Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor fabrication”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Development of High Temperature Gas Sensor Technology

The measurement of engine emissions is important for their monitoring and control. However, the ability to measure these emissions in-situ is limited. We are developing a family of high temperature gas sensors which are intended to operate in harsh environments such as those in an engine. The development of these sensors is based on progress in two types of technology: (1) The development of SiC-based semiconductor technology; and (2) Improvements in micromachining and microfabrication technology. These technologies are being used to develop point-contact sensors to measure gases which are important in emission control especially hydrogen, hydrocarbons, nitrogen oxides, and oxygen. The purpose of this paper is to discuss the development of this point-contact sensor technology. The detection of each type of gas involves its own challenges in the fields of materials science and fabrication technology. Of particular importance is sensor sensitivity, selectivity, and stability in long-term, high temperature operation. An overview is presented of each sensor type with an evaluation of its stage of development. It is concluded that this technology has significant potential for use in engine applications but further development is necessary.

Hunter, Gary W.↗

Remote query measurement of pressure, fluid-flow velocity, and humidity using magnetoelastic thick-film sensors

Free-standing magnetoelastic thick-film sensors have a characteristic resonant frequency that can be determined by monitoring the magnetic flux emitted from the sensor in response to a time varying magnetic field. This property allows the sensors to be monitored remotely without the use of direct physical connections, such as wires, enabling measurement of environmental parameters from within sealed, opaque containers. In this work, we report on application of magnetoelastic sensors to measurement of atmospheric pressure, fluid-flow velocity, temperature, and mass load. Mass loading effects are demonstrated by fabrication of a remote query humidity sensor, made by coating the magnetoelastic thick film with a thin layer of solgel deposited Al2O3 that reversibly changes mass in response to humidity. c2000 Elsevier Science S.A. All rights reserved.

NASA Discipline Life Sciences Technologies↗

Solid state devices

The Solid State Device research program is directed toward developing innovative devices for space remote and in-situ sensing, and for data processing. Innovative devices can result from the standard structures in innovative materials such as low and high temperature superconductors, strained layer superlattices, or diamond films. Innovative devices can also result from innovative structures achieved using electron tunneling or nanolithography in standard materials. A final step is to use both innovative structures and innovative materials. A new area of emphasis is the miniaturization of sensors and instruments molded by using the techniques of electronic device fabrication to micromachine silicon into micromechanical and electromechanical sensors and actuators.

Source record↗

Development of the NASA Mini/MEMS Tri-Axis Sensor System

This manuscript details the development of a reduced volume attitude sensor developed at NASA. This new sensor uses MEMs based accelerometers to reduce the volume when compared to current sensors used in wind-tunnel models. Our team has designed, fabricated, and evaluated the Mini/MEMs Tri-Axis Sensor System (MTASS). The current MTASS design accommodates three tactical-grade accelerometers into the volume of a single axis accelerometer that is currently used. This arrangement allows for the estimation of model pitch and roll angles. Static testing of the MTASS demonstrated angle accuracies within ±0.01° for both pitch and roll.

angle measurement↗

Development of the NASA Mini/MEMS Tri-Axis Sensor System

This manuscript details the development of a reduced volume attitude sensor developed at NASA. This new sensor uses MEMs based accelerometers to reduce the volume when compared to current sensors used in wind-tunnel models. Our team has designed, fabricated, and evaluated the Mini/MEMs Tri-Axis Sensor System (MTASS). The current MTASS design accommodates three tactical-grade accelerometers into the volume of a single axis accelerometer that is currently used. This arrangement allows for the estimation of model pitch and roll angles. Static testing of the MTASS demonstrated angle accuracies within ±0.01° for both pitch and roll.

angle measurement↗

Miniaturized metal (metal alloy)/ PdO.sub.x/SiC hydrogen and hydrocarbon gas sensors

A miniaturized Schottky diode hydrogen and hydrocarbon sensor and the method of making same is disclosed and claimed. The sensor comprises a catalytic metal layer, such as palladium, a silicon carbide substrate layer and a thin barrier layer in between the catalytic and substrate layers made of palladium oxide (PdO.sub.x). This highly stable device provides sensitive gas detection at temperatures ranging from at least 450 to 600.degree. C. The barrier layer prevents reactions between the catalytic metal layer and the substrate layer. Conventional semiconductor fabrication techniques are used to fabricate the small-sized sensors. The use of a thicker palladium oxide barrier layer for other semiconductor structures such as a capacitor and transistor structures is also disclosed.

Hunter, Gary W.↗

Miniaturized Metal (Metal Alloy)/PdO(x)/SiC Hydrogen and Hydrocarbon Gas Sensors

A miniaturized Schottky diode hydrogen and hydrocarbon sensor and the method of making same is disclosed and claimed. The sensor comprises a catalytic metal layer, such as palladium, a silicon carbide substrate layer and a thin barrier layer in between the catalytic and substrate layers made of palladium oxide (PdO(x)). This highly stable device provides sensitive gas detection at temperatures ranging from at least 450 to 600 C. The barrier layer prevents reactions between the catalytic metal layer and the substrate layer. Conventional semiconductor fabrication techniques are used to fabricate the small-sided sensors. The use of a thicker palladium oxide barrier layer for other semiconductor structures such as a capacitor and transistor structures is also disclosed.

Hunter, Gary W.↗

Miniaturized metal (metal alloy)/ PdO.sub.x/SiC hydrogen and hydrocarbon gas sensors

A miniaturized Schottky diode hydrogen and hydrocarbon sensor and the method of making same is disclosed and claimed. The sensor comprises a catalytic metal layer, such as palladium, a silicon carbide substrate layer and a thin barrier layer in between the catalytic and substrate layers made of palladium oxide (PdO.sub.x ). This highly stable device provides sensitive gas detection at temperatures ranging from at least 450 to 600.degree. C. The barrier layer prevents reactions between the catalytic metal layer and the substrate layer. Conventional semiconductor fabrication techniques are used to fabricate the small-sized sensors. The use of a thicker palladium oxide barrier layer for other semiconductor structures such as a capacitor and transistor structures is also disclosed.

Hunter, Gary W.↗

Additively Printed Flexible Temperature Sensor for Wearable Applications

The flexible sensor has the capability to be mounted on any curved surfaces of applications and be used for portable devices. Additively printed sensors have received attention owing to their compact design and ability of application to non-planar surfaces. Wearable applications require capability of integration into a variety of surfaces with ability to flex, fold, twist and stretch under the stresses of daily motion. There is scarcity of data on the interaction of the process parameters with the realized performance. In addition, there is need for data focused on sensor accuracy, repeatability, and reliability. In this study, experimental analysis on function of the fabricated sensing board is conducted. The temperature sensors are made by direct write printing method with nScrypt printer. A calibration of the sensors has been conducted to confirm that resistance is well related to actual temperature and find TCR (temperature coefficient to resistance). The evolution of resistance has been correlated with the environmental temperature. The sensor hysteresis has been quantified using upswing and downswing of the environmental temperature. In addition, the effect of humidity on the temperature sensor accuracy and performance has been quantified. The effect of a polymide coat on the sensor to prevent humidity effects has also been quantified.

Pradeep Lall↗

Rational Design of Nanoplasmonic Array Geometries for Biosensing

Background: Molecular diagnostics provide early and accurate diagnosis, which is essential for the prevention and treatment of infectious as well as chronic diseases. These tests are designed to detect disease-specific bioanalytes such as nucleic acid (DNA or RNA) or protein (antigens, antibodies) biomarkers. In the context of infectious disease diagnosis, nucleic acid-based detection methods are known to provide more specific and sensitive results. Here, the presence of a unique sequence belonging to the pathogenic genomic material is targeted to identify species, organism, genera and/or antimicrobial resistant gene markers. The majority of the common nucleic acid based diagnostic techniques require amplification (polymerase chain reaction, isothermal amplification etc.) of the pathogenic genetic material prior to detection impacting diagnostic speed, complexity, and cost thereby limiting ease of use. Thus, the development of simplified nucleic acid-based diagnostics that can be even used in resource-poor settings may hugely benefit patients across the globe. Nanopath is a molecular diagnostics company utilizing a solid-state nanosensor to enable sequence-specific detection of target nucleic acids without the need of amplification. These nanostructures enable ultra-sensitive biomarker detection using geometric, feature-dependent properties highly dependent on the local dielectric environment, allowing them to be sensitive to low concentration binding events. This paper describes an application of this approach to provide highly relevant clinical information within a single doctor’s office visit. Intro: The Nanopath team is in collaboration with NASA (National Aeronautics and Space Administration) and NIST (National Institute of Standards and Technology) to push the bounds of the fundamental physics associated with their biosensing platform. The ability of metals to support electromagnetic surface waves gives rise to surface plasmons when optically illuminated. This property, and its strong sensitivity to changes in the local refractive index, allows for the use of metal nanoparticles as ultra-sensitive transducers. In prior work by members of this team, ensembles of randomly oriented nanoparticles (i.e., colloidal nanorods dispersed on chip) were employed for sequence-specific nucleic acid sensing (1-3). While these particle sensors have the advantage of rapid fabrication, they suffer from low sensitivity and quality factor due to the random particle dispersity. In contrast, in this study we employ ordered array nanoparticle ensembles which can be used to improve sensor sensitivity and figure-of-merit. Study Methods Overview: In this talk, we detail the results of sensing experiments and computational simulations to outline a rational design of the structure of these plasmonic nanoparticle arrays for biomolecular sensing. Through simulation and experiment, we iteratively tailor nanostructure dimension to provide high quality signal and large resonance shifts upon modeled nucleic acid binding. In particular, full-wave electromagnetic simulations were conducted using Lumerical photonic simulation software in which periodic boundary conditions were applied in the x- and y- dimensions for each of the nanoplasmonic sensor geometries. To simulate the resonance response to changes in the bulk solution in contact with the sensor surface, the refractive index of the surrounding media was changed appropriately. Nucleic acid hybridization events were modeled using either using spherical structures approximating the relevant radius of genomic material as estimated by polymer models, or as conformal layers with the known refractive indices for nucleic acids. On the basis of initial simulations, nanosensors were fabricated using traditional electron-beam lithography protocols at NIST. To evaluate consensus between simulations and experiments, bulk sensing experiments were carried out in which the resonance peaks were obtained by submerging the sensors in refractive index standards. Key nanosensor characteristics including resonance peak locations, resonance peak shifts as a function of refractive index, and figure of merit (FOM) of extinction curves were examined between the experimental and simulation results prior to proceeding with simulations on additional geometries and more complex solution conditions, and further device fabrication. This iterative process is repeated toward a rational design of nanoplasmonic array geometries for biosensing optimizing response for targeted disease detection. In summary, this study puts forth a methodology for rational design and characterization of regularly spaced nanoparticle arrays for optics-based biosensing. The results of this study will allow for more informed design of nanostructure geometries towards sequence-specific nucleic acid detection. These improved designs have the potential to improve clinical sensitivity and limit-of-detection across disease indication.

sensor↗

Development of a high temperature fatigue sensor.

An experimental program was conducted to extend the Tracor Safety Gauge (patent pending) to elevated temperature service. The Safety Gauge is based on a conductive composite device which can be fabricated to function as a fatigue sensor that undergoes an irreversible resistance increase which results from cumulative strain damage. Prototype sensors were developed which appear capable of 1000 deg F operation for short periods of time (approaching one hour); however, bonding difficulties currently limit their use to about 775 deg F. The resistance change of the sensor was generally on the order of 400% or greater as the fatigue life of a titanium alloy (Ti-5Al-2.5Sn) test specimen was approached.

Wells, T. L.↗

Integrated Shear Stress/Temperature Micromachined Sensors

During this project we were able to design and initiate the fabrication of an integrated Micro ElectroMechanical Systems (MEMS)-based shear stress/temperature sensor for flow control applications. A brief summary of the completed activities during this project is presented.

Sheplak, Mark↗

Flexible Microsensor Array for the Monitoring and Control of Plant Growth System

Testing for plant experiments in space has begun to explore active nutrient delivery concepts in which water and nutrients are replenished on a continuous basis for long-term growth. The goal of this study is to develop a novel microsensor array to provide information on the dissolved oxygen environment in the plant root zone for the optimum control of hydroponics and solid substrate plant cultivation systems in the space environment. Miniaturized polarographic dissolved oxygen sensors have been designed and fabricated on a flexible Kapton (trademark) (polyimide) substrate. Two capabilities of the new microsensor array were explored. First, measurements of dissolved oxygen in the plant root zone in hydroponics and solid substrate culture systems were made. The microsensor array was fabricated on a flexible substrate, and then cut out into a mesh type to make a suspended array that could be placed either in a hydroponics system or in a solid substrate cultivation system to measure the oxygen environments. Second, the in situ self-diagnostic and self-calibration capability (two-point for oxygen) was adopted by dynamically controlling the microenvironment in close proximity to the microsensors. With a built-in generating electrode that surrounds the microsensor, two kinds of microenvironments (oxygen-saturated and oxygen-depleted phases) could be established by water electrolysis depending on the polarity of the generating electrode. The unique features of the new microsensor array (small size, multiple sensors, flexibility and self-diagnosis) can have exceptional benefits for the study and optimization of plant cultivation systems in both terrestrial and microgravity environments. The in situ self-diagnostic and self-calibration features of the microsensor array will also enable continuous verification of the operability during entire plant growth cycles. This concept of automated control of a novel chemical monitoring system will minimize crew time required for maintenance, as well as reduce volume, mass, and power consumption by eliminating bulky diagnosis systems including calibrant (fluid and gas) reservoir and flow system hardware.

Kim, Chang-Soo↗

Analyzing Responses of Chemical Sensor Arrays

NASA is developing a third-generation electronic nose (ENose) capable of continuous monitoring of the International Space Station s cabin atmosphere for specific, harmful airborne contaminants. Previous generations of the ENose have been described in prior NASA Tech Briefs issues. Sensor selection is critical in both (prefabrication) sensor material selection and (post-fabrication) data analysis of the ENose, which detects several analytes that are difficult to detect, or that are at very low concentration ranges. Existing sensor selection approaches usually include limited statistical measures, where selectivity is more important but reliability and sensitivity are not of concern. When reliability and sensitivity can be major limiting factors in detecting target compounds reliably, the existing approach is not able to provide meaningful selection that will actually improve data analysis results. The approach and software reported here consider more statistical measures (factors) than existing approaches for a similar purpose. The result is a more balanced and robust sensor selection from a less than ideal sensor array. The software offers quick, flexible, optimal sensor selection and weighting for a variety of purposes without a time-consuming, iterative search by performing sensor calibrations to a known linear or nonlinear model, evaluating the individual sensor s statistics, scoring the individual sensor s overall performance, finding the best sensor array size to maximize class separation, finding optimal weights for the remaining sensor array, estimating limits of detection for the target compounds, evaluating fingerprint distance between group pairs, and finding the best event-detecting sensors.

Zhou, Hanying↗

Fabrication and Testing of a Novel Ceramic-Based Additively Manufactured Humidity Sensor

A material capable of detecting minute changes in ambient humidity via a change in its electrical properties is critical to enabling the success of vapor-sensitive components on Earth and abroad. Manufacturing of these hydrophilic materials currently follows an extensive process of heat treating focused on removing the solvent and organic vehicle. This research aims to reduce the complexity of manufacturing these novel sensors by eliminating the high-temperature (>850 °C) processing stages. A method based on printing a polymer embedded with hydrophilic nanoparticles is accomplished through selected additively manufactured methods. This research branches into the elimination of physical spare parts with the ability to print highly sensitive in-situ sensors, reducing the environmental footprint in space-critical environments like the International Space Station (ISS).

sensor↗

Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy

Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or pixilated array of x-ray absorbers shares fewer numbers of temperature sensors. A means of discriminating the signals from different absorber positions, however, needs to be built into the device for each sensor. The design concept for the device is such that the shape of the temperature pulse with time depends on the location of the absorber. This inherent position sensitivity of the signal is then analyzed to determine the location of the event precisely, effectively yielding one device with many sub-pixels. With such devices, the total number of electronic channels required to read out a given number of pixels is significantly reduced. PoSMs were developed that consist of four discrete absorbers connected to a single magnetic sensor. The design concept can be extended to more than four absorbers per sensor. The thermal conductance between the sensor and each absorber is different by design and consequently, the pulse shapes are different depending upon which absorber the xrays are received, allowing position discrimination. A magnetic sensor was used in which a paramagnetic Au:Er temperature-sensitive material is located in a weak magnetic field. Deposition of energy from an x-ray photon causes an increase in temperature, which leads to a change of magnetization of the paramagnetic sensor, which is subsequently read out using a low noise dc-SQUID. The PoSM microcalorimeters are fully microfabricated: the Au:Er sensor is located above the meander, with a thin insulation gap in between. For this position-sensitive device, four electroplated absorbers are thermally linked to the sensor via heat links of different thermal conductance. One pixel is identical to that of a single-pixel design, consisting of an overhanging absorber fabricated directly on top of the sensor. It is therefore very strongly thermally coupled to it. The three other absorbers are supported directly on a silicon-nitride membrane. These absorbers are thermally coupled to the sensor via Ti (5 nm)/Au250 nm) metal links. The strength of the links is parameterized by the number of gold squares making up the link. For detector performance, experimentally different pulse-shapes were demonstrated with 6 keV x-rays, which clearly show different rise times for different absorber positions. For energy resolution measurement, the PoSM was operated at 32 mK with an applied field that was generated using a persistent current of 50 mA. Over the four pixels, energy resolution ranges from 4.4 to 4.7 eV were demonstrated.

Bandler, SImon↗

Nanostructured Material Sensor Processing Using Microfabrication Technology

This presentation discusses the fabrication of microsensors based based on nanomaterials and microfabrication technology. In particular, is it shown that nanostructured materials can be incorporated into standard micro fabrication techniques yielding improved alignment and electrical contact in a microsensor platform. A nano templating technique is also shown which provides sensor structures with unique properties.

chemical sensors nanostructures nanomaterials micr↗