Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Phase locking of a seven-channel continuous wave fibre laser system by a stochastic parallel gradient algorithm

A seven-channel fibre laser system operated by the master oscillator – multichannel power amplifier scheme is the phase locked using a stochastic parallel gradient algorithm. The phase modulators on lithium niobate crystals are controlled by a multichannel electronic unit with the microcontroller processing signals in real time. The dynamic phase locking of the laser system with the bandwidth of 14 kHz is demonstrated, the time of phasing is 3 – 4 ms. (fibre and integrated-optical structures)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Some notes on the application of discrete wavelet transform in image processing

Mathematical transforms are used in signal processing in order to extract what is known as 'hidden' information. One of these mathematical tools is the Discrete Wavelet Transform (DWT), which has been increasingly employed in non-destructive testing and, more specifically, in image processing. The main concern in the present work is to employ DWT to suppress noise without losing relevant image features. However, some aspects must be taken into consideration when applying DWT in image processing, mainly in the case of weld radiographs, in order to achieve consistent results. Three topics were selected as representative of these difficulties, as follows: 1) How can image matrix be filled to fit the 2{sup n} lines and 2{sup n} rows requirement? 2) How can the most suitable decomposition level of the DWT function and the correct choice of their coefficient suppression be selected? 3) Is there any influence of the scanning direction and the weld radiograph image, e.g., longitudinal or transversal, on the final processing image? It is known that some artifacts may be present in weld radiograph images. Indeed, the weld surface is frequently rough and rippled, what can be seen as gray level variation on the radiograph, being sometimes mistaken as defective areas. Depending on the position of these artifacts, longitudinal or transversal to the weld bead, they may have different influences on the image processing procedure. This influence is clearly seen in the distribution of the DWT Function coefficients. In the present work, examples of two weld radiographs of quite different image quality were given in order to exemplify it.

07 ISOTOPE AND RADIATION SOURCES↗

Nonlinear analog processing with anisotropic nonlinear films

Digital signal processing is the cornerstone of several modern-day technologies, yet in multiple applications it faces critical bottlenecks related to memory and speed constraints. Thanks to recent advances in metasurface design and fabrication, light-based analog computing has emerged as a viable option to partially replace or augment digital approaches. Several light-based analog computing functionalities have been demonstrated using patterned flat optical elements, with great opportunities for integration in compact nanophotonic systems. So far, however, the available operations have been restricted to the linear regime, limiting the impact of this technology to a compactification of Fourier optics systems. In this paper, we introduce nonlinear operations to the field of metasurface-based analog optical processing, demonstrating that nonlinear optical phenomena, combined with nonlocality in flat optics, can be leveraged to synthesize kernels beyond linear Fourier optics, paving the way to a broad range of new opportunities. As a practical demonstration, we report the experimental synthesis of a class of nonlinear operations that can be used to realize broadband, polarization-selective analog-domain edge detection.

analog image processing↗

Recursive Use of the Short-Time Fast Fourier Transform for Signature Analysis in Continuous Processes

Although a nuclear reactor is a hostile environment for sensing and electrical communications, the reactor core is amenable to acoustic communication. An acoustic measurement infrastructure (AMI) has been installed in the Advanced Test Reactor (ATR) to record acoustic signals that can capture its different operating regimes. AMI uses coolant pumps as continuous signal sources, coolant and structural components as transmission lines, and accelerometers to capture system motion. A recursive signal processing technique based on the short-time fast Fourier transform (STFFT) for continuous processes provides unique signatures for diagnostic and prognostic analyses from the system motion data. Here this article presents a recursive STFFT methodology that processes acoustic signals from continuous industrial processes. The article first discusses the initial STFFT use with simulated data to elucidate the basic principles necessary to understand and interpret the STFFT results from actual pump vibration data. Each repetitive use of the STFFT on pump vibration data using the results from the prior STFFT processing will generate additional complimentary time-frequency-based signatures. These signatures are generated by the coolant pumps operating under different process conditions. After each use of the STFFT, the resulting signatures provide exemplary examples of the diversity and intuitive nature of recursively using the STFFT. This article focuses on recursively using the STFFT to provide numerous complimentary and diverse signatures that will ultimately be inputs for machine learning algorithms that provide predictive data analytics. The intuitive nature of the information and signatures from recursive STFFT processing will also bring intuitive interpretation capabilities to machine learning and predictive data analytic techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multichannel Deconvolution of Vibrational Shock Signals: An Inverse Filtering Approach

When transporting critical systems of national security interest, out-of-the ordinary, impulsive events that can potentially be undetected and affect overall system performance are of great concern. Impulsive events that can occur are essentially pulse-like, transient signals of short duration that evolve from various phenomena. Here the event can be created by either the dropping of a test object, the system, subjecting it to a compact high-energy blow or being struck unintentionally during transit resulting in potential damage. The intensity and location of the strike can cause an inoperability condition that is unacceptable in a national security environment. Therefore, it is essential to detect, classify and localize damage of any test object subjected to an impulsive-event. This effort was targeted to evaluate the vibrational response of test objects that are subjected to “transport” shocks and roadway vibrations during shipping and handling. Any potential damage that could be inflicted during transportation must not only be detected, but also be evaluated to determine the operational readiness of a test object before and after transport. This event is a critical task that must be addressed as part of the Lawrence Livermore National Laboratory (LLNL) national security mission. The estimation of excitation signals from noisy data is termed the deconvolution problem in the signal processing literature. The deconvolution problem is based on recovering the input excitation signal from a system characterized by its impulse response sequence. Using this model of the system, an “inverse” representation or filter is developed to remove the system from the measured data and recover the input. Deconvolution techniques have existed for a long-time; however, transient deconvolution presents a few uncommon problems, since the signal has a finite-length time duration resulting in a limited amount of data containing information about the excitation process. The transient is wideband in the frequency domain relative to any measurement sensor implying that the smaller bandwidth sensor system “filters” the excitation eliminating some of its essential information for recovery. This fact, coupled with the filtering effect of the test object itself makes this excitation recovery (deconvolution) problem a challenge for signal processing.

42 ENGINEERING↗

Multi-scale organization in communicating active matter

The emergence of collective motion among interacting, self-propelled agents is a central paradigm in non-equilibrium physics. Examples of such active matter range from swimming bacteria and cytoskeletal motility assays to synthetic self-propelled colloids and swarming microrobots. Remarkably, the aggregation capabilities of many of these systems rely on a theme as fundamental as it is ubiquitous in nature: communication. Despite its eminent importance, the role of communication in the collective organization of active systems is not yet fully understood. Here we report on the multi-scale self-organization of interacting self-propelled agents that locally process information transmitted by chemical signals. We show that this communication capacity dramatically expands their ability to form complex structures, allowing them to self-organize through a series of collective dynamical states at multiple hierarchical levels. Our findings provide insights into the role of self-sustained signal processing for self-organization in biological systems and open routes to applications using chemically driven colloids or microrobots.

59 BASIC BIOLOGICAL SCIENCES↗

A high sensitivity fiber optic macro-bend based gas flow rate transducer for low flow rates: Theory, working principle, and static calibration

A novel fiber optic macro-bend based gas flowmeter for low flow rates is presented. Theoretical analysis of the sensor working principle, design, and static calibration were performed. The measuring system consists of: an optical fiber, a light emitting diode (LED), a Quadrant position sensitive Detector (QD), and an analog electronic circuit for signal processing. The fiber tip undergoes a deflection in the flow, acting like a cantilever. The consequent displacement of light spot center is monitored by the QD generating four unbalanced photocurrents which are function of fiber tip position. The analog electronic circuit processes the photocurrents providing voltage signal proportional to light spot position. A circular target was placed on the fiber in order to increase the sensing surface. Sensor, tested in the measurement range up to 10 l min{sup -1}, shows a discrimination threshold of 2 l min{sup -1}, extremely low fluid dynamic resistance (0.17 Pa min l{sup -1}), and high sensitivity, also at low flow rates (i.e., 33 mV min l{sup -1} up to 4 l min{sup -1} and 98 mV min l{sup -1} from 4 l min{sup -1} up to 10 l min{sup -1}). Experimental results agree with the theoretical predictions. The high sensitivity, along with the reduced dimension and negligible pressure drop, makes the proposed transducer suitable for medical applications in neonatal ventilation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Time-Domain Reflectometry for Unattended Safeguards Systems: FY16 Report

The International Atomic Energy Agency (IAEA) continues to expand its use of unattended measurement systems. An increasing number of systems and an expanding family of instruments create challenges in terms of deployment efficiency and the implementation of data authentication measures. Traditional data security measures, for example tamper-indicating (TI) conduit, are impractical for the long separation distances (often 100 meters or more) between unattended monitoring system (UMS) components. Pacific Northwest National Laboratory (PNNL) is studying the viability of active time-domain reflectometry (TDR) for the detection of cable tampering in unattended radiation detection systems. The instrument concept under investigation would allow for unmanned cable integrity measurements, remote surveillance reporting and locating of cable faults and/or tampers. This report describes PNNL’s FY16 progress and includes: an overview of the TDR methods under investigation; description of the TDR evaluation testbed developed by PNNL; development and testing of advanced signal processing algorithms to extract weak signals from relatively high noise levels; and initial testing of a laboratory prototype intended for IAEA UMS applications and based on a commercially available TDR module. Preliminary viability findings and recommendations for the next stage of development and testing are provided.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Multi-INT Signature Collection and Exploitation for Security Los Alamos LDRD Report

This project demonstrates the feasibility of a 2-D passive tracking capability for ground-based and airborne moving sources using multi-INT signal processing of acoustic and seismic signals. We leveraged the recent DDSTE-supported investment in rapid deployable sensors (the Los Alamos Rapid-deployable Sensor Array—LARSA), and used uncrewed aerial vehicles (UAV) as a data source. Moving source types are characterized by their variability with time (exemplified but not limited to the Doppler shift of a passing vehicle) and the signatures used for detection should have similar characteristics. We have demonstrated that time-varying sensor signatures (TVS) combined with time-stable sensor signatures provide a more complete understanding of moving source behavior and drive towards path prediction. Importantly, we have collected a new, relevant LANL dataset of moving sources (small UAV flights and vehicle movement), developed new signatures, and demonstrated a capability to identify, track and forecast the position of TVS.

42 ENGINEERING↗

Electrochemical sensing using voltage-current time differential

A device for signal processing. The device includes a signal generator, a signal detector, and a processor. The signal generator generates an original waveform. The signal detector detects an affected waveform. The processor is coupled to the signal detector. The processor receives the affected waveform from the signal detector. The processor also compares at least one portion of the affected waveform with the original waveform. The processor also determines a difference between the affected waveform and the original waveform. The processor also determines a value corresponding to a unique portion of the determined difference between the original and affected waveforms. The processor also outputs the determined value.

99 GENERAL AND MISCELLANEOUS↗

Electrochemical sensing using comparison of voltage-current time differential values during waveform generation and detection

A device for signal processing. The device includes a signal generator, a signal detector, and a processor. The signal generator generates an original waveform. The signal detector detects an affected waveform. The processor is coupled to the signal detector. The processor receives the affected waveform from the signal detector. The processor also compares at least one portion of the affected waveform with the original waveform. The processor also determines a difference between the affected waveform and the original waveform. The processor also determines a value corresponding to a unique portion of the determined difference between the original and affected waveforms. The processor also outputs the determined value.

47 OTHER INSTRUMENTATION↗

Phosphor thermometry device for synchronized acquisition of luminescence lifetime decay and intensity on thermal barrier coatings

A phosphor thermometry device includes a laser that generates a laser pulse onto a thermal barrier coating (TBC) applied onto a substrate. A metallic bond coat layer is on the substrate. A ceramic top coat layer is on the bond coat layer and includes an undoped layer and a doped sensing layer having co-doped first and second rare-earth luminescent dopants that emit respective first and second different emission wavelengths upon excitation by the laser pulse. A detector receives reflected, convoluted luminescence signals from the TBC. First and second photomultiplier devices detect respective first and second different emission wavelengths of the convoluted luminescence signals. A controller receives and processes signals generated from respective first and second photomultiplier devices and determines luminescence lifetime decay and intensity variations for each of the respective first and second rare-earth luminescent dopants for temperature monitoring of the TBC.

Fouliard, Quentin↗

Lateral position detection and control for friction stir systems

A friction stir system for processing at least a first workpiece includes a spindle actuator coupled to a rotary tool comprising a rotating member for contacting and processing the first workpiece. A detection system is provided for obtaining information related to a lateral alignment of the rotating member. The detection system comprises at least one sensor for measuring a force experienced by the rotary tool or a parameter related to the force experienced by the rotary tool during processing, wherein the sensor provides sensor signals. A signal processing system is coupled to receive and analyze the sensor signals and determine a lateral alignment of the rotating member relative to a selected lateral position, a selected path, or a direction to decrease a lateral distance relative to the selected lateral position or selected path. In one embodiment, the friction stir system can be embodied as a closed loop tracking system, such as a robot-based tracked friction stir welding (FSW) or friction stir processing (FSP) system.

Fleming, Paul↗

Test facility for fission chamber assemblies - 239

The Institution -Project Center ITER- with participation of the National Research Nuclear University MEPhI are developing the neutron diagnostics -Divertor Neutron Flux Monitor- (DNFM) for the International Thermonuclear Experimental Reactor (ITER). This diagnostics shall ensure measurement of the total neutron yield and ITER fusion power. Assemblies of fission chambers (FC) with different fissile materials and sensitivities are planned to be used for the neutron flux measurement. Study of fission chambers characteristics and acceptance testing of the diagnostic system will be carried out at the testing facility of the neutronic laboratory of the 'TRINITI' Institute. The facility includes: compact powerful neutron generator with the power, control and monitoring system; remote handling system for FCs positioning and movement; novel three channels data acquisition and processing system. Each acquisition channel contains some measuring circuits with signal processing. This set of circuits provides neutron flux measurement in the range of at least 10 decades for each single FC. Data acquisition and processing system features are: signal digitizing with sample rate up to 125 MHz; real time data processing with computation and data update cycle from 0.1 ms. This paper examines the structure, composition and specification of the test facility. Application software, hardware solutions and the results of fission chambers prototypes tests are discussed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantized Information in Spectral Cyberspace

The constant-Q Gabor atom is developed for spectral power, information, and uncertainty quantification from time–frequency representations. Stable multiresolution spectral entropy algorithms are constructed with continuous wavelet and Stockwell transforms. The recommended processing and scaling method will depend on the signature of interest, the desired information, and the acceptable levels of uncertainty of signal and noise features. Selected Lamb wave signatures and information spectra from the 2022 Tonga eruption are presented as representative case studies. Resilient transformations from physical to information metrics are provided for sensor-agnostic signal processing, pattern recognition, and machine learning applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

A generalized machine learning workflow to visualize mechanical discontinuity

Accurate detection and mapping of mechanical discontinuity in materials has widespread industrial and research applications. Herein, we developed a generalized machine-learning framework for visualizing single mechanical discontinuity embedded in material of any composition, velocity, density, porosity, and size with limited data. The proposed visualization of discontinuity requires accurate estimations of the length, location, and orientation of the embedded discontinuity by processing multipoint wave-transmission measurements. k-Wave simulator is used to create a large dataset of elastic waveforms recorded during multi-point wave-transmission measurements through materials containing single mechanical discontinuity. k-Wave simulator considers the wave attenuation, dispersion, and mode conversion in wave motion. Discrete wavelet transform (DWT) and statistical feature extraction are essential for data preprocessing prior to the data-driven model development. DWT also minimizes the effect of noise. Using hyper-parameter tuning and cross validation, gradient boosting regression can visualize the mechanical discontinuity with an accuracy of 0.85, in terms of coefficient of determination. A double-layered neural network-based regression has better performance with an accuracy of 0.95. Use of convolutional neural network converts the predictive task from a waveform processing to an image processing problem. Convolutional neural network achieved a generalization performance of 0.91. The proposed generalized workflow requires robust simulation of wave propagation, signal processing, feature engineering, and model evaluation. Sensors closest to the source and those located opposite the source are the most significant for the desired visualization. Notably, the sensors closest to the source capture the non-linear associations, whereas the sensor on the border opposite to the source capture the linear associations between the measured waveforms and the properties of the mechanical discontinuity.

42 ENGINEERING↗

Spatio-Temporal Signal Twice-Whitening Algorithms on the hx3100 Ultra-Low Power Multicore Processor

While modern signal detection theory fully accounts for spatially distributed sensors, exploiting these techniques for real-time sensing using large, underwater acoustic arrays requires advances in the spatio-temporal signal processing algorithms. In particular, the computational complexity of many spatio-temporal processing techniques is so large that conventional computer processors lack sufficient throughput to provide real-time processing of large spatio-temporal data sets. These limits are exacerbated when constraints, such as power consumption or footprint, reduce the available computational resources. In this report, we demonstrate an implementation of a signal twice-whitening algorithm that is better suited for processing spatio-temporal data in real time. We emphasize these advances by implementing data whitening on the Coherent Logix hx3100 processor, a programmable multicore processor intended for low-power and high-throughput signal processing. These results serve as an example of how the novel capabilities available from emerging multicore processor platforms can provide real-time, software-defined processing of large data sets acquired by spatially distributed sensing.

99 GENERAL AND MISCELLANEOUS↗

Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis

We report that wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual’s state of health. Sampling human sweat, which is rich in physiological information13, could enable non-invasive monitoring. Previously reported sweat-based and other noninvasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanically flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Lastly, our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plasticbased sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing.

47 OTHER INSTRUMENTATION↗