Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Relays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

ORNL’s Continuing Efforts in Evaluating and Validating TSLs [Slides]

This presentation finds that INS measurements are not as variable based on sample composition, because phonon spectra is a properly of the bulk material. Additionally, INS and transmission measurements are and should be the most significant part of TSL validation, as they are the fundamental quantities used by Monte Carlo neutronics codes. This presentation reasons that relaying solely on theoretical atomistic calculations for TSL evaluation is not enough, they are highly dependent on inter-atomic potentials (which are not the most accurate depending on the quantity trying to be reproduced) and evaluators knowledge and understanding of the material being studied. Finally on Critical benchmarks, while extremely useful for validation of nuclear data at all energies, critical benchmarks are not the best tool to provide a definitive answer on conflicting TSLs. The presentation concludes that INS and transmission measurements need to be the basis of validation of TSLs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advancements in Validation of TSLs through Inelastic Neutron Scattering and Transmission Measurements [Slides]

This presentation finds that INS measurements are not as variable based on sample composition, because phonon spectra is a properly of the bulk material. Additionally, INS and transmission measurements are and should be the most significant part of TSL validation, as they are the fundamental quantities used by Monte Carlo neutronics codes. Relaying solely on theoretical atomistic calculations for TSL evaluation is not enough, they are highly dependent on inter-atomic potentials (which are not the most accurate depending on the quantity trying to be reproduced) and evaluators knowledge and understanding of the material being studied. When dealing with Crit. benchmarks - While extremely useful for validation of nuclear data at all energies, critical benchmarks are not the best tool to provide a definitive answer on conflicting TSLs. Finally, INS and transmission measurements need to be the basis of validation of TSLs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DOE AGM and NAERM FY23 Annual Accomplishments

This document summarizes FY2023 work performed by Lawrence Livermore National Laboratory (LLNL) in support of the DOE Office of Electricity’s (OE) Advanced Grid Modeling (AGM) program, North American Energy Resilience Model (NAERM), and Protective Relaying (PR) program.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spread Spectrum Time Domain Reflectivity for String Monitoring in PV Power Plants (Final Technical Report)

This final report describes the methods and results of applying Spread Spectrum Time Domain Reflectivity (SSTDR) for String Monitoring in PV Power Plants for DE-EE0008169. The project created a new system for both detecting and locating electrical faults in photovoltaic systems. In this work, we address photovoltaic electric faults that are both common and costly. Based on interviews with photovoltaic power plant owners, operators, and maintainers, three types of faults are common and of significant interest: disconnects, ground faults, and arc faults. Disconnects can originate from many sources. They are often due to everyday events, such as lawnmowing (accidentally running over a cable), animals eating through the cables, or degradation that occurs over time due to corrosion or general degradation. Ground faults occur when the cables (for example, due to frayed insolation) connect to the ground, relaying current into the ground. These faults are particularly problematic since the ground faults are often intermittent. That is, ground faults commonly appear during rain storms due to a change in soil conductivity and then disappear when the rain ends. This makes the ground fault difficult to find because while current systems can detect the overall change in voltage and current associated with a ground fault, technicians are necessary to locate the fault. As a result, ground faults may disappear before the technician arrives at the power plant. Hence, locating and fixing ground faults often require multiple trips. We also study arc faults, which can result when nearby conductors create an arc of electrical current through the air. While less common, arc faults can be extremely dangerous. The energetic electrical arc can cause fires and destroy equipment, costing significant damage. Overall all three types of faults cost owners and operators money, either from the destruction of equipment or from technician time. Furthermore, while devices exist for detecting ground faults (ground fault circuit interrupters) and arc faults (arc fault circuit interrupter), these systems only search patterns of electrical current that correspond to each fault. This information cannot be used to locate the fault. In addition, these protection systems experience nuisance trips due to nearby electromagnetic interference, such as from a lawn mower or other motors that produce significant amounts of electromagnetic radiation. Hence, the overall goal of this project is to create an SSTDR tool that provides photovoltaic power plants with more reliable fault detection in addition to the localization of faults. SSTDR works by transmitting electrical signals into the photovoltaic string. Those signals reflect from impedance discontinuities (i.e., disconnects, ground faults, and arc faults). These faults are then detected by measuring the presence of a reflection at the SSTDR and can be located by identifying the location of that reflection in time. In addition, unlike current protection systems, these systems do not experience nuisance trips since their low amplitude, high frequency, and coded signal can by analyzed without interference from the regular operational voltage on the photovoltaic string.

14 SOLAR ENERGY↗

An Urban Climate Archipelago in the Southeastern U.S.

Urban boundary layers (UBLs; Barlow, 2014) are the most populous microclimate in the world but are still a challenge to represent physically due to the lack of frequent observations within most urban centers. We examine a set of inland urban regions of different sizes within the Southeast U.S.: Atlanta, GA; Athens, GA; Augusta, GA; and Columbia, SC. We compare Weather Research and Forecasting (WRF; Skamarock et al., 2019) simulation output of Atlanta to hourly-averaged Aircraft Meteorological Data Relay (AMDAR) temperature profiles within the warm season in the ATL airport. The scaling of the simulated UBL by size of the urban region is assessed by comparing the UBL dynamics of the three smaller cities (Athens, Augusta, and Columbia) to Atlanta.

Wermter, Jospeh↗

Feasibility of Hybrid Electro- and Acousto-Dynamical Systems for Quantum Optical Networks

We present results on an exploratory research program that aims to study the feasibility of novel, sustained, dense, and efficient quantum information generation, storage, retrieval, relay and distribution devices and systems towards future advanced quantum networking architectures. The pathfinder program is anchored on original ideas and device conceptual designs that turn the phononic-sourced challenges into an opportunity towards optimized transduction chains over a broad range of length and energy/temperature scales. The proposal involves conceptual design and feasibility towards integration, commissioning and benchmarking of challenging transduction devices in a scaled quantum network setup.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Data-driven approach to Determining the Fidelity in the Hardware-in-the-loop Systems using Subspace Identification Method

One of the major questions in any Hardware-in-the-loop (HiL) simulation is to understand the fidelity of the HiL simulation itself which is most often indicated qualitatively as either high or low instead of quantifying it. Being cognizant of the level of fidelity forms the crux to assess the validity and credibility of the HiL simulation. In this work, we address this issue by developing a systematic, data-driven approach to assess the fidelity of any HiL simulation, and more specifically, the fidelity of the interface between the simulator and hardware in an HiL simulation. Applying a subspace identification method, a linear system representing the interface is obtained from the time-series data captured between the hardware and simulator in the HiL simulation. Finally, the fidelity is defined based on this linear system properties. The proposed data-driven fidelity quantification framework is illustrated on the IEEE 123 node feeder system running on HYPERSIM and interacting with virtual protection relays.

97 MATHEMATICS AND COMPUTING↗

Employing bacterial microcompartments to create privileged redox pools for biofuel production (Final report: Accomplishments)

Over the award period we made progress on all three objectives. We completed our goal of understanding the impact of cofactor recycling on pathway performance for a propanediol-related pathway (Objective 1) and coupled this data with kinetic metabolic models developed in Objective 3, resulting in several products (4 published research articles, 1 review and 3 other research manuscripts in preparation). We completed half of Objective 2 but found the pathway was incompatible with compartmentalization, which is an important but unexpected result. The details are relayed in the following sections, grouped by objective and task as applicable.

09 BIOMASS FUELS↗

Challenges, Industry Practice, and Research Opportunities for Protection of IBR-Rich Systems

The objective of this technical report is to outline the challenges of protection design for power systems rich in inverter-based resources (IBRs), synthesize current industrial practices, review new approaches from recent literature, and explore future opportunities in protection. IBRs are experiencing widespread adoption across both transmission and distribution systems. When present in significant quantities, IBRs challenge the performance of many traditional protection functions. To address these issues, the industry has developed sophisticated protection schemes that involve advanced relaying techniques in highly engineered pilot projects. However, these schemes are expensive and time-consuming to develop, build, and test. Researchers have proposed a number of new approaches for protection in IBR-rich distribution systems. Despite their potential, these new approaches do not address some major shortcomings of industry approaches stemming from complexity, practical requirements, and reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing and Evaluating a Smart Curtailment Strategy Integrated with a Wind Turbine Manufacturer Platform

The Renewable Energy Wildlife Institute lead a team of scientists, wind developers, and turbine manufacturers in a study to develop and test a “smart curtailment” system intended to help reduce bat collisions with wind turbines. The Vestas Bat Protection System (VBPS) is a newly developed software module within the Supervisory Control and Data Acquisition (SCADA) system of Vestas turbines. The VBPS combines data from commercially available environmental sensors and the turbine’s built-in sensors with the Vestas SCADA system. VBPS is designed to receive environmental data from sensors on the turbine such as temperature, wind speed, wind direction, time of day, and time of year, relays that information to the SCADA system to determine whether to execute turbine curtailments at any given time. The goals of this study were to 1) develop a bat fatality risk model based on bat activity data and environmental data collected in year 1, and to 2) evaluate the VBPS, using the bat fatality risk model to implement curtailment, in comparison to “blanket curtailment” (turbines curtailed when wind speed is below 5.0 meters per second (m/s)) and “control” (normally operating, feathered below 3.0 m/s) turbines in year 2. The field study took place at a wind energy facility in Iowa during the fall bat migration seasons (July – October) in 2021 and 2022. For VBPS to succeed as a viable strategy for the minimization of bat fatalities, it should meet or exceed the performance of blanket curtailment. Specifically, the VBPS should meet the following performance targets to demonstrate whether it an effective, practical risk reduction measure: (1) Turbines operating VBPS should have equal or fewer bat fatalities compared to turbines operating with blanket curtailment, and significantly fewer bat fatalities compared to control turbines; and (2) Turbines operating VBPS should have greater power production compared to turbines operating with blanket curtailment. The study was completed in accordance with the Statement of Project Objectives and within the terms of the Budget Justification. This Final Report describes the progress, challenges, and outcomes of the study.

17 WIND ENERGY↗

High-Throughput Custom Monitoring for the Mu2e TDAQ System

In this project we are studying the application of programmable network hardware to provide a custom monitoring capability for the Mu2e Trigger and Data Acquisition System (TDAQ) system. The goal of the Mu2e experiment is to search for a charged-lepton flavor violating processes where a negative muon converts into an electron in the field of an aluminum nucleus. This experiment is intended to improve by four orders of magnitude the search sensitivity reached so far. We have a working prototype of a system that provides high-throughput, custom monitoring for the Mu2e TDAQ system. The custom Mu2e network packet header format is parsed as it crosses the network switch. Parsing extracts bits that convey information about error states at read-out controllers (ROCs). This information is periodically relayed to the switch controller, which in turn alerts experiment operators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Technical Learning and Integration of Interns in Advanced Protection Lab Space: Enhancements to Testbed and Experiments to Improve Workflows for Producing Datasets

This report presents a successful technical learning integration of student interns in the Advanced Protection Laboratory space, located in the Grid Research Integration and Deployment Center (GRID-C) at the Department of Energy’s (DOE’s) Oak Ridge National Laboratory (ORNL). The Advanced Protection Laboratory was created for the primary goal of supporting DOE’s research projects and technical staff at ORNL. As a secondary goal, the space was used for collaborating with ORNL’s intern programs, providing support to the lab’s mentors and student interns. In 2024, three student interns spent a summer in the Advanced Protection lab space and were involved in the DarkNet Distributed Ledger Technology (DLT) project. The students had a great opportunity to gain hands-on experience with communication and protective relay equipment focused on information technology, data analytics, and cybersecurity. Experiences in the lab space with real equipment and software integration offer education and professional development for students, which is especially important because of a need in the energy industry to recruit highly skilled power and communication engineers.

42 ENGINEERING↗

High throughput battery failure experimental platform

Addressing the need to increase the sample set to understand the causes of lithium battery thermal runaway, we conceived of an experimental platform with capability to increase the number of runaway experiments (currently 3-5 per week), while also collecting detailed electrochemical impedance spectroscopy measurements (EIS). Once expanded, the platform would enable data collection on 10s to 100s of cells that all experience runaway, thereby creating a statistical database necessary to identify early indication of risk. A primary containment unit to house cylindrical cells of variety NMC811 and of size 21700 (21 mm diameter by 70 mm length) was designed with features such as debris containment, preloaded cells in an exchangeable port, nitrogen ventilation, and exhaust containment. We performed the first overcharge abuse experiments of several 21700 cells, handpicked because of different initial EIS, and demonstrated that EIS changes dramatically during early stages of overcharge, but in a different manner than previous pouch cell experiments. The abuse experiments also revealed the discharge pattern and debris field created during runaway, as well as the cell temperature control and overheat, that must be considered in the primary containment apparatus. We designed and built a switching relay system to permit measurement of EIS without an active charging circuit, and created instrument control software for charging, EIS, and cell temperature control. The late-start funding was insufficient to fully construct the primary containment unit, but the foundational design and knowhow is available for any future work.

25 ENERGY STORAGE↗

Hydropower Black Start: A Guidebook for Retrofitting Grid Dependent Hydropower

Not all United States (US) hydropower plants were designed to provide black start, but they are increasingly needed to uphold resilience in the evolving electric grid. This guidance is designed to help understand the minimal retrofits required for grid dependent hydropower (GDH) plants behind the point of interconnection (POI). For distribution connected hydropower plants or those with dedicated cranking paths, such upgrades can be sufficient for the plant to provide black start. For others, more coordination with the transmission system operator will be needed. This guidebook answers a number of questions relevant to retrofitting hydropower plants with black start capabilities. For example, the guidebook answers: • How flexible do the wicket gate controls need to be? • Who needs to do hydro governor model validation, why, and how? • How robust and flexible do the excitation and AVR controls need to be? • What protection settings need to be adjusted? • What relay(s) will need to be bypassed or overridden and at what risk? • What is the electrical energy demand of the station load or auxiliary power systems? • What should the strategy to energize transformer(s) along cranking path to address inrush currents be? • How should the critical load restoration be sequenced? In addition to outlining the specifications that hydropower plants need to meet for each component to be able to perform black start, this guidebook provides a set of case studies for specific upgrades needed at actual plants. Between the case studies of plants that have already performed black start retrofits and the examples of how this guidebook can be applied to scope future retrofits, five key themes have been identified for retrofit needs. 1. Protection needs “black start” mode: hydropower plants that are not designed with black start capabilities will have protections that prevent them from interconnecting to a “dead bus.” These protections will need to be overridden in every retrofit case and a separate black start mode should be established so that operators can safely switch between black start and grid connected modes, minimizing the risk to the plant. 2. Wicket gates need modern controls: digital governors accelerate the parameter tuning process and gate position sensors improve controllability, so plants with mechanical governors should be upgraded. Furthermore, a black start and islanding mode should be established for controls to maximize plant performance. 3. Robust excitation support: the DC system or excitation generator needs to be reliable enough to form and sustain the rotor electromagnetic field. These systems are typically undersized in plants that were not designed for black start, so they will need to be upgraded. 4. Turbine-governor model validation and operator training: validation of a standard hydro governor model is needed to characterize the dynamic response (i.e., inertial and primary frequency response) of the GDH. This is required for control development and old hydropower plants often have outdated or incorrect models. Operator training is also typically required to ensure the hardware retrofits are utilized correctly during the black start process. 5. Transformer and cranking path energization: any upgradation and control adjustment in front of the POI will depend upon the existing interconnection. Coordination with the transmission or distribution operator may be required.

13 HYDRO ENERGY↗

Automated Inspection of Criticality Control Overpacks for Surplus Plutonium Disposition: Qualification Update – 25313

In an effort to reduce the amount of nuclear waste in South Carolina, the Department of Energy (DOE) tasked the Savannah River Site (SRS) with diluting and disposing of the amount of plutonium in the state. This process involves the movement and shipment of over 100,000 criticality control overpacks (CCOs) throughout the project lifespan, lending itself to the use of automation to reduce worker radiation exposure and more efficiently utilize human capital. Due to the large scope, this overarching process was broken down into several different “automation projects” to be developed. The first opportunity pursued was the receipt and inspection of empty CCO drums coming into SRS, identified as Automation Project 1 (AP1), and is the focus of this paper. AP1 was developed to unpack incoming CCOs and inspect them for unwanted foreign objects and any damage to the drum or its contents. This process is accomplished by the combination of an automated guided vehicle (AGV) that delivers CCOs to a robotic arm which uses a suite of custom tools to disassemble a CCO, inspect the inside and outside of the CCO and its inner criticality control container (CCC), reassemble the CCC and CCO, and apply a tamper indicating device (TID) to the inspected drum. In past years, the robotic work cell had been developed in a small-scale testing facility for proof-of-concept. This year, major improvements were made to the robotic work cell to perform the process, including integration into the final facility where CCOs will be inspected. Other technical improvements include the implementation of sensor feedback and safety relays into the control system to allow the state of the work cell to be better tracked, and additional development of the TID application process to complete the robotic inspection. Further enhancements were made to the robotic vision processes and robot pathing, as well as development on a computer vision inspection process to detect inspection criteria anomalies in CCOs. In addition to developmental improvements, the work cell underwent a six-month testing period to ensure the project requirements were met. Results of this testing period demonstrate the work cell’s capability to meet project throughput goals at an acceptable level, successfully document the status of each CCO inspected, and reduce the toll on technical operations’ human power by two thirds. At the time of this paper, the work cell is capable of autonomously handling up to eight CCOs with an AGV, delivering CCOs to and from the robot work cell, and having a robotic arm perform a full receipt and inspection procedure on each CCO. Moving forward, repeatability will be improved so that these CCOs can be run back-to-back seamlessly, as well as improving the system to handle more significant edge cases and failure modes.

Spivey, Nicholas↗

Utility Experience with Inverter Based Resource Impacts on Transmission Protection

High penetration of inverter-based resources (IBR) can adversely affect the transmission protection schemes in the area. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems because the existing system has been designed based on the fault current response of conventional rotating-machine-based generators. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. It includes a broad review of all challenges that system protection has experienced so far with high penetration of IBRs. Key issues have been identified based on a survey of different utility protection engineers. Finally, fault event recordings are shown to demonstrate some actual cases of mis-operations of relays near IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development Fiber Optic Distributed System for Direct Detection of Subsurface Gases Leakages

Carbon, natural gas, and hydrogen gas storage is an emerging solution to safeguard us against pollution, support goals of negative carbon emission, and protect sources of renewable energy. Properly constructed storage wells provide a virtually impervious barrier to any unintended subsurface transmission. The ability to ensure the long-term integrity of such wells is vital to the success of any storage operation and be successful in the public eyes. Therefore, robust monitoring of any gas migration into the subsurface is highly sought. A fiber-optic distributed chemical sensor (DCS) enables monitoring of long-term well integrity along its depth, ensuring the success of any storage operation and bolsters public acceptance of the safety of the reservoir via leak early detection. The same technique can be applied to gas monitoring in pipeline networks and nuclear stockpile monitoring applications. Fiber based Raman spectroscopy enables DCS, as optical fibers can be deployed in virtually any environment and relay spectroscopic information over long distances back to the user. Hollow core fibers (HCF) make excellent DCSs as the air core of the fiber allows gas from the environment to diffuse into the core, which interacts with the laser signal that is carried in the air core. This work builds upon the previous LDRD project, Fiber Optic System for Direct Detection of Carbon Dioxide Leakage in Carbon Storage Wells (21-FS-003), in which the feasibility of Raman spectroscopy detection of Carbon Dioxide (CO2) in HCF detection was demonstrated. We mitigated the risk of this DCS technology by establishing and completing five objectives. The first objective was to model and optically characterize HCF uptake of CO2, establishing the relationship between HCF length, gas diffusion time, detectable gas concentration, and measured Raman intensity. In objective two, we developed a fiber core drilling recipe to enable additional diffusion ports in the fiber core and established a method for maintaining fiber strength and integrity post drilling. Objective three characterized the drilled fibers against the undrilled fibers, establishing the differences in the gas mechanics and optical properties and provided parameters to iterate the drilling process. In objective four, a fusion splicing technique was developed to join the HCF to conventional single-mode fibers, localizing the gas detection point at the drilled HCF hole, emulating a DCS. Lastly, objective five was the testing of the sensor in Edgar Mines at Colorado School of Mines on a CO2 pipeline with a simulated leak, to showcase the ability to detect CO2 leaks. This capstone result showed CO2 leak detection in < 10 minutes, raising the technology readiness level of HCF segments as deployable DCS.

organic↗

Structural Evolution of the Hogback Monocline and Its Tectonic Significance in the San Juan Basin

The San Juan Basin is recognized as a Laramide foreland basin. It is located within the Colorado Plateau, a broad tectonic province characterized by a thick sedimentary sequence that was segmented into smaller sub basins during the Late Cretaceous to Paleogene Laramide orogeny. The Hogback Monocline lies along the northwestern margin of the San Juan Basin and is considered a Laramide-age structure formed in response to compressional stress. In this study, we interpret surface and subsurface datasets to construct a structural geological model and evaluate its tectonic significance. Through seismic data, we identify key fault and fold geometries at depth. The seismic dataset used in this study was reprocessed in depth and constrained with well log velocity data to enhance seismic imaging quality. Additionally, we performed well log correlations to identify formation tops and assess variations in basin infill and thickness geometry. A series of structural cross-sections, constructed using seismic data and a high density of boreholes, are presented to evaluate geometric variations along the structure and its evolution during basin development. Furthermore, kinematic restoration and forward modeling analyses were conducted to validate our structural interpretation. This work suggests that the Hogback Monocline formed through fault-propagation folding and flexural slip affecting the pre-Laramide sedimentary sequence under compressional stresses associated with the Laramide orogeny. This structure is interpreted as a high-angle reverse fault that influenced the geometry of the late basin infill. Additionally, monocline bending along the structure may have been controlled by fault relay systems and, in some cases, influenced by strike-slip faulting.

Reyes, Martin [New Mexico Bureau o fGeology and Mi↗