Neutrino-less Double Beta Decay of {sup 48}Ca-CANDLES

Neutrino-less double beta decay (0{nu}{beta}{beta}) is currently known to be an only experiment to verify whether lepton number is conserved or not. The lepton number non-conservation is the key to create matter dominated universe with CP violation. The so-called leptogenesys scenario presents a way to create the matter dominated universe by these violations. If neutrinos have Majorana mass, transition from a particle to an anti-particle is possible and the left-handed and right-handed neutrinos could have different masses. It is highly likely that the neutrinos are Majorana particles. We have been studying double beta decay of {sup 48}Ca. Our first stage experiment using the ELEGANT VI detector system gave the best lower limit of the half life of 0{nu}{beta}{beta} of {sup 48}Ca. We have been working on CANDLES detector system to sense much longer lifetime region. We have developed techniques to reduce backgrounds. The CADLES detector system was installed at Kamioka underground laboratory. Here I describe a schematic view of the system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of low energy neutrino cross sections with the PEANUT experiment

The PEANUT experiment was designed to study neutrino interactions in the few GeV range using the NuMi beam at Fermilab. The detector uses a hybrid technique, being made of nuclear emulsions and scintillator trackers. Emulsion films act as a tracking device and they are interleaved with lead plates used as neutrino target. The detector is designed to reconstruct the topology of neutrino interactions at the single particle level. We present here the full reconstruction and analysis of a sample of 147 neutrino interactions occurred in the PEANUT detector and the measurement of the quasi-elastic, resonance and deep-inelastic contributions to the total charged current cross-section. This technique could be applied for the beam monitoring for future neutrino facilities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear Physics with MINERvA

MINERvA is a precision neutrino experiment designed to improve our understanding of the neutrino-nucleus interaction. The experiment uses a fully active scintillation detector to allow full event reconstruction and includes nuclear targets helium, water, carbon, iron and lead. Here we describe the first steps in measuring lead to iron to carbon cross section ratios.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the {sup 8}Li half-life

We report a new measurement of the {sup 8}Li half-life using a plastic scintillator and an ultrafast waveform digitizing module. The result, T{sub 1/2}=(838.40{+-}0.36) ms, improves by a factor of 2.5 the most precise result obtained so far and is furthermore deduced with negligible corrections due to dead time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lithium glass scintillator neutron detector as an improved alternative to the standard 3 he proportional counter

Lithium glass scintillator made from 6Li-enriched substrate is a well known for its neutron detection capability. In spite of neutron interaction, cross section of 6Li happens to be lower than that of 3He. However, the neutron detection efficiency could be higher due to higher volume content of 6Li nuclear in the solid scintillator vs. gas filled proportional counter. At the same time, as lithium glass is sensitive to gamma and charge particle radiation, non-neutron radiation discrimination is required. Our detector is composed of two equal-size cylindrical Li(Ce) glass scintillators. The first one is high-sensitive to thermal neutrons GS-20 (6Li doped), the second one is GS-30 (7Li doped) type Scint-Gobain made lithium glass scintillator. Each of scintillators is coupled with R7400U Hamamatsu subminiature photomultiplier tube, and all assembly is fitted into NP100H 3He tube size. 6Li absorbs thermal neutrons releasing alpha particles and triton with 4.8 MeV total energy deposit inside the scintillator (equivalent to about ~1.3 MeV gamma energy depositions). Because 7Li isotope does not absorb thermal neutrons, and the physical properties of the two scintillators are virtually identical, the difference between these two scintillators could be used to provide neutron dose rate information. Results of study of neutron detector assembled of two Li(Ce) scintillators and NP100H moderator are presented

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-J-07: Evaluating the Adequacy of Biopsy Specimens for Genetic Signature Assessment by Measuring the Metabolic Activity in Specimens Obtained Under 18F-FDG PET/CT Guidance

Purpose: Genetic profiling of biopsied tissue is the basis for personalized cancer therapy. However biopsied materials may not contain sufficient amounts of DNA needed for analysis. We propose a method to determine the adequacy of specimens for performing genetic profiling by quantifying metabolic activity. Methods: We measured the response of two radiation detectors to the activity contained in the minimum amount of tumor cells needed for genetic profiling in biopsy specimens obtained under 2-deoxy-2-({sup 18}F)fluoro-D-glucose ({sup 18}F-FDG) PET/CT guidance. The expected tumor cell concentration in biopsy specimens was evaluated from the amount of DNA needed (∼100 µg) and the number of pathology sections typically used for the analysis. The average {sup 18}F-FDG uptake per cell was measured by incubating KPC-4662 pancreatic tumor cells and HT-29 colorectal adenocarcinoma tumor cells in {sup 18}F-FDG containing solution (activity concentrations between 0.0122 and 1.51 MBq/mL and glucose concentrations of 3.1 and 1 g/L) for 1 to 1.75 hours and then measuring the activity of a known number of cells. Measurements of surrogate specimens obtained using 18G needle biopsies of gels containing these cells in expected concentrations (∼10{sup 4} µL{sup −1}) were performed using an autoradiography CCD based device (up to 20 min exposure) and a scintillation well counter (∼1 min measurements) about 3 and 5 hours after the end of incubation respectively. Results: At start of autoradiography there were between 0.16 and 1.5 {sup 18}F-FDG molecules/cell and between 1.14 and 5.43×10{sup 7} {sup 18}F-FDG molecules/mL. For the scintillation well counter, sample to minimum-detectable-count rate ratios were greater than 7 and the counting error was less than 25% for ≤80 s measurement times. Images of the samples were identifiable on the autoradiograph for ∼10 min and longer exposure times. Conclusion: Scintillation well counter measurements and CCD based autoradiography have adequate sensitivity to detect the tumor burden needed for genetic profiling in 18G core needle biopsies. Supported in part through the NIH/NCI Cancer Center Support Grant P30 CA008748 and by a sponsored research agreement with Biospace Lab S.A.

60 APPLIED LIFE SCIENCES↗

For the detection of subkiloelectron-volt X-rays

A large-area, imaging gas scintillation proportional counter (IGSPC) has been constructed for use in X-ray astronomy. The IGSPC consists of a gas scintillation proportional counter (GSPC) with a 1-micron polypropylene window coupled to a multiwire proportional counter (MWPC) via a calcium fluoride window. The MWPC, filled with a mixture of argon, methane, and tetrakis (dimethylamino) ethylene, detects the UV photons emitted by the xenon gas in the GSPC. Over a sensitive area of 21 sq cm, the instrument has a measured energy resolution of 17.5% (FWHM) and 1.9 mm (FWHM) spatial resolution at 1.5 keV.

Hailey, C. J.↗

Particle Dark Matter in the galactic halo: results from DAMA/LIBRA

The DAMA/LIBRA experiment at the Gran Sasso National Laboratory of the I.N.F.N. has confirmed with higher sensitivity the model independent evidence for Dark Matter (DM) particles in the galactic halo obtained by the former DAMA/NaI experiment by investigating the DM annual modulation signature. Considering the data collected by DAMA/LIBRA together with the data collected by the former DAMA/NaI (cumulative exposure of 0.82 tonxyr) a confidence level of 8.2 sigma has been achieved. The experiment is in data taking; a first upgrading of the set-up has been carried out in Spetember 2008 and a second one--aiming to decrease the experimental energy threshold--is foreseen in September 2010.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A High Resolution Phoswich Detector: LaBr{sub 3}(Ce) Coupled With LaCl{sub 3}(Ce)

An innovative solution for the forward end-cap CALIFA calorimeter of R{sup 3}B is under investigation consisting of two scintillation crystals, LaBr{sub 3} and LaCl{sub 3}, stacked together in a phoswich configuration with one readout only. This dispositive should be capable of a good determination of the energy of protons and gamma radiation. This composite detector allows to deduce the initial energy of charged particles by DELTAE1+DELTAE2 identification. For gammas, the simulations show that there is a high probability that the first interaction occurs inside the scintillator at few centimeters, with a second layer, the rest of the energy is absorbed, or it can be used as veto event in case of no deposition in the first layer. One such a detector has been tested at the Centro de MicroAnalisis de Materiales (CMAM) in Madrid. Good resolution and time signal separation have been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flow Rate Measurement Using {sup 99m}Tc Radiotracer Method in a Pipe Installation

Flow rate is a significant parameter for managing processes in chemical processing plants and water processing facility. Accurate measurement of the flow rate allows engineers to monitor the delivery of process material, which in turn impacts a plant's capacity to produce their products. One of the available methods for determining the flow rate of a process material is by introducing a radiotracer to the system that mimics the material's flow pattern. In this study, a low activity Technetium-99m radioisotope was injected into a water piping setup and the 2'' x 2'' NaI (Tl) detectors were calibrated to detect spectrum peaks at specific points of the pipe installation. Using pulse velocity method, water flow rate was determined to be 11.3 litres per minute. For the sampling method, at different pump capacity, the flow rate was 15.0 litres per minute.

07 ISOTOPE AND RADIATION SOURCES↗

Analysis Of Residence Time Distribution Of Fluid Flow By Axial Dispersion Model

Radioactive tracer {sup 82}Br in the form of KBr-82 with activity {+-} 1 mCi has been injected into steel pipeline to qualify the extent dispersion of water flowing inside it. Internal diameter of the pipe is 3 in. The water source was originated from water tank through which the water flow gravitically into the pipeline. Two collimated sodium iodide detectors were used in this experiment each of which was placed on the top of the pipeline at the distance of 8 and 11 m from injection point respectively. Residence time distribution (RTD) curves obtained from injection of tracer are elaborated numerically to find information of the fluid flow properties. The transit time of tracer calculated from the mean residence time (MRT) of each RTD curves is 14.9 s, therefore the flow velocity of the water is 0.2 m/s. The dispersion number, D/uL, for each RTD curve estimated by using axial dispersion model are 0.055 and 0.06 respectively. These calculations are performed after fitting the simulated axial dispersion model on the experiment curves. These results indicated that the extent of dispersion of water flowing in the pipeline is in the category of intermediate.

07 ISOTOPE AND RADIATION SOURCES↗

Study of GSO scintillator for the LHCf upgrade

The GSO scintillator has a very excellent radiation resistance, fast decay time and large amounts of light yield. Because of these features, GSO will be used to upgrade the current LHCf detector. We examined the features of GSO by using heavy ion beam at Heavy Ion Medical Accelerator in Chiba (HIMAC) Japan. The linearity of PMT R7400 for the large light yield of GSO with a {sup 132}Xe beam and the radiation hardness with a {sup 12}C beam were measured. As a result, GSO scintillator showed a good linearity up to the signal corresponding to 6 TeV EM-shower maximum in the LHCf detector, and a good radiation hardness up to 7x10{sup 5} Gy. For the LHCf Arm1 detector, small scaled GSO crystals (GSO bars), have been fabricated for the position determination detector. 5 GSO bars have been manufactured and its performance have been evaluated using {sup 12}C beam. Its light yield and position dependency have been evaluated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Near Detector(s) to predict the Far Detector Events in NOvA Experiment

The NOvA experiment is designed to search for a non-vanishing mixing angle {theta}{sub 13} with unprecedented sensitivity and has the potential to resolve the neutrino mass hierarchy and constrain CP-violation phase. NO{theta}A will use two functionally identical detectors at near and far locations to eliminate sensitivity to modeling of neutrino flux and cross-sections. The near detector will measure neutrino rate to constrain backgrounds expected in the far detector which will search for appearance of electron neutrinos and/or anti-neutrinos using Fermilab NuMI neutrino beam. This report describes initial thoughts on how the available beams and detectors may be used to reach the NOvA goals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The performance of the MICE muon beam line

The Muon Ionization Cooling Experiment is one lattice cell of a cooling channel suitable for conditioning the muon beam at the front end of a Neutrino Factory or Muon Collider. The beam line designed to transport muons into MICE has been installed, and data was collected in 2010. In this paper the method of reconstructing longitudinal momentum and transverse trace space using two timing detectors is discussed, and a preliminary simulation of the performance of a measured beam in the cooling channel is presented.

43 PARTICLE ACCELERATORS↗

Radiation Shielding Properties of Some Marbles in Turkey

Especially after development of technology, radiation started to be used in a large fields such as medicine, industry and energy. Using radiation in those fields bring hazardous effect of radiation into humancell. Thus radiation protection becomes important in physics. Although there are three ways for radiation protection, shielding of the radiation is the most commonly used method. Natural Stones such as marble is used as construction material especially in critical building and thus its radiation shielding capability should be determined.In this study, gamma ray shielding properties of some different types of marble mined in Turkey, have been measured using a NaI(Tl) scintillator detector. The measured results were also compared with the theoretical calculations XCOM.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Concentrations of {sup 40}K, {sup 226}Ra and {sup 232}Th in Soil Sample in Osmaniye (Turkey)

The {sup 40}K, {sup 226}Ra and {sup 232}Th concentration is due to the magmatic structure of the earth and it can be varied from place to place. Osmaniye is located in the Eastern side of Mediteranean Region. It holds the climatic characteristics of the same region and arises with Middle Taurus Mountains from west to North and with Amonos Mounations in East and West-east parts and is situated between 35 deg. .52'-36 deg. .42' east longitudes and 36 deg. .57'-37 deg. .45' north latitudes. In this study, the natural radioactivity concentrations {sup 40}K, {sup 226}Ra and {sup 232}Th in some soil samples collected in Osmaniye have been investigated. The measurements have been performed using 3x3{sup ''} NaI(Tl) detector system.

54 ENVIRONMENTAL SCIENCES↗

Spectrometer of high energy gamma quantums

A detailed description of the apparatus GG-2M is given. The spectrometer contains a Cerenkov and scintillation (including anticoincidence) counter. The energies of the gamma quantums are measured by a shower calorimeter, in which scintillation counters are used in the capacity of detectors. Results are given for tuning the device on mu-mesons of cosmic rays. The data of physical tuning allow more reliable interpretation of the results of measurements which are received on the satellites.

Blokhintsev, I. D.↗

Digital Autoradiography as a novel complementary technique for the investigation of radioactive contamination in nuclear facilities under dismantlement

The detection (location and quantification) of nuclear facilities to be dismantled possible contamination with low-range particles emitters ({sup 3}H, other low-energy β emitters, a emitters) remains a tedious and expensive task. Indeed, usual remote counters show a too low sensitivity to these non-penetrating radiations, while conventional wipe tests are irrelevant for fixed radioactivity evaluation. The only method to accurately measure activity levels consists in sampling and running advanced laboratory analyses (spectroscopy, liquid scintillation counting, pyrolysis...). Such measurements generally induce sample preparation, waste production (destructive analyses, solvents), nuclear material transportation, long durations, and significant labor mobilization. Therefore, the search for the limitation of their number and cost easily conflicts with the necessity to perform a dense screening for sampling (to maximize the representativeness of the samples), in installations of thousands of square meters (floors, wells, ceilings), plus furniture, pipes, and other wastes. To overcome this contradiction, Digital Autoradiography (D. A.) was re-routed from bio molecular research to radiological mapping of nuclear installations under dismantling and to waste and sample analysis. After in-situ exposure to the possibly-contaminated areas to investigate, commercial reusable radiosensitive phosphor screens (of a few 100 cm{sup 2}) were scanned in the proper laboratory device and sharp quantitative images of the radioactivity could be obtained. The implementation of geostatistical tools in the data processing software enabled the exhaustive characterization of concrete floors at a rate of 2 weeks / 100 m{sup 2}, at lowest costs. Various samples such as drilled cores, or tank and wood pieces, were also successfully evaluated with this method, for decisive results. Thanks to the accurate location of potential contamination spots, this approach ensures relevant and representative sampling for further laboratory analyses and should be inserted in the range of common tools used in dismantling. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗