Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scanning Electron Microscopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Recombination-active defects in silicon ribbon and polycrystalline solar cells

This paper reports results from a study of recombination-active structural defects in silicon ribbon and polycrystalline solar cells using the electron beam induced current (EBIC) technique in a scanning electron microscope. It is demonstrated that low temperature EBIC measurements can reveal a range of defects that are not observable at room temperature, including slip dislocations in silicon dendritic web ribbons as well as decorated twin boundaries and dislocation complexes in cast polycrystalline silicon solar cell materials.

Cheng, L. J.↗

Lunar sample 14425 - Corrected analysis

A polished section of lunar sample 14425, an 8 mm glass bead, was studied using a scanning electron microscope and energy-dispersive X-ray analyzer. The silicon, aluminum, iron, magnesium, calcium, sodium, potassium, titanium, and chromium contents of the glass were determined. Two types of glass are visible in the polished section. One is clear and almost devoid of metallic spherules, while the other is cloudy and contains numerous metallic spherules, some less than one micron in size. Both glass types are homogeneous and identical in composition. This composition closely matches that of some Apollo 14 breccias or glass found in the breccias. The apparent similarity in composition between lunar sample 14425 and the high-magnesium microtektites found in a previous study was probably due to charging effects during analyses in which the sample was uncoated.

Glass, B. P.↗

Effects of real-time thermal aging on graphite/polyimide composites

As part of a program to evaluate high-temperature advanced composites for use on supersonic cruise transport aircraft, two graphite/polyimide composites have been aged at elevated temperatures for times up to 5.7 years. Work on the first, HT-S/710 graphite/polyimide, was started in 1974. Evaluation of the second polyimide, Celion 6000/LARC-160, began in 1980. Baseline properties are presented, including unnotched and notched tensile data as a function of temperature, compression, flexure, shear, and constant-amplitude fatigue data at R = 0.1 and R = -1. Tensile specimens were aged in ovens where pressure and aging temperatures were controlled for various times up to and including 50,000 hours. Changes in tensile strength were determined and plotted as a function of aging time. The HT-S/710 composite aged at 450 F and 550 F if compared to the Celion 6000/LARC-160 composite aged at 350 F and 450 F. After tensile testing, many of the thermal aging specimens were examined using a scanning electron microscope. Results of these studies are presented, and changes in properties and degradation mechanisms during high-temperature aging are discussed and illustrated using metallographic techniques.

Haskins, J. F.↗

Mechanical properties testing of candidate polymer matrix materials for use in high performance composites

The mechanical properties of four candidate neat resin systems for use in graphite/epoxy composites are characterized. This includes tensile and shear stiffnesses and strengths, coefficients of thermal and moisture expansion, and fracture toughness. Tests are conducted on specimens in the dry state and moisture-saturated, at temperatures of 23C, 82C and 121C. The neat resins tested are Hexcel HX-1504, Narmco 5245-C, American Cyanamid CYCOM 907, and Union Carbide ERX-4901A (MDA). Results are compared with those obtained for four other epoxy resins tested in a prior program, i.e., Hercules 3502, 2220-1, and 2220-3, and Ciba-Geigy Fibredux 914, as well as with available Hercules 3501-6 data. Scanning electron microscopic examination of fracture surfaces is performed to permit the correlation of observed failure modes with the environmental test conditions. A finite element micromechanics analysis is used to predict unidirectional composite response under various test conditions, using the measured neat resin properties as input data.

Zimmerman, R. S.↗

Fracture morphology of 2-D carbon-carbon composition

Out-of-plane tensile tests of a woven fabric carbon-carbon composite were performed in a scanning electron microscope equipped with a tensile stage and a videotape recording system. The composite was prepared from T-300 8-harness satin graphite fabric and a phenolic resin. The (0/90/0/90/0 sub 1/2) sub 2 laminate, with a Theta describing the orientation of the warp fibers of the fabric, was cured at 160 C and pyrolized at 871 C. This was followed by four cycles of resin impregnation, curing, and pyrolysis. A micrograph of the cross section of the composite is presented. Inspection of the specimen fracture surface revealed that the filaments had no residual matrix bonded to them. Further inspection revealed that the fracture was interlaminar in nature. Failure occurred where filaments of adjacent plies had the same orientation. Thus it is postulated that improvement in transverse tensile strength of 2-D carbon-carbon depends on the improvement of the filament-matrix bond strength.

Avery, W. B.↗

Surface film effects on drop tube undercooling studies

The effects of various gaseous atmospheric constituents on drop-tube solidified samples of elemental metals were examined from a microstructural standpoint. All specimens were prepared from the purest available elements, so effects of impurities should not account for the observed effects. The drop-tube gas has a definite effect on the sample microstructure. Most dramatically, the sample cooling rate is effected. Some samples receive sufficient cooling to solidify in free fall while others do not, splating at the end of the drop tube in the sample catcher. Gases are selectively absorbed into the sample. Upon solidification gas can become less soluble and as a result forms voids within the sample. The general oxidation/reduction characteristics of the gas also affect sample microstructures. In general, under the more favorable experimental conditions including reducing atmospheric conditions and superheatings, examination of sample microstructures indicates that nucleation has been suppressed. This is indicated by underlying uniform dendrite spacings throughout the sample and with a single dendrite orientation through most of the sample. The samples were annealed yielding a few large grains and single or bi-crystal samples were commonly formed. This was especially true of samples that were inadvertently greatly superheated. This is in contrast with results from a previous study in which surface oxides were stable and contained numerous sites of nucleation. The number of nucleation events depends upon the surface state of the specimen as determined by the atmosphere and is consistent with theoretical expectations based upon the thermodynamic stability of surface oxide films. Oxide-free specimens are characterized by shiny surfaces, with no observable features under the scanning electron microscope at 5000X.

Ethridge, E. C.↗

Angular particle impingement studies of thermoplastic materials at normal incidence

Scanning electron microscope studies were conducted to characterize the erosion resistance of polymethyl methacrylate (PMMA), polycarbonate (PC), polytetrafluorethylene (PTFE), and ultra-high-molecular-weight polyethylene (UHMWPE). Erosion was caused by a jet of angular microparticles of crushed glass at normal incidence. Material built up above the original surface on all of the materials. As erosion progressed, this buildup disappeared. UHMWPE was the most resistant material and PMMA the least. The most favorable properties for high erosion resistance were high values of ultimate elongation, maximum service temperature, and strain energy and a low value of the modulus of elasticity. Erosion-rate-versus-time curves of PC and PTFE exhibited incubation, acceleration, and steady-state periods. PMMA also exhibited a deceleration period, and an incubation period with deposition was observed for UHMWPE.

Rao, P. V.↗

Evidence for successive episodes of condensation at high temperature in a part of the solar nebula

A polished thin section of a Ca-Al-rich inclusion CAI 3643 from the Allende meteorite has been studied by means of light and scanning electron microscopes, and electron and proton microprobes. The appearance and the mineral composition of the inclusion's three concentric layers: core, mantle, and crust are described. Despite differences in texture and composition, the three layers display a continuity in their modal mineralogical compositions, their extreme Al2O3 enrichments (53-69 percent, compared to 25-45 percent in other CAIs), and their trace element complementarity. This implies that all the layers of CAI 3643 have formed from the same cooling gaseous reservoir within a limited interval of time and space, consistent with an origin in a local transient heating event in the CV chondrite formation region of the nebula.

Wark, D. A.↗

Analytical/experimental correlations of failure modes in composites

During the past decade, significant progress has been made in the development and refinement of finite element micromechanics analyses of unidirectional composite materials. The current status is summarized here, and example results are presented. These are correlated with available experimental data, and with scanning electron microscope observations.

Adams, D. F.↗

Progressive fracture of fiber composites

Refined models and procedures are described for determining progressive composite fracture in graphite/epoxy angleplied laminates. Unique Lewis Research Center capabilities are utilized including the Real-Time Ultrasonic C-San (RUSCAN) experimental facility and the Composite Durability Structural Analysis (CODSTRAN) computer code. CODSTRAN is used to predict the fracture progression based on composite mechanics, finite element stress analysis, and fracture criteria modules. The RUSCAN facility, CODSTRAN computer code, and scanning electron microscope are used to determine durability and identify failure mechanisms in graphite/epoxy coomposites. Results indicate that RUSCAN/CODSTRAN is an effective method of Studying progressive fracture of composites.

Irvine, T. B.↗

Shock-induced CO2 loss from CaCO3 - Implications for early planetary atmospheres

Recovered samples from shock recovery experiments on single crystal calcite were subjected to thermogravimetric analysis to determine the amount of post-shock CO2, the decarbonization interval and the activation energy, for the removal of remaining CO2 in shock-loaded calcite. Comparison of post-shock CO2 with that initially present determines shock-induced CO2 loss as a function of shock pressure. Incipient to complete CO2 loss occurs over a pressure range of approximately 10 to approximately 70 GPa. Optical and scanning electron microscopy reveal structural changes which are related to the shock-loading. The occurrence of dark, diffuse areas, which can be resolved as highly vesticular areas as observed with a scanning electron microscope are interpreted as representing quenched partial melts, into which shock-released CO2 was injected. The experimental results are used to constrain models of shock-produced, primary CO2 atmospheres on the accreting terrestrial planets.

Lange, M. A.↗

Separating Peaks in X-Ray Spectra

Deconvolution algorithm assists in analysis of x-ray spectra from scanning electron microscopes, electron microprobe analyzers, x-ray fluorescence spectrometers, and like. New algorithm automatically deconvolves x-ray spectrum, identifies locations of spectral peaks, and selects chemical elements most likely producing peaks. Technique based on similarities between zero- and second-order terms of Taylor-series expansions of Gaussian distribution and of damped sinusoid. Principal advantage of algorithm: no requirement to adjust weighting factors or other parameters when analyzing general x-ray spectra.

Nicolas, David↗

An in-situ study in SEM of delamination in several graphite/epoxy composite material systems

A three point bend fixture compatible with the current loading stage for the Scanning Electron Microscope was designed and fabricated. End-notched flexure tests were run on several materials. Work to date was on AS4/3502, T6T145/F155, and T6T145/F185. Fracture toughness was measured. Fracture of neat resin specimens was begun. The decrease in delaminatin fracture toughness, compared to neat resin toughness, due to rigid fiber filler and interlaminar failure is addressed. An experimental program was designed to try to determine the proper interpretatin for apparent microcracking in neat resin specimens.

Bradley, W. L.↗

Analysis of micrometeorite material captured by the solar max satellite

A Solar Maximum satellite was retrieved and repaired after being subjected for four years and 55 days to impacts by micrometeorites and Earth-orbiting space debris. The chemical variety and physical condition of particles associated with two particular impact structures in the insulation blanket of the main electronics box are studied. A scanning electron microscope equipped with an energy dispersive X ray analyzer was used to determine morphology and chemistry of impacted areas and associated particles. Some details are discussed.

Schramm, L. S.↗

SSM atomic oxygen reactions on Kapton and silverized Teflon

Surface morphology studies using scanning electron microscopy on Kapton and Inconel silver coated Teflon material samples retrieved from the Solar Maximum Mission spacecraft revealed significant changes attributed to orbital atomic oxygen induced reactions. The Kapton recession observed on the aluminized Kapton material samples appeared equivalent in nature with that observed on previous Space Shuttle LEO missions. SSM Teflon taped material samples, coated on the back side with films of Inconel protected silver were observed degraded on both sides. Visibly severe reactions on the back side produced total blackening, generally restricted to areas of tape with a narrow direct view-factor of the external orbital environment. High magnification scanning electron microscope views provided evidence of near total silver reaction, flaking, and subsequent erosion of the underlying Teflon itself. Only three of the extensive S.E.M. photographs illustrating the basic reactions observed are included pending further detailed investigations.

Roger Linton↗

Performance of textured carbon on copper electrode multistage depressed collectors with medium-power traveling wave tubes

Performance of multistage depressed collectors (MDCs) using textured carbon on copper substrate electrode surfaces was evaluated in conjunction with medium-power traveling wave tubes (TWTs). The MDC and TWT overall efficiencies for these electrodes were measured and compared with those obtained with the same TWT and a copper electrode MDC of identical design. Long-term stability of the carbon-coated copper electrode surfaces was investigated by periodic evaluation of TWT-MDC performance over an extended period of continuous wave (CW) operation. Application of textured carbon coating on copper MDC electrode surfaces produced a 13% improvement in both MDC and TWT overall efficiencies for the TWT-MDC tests. During 1600 hr of CW operation with a medium power TWT, no significant changes in MDC performance were noted. This indicated good stability of the textured carbon electrode surfaces. This stability was confirmed by scanning electron microscope examinations of the electrode surfaces before assembly of the MDC and after completion of the test program.

Ramins, Peter↗

Aeolian abrasion on Venus: Preliminary results from the Venus simulator

The role of atmospheric pressure on aeolian abrasion was examined in the Venus Simulator with a constant temperature of 737 K. Both the rock target and the impactor were fine-grained basalt. The impactor was a 3 mm diameter angular particle chosen to represent a size of material that is entrainable by the dense Venusian atmosphere and potentially abrasive by virtue of its mass. It was projected at the target 10 to the 5 power times at a velocity of 0.7 m/s. The impactor showed a weight loss of approximately 1.2 x 10 to the -9 power gm per impact with the attrition occurring only at the edges. Results from scanning electron microscope analysis, profilometry, and weight measurement are summarized. It is concluded that particles can incur abrasion at Venusian temperatures even with low impact velocities expected for Venus.

Marshall, J. R.↗

Pulsed source of energetic atomic oxygen

A pulsed high flux source of nearly monoenergetic atomic oxygen was designed, built, and successfully demonstrated. Molecular oxygen at several atmospheres pressure is introduced into an evacuated supersonic expansion nozzle through a pulsed molecular beam valve. An 18 J pulsed CO2 TEA laser is focused to intensities greater than 10(9) W/sq cm in the nozzle throat to generate a laser-induced breakdown. The resulting plasma is heated in excess of 20,000 K by a laser supported detonation wave, and then rapidly expands and cools. Nozzle geometry confines the expansion to provide rapid electron-ion recombination into atomic oxygen. Average O atom beam velocities from 5 to 13 km/s were measured at estimated fluxes to 10(18) atoms per pulse. Preliminary materials testing has produced the same surface oxygen enrichment in polyethylene samples as obtained on the STS-8 mission. Scanning electron microscope examinations of irradiated polymer surfaces reveal an erosion morphology similar to that obtained in low Earth orbit, with an estimated mass removal rate of approx. 10(-24) cu cm/atom. The characteristics of the O atom source and the results of some preliminary materials testing studies are reviewed.

Caledonia, George E.↗