. The measured nuclear X-ray luminosities are invariably highly sub-Eddington, with L{sub X}/L{sub Edd} ratios between {approx}10{sup -4} and 10{sup -8}. As also found in a companion survey targeting Virgo early types, the active fraction increases with increasing host galaxy stellar mass, reflective of 'Eddington incompleteness' within the lower-mass objects. For the Field sample, the average nuclear X-ray luminosity scales with the host stellar mass as M{sup 0.71{+-}0.10}{sub star}, with an intrinsic scatter of 0.73 {+-} 0.09 dex. Qualitatively similar results hold for morphologically homogeneous (type E) or uniform sensitivity (new observations only) subsets. A majority of the AMUSE-Field galaxies (78%) inhabit groups, enabling us to investigate the influence of group richness on nuclear activity. We see no evidence for a positive correlation between nuclear X-ray luminosity, normalized to host properties, and galaxy density. Rather, while the scatter is substantial, it appears that the Eddington-scaled X-ray luminosity of group members may be slightly lower than for isolated galaxies, and that this trend continues to cluster early types.

79 ASTRONOMY AND ASTROPHYSICS↗

Numerical, experimental, and theoretical study of convective instability of flows over pointed bodies at incidence

A study is conducted to investigate whether the behavior of the asymmetric mean flow observed on pointed bodies of revolution at incidence remains consistent with the presence of a convective instability of an original symmetric flow, even in the incidence range where virtually bistable behavior of the asymmetric flow is observed. By means of a retractable wire located near the tip, it is determined experimentally that for all angles of attack tested (30 to 60 degs), changing the size or location of the controlled disturbance results in a finite change in the asymmetric flow field, even to the extent of reversing the sign of the side force or becoming almost symmetric. The process is reversible; returning the wire to an original position likewise restores the corresponding flow field and mean side force. The effect of wire location (roll angle and distance from the tip) as well as angle of attack and flow conditions are evaluated experimentally by means of flow visualization and side-force measurements for a generic ogive-cylinder model in a low-speed wind tunnel. Evaluation of the results in the light of computational observations and theoretical considerations yields an affirmative answer to the question posed.

Degani, David↗

PRESENT-DAY GALACTIC EVOLUTION: LOW-METALLICITY, WARM, IONIZED GAS INFLOW ASSOCIATED WITH HIGH-VELOCITY CLOUD COMPLEX A

The high-velocity cloud Complex A is a probe of the physical conditions in the Galactic halo. The kinematics, morphology, distance, and metallicity of Complex A indicate that it represents new material that is accreting onto the Galaxy. We present Wisconsin H{alpha} Mapper kinematically resolved observations of Complex A over the velocity range of -250 to -50 km s{sup -1} in the local standard of rest reference frame. These observations include the first full H{alpha} intensity map of Complex A across (l, b) = (124 Degree-Sign , 18 Degree-Sign ) to (171 Degree-Sign , 53 Degree-Sign ) and deep targeted observations in H{alpha}, [S II] {lambda}6716, [N II] {lambda}6584, and [O I] {lambda}6300 toward regions with high H I column densities, background quasars, and stars. The H{alpha} data imply that the masses of neutral and ionized material in the cloud are similar, both being greater than 10{sup 6} M{sub Sun }. We find that the Bland-Hawthorn and Maloney model for the intensity of the ionizing radiation near the Milky Way is consistent with the known distance of the high-latitude part of Complex A and an assumed cloud geometry that puts the lower-latitude parts of the cloud at a distance of 7-8 kpc. This compatibility implies a 5% ionizing photon escape fraction from the Galactic disk. We also provide the nitrogen and sulfur upper abundance solutions for a series of temperatures, metallicities, and cloud configurations for purely photoionized gas; these solutions are consistent with the sub-solar abundances found by previous studies, especially for temperatures above 10{sup 4} K or for gas with a high fraction of singly ionized nitrogen and sulfur.

79 ASTRONOMY AND ASTROPHYSICS↗

FARADAY TOMOGRAPHY OF THE NORTH POLAR SPUR: CONSTRAINTS ON THE DISTANCE TO THE SPUR AND ON THE MAGNETIC FIELD OF THE GALAXY

We present radio continuum and polarization images of the North Polar Spur (NPS) from the Global Magneto-ionic Medium Survey conducted with the Dominion Radio Astrophysical Observatory 26 m Telescope. We fit polarization angle versus wavelength squared over 2048 frequency channels from 1280 to 1750 MHz to obtain a Faraday rotation measure (RM) map of the NPS. Combining this RM map with a published Faraday depth (FD) map of the entire Galaxy in this direction, we derive the FD introduced by the NPS and the Galactic interstellar medium (ISM) in front of and behind the NPS. The FD contributed by the NPS is close to zero, indicating that the NPS is an emitting only feature. The FD caused by the ISM in front of the NPS is consistent with zero at b > 50°, implying that this part of the NPS is local at a distance of approximately several hundred parsecs. The FD contributed by the ISM behind the NPS gradually increases with Galactic latitude up to b = 44°, and decreases at higher Galactic latitudes. This implies that either the part of the NPS at b < 44° is distant or the NPS is local but there is a sign change of the large-scale magnetic field. If the NPS is local, there is then no evidence for a large-scale anti-symmetry pattern in the FD of the Milky Way. The FD introduced by the ISM behind the NPS at latitudes b > 50° can be explained by including a coherent vertical magnetic field.

79 ASTRONOMY AND ASTROPHYSICS↗