Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Semiconductor Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Field-Induced-Gap Infrared Detectors

Semimetals become semiconductors under applied magnetic fields. New detectors require less cooling equipment because they operate at temperatures higher than liquid-helium temperatures required by extrinsic-semiconductor detectors. Magnetic fields for detectors provided by electromagnets based on recently-discovered high-transition-temperature superconducting materials. Detector material has to be semiconductor, in which photon absorbed by exciting electron/hole pair across gap Eg of forbidden energies between valence and conduction energy bands. Magnetic- and compositional-tuning effects combined to obtain two-absorber detector having narrow passband. By variation of applied magnetic field, passband swept through spectrum of interest.

Elliott, C. Thomas↗

High-purity germanium semiconductor modeling in the detector response function toolkit

In this study, we have extended the detector response function toolkit (DRiFT) to provide modeling capabilities of semiconductor sensors. DRiFT provides realistic nuclear instrumentation response by post-processing Monte-Carlo N-particle (MCNP®) radiation transport outputs. MCNP® is capable of modeling radiation transport in complex environments, but has limited detector physics and readout electronics modeling capabilities. Semiconductor detector response can be calculated with a high-fidelity for a flexible range of environments by utilizing MCNP® to simulate radiation interactions inside of detector volumes, and then using DRiFT to model charge transport and signal formation in the semiconductor, as well as the readout electronics. DRiFT models charge transport in the semiconductor, the preamplifier, shaping amplifier, pulse pile-up, and electronic noise to generate detector response. The semiconductor application in DRiFT can model a range of semiconductor materials, shapes, and sizes; and is demonstrated here for a large volume coaxial high-purity germanium (HPGe) detector. Here, we compare detector response functions of a coaxial HPGe detector with measurement of 60 Co, 133 Ba, and 137 Cs at varying count rates, and we conduct a parameter study to demonstrate the effect of changing parameters in the DRiFT simulation. The HPGe detector response function shows excellent agreement with measurements of difference sources with varying dead times and count rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication and testing of antimony doped bismuth tri-iodide semiconductor gamma-ray detectors

We fabricated antimony (Sb) doped bismuth tri-iodide (BiI 3 ) radiation detectors from large single crystals that were grown using the modified vertical Bridgman technique. Detectors were prepared by subjecting the crystal surfaces to different mechanical and chemical treatments. Surface quality of the detectors was evaluated using optical microscopy. The influence of surface quality on detector performance was analyzed by measuring the leakage current for each of the detectors. The radiation response of the detectors was measured using an Americium ( 241 Am) gamma-ray source at room temperature. The first successful use of BiI 3 detectors for gamma-ray spectroscopy is reported here with energy resolution of 7.5% at 59.5 keV. The mobility-lifetime product for electrons was also estimated to be about 5.2 x 10 -4 cm 2 /V.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IBIXFIT: A Tool For The Analysis Of Microcalorimeter PIXE Spectra

PIXE analysis software has been for long mainly tuned to the needs of Si(Li) detector based spectra analysis and quantification methods based on K{sub {alpha}} or L{sub {alpha}} X-ray lines. Still, recent evidences related to the study of relative line intensities and new developments in detection equipment, namely the emergence of commercial microcalorimeter based X-ray detectors, have brought up the possibility that in the near future PIXE will become more than just major lines quantification. A main issue that became evident as a consequence of this was the need to be able to fit PIXE spectra without prior knowledge of relative line intensities. Considering new developments it may be necessary to generalize PIXE to a wider notion of ion beam induced X-ray (IBIX) emission, to include the quantification of processes such as Radiative Auger Emission. In order to answer to this need, the IBIXFIT code was created based much on the Bayesian Inference and Simulated Annealing routines implemented in the Datafurnace code [1]. In this presentation, the IBIXFIT is used to fit a microcalorimeter spectrum of a Ba{sub x}Sr{sub (1-x)}TiO{sub 3} thin film sample and the specific possibility of selecting between fixed and free line ratios combined with other specificities of the IBIXFIT algorithm are shown to be essential to overcome the problems faced.

74 ATOMIC AND MOLECULAR PHYSICS↗

Growth and device processing of hexagonal boron nitride epilayers for thermal neutron and deep ultraviolet detectors

Solid-state neutron detectors with high performance are highly sought after for the detection of fissile materials. However, direct-conversion neutron detectors based on semiconductors with a measureable efficiency have not been realized. We report here the first successful demonstration of a direct-conversion semiconductor neutron detector with an overall detection efficiency for thermal neutrons of 4% and a charge collection efficiency as high as 83%. The detector is based on a 2.7 μm thick {sup 10}B-enriched hexagonal boron nitride (h-BN) epitaxial layer. The results represent a significant step towards the realization of practical neutron detectors based on h-BN epilayers. Neutron detectors based on h-BN are expected to possess all the advantages of semiconductor devices including wafer-scale processing, compact size, light weight, and ability to integrate with other functional devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In-situ Determination of the ATLAS Muon Performance

The ATLAS detector allows for the precise and efficient reconstruction of muons. Muon tracks are reconstructed with 97% efficiency with a momentum resolution of approximately 2-3% over most of the kinematic range and better than 10% for transverse momenta up to 1 TeV and |eta|<2.7. We present methods to measure the performance of the muon identification during the operation of the ATLAS detector using muons from Z and J/psi decays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Spectroscopic study of {sup 33}Ar

The proton-rich nucleus {sup 33}Ar has been produced at the low-energy facility SPIRAL at GANIL. Spectroscopic studies of gamma and p emission of this nucleus were performed with the 'Silicon Cube' detection system. The analysis of proton and gamma singles and coincidence spectra allowed us to establish a complete decay scheme of this nucleus. The comparison of the Gamow-Teller strength distribution deduced from our experiment and the theoretical one obtained with the Shell Model permitted the determination of a quenching factor for the Gamow-Teller strength.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Oblique incidence effects in direct x-ray detectors: A first-order approximation using a physics-based analytical model

Purpose: The authors describe the modifications to a previously developed analytical model of indirect CsI:Tl-based detector response required for studying oblique x-ray incidence effects in direct semiconductor-based detectors. This first-order approximation analysis allows the authors to describe the associated degradation in resolution in direct detectors and compare the predictions to the published data for indirect detectors. Methods: The proposed model is based on a physics-based analytical description developed by Freed et al. [''A fast, angle-dependent, analytical model of CsI detector response for optimization of 3D x-ray breast imaging systems,'' Med. Phys. 37(6), 2593-2605 (2010)] that describes detector response functions for indirect detectors and oblique incident x rays. The model, modified in this work to address direct detector response, describes the dependence of the response with x-ray energy, thickness of the transducer layer, and the depth-dependent blur and collection efficiency. Results: The authors report the detector response functions for indirect and direct detector models for typical thicknesses utilized in clinical systems for full-field digital mammography (150 {mu}m for indirect CsI:Tl and 200 {mu}m for a-Se direct detectors). The results suggest that the oblique incidence effect in a semiconductor detector differs from that in indirect detectors in two ways: The direct detector model produces a sharper overall PRF compared to the response corresponding to the indirect detector model for normal x-ray incidence and a larger relative increase in blur along the x-ray incidence direction compared to that found in indirect detectors with respect to the response at normal incidence angles. Conclusions: Compared to the effect seen in indirect detectors, the direct detector model exhibits a sharper response at normal x-ray incidence and a larger relative increase in blur along the x-ray incidence direction with respect to the blur in the orthogonal direction. The results suggest that the oblique incidence effect in direct detectors can be considered to be caused mostly by the geometry of the path where the x-ray beam and its secondary particles deposit energy in the semiconductor layer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge carrier motion and effect of fixed oxide charge in a microstructured silicon radiation detector

Signal formation in a microstructured semiconductor neutron detector is more complex than in planar diode geometry. Three-dimensional microstructures are laterally smaller than the ionization cloud length, and the electric fields may be weak enough to exhibit plasma time effects. This work is the first detailed treatment of charge carrier motion in these complex semiconductor devices to replicate the time profile and signal magnitude. Simulations were performed using COMSOL Multiphysics to investigate various parameters that affect the propagation of the charge cloud. It was observed that the size of the simulated three-dimensional structure had an impact on the induced current pulse, indicating the importance of simulation geometry optimization to accurately simulate charge cloud expansion. COMSOL Multiphysics was used to replicate accurate charge creation profiles using energy deposition information imported from radiation transport codes. A detailed simulation methodology is presented to benchmark preamplifier event pulses along with complexities in modeling the charge carrier motion along the etched microstructured trenches with Si–SiO 2 boundary conditions, including fixed oxide charge and interface trapping.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Next Generation Semiconductor-Based Radiation Detectors Using Cadmium Magnesium Telluride

The primary objective of Phase I was to perform extensive studies on the purification, crystal growth and annealing procedures of CdMgTe to gain a clear understanding of the basic material properties to enable production of detector material with performance comparable to that of CdZnTe. Brimrose utilized prior experience in the growth and processing of II-VI crystals and produced high purity material and good quality single crystals of CdMgTe. Processing techniques for these crystals including annealing, mechanical and chemical polishing, surface passivation and electrode fabrication were developed. Techniques to characterize pertinent electronic characteristics were developed and gamma ray detectors were fabricated. Feasibility of the development of comprehensive defect modeling in this new class of material was demonstrated by our partner research institute SRI International, to compliment the experimental work. We successfully produced a CdMgTe detector that showed 662 keV gamma response with energy resolution of 3.4% (FWHM) at room temperature, without any additional signal correction. These results are comparable to existing CdZnTe (CZT) technology using the same detector size and testing conditions. We have successfully demonstrated detection of gamma-radiation from various isotopes/sources, using CdMgTe thus clearly proving the feasibility that CdMgTe is an excellent, low-cost alternative to CdZnTe.

, CdTe↗

Thickness scalability of large volume cadmium zinc telluride high resolution radiation detectors

This work focuses on the thickness scalability of traveling heater method (THM) grown CdZnTe crystals to produce large volume detectors with optimized spectroscopic performance. To meet this challenge, we have tuned both our THM growth process, to grow 75 mm diameter ingots, and our postgrowth annealing process. We have increased the thickness of our sliced wafers from 6 to 12 and 18 mm allowing the production of 10 and 15 mm thick detectors. As the detectors' thickness is scaled up, the energy resolution of both types, as pseudo-Frisch grid and pixelated monolithic detectors showed no degradation indicating improved materials uniformity and transport properties.

36 MATERIALS SCIENCE↗

Investigation of the internal electric field in cadmium zinc telluride detectors using the Pockels effect and the analysis of charge transients

The Pockels electro-optic effect can be used to investigate the internal electric field in cadmium zinc telluride (CZT) single crystals that are used to fabricate room temperature x and gamma radiation detectors. An agreement is found between the electric field mapping obtained from Pockels effect images and the measurements of charge transients generated by alpha particles. The Pockels effect images of a CZT detector along two mutually perpendicular directions are used to optimize the detector response in a dual anode configuration, a device in which the symmetry of the internal electric field with respect to the anode strips is of critical importance. The Pockels effect is also used to map the electric field in a CZT detector with dual anodes and an attempt is made to find a correlation with the simulated electric potential in such detectors. Finally, the stress-induced birefringence effects seen in the Pockels images are presented and discussed.

36 MATERIALS SCIENCE↗

Polarization Sensitivity of the DAGATA Polarimeter

In comparison to common Compton Polarimeters the DAGATA (Darmstadt GAmma-ray Tracking Assembly) polarimeter will significantly enhance the sensitivity for gamma-rays above 4 MeV making use of its large volume 36-fold segmented HPGe AGATA crystal and the resulting superior position resolution. Results from Monte Carlo Simulations will be presented as well as approaches for data analysis to further improve the sensitivity. Application limits and realistic simulated spectra will be compared to results from existing polarimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluctuations in induced charge introduced by Te inclusions within CdZnTe radiation detectors

Recently, homogenization theory based on a multiple-scale perturbation of the electron transport equation has been used to derive a mathematical framework for modeling the excess charge lost to Te inclusions within radiation detectors based on semi-insulating cadmium zinc telluride (CdZnTe). In that theory, the heterogeneous material is mathematically replaced by a homogenized CdZnTe crystal whose effective electron attenuation length incorporates the additional uniform electron trapping caused by the inclusions. In this paper, the homogenization theory is extended to incorporate fluctuations in the induced charge (i.e., charge collection nonuniformities) introduced by the random position and size distributions of a noncorrelated population of small (i.e, <20 {mu}m) Te inclusions. Analysis of the effective parameters derived within the homogenized framework is used to develop a probability distribution of effective electron attenuation lengths, and therefore effective mobility-lifetime products, as a function of both the position and size distribution of Te inclusions. Example distributions are detailed for the case of an exponential size distribution at various number densities. Further, it is demonstrated that the inclusion-induced material nonuniformities derived in this paper can be numerically sampled efficiently, making them applicable to Monte Carlo device simulation of realistic CdZnTe detectors. Simulated charge induction maps and pulse-height spectra are presented and compared to recently published measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear radiation detectors based on a matrix of ion-implanted p-i-n diodes on undoped GaAs epilayers

Samples of nuclear detectors which represent matrices of p-i-n diodes were fabricated based on undoped gallium arsenide epitaxial layers by ion implantation technology. The detectors have a size of the active area of 0.4 Multiplication-Sign 0.4 and 0.9 Multiplication-Sign 0.9 cm{sup 2}. Electrical characteristics of fabricated detectors and results of measurements of fast neutrons spectra of {sup 241}Am-Be source by the recoil protons method are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Position-Sensitive Nuclear Spectroscopy with Pixel Detectors

State-of-the-art hybrid semiconductor pixel detectors such as Medipix2 are suitable for energy- and position-sensitive nuclear spectroscopy. In addition to excellent energy- and spatial-resolution, these devices can operate in spectroscopic, single-quantum counting and/or on-line tracking mode. A devoted compact USB-readout interface provides functionality and ease of operation. The compact and versatile Medipix2/USB radiation camera provides visualization, vacuum and room-temperature operation as a real-time portable active nuclear emulsion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution measurement of absolute {alpha}-decay widths in {sup 16}O

By using a large-acceptance position-sensitive silicon detector array in coincidence with the high-resolution Munich Q3D spectrograph, unambiguous measurements have been made of the absolute {alpha}-particle decay widths from excited states in {sup 16}O* in the energy range 13.85 to 15.87 MeV. Carbon targets have been bombarded with 42-MeV {sup 6}Li beams to induce {sub 6}{sup 12}C({sub 3}{sup 6}Li, d){sub 8}{sup 16}O* reactions. The deuteron ejectiles were measured in the Q3D and the results gated by {sup 4}He+{sup 12}C breakup products detected in the silicon array, the efficiency of which was modeled using Monte Carlo simulations. By comparing total population and breakup-gated spectra, the following absolute {alpha}-decay widths have been measured with high resolution: {Gamma}{sub {alpha}}0/{Gamma}{sub tot} = 0.87{+-}0.11 (13.980 MeV), 1.04{+-}0.15 (14.302 MeV), 0.92{+-}0.10 (14.399 MeV), 0.59{+-}0.04 (14.815 MeV), 0.88{+-}0.18 (15.785 MeV), and {Gamma}{sub {alpha}}1/{Gamma}{sub tot}=1.14{+-}0.08 (14.660 MeV), 0.46{+-}0.06 (14.815 MeV).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗