Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reactive Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A Tariff for Reactive Power

Two kinds of power are required to operate an electric power system: real power, measured in watts, and reactive power, measured in volt-amperes reactive or VARs. Reactive power supply is one of a class of power system reliability services collectively known as ancillary services, and is essential for the reliable operation of the bulk power system. Reactive power flows when current leads or lags behind voltage. Typically, the current in a distribution system lags behind voltage because of inductive loads such as motors. Reactive power flow wastes energy and capacity and causes voltage droop. To correct lagging power flow, leading reactive power (current leading voltage) is supplied to bring the current into phase with voltage. When the current is in phase with voltage, there is a reduction in system losses, an increase in system capacity, and a rise in voltage. Reactive power can be supplied from either static or dynamic VAR sources. Static sources are typically transmission and distribution equipment, such as capacitors at substations, and their cost has historically been included in the revenue requirement of the transmission operator (TO), and recovered through cost-of-service rates. By contrast, dynamic sources are typically generators capable of producing variable levels of reactive power by automatically controlling the generator to regulate voltage. Transmission system devices such as synchronous condensers can also provide dynamic reactive power. A class of solid state devices (called flexible AC transmission system devices or FACTs) can provide dynamic reactive power. One specific device has the unfortunate name of static VAR compensator (SVC), where 'static' refers to the solid state nature of the device (it does not include rotating equipment) and not to the production of static reactive power. Dynamic sources at the distribution level, while more costly would be very useful in helping to regulate local voltage. Local voltage regulation would reduce system losses, increase circuit capacity, increase reliability, and improve efficiency. Reactive power is theoretically available from any inverter-based equipment such as photovoltaic (PV) systems, fuel cells, microturbines, and adjustable-speed drives. However, the installation is usually only economical if reactive power supply is considered during the design and construction phase. In this report, we find that if the inverters of PV systems or the generators of combined heat and power (CHP) systems were designed with capability to supply dynamic reactive power, they could do this quite economically. In fact, on an annualized basis, these inverters and generators may be able to supply dynamic reactive power for about $5 or $6 per kVAR. The savings from the local supply of dynamic reactive power would be in reduced losses, increased capacity, and decreased transmission congestion. The net savings are estimated to be about $7 per kVAR on an annualized basis for a hypothetical circuit. Thus the distribution company could economically purchase a dynamic reactive power service from customers for perhaps $6/kVAR. This practice would provide for better voltage regulation in the distribution system and would provide an alternate revenue source to help amortize the cost of PV and CHP installations. As distribution and transmission systems are operated under rising levels of stress, the value of local dynamic reactive supply is expected to grow. Also, large power inverters, in the range of 500 kW to 1 MW, are expected to decrease in cost as they become mass produced. This report provides one data point which shows that the local supply of dynamic reactive power is marginally profitable at present for a hypothetical circuit. We expect that the trends of growing power flow on the existing system and mass production of inverters for distributed energy devices will make the dynamic supply of reactive power from customers an integral component of economical and reliable system operation in the future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Identification and mapping of riverbed sediment facies in the Columbia River through integration of field observations and numerical simulations

In the Hanford Reach of the Columbia River, a thin layer of recent alluvium overlies the sedimentary formations that comprise the unconfined groundwater aquifer. Experimental and modeling studies have demonstrated that this alluvial layer exerts significant control on the exchange of groundwater and surface water (hydrologic exchange flux), and is associated with elevated levels of biogeochemical activity. This layer is also observed to be strongly heterogeneous, and quantifying the spatial distribution of properties over the range of scales of interest is challenging. Facies are elements of a sediment classification scheme that groups complex geologic materials into a set of discrete classes according to distinguishing features. Facies classifications have been used as a framework for assigning heterogeneous material properties to grid cells of numerical models of flow and reactive transport in subsurface media. The usefulness of such an approach hinges on being able to relate facies to quantitative properties needed for flow and reactive transport modeling, and on being able to map facies over the domain of interest using readily available information. While aquifer facies have been used in various modeling contexts, application of this concept to riverbed sediments is relatively new. Here we describe an approach for categorizing and mapping recent alluvial (riverbed) sediments based on the integration of diverse observations with numerical simulations of river hydrodynamics. The facies have distinct distributions of sediment texture which correspond to variations in hydraulic properties, and therefore provide a useful framework for assigning heterogeneous properties in numerical simulations of hydrologic exchange flows and biogeochemical processes.

Hou, Zhangshuan↗

Dynamic power flow controllers

Dynamic power flow controllers are provided. A dynamic power flow controller may comprise a transformer and a power converter. The power converter is subject to low voltage stresses and not floated at line voltage. In addition, the power converter is rated at a fraction of the total power controlled. A dynamic power flow controller controls both the real and the reactive power flow between two AC sources having the same frequency. A dynamic power flow controller inserts a voltage with controllable magnitude and phase between two AC sources; thereby effecting control of active and reactive power flows between two AC sources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Variably Saturated Flow and Multicomponent Biogeochemical Reactive Transport Modeling of a Uranium Bioremediation Field Experiment

Field experiments at a former uranium mill tailings site have identified the potential for stimulating indigenous bacteria to catalyze the conversion of aqueous uranium in the +6 oxidation state to immobile solid-associated uranium in the +4 oxidation state. This effectively removes uranium from solution resulting in groundwater concentrations below actionable standards. Three-dimensional, coupled variably-saturated flow and biogeochemical reactive transport modeling of a 2008 in situ uranium bioremediation field experiment is used to better understand the interplay of transport rates and biogeochemical reaction rates that determine the location and magnitude of key reaction products. A comprehensive reaction network, developed largely through previous 1-D modeling studies, was used to simulate the impacts on uranium behavior of pulsed acetate amendment, seasonal water table variation, spatially-variable physical (hydraulic conductivity, porosity) and geochemical (reactive surface area) material properties. A principal challenge is the mechanistic representation of biologically-mediated terminal electron acceptor process (TEAP) reactions whose products significantly alter geochemical controls on uranium mobility through increases in pH, alkalinity, exchangeable cations, and highly reactive reduction products. In general, these simulations of the 2008 Big Rusty acetate biostimulation field experiment in Rifle, Colorado confirmed previously identified behaviors including (1) initial dominance by iron reducing bacteria that concomitantly reduce aqueous U(VI), (2) sulfate reducing bacteria that become dominant after {approx}30 days and outcompete iron reducers for the acetate electron donor, (3) continuing iron-reducer activity and U(VI) bioreduction during dominantly sulfate reducing conditions, and (4) lower apparent U(VI) removal from groundwater during dominantly sulfate reducing conditions. New knowledge on simultaneously active metal and sulfate reducers has been incorporated into the modeling. In this case, an initially small population of slow growing sulfate reducers is active from the initiation of biostimulation. Three-dimensional, variably saturated flow modeling was used to address impacts of a falling water table during acetate injection. These impacts included a significant reduction in aquifer saturated thickness and isolation of residual reactants and products, as well as unmitigated uranium, in the newly unsaturated vadose zone. High permeability sandy gravel structures resulted in locally high flow rates in the vicinity of injection wells that increased acetate dilution. In downgradient locations, these structures created preferential flow paths for acetate delivery that enhanced local zones of TEAP reactivity and subsidiary reactions. Conversely, smaller transport rates associated with the lower permeability lithofacies (e.g., fine) and vadose zone were shown to limit acetate access and reaction. Once accessed by acetate, however, these same zones limited subsequent acetate dilution and provided longer residence times that resulted in higher concentrations of TEAP products when terminal electron donors and acceptors were not limiting. Finally, facies-based porosity and reactive surface area variations were shown to affect aqueous uranium concentration distributions; however, the ranges were sufficiently small to preserve general trends. Large computer memory and high computational performance were required to simulate the detailed coupled process models for multiple biogeochemical components in highly resolved heterogeneous materials for the 110-day field experiment and 50 days of post-biostimulation behavior. In this case, a highly-scalable subsurface simulator operating on 128 processor cores for 12 hours was used to simulate each realization. An equivalent simulation without parallel processing would have taken 60 days, assuming sufficient memory was available.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Numerical modeling of coupled fluid flow and thermal and reactive biogeochemical transport in porous and fractured media

Subsurface contamination problems of metals and radionuclides are ubiquitous. Metals and radionuclides may exist in the solute phase or may be bound to soil particles and interstitial portions of the geologic matrix. Accurate tools to reliably predict the migration and transformation of these metals and radionuclides in the subsurface environment enhance the ability of environmental scientists, engineers, and decision makers to analyze their impact and to evaluate the efficacy of alternative remediation techniques prior to incurring expense in the field. A mechanistic-based numerical model could provide such a tool. This paper communicates the development and verification of a mechanistically coupled fluid-flow thermal-reactive biogeochemical-transport model where both fast and slow reactions occur in porous and fractured media. Theoretical bases, numerical implementations, and numerical experiments using the model are described. A definition of the rates of fast/equilibrium reactions is presented to come up with a consistent set of governing equations. Two example problems are presented. The first one is a reactive transport problem which elucidates the non-isothermal effects on heterogeneous reactions. It also demonstrates that the rates of fast/equilibrium reactions are not necessarily greater than that of slow/kinetic reactions in the context of reactive transport. The second example focuses on a complicated but realistic advective dispersive reactive transport problem. This example exemplifies the need for innovative numerical algorithms to solve problems involving stiff geochemical reactions. It also demonstrates that rates of all fast/equilibrium reactions are finite and definite. Furthermore, it is noted that a species-versus-time curve cannot be used to characterize the rate of homogeneous fast/equilibrium reaction in a reactive transport system even if one and only one such reaction is responsible for the production of this species.

54 ENVIRONMENTAL SCIENCES↗

Numerical modeling of coupled fluid flow and thermal and reactive biogeochemical transport in porous and fractured media

Subsurface contamination problems of metals and radionuclides are ubiquitous. Metals and radionuclides may exist in the solute phase or may be bound to soil particles and interstitial portions of the geologic matrix. Accurate tools to reliably predict the migration and transformation of these metals and radionuclides in the subsurface environment enhance the ability of environmental scientists, engineers, and decision makers to analyze their impact and to evaluate the efficacy of alternative remediation techniques prior to incurring expense in the field. A mechanistic-based numerical model could provide such a tool. This paper communicates the development and verification of a mechanistically coupled fluid-flow thermal-reactive biogeochemical-transport model where both fast and slow reactions occur in porous and fractured media. Theoretical bases, numerical implementations, and numerical experiments using the model are described. A definition of the "rates" of fast/equilibrium reactions is presented to come up with a consistent set of governing equations. Two example problems are presented. The first one is a reactive transport problem which elucidates the non-isothermal effects on heterogeneous reactions. It also demonstrates that the rates of fast/equilibrium reactions are not necessarily greater than that of slow/kinetic reactions in the context of reactive transport. The second example focuses on a complicated but realistic advective-dispersive-reactive transport problem. This example exemplifies the need for innovative numerical algorithms to solve problems involving stiff geochemical reactions. It also demonstrates that rates of all fast/equilibrium reactions are finite and definite. Furthermore, it is noted that a species-versus-time curve cannot be used to characterize the rate of homogeneous fast/equilibrium reaction in a reactive transport system even if one and only one such reaction is responsible for the production of this species.

54 ENVIRONMENTAL SCIENCES↗

Nonequilibrium and Reactive High-Speed Flow Simulations with a Fifth-Order WENO Scheme

For high-speed flow over blunt bodies, gas temperature increases dramatically. As a result, gas molecules start dissociating, and vibration and electron energy modes are being excited. Gas becomes thermally nonequilibrium and chemically reactive. Effects of vibration and electron energy excitations, translation-vibration energy relaxation, and chemical reactions among different species need to be considered in numerical simulations. In current paper, a CFD solver based on a fifth-order WENO scheme is developed for the simulation of nonequilibrium and reactive high-speed flows, as part of the ADPDIS3D computer code package. The code is implemented based on a two-temperature model. It is assumed that translation and rotation energy modes are in equilibrium at the translation temperature whereas vibration and electron energy modes are in equilibrium at the vibration temperature. The code is validated and applied to numerical simulations of hypersonic nonequilibrium flows.

Wang, Xiaowen↗

Modeling of fluid injection-induced fault reactivation using coupled fluid flow and mechanical interface model

The present study is aimed at developing a numerical model to reproduce coupled hydro-mechanical processes associated with fault reactivation by fluid injection in low permeability rock, as part of the DECOVALEX-2019 project Task B. We proposed a modeling approach for simulating the processes using the TOUGH-FLAC simulator, and modeled a fault reactivation experiment conducted at Mont Terri Rock Laboratory in Switzerland. The first step of the study involved benchmark calculations considering a simplified fault plane and geometry. Fluid flow along a fault was modeled using elements of aperture-sized thickness on the basis of Darcy's law and the cubic law in TOUGH2, whereas the mechanical behavior of a single fault was represented by zero-thickness interface elements in FLAC3D upon which a slip and/or separation is allowed. A methodology to connect a TOUGH2 volume element to a FLAC3D interface element was developed for handling the hydro-mechanical interactions on the fault during fluid injection. Two different fault models for describing the evolutions of hydraulic aperture by elastic fracture opening and failure-induced aperture increase were considered in the benchmark calculations. In the coupling process, the changes in geometrical features and hydrological properties induced by mechanical deformation were continuously updated. The transient responses of the fault and host rock to stepwise pressurization were examined during the simulation. The hydro-mechanical behavior, including the injection flow rate, pressure distribution around the borehole, stress conditions, and displacements in normal and shear directions were monitored in the surrounding rock and along the fault. The results of benchmark calculations suggest that the developed model reasonably represents the hydro-mechanical behavior of a fault and the surrounding rock. This modeling approach was applied to the fault reactivation experiment of the Mont Terri Rock Laboratory. In this interpretive modeling, a parametric study was conducted to examine the effects of input parameters regarding in situ stress and fault properties on the hydro-mechanical responses of the fault to water injection. Then, an optimal parameter set to reproduce the field experiment results was chosen by trial-and-error. The injection flow rate and pressure response during fault reactivation closely matched those obtained at the site, which indicates the capability of the model to appropriately capture the progressive pathway evolution during fault reactivation tests at the site. Finally, the anchor displacements were overestimated by the model, but a fair agreement was obtained in terms of the order of magnitude and the variation tendency.

58 GEOSCIENCES↗

Performance Assessment of a Generic Nuclear Waste Repository in Shale - 18392

A performance assessment (PA) is an important component of a comprehensive safety analysis for a nuclear waste repository. In a PA, probabilistic simulations of the total repository system are performed, and results are evaluated against performance metrics. Uncertainty and sensitivity analyses help prioritize additional research and model development. The United States Department of Energy (DOE) has been developing a state of the art PA simulation software tool-kit, Geologic Disposal Safety Assessment (GDSA) Framework, that couples increasingly higher fidelity models of subsystem processes into total system PA simulations. Over the past several years, PAs of generic repositories in three geologic media (salt, shale, and crystalline rock) have demonstrated ongoing developments in capability. The current PA of a nuclear waste repository in a generic shale formation showcases GDSA Framework, including capabilities in domain discretization (Cubit), multi-physics simulations (PFLOTRAN), uncertainty and sensitivity analysis (Dakota), and visualization (Paraview). The generic shale reference case considers the disposal of 22,000 metric tons heavy metal of commercial spent nuclear fuel (SNF) in a generic shale formation. PA simulations account for the thermal load and radionuclide inventory of the waste form, components of the engineered barrier system including waste package and buffer, and components of the natural barrier system including the host rock shale and underlying and overlying stratigraphic units. Two repository layouts are considered, one for emplacement of waste packages containing 12 pressurized water reactor (PWR) assemblies, and one for 4-PWR waste package emplacement. Model domains are half-symmetry and contain between 7 and 22 million grid cells. Grid refinement captures the detail of individual waste packages, emplacement drifts, access drifts, and shafts. Simulations are run in a high-performance computing (HPC) environment on 512 or 2048 processes. The governing equations describing coupled heat and fluid flow and reactive transport are solved with PFLOTRAN, an open-source, massively parallel multiphase flow and reactive transport code. Additional simulated processes include waste package degradation; waste form dissolution; radioactive decay and ingrowth in aqueous, solid, and adsorbed phases; and a simple biosphere based on a pumping well. Simulations are run to 106 y; dose and radionuclide concentrations are observed within aquifers at a point approximately 5 km downgradient of the repository. Dakota is used to sample likely ranges of input parameters including waste form and waste package degradation rates and properties of engineered and natural materials to quantify uncertainty in predicted concentrations and sensitivity to input parameters. Given the assumptions of the reference case, results of 12-PWR and 4-PWR simulations are very similar. Dose at the pumping well 5-km downgradient of the repository does not exceed 10-9 Sv/y. I-129 is the largest contributor to dose. The dose due to Cl-36, the next largest contributor, is orders of magnitude smaller. At the pumping well, the concentration of I-129 5-km downgradient does not exceed 10-14 mol/L. Rank correlation coefficients indicate that the maximum concentration of I-129 within the aquifer is sensitive to shale (repository host rock) porosity and aquifer permeability. These results affirm that HPC-capable codes can be used to simulate important multi-physics couplings directly in a total system performance assessment of a geologic repository, and can be used in prioritization of future research and model development. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of PFLOTRAN Transport Capability for Use in the Waste Isolation Pilot Plant Performance Assessment - 20545

Waste Isolation Pilot Plant (WIPP) performance assessment (PA) calculations estimate the probability of radionuclide release from the repository to the land surface and across the land withdrawal boundary for a regulatory period of 10,000 years after facility closure. Simulations of flow and transport in the repository and the surrounding Salado Formation are foundational to the PA. Because proposed additional waste emplacement panels would result in an asymmetric repository layout, the US Department of Energy (DOE) is preparing to transition to use of a three-dimensional (3-D) model domain for simulation of flow and transport instead of the two-dimensional (2-D) flared grid domain currently used. DOE has charged Sandia National Laboratories with developing the capability necessary to simulate processes affecting flow and transport in the WIPP in PFLOTRAN, an open-source massively parallel multi-phase flow and reactive transport code. The new flow and transport capabilities developed in PFLOTRAN incorporate WIPP-specific process models and will replace the 2-D simulators (BRAGFLO and NUTS) that are currently utilized for Salado flow and transport calculations in WIPP PA. The focus of this paper is on the development of a new Nuclear Waste Transport (NWT) mode in PFLOTRAN that has all of the capabilities necessary for Salado transport simulations, including the ability to handle complete dry-out (100% gas saturation) of arbitrary cells in the model domain, radionuclide mass conservation at step changes in porosity associated with borehole intrusion, and the ability to calculate fluxes on a flared grid. The new PFLOTRAN transport capability and a suite of verification tests were designed around a list of functional requirements for WIPP PA calculations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Device-scale CFD study for mass transfer coefficient and effective mass transfer area in packed column

Carbon dioxide (CO 2 ) is a significant contributor of greenhouse gases emissions responsible for global warming. The fossil-fueled power plant is one of the major sources of CO 2 emission worldwide and needs to be mitigated. Post-combustion carbon capture by chemical absorption can be a promising technology to reduce CO 2 emission from power plants. The absorption is carried out via countercurrent flow in the packed columns. Although monoethanolamine (MEA) is a popular solvent, it has also limitations such as high volatility of solvent, corrosivity that leads to product degradation and damage to apparatuses, low CO 2 loading capacity, etc. Therefore, alternate solvents are being explored as prospective materials for carbon capture. A water-lean solvent, CO 2 binding organic liquids (CO2BOL), is currently being developed as a prospective material in carbon capture at the Pacific Northwest National Laboratory. Since the development of the material is at the primitive stage, it needs extensive investigation before industrial deployments. Hydrodynamics and mass transfer phenomena in the packed column using CO 2 BOL is unknown. Computational fluid dynamics (CFD) can be a useful tool to understand these phenomena in the packed column. Before employing the extensive CFD investigations, one needs to carefully validate CFD predictions for accurate flow predictions. This report demonstrates the validation of multiphase flow simulations against the experimental results for both structured and random packed columns. The reactive multiphase flow simulations using volume of fluid method were conducted at a wide range of liquid loads and contacts angles. The effective area is one of the critical factors dictating interphase mass transfer due to chemical reactions. Accordingly, CFD-predicted effective areas were compared with the experimental results of Tsai et al. [1] for Mellapak 250.Y structured packing. Both results matched well at different liquid loads in the presence of fast chemical kinetics using caustic solvents. Further, reactive multiphase flow simulations were also conducted in pall ring random packing to compute effective areas in the presence of fast chemical reactions. The CFD-predicted effective area compared well with correlation developed by Song et al. [2]. With successful validations, the current simulation framework can be further used for prediction of hydrodynamics and mass transfer phenomena using CO 2 BOL solvents in the packed column. Subsequently, it would be helpful in design optimization of a packed column. In addition to validation of the CFD model, this report also explains the mechanism for enhanced liquid side mass transfer for a structured packed column as compared to the wetted wall column.

20 FOSSIL-FUELED POWER PLANTS↗

Characterization of fluidized bed chemical vapor deposition ZrC coatings on PyC/YSZ kernels deposited under differing conditions

In this study, coated fuel particle architectures with ZrC coatings are candidate fuels for advanced power reactors and space nuclear propulsion (SNP) concepts. Owing to its relevance to SNP, the composition, microstructure, and mechanical properties of eight ZrC coatings prepared by fluidized bed chemical vapor deposition were evaluated. Evaluation by SEM and EBSD showed that all grains were columnar. Across the various examined samples, minor axis diameters varied between 0.3 and 1.1 μm, and major axis diameters varied between 0.4 and 2.3 μm. Major and minor diameters increased with thickness particularly at higher deposition temperatures in which the major grain axis (from an ellipse fit to the grain shape) increased by 2.5 μm over the entire coating. Coatings with higher reactive gas flows and Zr/C concentrations closer to 1 were observed to contain nanocrystalline graphite deposits. Reactive gas flow doubling led to increases in coating thickness from around 10–15 μm to around 22–27 μm.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of heat exchanger tubes on hydrodynamics and CO 2 capture of a sorbent-based fluidized bed reactor

In virtual design and scale up of pilot-scale carbon capture systems, the coupled reactive multiphase flow problem must be solved to predict the adsorber’s performance and capture efficiency under various operation conditions. This paper focuses on the detailed computational fluid dynamics (CFD) modeling of a pilot-scale fluidized bed adsorber equipped with vertical cooling tubes. Multiphase Flow with Interphase eXchanges (MFiX), an open-source multiphase flow CFD solver, is used for the simulations with custom code to simulate the chemical reactions and filtered models to capture the effect of the unresolved details in the coarser mesh for simulations with reasonable simulations and manageable computational effort. Previously developed two filtered models for horizontal cylinder drag, heat transfer, and reaction kinetics have been modified to derive the 2D filtered models representing vertical cylinders in the coarse-grid CFD simulations. The effects of the heat exchanger configurations (i.e., horizontal or vertical) on the adsorber’s hydrodynamics and CO2 capture performance are then examined. The simulation result subsequently is compared and contrasted with another predicted by a one-dimensional three-region process model.

bubbling bed↗

DAMAGE DETECTION IN PLATE STRUCTURES USING MODAL POWER FLOW ANALYSIS

The power flow and energy distribution of a vibration mode of a damaged plate is studied experimentally. Variation of the modal reactive power distribution of a damaged plate is experimentally evaluated with a scanning LDV and compared to the theoretical predictions. Large variation of local reactive power flow in or around the damage region of a plate under resonant vibration is found to be related to the change of strain and kinetic energies in the damage region. Feasibility of damage identification based on the detection of this local variation of modal reactive power flow in a structure is studied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗