Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

USTUR Whole Body Case 0262: 33-y Follow-up of PuO2 In A Skin Wound and Associated Axillary Node

This whole body donation case (USTUR Registrant) involved two suspected plutonium oxide (Pu) inhalation intakes, each indicated by a measurable Pu alpha activity in a single urine sample, followed about 1.5 y later by a puncture wound to the thumb while working in a Pu glovebox. The study is concerned with modeling simultaneously the biokinetics of deposition and retention in the respiratory tract and at the wound site; and the biokinetics of Pu subsequently transferred to other body organs, until the donor's death. Urine samples taken after the wound incident had readily measurable Pu alpha activity over the next 14 y, before dropping below the minimum detectable excretion rate (<0.4 mBq per day). The Registrant died about 33 y after the wound intake, at the age of 71, from hepatocellular carcinoma with extensive metastases. At autopsy, all major soft tissue organs were harvested for analysis of their Pu-238, Pu-239+240 and Am-241 content. The amount of Pu-239+240 retained at the wound site was 68 ± 7 Bq (1 SD), measured by low-energy planar Ge spectrometry. A further 56.0 ± 1.2 Bq was retained in an associated axillary lymph node, measured by radiochemistry. Simultaneous mathematical analysis (modelling) of all in vivo urinary excretion data, together with the measured lung, thoracic lymph node, wound, axillary lymph node and systemic tissue contents at death, yielded estimated intake amounts of 757 and 1504 Bq, respectively, for the first and second inhalation incidents, and 204 Bq for the total wound intake. The inhaled Pu material was highly insoluble, with an estimated long-term absorption rate from the lungs of 2 E-5 per day. The Pu material deposited at the wound site was mixed: 14% was rapidly absorbed, 49% was absorbed at the rate of about 6E-5 per day, and the remainder ( 37%) was absorbed extremely slowly (at the rate of about 5E-6 per day). Thus, it was estimated that only 40% of the Pu initially deposited in the wound had been absorbed systemically over the 33-y period until the donor's death. The biokinetic modelling also indicated that, in this individual case, some of the parameter values (rate constants) incorporated in the ICRP Publication 67 Pu model were up to a factor of 2 different from ICRP's recommended values (for reference man).

61 RADIATION PROTECTION AND DOSIMETRY↗

Boiling peak heat flux for steady inhomogeneous heat transfer in superfluid He 4

Superfluid helium-4 (He II) is a widely adopted coolant in scientific and engineering applications owing to its exceptional heat transfer capabilities. However, boiling can spontaneously occur on a heating surface in He II when the heat flux exceeds a threshold value $q^*$, referred to as the peak heat flux. While the parameter $q^*$ holds paramount importance in the design of He II based cooling systems, extensive research has primarily focused on its behavior in steady homogeneous heat transfer from a flat heating surface. For inhomogeneous heat transfer from curved surfaces, $q^*$ exhibits intricate dependance on parameters such as the He II bath temperature $T_b$, the immersion depth $h$, and the curvature radius $R_0$ of the heating surface. A comprehensive understanding on how $q^*$ depends on these parameters remains elusive. In this paper, we report our systematic study on $q^*$ for steady heat transfer from cylindrical and spherical heaters in He II. We compute $q^*$ for a wide range of parameter combinations $(T_b, h, R_0)$ by solving the He II two-fluid equations of motion. The generated data have allowed us to develop a robust correlation that accurately reproduces $q^*$ for all the parameter combinations we explored. Furthermore, our findings, particularly the establishment of the correlation, carry valuable implications for emergent applications that involve steady inhomogeneous heat transfer in He II systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TU-F-12A-05: Sensitivity of Textural Features to 3D Vs. 4D FDG-PET/CT Imaging in NSCLC Patients

Purpose: Neighborhood Gray-level difference matrices (NGLDM) based texture parameters extracted from conventional (3D) 18F-FDG PET scans in patients with NSCLC have been previously shown to associate with response to chemoradiation and poorer patient outcome. However, the change in these parameters when utilizing respiratory-correlated (4D) FDG-PET scans has not yet been characterized for NSCLC. The Objectives: of this study was to assess the extent to which NGLDM-based texture parameters on 4D PET images vary with reference to values derived from 3D scans in NSCLC. Methods: Eight patients with newly diagnosed NSCLC treated with concomitant chemoradiotherapy were included in this study. 4D PET scans were reconstructed with OSEM-IR in 5 respiratory phase-binned images and corresponding CT data of each phase were employed for attenuation correction. NGLDM-based texture features, consisting of coarseness, contrast, busyness, complexity and strength, were evaluated for gross tumor volumes defined on 3D/4D PET scans by radiation oncologists. Variation of the obtained texture parameters over the respiratory cycle were examined with respect to values extracted from 3D scans. Results: Differences between texture parameters derived from 4D scans at different respiratory phases and those extracted from 3D scans ranged from −30% to 13% for coarseness, −12% to 40% for contrast, −5% to 50% for busyness, −7% to 38% for complexity, and −43% to 20% for strength. Furthermore, no evident correlations were observed between respiratory phase and 4D scan texture parameters. Conclusion: Results of the current study showed that NGLDM-based texture parameters varied considerably based on choice of 3D PET and 4D PET reconstruction of NSCLC patient images, indicating that standardized image acquisition and analysis protocols need to be established for clinical studies, especially multicenter clinical trials, intending to validate prognostic values of texture features for NSCLC.

60 APPLIED LIFE SCIENCES↗

SU-F-T-220: Validation of Hounsfield Unit-To-Stopping Power Ratio Calibration Used for Dose Calculation in Proton Radiotherapy

Purpose: To validate the stoichiometric calibration of the Hounsfield Unit (HU) to Stopping Power Ratio (SPR) calibration used to commission a commercial treatment planning system (TPS) for proton radiotherapy dose calculation. Methods and Materials: The water equivalent thickness (WET) of several individual pig tissues (lung, fat, muscle, liver, intestine, rib, femur), mixed tissue samples (muscle/rib, ice/femur, rib/air cavity/muscle), and an intact pig head were measured with a multi-layer ionization chamber (MLIC). A CT scan of each sample was obtained and imported into a commercial TPS. The WET calculated by the TPS for each tissue sample was compared to the measured WET value to determine the accuracy of the HU-to-SPR calibration curve used by the TPS to calculate dose. Results: The WET values calculated by the TPS showed good agreement (< 2.0%) with the measured values for bone and all soft tissues except fat (3.1% difference). For the mixed tissue samples and the intact pig head measurements, the difference in the TPS and measured WET values all agreed to within 3.5%. In addition, SPR values were calculated from the measured WET of each tissue, and compared to SPR values of reference tissues from ICRU 46 used to generate the HU-to-SPR calibration for the TPS. Conclusion: For clinical scenarios where the beam passes through multiple tissue types and its path is dominated by soft tissues, we believe using an uncertainty of 3.5% of the planned beam range is acceptable to account for uncertainties in the TPS WET determination.

60 APPLIED LIFE SCIENCES↗

Medium- and Heavy-Duty Truck Duty Cycles

This dataset provides second-by-second duty cycle data for Class 6 and Class 8 diesel trucks in Texas, including key vehicle metrics, engine-related data, and GPS data (excluding GPS latitude and longitude to ensure confidentiality). The data were collected via tablets installed on the trucks and organized into daily datasets, each associated with a unique vehicle ID and date. There are 12 daily datasets for Class 6 diesel trucks (three unique vehicle IDs) and 43 daily datasets for Class 8 diesel trucks (six unique vehicle IDs). The units associated with each column are included in the name. The engine performance data include columns such as engine speed, engine percent torque, and engine fuel rate. Road grade (%/100) was estimated using the GPS altitude and wheel-based vehicle speed, which is used as an input for FASTSim. Cumulative distance was also calculated using the wheel-based vehicle speed. Additional columns include: - Engine Speed (RPM): Removed inaccurate readings and used to calculate angular velocity (radians/second). - Torque (N·m): Calculated using engine percent torque, nominal friction percent torque, and engine reference torque values (those columns were removed from dataset), then normalized to express as torque (%). - Flywheel Power (%): Calculated using the angular velocity and torque (in kW), then normalized as a percentage of the maximum value. - Engine Fuel Rate (%) and Torque (%): Both metrics were normalized by dividing by their respective maximum values within each dataset to express them as percentages. The datasets were analyzed to assess the energy impact of various driving behaviors, simulate energy efficiency, and recommend optimal routes for diesel trucks using NLR’s tool called RouteE. For driver coaching, factors like speed and acceleration limits were considered, and idle periods were reduced (assuming the engine was off during idling) to adjust each drive cycle. These adjusted drive cycles were then simulated in FASTSim to evaluate their effect on fleet energy consumption and estimate potential energy savings. The original cycles are available for download on this page ![image](CoVaR_Image_for_Data_Page_Kenworth_Truck.jpg)

1Hz↗

TREAT Transient Analysis Benchmarking for the HEU Core

This work was performed to support the feasibility study on the potential conversion of the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory from the use of high enriched uranium (HEU) fuel to the use of low enriched uranium (LEU) fuel. The analyses were performed by the GTRI Reactor Conversion staff at the Argonne National Laboratory (ANL). The objective of this study was to benchmark the transient calculations against temperature-limited transients performed in the final operating HEU TREAT core configuration. The MCNP code was used to evaluate steady-state neutronics behavior, and the point kinetics code TREKIN was used to determine core power and energy during transients. The first part of the benchmarking process was to calculate with MCNP all the neutronic parameters required by TREKIN to simulate the transients: the transient rod-bank worth, the prompt neutron generation lifetime, the temperature reactivity feedback as a function of total core energy, and the core-average temperature and peak temperature as a functions of total core energy. The results of these calculations were compared against measurements or against reported values as documented in the available TREAT reports. The heating of the fuel was simulated as an adiabatic process. The reported values were extracted from ANL reports, intra-laboratory memos and experiment logsheets and in some cases it was not clear if the values were based on measurements, on calculations or a combination of both. Therefore, it was decided to use the term “reported” values when referring to such data. The methods and results from the HEU core transient analyses will be used for the potential LEU core configurations to predict the converted (LEU) core’s performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

International Intercomparison Exercise for Nuclear Accident Dosimetry at the DAF Using GODIVA-IV

The Nuclear Criticality Safety Program operated under the direction of Dr. Jerry McKamy completed the first NNSA Nuclear Accident Dosimetry exercise on May 27, 2016. Participants in the exercise were from Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Sandia National Laboratory (SNL), Savanah River Site (SRS), Pacific Northwest National Laboratory (PNNL), US Navy, the Atomic Weapons Establishment (United Kingdom) under the auspices of JOWOG 30, and the Institute for Radiological Protection and Nuclear Safety (France) by special invitation and NCSP memorandum of understanding. This exercise was the culmination of a series of Integral Experiment Requests (IER) that included the establishment of the Nuclear Criticality Experimental Research Center, (NCERC) the startup of the Godiva Reactor (IER-194), the establishment of a the Nuclear Accident Dosimetry Laboratory (NAD LAB) in Mercury, NV, and the determination of reference dosimetry values for the mixed neutron and photon radiation field of Godiva within NCERC.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Economic Potential of Nuclear-Renewable Hybrid Energy Systems Producing Hydrogen

This report is one in a series of reports that Idaho National Laboratory and the Joint Institute for Strategic Energy Analysis are publishing that address the technical and economic aspects of nuclear-renewable hybrid energy systems (N-R HESs). This report discusses an analysis of the economic potential of a tightly coupled N-R HES that produces electricity and hydrogen. Both low and high temperature electrolysis options are considered in the analysis. Low-temperature electrolysis requires only electricity to convert water to hydrogen. High temperature electrolysis requires less electricity because it uses both electricity and heat to provide the energy necessary to electrolyze water. The study finds that, to be profitable, the examined high-temperature electrosis and low-temperature electrosis N-R HES configurations that produce hydrogen require higher electricity prices, more electricity price volatility, higher natural gas prices, or higher capacity payments than the reference case values of these parameters considered in this analysis.

08 HYDROGEN↗

Can liquid cloud microphysical processes be used for vertically pointing cloud radar calibration?

Cloud radars are unique instruments for observing cloud processes, but uncertainties in radar calibration have frequently limited data quality. Thus far, no single robust method exists for assessing the calibration of past cloud radar data sets. Here, we investigate whether observations of microphysical processes in liquid clouds such as the transition of cloud droplets to drizzle drops can be used to calibrate cloud radars. Specifically, we study the relationships between the radar reflectivity factor and three variables not affected by absolute radar calibration: the skewness of the radar Doppler spectrum ( γ ), the radar mean Doppler velocity ( W ), and the liquid water path (LWP). For each relation, we evaluate the potential for radar calibration. For γ and W , we use box model simulations to determine typical radar reflectivity values for reference points. We apply the new methods to observations at the Atmospheric Radiation Measurement (ARM) sites North Slope of Alaska (NSA) and Oliktok Point (OLI) in 2016 using two 35&thinsp;GHz K a -band ARM Zenith Radars (KAZR). For periods with a sufficient number of liquid cloud observations, we find that liquid cloud processes are robust enough for cloud radar calibration, with the LWP-based method performing best. We estimate that, in 2016, the radar reflectivity at NSA was about 1±1 &thinsp;dB too low but stable. For OLI, we identify serious problems with maintaining an accurate calibration including a sudden decrease of 5 to 7&thinsp;dB in June 2016.

54 ENVIRONMENTAL SCIENCES↗

An integrated approach to monitoring the calibration stability of operational dual-polarization radars

The stability of weather radar calibration is a mandatory aspect for quantitative applications, such as rainfall estimation, short-term weather prediction and initialization of numerical atmospheric and hydrological models. Over the years, calibration monitoring techniques based on external sources have been developed, specifically calibration using the Sun and calibration based on ground clutter returns. In this paper, these two techniques are integrated and complemented with a self-consistency procedure and an intercalibration technique. The aim of the integrated approach is to implement a robust method for online monitoring, able to detect significant changes in the radar calibration. The physical consistency of polarimetric radar observables is exploited using the self-consistency approach, based on the expected correspondence between dual-polarization power and phase measurements in rain. This technique allows a reference absolute value to be provided for the radar calibration, from which eventual deviations may be detected using the other procedures. In particular, the ground clutter calibration is implemented on both polarization channels (horizontal and vertical) for each radar scan, allowing the polarimetric variables to be monitored and hardware failures to promptly be recognized. The Sun calibration allows monitoring the calibration and sensitivity of the radar receiver, in addition to the antenna pointing accuracy. It is applied using observations collected during the standard operational scans but requires long integration times (several days) in order to accumulate a sufficient amount of useful data. Finally, an intercalibration technique is developed and performed to compare colocated measurements collected in rain by two radars in overlapping regions. The integrated approach is performed on the C-band weather radar network in northwestern Italy, during July&ndash;October 2014. The set of methods considered appears suitable to establish an online tool to monitor the stability of the radar calibration with an accuracy of about 2 dB. In conclusion, this is considered adequate to automatically detect any unexpected change in the radar system requiring further data analysis or on-site measurements.

54 ENVIRONMENTAL SCIENCES↗

AFRRI TRIGA Reactor Neutron and Gamma Dose Characterization Preliminary Results

Integral Experiment Request (IER) 484 is part of a series of dose characterization and nuclear accident dosimeter (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). The Armed Forces Radiobilogy Research Institute (AFRRI) 1.1 MW Training, Research, Isotopes, General Atomics (TRIGA) Mark-F reactor is the third facility to undergo a dose study to establish reference dose values. A preliminary measurement was performed earlier this year, where a variety of foils were irradiated and activation gamma rays were measured using a high-purity germanium (HPGe) detector. The data was taken and analyzed to calculate the neutron spectrum in the irradiation facility. This paper will present preliminary results of the neutron dose measured. The characterization of the AFRRI dose field is planned in August.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ON THE HUBBLE SPACE TELESCOPE TRIGONOMETRIC PARALLAX OF THE DWARF NOVA SS CYGNI

SS Cygni is one of the brightest dwarf novae (DNe), and one of the best studied prototypes of the cataclysmic variables. Astrometric observations with the Fine Guidance Sensors (FGSs) on the Hubble Space Telescope (HST), published in 2004, gave an absolute trigonometric parallax of 6.06 {+-} 0.44 mas. However, recent very long baseline interferometry (VLBI), obtained during radio outbursts of SS Cyg, has yielded a significantly larger absolute parallax of 8.80 {+-} 0.12 mas, as well as a large difference in the direction of the proper motion (PM) compared to the HST result. The VLBI distance reduces the implied luminosity of SS Cyg by about a factor of two, giving good agreement with predictions based on accretion-disk theory in order to explain the observed DN outburst behavior. This discrepancy raises the possibility of significant systematic errors in FGS parallaxes and PMs. We have reanalyzed the archival HST/FGS data, including (1) a critical redetermination of the parallaxes of the background astrometric reference stars, (2) updated input values of the reference-star PMs, and (3) correction of the position measurements for color-dependent shifts. Our new analysis yields a PM of SS Cyg that agrees well with the VLBI motion, and an absolute parallax of 8.30 {+-} 0.41 mas, also statistically concordant with the VLBI result at the {approx}1.2 {sigma} level. Our results suggest that HST/FGS parallaxes are free of large systematic errors, when the data are reduced using high-quality input values for the astrometry of the reference stars, and when instrumental signatures are properly removed.

79 ASTRONOMY AND ASTROPHYSICS↗

Systems and methods that generate height map models for efficient three dimensional reconstruction from depth information

Methods of generating a three dimensional representation of an object in a reference plane from a depth map including distances from a reference point to pixels in an image of the object taken from a reference point. Weights are assigned to respective voxels in a three dimensional grid along rays extending from the reference point through the pixels in the image based on the distances in the depth map from the reference point to the respective pixels, and a height map including an array of height values in the reference plane is formed based on the assigned weights. An n-layer height map may be constructed by generating a probabilistic occupancy grid for the voxels and forming an n-dimensional height map comprising an array of layer height values in the reference plane based on the probabilistic occupancy grid.

42 ENGINEERING↗

State of knowledge and challenges of U-Si compounds for use in light water reactor accident tolerant fuel designs

Characterization of the properties of U-Si compounds first required synthesis of high purity material for each of the compositions. The four compounds targeted for investigation in this work were U{sub 3}Si, U{sub 3}Si{sub 2}, USi, and U{sub 3}Si{sub 5}. Specimens of U{sub 3}Si{sub 2}, U{sub 3}Si{sub 5}, and USi with specific geometries for individual testing procedures were prepared using a powder metallurgical method. Thermophysical properties of the U-Si compounds were determined within 100 K of their respective melt point or decomposition temperature. Thermal expansion was determined with a dilatometer, specific heat capacity by the ratio method in a differential scanning calorimeter using a sapphire standard, while thermal diffusivity was determined with a laser flash analyzer. Oxidation performance of the U-Si compounds was determined in a thermogravimetric analyzer (TGA), which measures the weight change of a sample as a function of gas composition and temperature. The results show that each of the U-Si compounds is electronically conductive leading to higher thermal conductivity values than the reference fuel UO{sub 2}. Higher thermal conductivity values will lead to enhanced safety margins within a reactor core and provide better economics over the lifetime of a fuel cycle. However, no improvements have been realized over the reference UO{sub 2} case with regards to oxidation performance in air although more testing is required to substantiate the differences especially in steam and corrosive aqueous LWR environments. Finally, there exists a lack of knowledge in the literature with regards to low burnup irradiation testing on all of the U-Si binary compounds, which would be necessary to simulate their performance in a reactor setting.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Compositional analysis of biomass reference materials: Results from an interlaboratory study

Biomass compositional methods are used to compare different lignocellulosic feedstocks, to measure component balances around unit operations and to determine process yields and therefore the economic viability of biomass-to-biofuel processes. Four biomass reference materials (RMs NIST 8491–8494) were prepared and characterized, via an interlaboratory comparison exercise in the early 1990s to evaluate biomass summative compositional methods, analysts, and laboratories. Having common, uniform, and stable biomass reference materials gives the opportunity to assess compositional data compared to other analysts, to other labs, and to a known compositional value. The expiration date for the original characterization of these RMs was reached and an effort to assess their stability and recharacterize the reference values for the remaining material using more current methods of analysis was initiated. We sent samples of the four biomass RMs to 11 academic, industrial, and government laboratories, familiar with sulfuric acid compositional methods, for recharacterization of the component reference values. In this work, we have used an expanded suite of analytical methods that are more appropriate for herbaceous feedstocks, to recharacterize the RMs’ compositions. We report the median values and the expanded uncertainty values for the four RMs on a dry-mass, whole-biomass basis. The original characterization data has been recalculated using median statistics to facilitate comparisons with this data. We found improved total component closures for three out of the four RMs compared to the original characterization, and the total component closures were near 100 %, which suggests that most components were accurately measured and little double counting occurred. Here, the major components were not statistically different in the recharacterization which suggests that the biomass materials are stable during storage and that additional components, not seen in the original characterization, were quantified here.

09 BIOMASS FUELS↗

SU-F-R-36: Validating Quantitative Radiomic Texture Features for Oncologic PET: A Digital Phantom Study

Purpose: Radiomic texture features derived from the oncologic PET have recently been brought under intense investigation within the context of patient stratification and treatment outcome prediction in a variety of cancer types; however, their validity has not yet been examined. This work is aimed to validate radiomic PET texture metrics through the use of realistic simulations in the ground truth setting. Methods: Simulation of FDG-PET was conducted by applying the Zubal phantom as an attenuation map to the SimSET software package that employs Monte Carlo techniques to model the physical process of emission imaging. A total of 15 irregularly-shaped lesions featuring heterogeneous activity distribution were simulated. For each simulated lesion, 28 texture features in relation to the intensity histograms (GLIH), grey-level co-occurrence matrices (GLCOM), neighborhood difference matrices (GLNDM), and zone size matrices (GLZSM) were evaluated and compared with their respective values extracted from the ground truth activity map. Results: In reference to the values from the ground truth images, texture parameters appearing on the simulated data varied with a range of 0.73–3026.2% for GLIH-based, 0.02–100.1% for GLCOM-based, 1.11–173.8% for GLNDM-based, and 0.35–66.3% for GLZSM-based. For majority of the examined texture metrics (16/28), their values on the simulated data differed significantly from those from the ground truth images (P-value ranges from <0.0001 to 0.04). Features not exhibiting significant difference comprised of GLIH-based standard deviation, GLCO-based energy and entropy, GLND-based coarseness and contrast, and GLZS-based low gray-level zone emphasis, high gray-level zone emphasis, short zone low gray-level emphasis, long zone low gray-level emphasis, long zone high gray-level emphasis, and zone size nonuniformity. Conclusion: The extent to which PET imaging disturbs texture appearance is feature-dependent and could be substantial. It is thus advised that use of PET texture parameters for predictive and prognostic measurements in oncologic setting awaits further systematic and critical evaluation.

60 APPLIED LIFE SCIENCES↗