Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Schwarz methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Late transient acceleration of the universe in string theory on S{sup 1}/Z{sub 2}

Recently, in Gong et al (2008 Phys. Lett. B 663 147 [arXiv:0711.1597]) and Wang and Santos (2007 arXiv:0712.3938) we showed that the effective cosmological constant on each of the two orbifold branes can be easily lowered to its current observational value, by using the large extra dimensions in the framework of both M-theory and string theory on S{sup 1}/Z{sub 2}. In this paper, we study the current acceleration of the universe, using the formulae developed in Wang and Santos (2007 arXiv:0712.3938). We first construct explicitly a time-dependent solution to the ten-dimensional bulk of the Neveu-Schwarz/Neveu-Schwarz sector, compactified on a five-dimensional torus. Then, we write down the generalized Friedmann equations on each of the two dynamical branes, and fit the models to the 182 gold Supernova Ia data and the BAO parameter from SDSS, using both of our MINUIT and Monte Carlo Markov Chain (MCMC) codes. With the best fitting values of the parameters involved as initial conditions, we integrate the generalized Friedmann equations numerically and find the future evolution of the universe. We find that it depends on the choice of the radion potentials V{sub 4}{sup (I)} (I = 1,2) of the branes. In particular, when choosing them to be Goldberger-Wise potentials, V{sub 4}{sup (I)} = {lambda}{sub 4}{sup (I)}({psi}{sup 2}-v{sub I}{sup 2}){sup 2}, we find that the current acceleration of the universe driven by the effective cosmological constant is only temporary. Due to the effects of the potentials, the universe will finally be in its decelerating expansion phase again. We also study the proper distance between the two branes and find that it remains almost constant during the whole future evolution of the universe in all the models considered.

79 ASTRONOMY AND ASTROPHYSICS↗

BICEP/Keck. XX. Component-separated Maps of the Polarized Cosmic Microwave Background and Thermal Dust Emission Using Planck and BICEP/Keck Observations through the 2018 Observing Season

We present component-separated polarization maps of the cosmic microwave background (CMB) and Galactic thermal dust emission, derived using data from the BICEP/Keck experiments through the 2018 observing season and Planck. By employing a maximum-likelihood method that utilizes observing matrices, we produce unbiased maps of the CMB and dust signals. We outline the computational challenges and demonstrate an efficient implementation of the component map estimator. We show methods to compute and characterize power spectra of these maps, opening up an alternative way to infer the tensor-to-scalar ratio from our data. We compare the results of this map-based separation method with the baseline BICEP/Keck analysis. Our analysis demonstrates consistency between the two methods, finding an 84% correlation between the pipelines.

cosmic inflation↗

A framework to combine low- and high-resolution spectroscopy for the atmospheres of transiting exoplanets

Current observations of the atmospheres of close-in exoplanets are predominantly obtained with two techniques: low-resolution spectroscopy with space telescopes and high-resolution spectroscopy from the ground. Although the observables delivered by the two methods are in principle highly complementary, no attempt has ever been made to combine them, perhaps due to the different modeling approaches that are typically used in their interpretation. Here, we present the first combined analysis of previously published dayside spectra of the exoplanet HD 209458 b obtained at low resolution with HST/Wide Field Camera 3 (WFC3) and Spitzer/IRAC and at high resolution with VLT/CRIRES. By utilizing a novel retrieval algorithm capable of computing the joint probability distribution of low- and high-resolution spectra, we obtain tight constraints on the chemical composition of the planet’s atmosphere. In contrast to the WFC3 data, we do not confidently detect H{sub 2}O at high spectral resolution. The retrieved water abundance from the combined analysis deviates by 1.9σ from the expectations for a solar-composition atmosphere in chemical equilibrium. Measured relative molecular abundances of CO and H{sub 2}O strongly favor an oxygen-rich atmosphere (C/O < 1 at 3.5σ) for the planet when compared to equilibrium calculations including O rainout. From the abundances of the seven molecular species included in this study we constrain the planet metallicity to 0.1–1.0× the stellar value (1σ). This study opens the way to coordinated exoplanet surveys between the flagship ground- and space-based facilities, which ultimately will be crucial for characterizing potentially habitable planets.

79 ASTRONOMY AND ASTROPHYSICS↗

Depth‐dependent concentrations of hematopoietic stem cells in the adult skeleton: Implications for active marrow dosimetry

Purpose The hematopoietically active (or red) bone marrow is the target tissue assigned in skeletal dosimetry models for assessment of stochastic effects (leukemia induction) as well as tissue reactions (marrow toxicity). Active marrow, however, is in reality a surrogate tissue region for specific cell populations, namely the hematopoietic stem and progenitor cells. Present models of active marrow dosimetry implicitly assume that these cells are uniformly localized throughout the marrow spaces of trabecular spongiosa. Data from Watchman et al. and Bourke et al., however, clearly indicate that there is a substantial spatial concentration gradient of these cells with the highest concentrations localized near the bone trabeculae surfaces. The purpose of the present study was thus to explore the dosimetric implications of these spatial gradients on active marrow dosimetry. Methods Images of several bone sites from a 45‐yr female were retagged to group active marrow voxels into 50 μm increments of marrow depth, after which electron and alpha‐particle depth‐dependent specific absorbed fractions were computed for four source tissues — active marrow, inactive marrow, bone trabeculae volumes, and bone trabeculae surfaces. Corresponding depth‐dependent S values (dose to a target tissue per decay in a source tissue) were computed and further weighted by the relative target cell concentration. These depth‐weighted radionuclide S values were systematically compared to the more traditional volume‐averaged radionuclide S values of the MIRD schema for both individual bones of the skeleton and their skeletal‐averaged quantities. Results For both beta‐emitters and alpha‐emitters localized in the active and inactive marrow, depth‐weighted S values were shown to differ from volume‐averaged S values by only a few percent, as dose gradients across the marrow tissues are nonexistent. For bone volume and bone surface sources of alpha‐emitters and lower energy beta‐emitters, when marrow dose gradients are expected, explicit consideration of target cell spatial concentration gradients are shown to significantly impact marrow dosimetry. Conclusions For medical isotopes currently utilized for treatment of skeletal metastases, namely 153 Sm and 223 Ra, accounting for hematopoietic stem and progenitor cell concentration gradients resulted in maximum percent differences to reference skeletal‐averaged S values of ~21% and 55%, respectively.

Geyer, Amy M.↗

Search for heavy long-lived charged particles with large ionization energy loss in proton-proton collisions at $$ \sqrt{s} $$ = 13 TeV

Abstract A search for heavy, long-lived, charged particles with large ionization energy loss within the silicon tracker of the CMS experiment is presented. A data set of proton-proton collisions at a center of mass energy at $$ \sqrt{s} $$ s = 13 TeV, collected in 2017 and 2018 at the CERN LHC, corresponding to an integrated luminosity of 101 fb −1, is used in this analysis. Two different approaches for the search are taken. A new method exploits the independence of the silicon pixel and strips measurements, while the second method improves on previous techniques using ionization to determine a mass selection. No significant excess of events above the background expectation is observed. The results are interpreted in the context of the pair production of supersymmetric particles, namely gluinos, top squarks, and tau sleptons, and of the Drell-Yan pair production of fourth generation (τ′) leptons with an electric charge equal to or twice the absolute value of the electron charge (e). An interpretation of a Z’ boson decaying to two τ′ leptons with an electric charge equal to 2e is presented for the first time. The 95% confidence upper limits on the production cross section are extracted for each of these hypothetical particles.

Hayrapetyan, A. [Yerevan Physics Institute]↗

Search for heavy long-lived charged particles with large ionization energy loss in proton-proton collisions at $\sqrt{s}$ = 13 TeV

A search for heavy, long-lived, charged particles with large ionization energy loss within the silicon tracker of the CMS experiment is presented. A data set of proton-proton collisions at a center of mass energy at $\sqrt{s}$ = 13 TeV, collected in 2017 and 2018 at the CERN LHC, corresponding to an integrated luminosity of 101 fb −1 , is used in this analysis. Two different approaches for the search are taken. A new method exploits the independence of the silicon pixel and strips measurements, while the second method improves on previous techniques using ionization to determine a mass selection. No significant excess of events above the background expectation is observed. The results are interpreted in the context of the pair production of supersymmetric particles, namely gluinos, top squarks, and tau sleptons, and of the Drell-Yan pair production of fourth generation (τ′) leptons with an electric charge equal to or twice the absolute value of the electron charge (e). An interpretation of a Z’ boson decaying to two τ′ leptons with an electric charge equal to 2e is presented for the first time. The 95% confidence upper limits on the production cross section are extracted for each of these hypothetical particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Breeding progress and preparedness for mass‐scale deployment of perennial lignocellulosic biomass crops switchgrass, miscanthus, willow and poplar

Abstract Genetic improvement through breeding is one of the key approaches to increasing biomass supply. This paper documents the breeding progress to date for four perennial biomass crops (PBCs) that have high output–input energy ratios: namely Panicum virgatum (switchgrass), species of the genera Miscanthus (miscanthus), Salix (willow) and Populus (poplar). For each crop, we report on the size of germplasm collections, the efforts to date to phenotype and genotype, the diversity available for breeding and on the scale of breeding work as indicated by number of attempted crosses. We also report on the development of faster and more precise breeding using molecular breeding techniques. Poplar is the model tree for genetic studies and is furthest ahead in terms of biological knowledge and genetic resources. Linkage maps, transgenesis and genome editing methods are now being used in commercially focused poplar breeding. These are in development in switchgrass, miscanthus and willow generating large genetic and phenotypic data sets requiring concomitant efforts in informatics to create summaries that can be accessed and used by practical breeders. Cultivars of switchgrass and miscanthus can be seed‐based synthetic populations, semihybrids or clones. Willow and poplar cultivars are commercially deployed as clones. At local and regional level, the most advanced cultivars in each crop are at technology readiness levels which could be scaled to planting rates of thousands of hectares per year in about 5 years with existing commercial developers. Investment in further development of better cultivars is subject to current market failure and the long breeding cycles. We conclude that sustained public investment in breeding plays a key role in delivering future mass‐scale deployment of PBCs.

09 BIOMASS FUELS↗

High-precision mass measurements of the isomeric and ground states of 44 V: Improving constraints on the isobaric multiplet mass equation parameters of the A=44, 0 + quintet

Background: The quadratic isobaric multiplet mass equation (IMME) has been very successful at predicting the masses of isobaric analog states in the same multiplet, while its coefficients are known to follow specific trends as functions of mass number. The Atomic Mass Evaluation 2016 [Chin. Phys. C 41, 030003 (2017)] 44 V mass value results in an anomalous negative c coefficient for the IMME quadratic term; a consequence of large uncertainty and an unresolved isomeric state. The b and c coefficients can provide useful constraints for construction of the isospin-nonconserving Hamiltonians for the pf shell. In addition, the excitation energy of the 0 + , T = 2 level in 44 V is currently unknown. This state can be used to constrain the mass of the more exotic 44 Cr. Purpose: The aim of the experimental campaign was to perform high-precision mass measurements to resolve the difference between 44 V isomeric and ground states, to test the IMME using the new ground state mass value and to provide necessary ingredients for the future identification of the 0 + , T = 2 state in 44 V. Method: High-precision Penning trap mass spectrometry was performed at LEBIT, located at the National Superconducting Cyclotron Laboratory, to measure the cyclotron frequency ratios of [ 44g,m VO] + versus [ 32 SCO] + , a well-known reference mass, to extract both the isomeric and ground state masses of 44 V. Results: The mass excess of the ground and isomeric states in 44 V were measured to be -23 804.9(80) keV/c 2 and -23 537.0(55) keV/c 2 , respectively. This yielded a new proton separation energy of S p = 1 773(10) keV. Conclusion: The new values of the ground state and isomeric state masses of 44 V have been used to deduce the IMME b and c coefficients of the lowest 2 + and 6 + triplets in A = 44. The 2 + c coefficient is now verified with the IMME trend for lowest multiplets and is in good agreement with the shell-model predictions using charge-dependent Hamiltonians. The mirror energy differences were determined between 44 V and 44 Sc, in line with isospin-symmetry for this multiplet. Finally, the new value of the proton separation energy determined, to an uncertainty of 10 keV, will be important for the determination of the 0 + , T = 2 state in 44 V and, consequently, for prediction of the mass excess of 44 Cr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A method for correcting the substructure of multiprong jets using the Lund jet plane

Many analyses at the CERN LHC exploit the substructure of jets to identify heavy resonances produced with high momenta that decay into multiple quarks and/or gluons. This paper presents a new technique for correcting the substructure of simulated large-radius jets from multiprong decays. The technique is based on reclustering the jet constituents into several subjets such that each subjet represents a single prong, and separately correcting the radiation pattern in the Lund jet plane of each subjet using a correction derived from data. The data presented here correspond to an integrated luminosity of 138 fb −1 collected by the CMS experiment between 2016–2018 at a center-of-mass energy of 13 TeV. The correction procedure improves the agreement between data and simulation for several different substructure observables of multiprong jets. This technique establishes, for the first time, a robust calibration for the substructure of jets with four or more prongs, enabling future measurements and searches for new phenomena containing these signatures.

Hadron-Hadron Scattering↗

MO-FG-CAMPUS-JeP1-04: Evaluating DECT Vs SECT Range Differences in Proton Therapy Using Clinical Data

Purpose: Range uncertainty from X-ray CT number conversion to stopping power ratio (SPR) is one of the key factors limiting the potential of proton therapy. The large margins required for deep seated tumors degrade the organ sparing achievable with the technology. Of interest is the application of dual energy CT (DECT) to SPR estimation. In this planning study proton range differences between SECT and DECT have been quantified for brain cases. Methods: A last generation dual source DECT scanner was used to acquire SECT (150 kVp with Sn filtration) and DECT (additionally 90 kVp) scans of phantoms and 5 head trauma patients, acting as surrogate cancer patients. Phantom materials were characterized in terms of SPR in a particle beam to obtain reference values. IMPT treatment plans were generated on the basis of SECT and DECT SPR images for hypothetical brain tumors using a short and a long beam path. Range differences between SECT and DECT from plan recalculations were evaluated in beam-eye-view (BEV) by comparing the 80% isodose. Results: For the 18 phantom materials the SECT RMS SPR errors were 2.6% compared to 1.1% for DECT. Group median relative range differences between SECT and DECT plans were −1.0% for the short beam path over the 5 patients investigated in this study. For the long beam path the median difference was −1.4%. These relative range differences corresponded to −0.5 mm and −1.4 mm shifts respectively. Conclusion: This is the first study performing proton therapy treatment planning on DECT patient images. Important range differences of more than 1 mm were observed between SECT and DECT treatment plans, and DECT SPR accuracy was found superior on the basis of phantom measurements. While the patients investigated in this study did not have brain tumors, the findings we observed should apply to cancer patients. Deutsche Forschungsgemeinschaft (MAP); Bundesministerium fur Bildung und Forschung (01IB13001)

60 APPLIED LIFE SCIENCES↗

Multiscale Electricity Modeling for Evaluating Carbon Capture and Sequestration Technologies (Final Report)

Carbon capture and sequestration (CCS) technologies that can operate with a high degree of operating flexibility could provide necessary electric grid flexibility in a system with high shares of variable renewables. This project examines the deployment and dispatch potential of twelve unique flexible CCS (FLECCS) technologies that encompass post-combustion carbon dioxide (CO 2 ) capture designs, concepts using a storage media to enable energy arbitrage, and hybrid processes that integrate CCS with direct air capture (DAC) for flexibility with net zero or negative CO 2 emissions. FLECCS technology potential is explored with a multi-model, multi-scale framework including the Regional Energy Deployment System (ReEDS) electric sector capacity expansion model (CEM) and the PLEXOS production cost model (PCM). Innovative methods were developed to represent FLECCS technology operating modes, performance, and cost in the two models. ReEDS was then used to simulate nine scenarios for each FLECCS technology, three CO 2 emissions price futures reaching $\$$150, $\$$225, and $\$$300/tCO 2 in 2050; and three scenarios for FLECCS technology deployment favorability relative to competing technologies. For each CO 2 price and reference FLECCS favorability, the 2050 infrastructures from ReEDS model are downscaled and implemented in PLEXOS to examine hourly dispatch under detailed operational constraints that are not included in ReEDS. FLECCS technologies exhibited a wide range of deployment potential ranging from none to several hundred gigawatts of capacity, with outcomes highly sensitive to input cost and performance parameters that are inherently highly uncertain. When deployed, FLECCS tended to displace a combination of wind, solar, and natural gas-based technologies rather than supporting increased renewable deployment. As a result, CO 2 emissions reductions facilitated by FLECCS deployment tended to come with higher overall system costs and electricity prices. When economically competitive, FLECCS technologies can contribute significant flexible generation and firm capacity to the grid, but continued technology development and an expanded analytical scope are necessary to fully understand FLECCS deployment potential its impact on the electric power sector. Follow-on analysis incorporating captured CO 2 tax credit value from the Inflation Reduction Act (IRA) and other potential policy scenarios could be particularly valuable, as this policy can substantially change the relative competitiveness of FLECCS technologies.

03 NATURAL GAS↗

Harmonizing tau positron emission tomography in Alzheimer's disease: The CenTauR scale and the joint propagation model

Abstract INTRODUCTION Tau‐positron emission tomography (PET) outcome data of patients with Alzheimer's disease (AD) cannot currently be meaningfully compared or combined when different tracers are used due to differences in tracer properties, instrumentation, and methods of analysis. METHODS Using head‐to‐head data from five cohorts with tau PET radiotracers designed to target tau deposition in AD, we tested a joint propagation model (JPM) to harmonize quantification (units termed “CenTauR” [CTR]). JPM is a statistical model that simultaneously models the relationships between head‐to‐head and anchor point data. JPM was compared to a linear regression approach analogous to the one used in the amyloid PET Centiloid scale. RESULTS A strong linear relationship was observed between CTR values across brain regions. Using the JPM approach, CTR estimates were similar to, but more accurate than, those derived using the linear regression approach. DISCUSSION Preliminary findings using the JPM support the development and adoption of a universal scale for tau‐PET quantification. Highlights Tested a novel joint propagation model (JPM) to harmonize quantification of tau PET. Units of common scale are termed “CenTauRs”. Tested a Centiloid‐like linear regression approach. Using five cohorts with head‐to‐head tau PET, JPM outperformed linearregressionbased approach. Strong linear relationship was observed between CenTauRs values across brain regions.

Neurosciences & Neurology↗

{sup 18}-F-Fluorodeoxyglucose-Positron Emission Tomography Evaluation of Early Metabolic Response During Radiation Therapy for Cervical Cancer

Purpose: To document changes in cervical tumor {sup 18}-F-fluorodeoxyglocose (FDG) uptake during radiation therapy and to correlate those changes with post-treatment tumor response and survival outcome. Methods and Materials: A total of 36 patients with Stage Ib1 to IIIb cervical cancer were enrolled in an institutional protocol examining the use of fluorodeoxyglucose-positron emission tomography (FDG-PET) for brachytherapy treatment planning. As part of this study, FDG-PET or PET/computed tomograpy (CT) images were obtained before, during, and after the completion of radiation therapy. Tumor metabolic responses were assessed qualitatively and semi-quantitatively by measurement of the maximal standardized uptake value (SUV{sub max}). Results: Post-treatment FDG-PET images were obtained for 36 patients in this study. Of the patients, 29 patients had a complete metabolic response on the post-treatment PET, 4 had a partial metabolic response, and 3 had new sites of FDG uptake. Six patients had a complete metabolic response observed during radiation therapy, 26 had a partial metabolic response and 4 had stable or increased tumor metabolic activity. For patients with complete metabolic response during radiation therapy, median time to complete response was 29.5 days (range, 18-43 days). The mean cervical tumor SUV{sub max} decreased from 11.2 (SD, 6.3; range, 2.1-38.0) pretreatment to 2.4 (SD, 2.7; range, 0-8.8) mid treatment, and 0.5 (SD, 1.7; range, 0-8.3) post-treatment. Conclusions: During radiation therapy for cervical cancer, FDG-PET can be used to monitor treatment response. Complete metabolic response during radiation therapy was observed for a subset of patients. Recommendations regarding the optimal timing of FDG-PET during treatment for cervical cancer will require further systematic study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of systematic uncertainty-aware neural network trainings for binned-likelihood analyses at the LHC

We propose a neural network training method capable of accounting for the effects of systematic variations of the data model in the training process and describe its extension towards neural network multiclass classification. The procedure is evaluated on the realistic case of the measurement of Higgs boson production via gluon fusion and vector boson fusion in the τ τ decay channel at the CMS experiment. The neural network output functions are used to infer the signal strengths for inclusive production of Higgs bosons as well as for their production via gluon fusion and vector boson fusion. We observe improvements of 12 and 16% in the uncertainty in the signal strengths for gluon and vector-boson fusion, respectively, compared with a conventional neural network training based on cross-entropy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cervical Gross Tumor Volume Dose Predicts Local Control Using Magnetic Resonance Imaging/Diffusion-Weighted Imaging—Guided High-Dose-Rate and Positron Emission Tomography/Computed Tomography—Guided Intensity Modulated Radiation Therapy

Purpose: Magnetic resonance imaging/diffusion weighted-imaging (MRI/DWI)-guided high-dose-rate (HDR) brachytherapy and {sup 18}F-fluorodeoxyglucose (FDG) — positron emission tomography/computed tomography (PET/CT)-guided intensity modulated radiation therapy (IMRT) for the definitive treatment of cervical cancer is a novel treatment technique. The purpose of this study was to report our analysis of dose-volume parameters predicting gross tumor volume (GTV) control. Methods and Materials: We analyzed the records of 134 patients with International Federation of Gynecology and Obstetrics stages IB1-IVB cervical cancer treated with combined MRI-guided HDR and IMRT from July 2009 to July 2011. IMRT was targeted to the metabolic tumor volume and lymph nodes by use of FDG-PET/CT simulation. The GTV for each HDR fraction was delineated by use of T2-weighted or apparent diffusion coefficient maps from diffusion-weighted sequences. The D100, D90, and Dmean delivered to the GTV from HDR and IMRT were summed to EQD2. Results: One hundred twenty-five patients received all irradiation treatment as planned, and 9 did not complete treatment. All 134 patients are included in this analysis. Treatment failure in the cervix occurred in 24 patients (18.0%). Patients with cervix failures had a lower D100, D90, and Dmean than those who did not experience failure in the cervix. The respective doses to the GTV were 41, 58, and 136 Gy for failures compared with 67, 99, and 236 Gy for those who did not experience failure (P<.001). Probit analysis estimated the minimum D100, D90, and Dmean doses required for ≥90% local control to be 69, 98, and 260 Gy (P<.001). Conclusions: Total dose delivered to the GTV from combined MRI-guided HDR and PET/CT-guided IMRT is highly correlated with local tumor control. The findings can be directly applied in the clinic for dose adaptation to maximize local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Search for top squarks in final states with many light-flavor jets and 0, 1, or 2 charged leptons in proton-proton collisions at $\sqrt{s}=13$ TeV

Several new physics models including versions of supersymmetry (SUSY) characterized by R-parity violation (RPV) or with additional hidden sectors predict the production of events with top quarks, low missing transverse momentum, and many additional quarks or gluons. The results of a search for top squarks decaying to two top quarks and six additional light-flavor quarks or gluons are reported. The search employs a novel machine learning method for background estimation from control samples in data using decorrelated discriminators. The search is performed using events with 0, 1, or 2 electrons or muons in conjunction with at least six jets. No requirement is placed on the magnitude of the missing transverse momentum. The result is based on a sample of proton-proton collisions at $\sqrt{s}=13$ TeV corresponding to 138 fb −1 of integrated luminosity collected with the CMS detector at the LHC in 2016–2018. With no statistically significant excess of events observed beyond the expected contributions from the standard model, the data are used to determine upper limits on the top squark pair production cross section in the frameworks of RPV and stealth SUSY. Models with top squark masses less than 700 (930) GeV are excluded at 95% confidence level for RPV (stealth) SUSY scenarios.

Hadron-Hadron Scattering↗

Helical Tomotherapy vs. Intensity-Modulated Proton Therapy for Whole Pelvis Irradiation in High-Risk Prostate Cancer Patients: Dosimetric, Normal Tissue Complication Probability, and Generalized Equivalent Uniform Dose Analysis

Purpose: To compare intensity-modulated proton therapy (IMPT) and helical tomotherapy (HT) treatment plans for high-risk prostate cancer (HRPCa) patients. Methods and Materials: The plans of 8 patients with HRPCa treated with HT were compared with IMPT plans with two quasilateral fields set up (-100{sup o}; 100{sup o}) and optimized with the Hyperion treatment planning system. Both techniques were optimized to simultaneously deliver 74.2 Gy/Gy relative biologic effectiveness (RBE) in 28 fractions on planning target volumes (PTVs)3-4 (P + proximal seminal vesicles), 65.5 Gy/Gy(RBE) on PTV2 (distal seminal vesicles and rectum/prostate overlapping), and 51.8 Gy/Gy(RBE) to PTV1 (pelvic lymph nodes). Normal tissue calculation probability (NTCP) calculations were performed for the rectum, and generalized equivalent uniform dose (gEUD) was estimated for the bowel cavity, penile bulb and bladder. Results: A slightly better PTV coverage and homogeneity of target dose distribution with IMPT was found: the percentage of PTV volume receiving {>=}95% of the prescribed dose (V{sub 95%}) was on average >97% in HT and >99% in IMPT. The conformity indexes were significantly lower for protons than for photons, and there was a statistically significant reduction of the IMPT dosimetric parameters, up to 50 Gy/Gy(RBE) for the rectum and bowel and 60 Gy/Gy(RBE) for the bladder. The NTCP values for the rectum were higher in HT for all the sets of parameters, but the gain was small and in only a few cases statistically significant. Conclusions: Comparable PTV coverage was observed. Based on NTCP calculation, IMPT is expected to allow a small reduction in rectal toxicity, and a significant dosimetric gain with IMPT, both in medium-dose and in low-dose range in all OARs, was observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative impact of changes in marrow cellularity, skeletal size, and bone mineral density on active marrow dosimetry based upon a reference model

Purpose The hematopoietically active tissues of skeletal bone marrow are a prime target for computational dosimetry given potential risks of leukemia and, at higher dose levels, acute marrow toxicity. The complex three‐dimensional geometry of trabecular spongiosa, however, complicates schema for dose assessment in such a way that only a few reference skeletal models have been developed to date, and which are based upon microimaging of a limited number of cadaveric bone spongiosa cores. The question then arises as to what degree of accuracy is achievable from reference skeletal dose models when applied to individual patients or specific exposed populations? Methods Patient variability in marrow dosimetry were quantified for three skeletal sites — the ribs, lumbar vertebrae, and cranium — for the beta‐emitters 45 Ca, 153 Sm, and 90 Y, and the alpha‐particle emitters 223 Ra, 219 Rn, and 215 Po, the latter two being the immediate progeny of the former. For each radionuclide and bone site, three patient parameters were altered from their values in the reference model: (1) bone size as a surrogate for patient stature, (2) marrow cellularity as a surrogate for age‐ or disease‐related changes in marrow adiposity, and (3) the trabecular bone volume fraction as a surrogate for bone mineral density. Marrow dose variability is expressed as percent differences in the radionuclide S value given by the reference model and the patient‐parameterized model. The impact of radionuclide biokinetics on marrow dosimetry was not considered. Results Variations in overall bone size play a very minor role in active marrow dose variability. Marrow cellularity is a significant factor in dose variability for active marrow self‐irradiation, but it plays no role for radionuclides localized to the trabecular bone matrix. Variations in trabecular bone volume fractions impact the active marrow dose variability for short‐range particle emitters 45 Ca, 223 Ra, 219 Rn, and 215 Po in the vertebrae and ribs, skeletal sites with small spongiosa proportions of trabecular bone. In the cranium, with its relative high proportion of trabecular bone, significant differences in marrow dosimetry from the reference model were noted for all radionuclides. Conclusions Skeletal models of active marrow dosimetry should be more fully parameterized to permit closer matching to patient bone density and marrow cellularity, particularly when considering short‐range particle emitters localized to either the bone trabeculae or active marrow, respectively.

Geyer, Amy M.↗