Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ReEDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Co‑cultivation of the anaerobic fungus Caecomyces churrovis with Methanobacterium bryantii enhances transcription of carbohydrate binding modules, dockerins, and pyruvate formate lyases on specific substrates

Abstract Anaerobic fungi and methanogenic archaea are two classes of microorganisms found in the rumen microbiome that metabolically interact during lignocellulose breakdown. Here, stable synthetic co-cultures of the anaerobic fungus Caecomyces churrovis and the methanogen Methanobacterium bryantii (not native to the rumen) were formed, demonstrating that microbes from different environments can be paired based on metabolic ties. Transcriptional and metabolic changes induced by methanogen co-culture were evaluated in C. churrovis across a variety of substrates to identify mechanisms that impact biomass breakdown and sugar uptake. A high-quality genome of C. churrovis was obtained and annotated, which is the first sequenced genome of a non-rhizoid-forming anaerobic fungus. C. churrovis possess an abundance of CAZymes and carbohydrate binding modules and, in agreement with previous studies of early-diverging fungal lineages, N6-methyldeoxyadenine (6mA) was associated with transcriptionally active genes. Co-culture with the methanogen increased overall transcription of CAZymes, carbohydrate binding modules, and dockerin domains in co-cultures grown on both lignocellulose and cellulose and caused upregulation of genes coding associated enzymatic machinery including carbohydrate binding modules in family 18 and dockerin domains across multiple growth substrates relative to C. churrovis monoculture. Two other fungal strains grown on a reed canary grass substrate in co-culture with the same methanogen also exhibited high log2-fold change values for upregulation of genes encoding carbohydrate binding modules in families 1 and 18. Transcriptional upregulation indicated that co-culture of the C. churrovis strain with a methanogen may enhance pyruvate formate lyase (PFL) function for growth on xylan and fructose and production of bottleneck enzymes in sugar utilization pathways, further supporting the hypothesis that co-culture with a methanogen may enhance certain fungal metabolic functions. Upregulation of CBM18 may play a role in fungal–methanogen physical associations and fungal cell wall development and remodeling.

09 BIOMASS FUELS↗

Utah FORGE: Sanvean Technologies Drilling Data from Well 16B(78)-32

Included here is Sanvean Technologies bit sensor data amalgamated with data from National Oilwell Varco's (NOV) BlackBox tool for Reed Hycalog bits used during drilling of Well 16B(78)-32. The dataset contains information collected at the bit while drilling including rate of penetration (ROP), top drive torque, and bit box temperature. The data was recorded at the bit box and top sub of the motor. RPM was measured by onboard gyro recording continuously in each sensor, and shock levels were also recorded on X, Y and Z axis. This data was merged with EDR in time format and saved in file sets (the zipped files) then output into CSV files. Please note: fields in the CSV files, such as the date field, may need to be formatted to display properly. There is an additional zipped folder in each dataset that is password protected. Sanvean GameChanger Viewer software must be used to view this password protected data. Information on how to use and download this free software is also included here.

15 GEOTHERMAL ENERGY↗

Root responses to warming and hurricane disturbances in a wet tropical forest of Puerto Rico: R code and data

The purpose of this data was to generate a scientific article that describes the responses of tropical roots to a warming experiment and to the effect of two consecutive hurricanes in Puerto Rico (Yaffar et al. in review). This data is from 10 months of minirhizotron images taken every 2 weeks at the experimental warming Tropical Responses to Altered Climate Experiment (TRACE) plots in Puerto Rico before and after Hurricanes Irma and Maria. This project has 3 warmed plots (plot 2,4,6) and 3 control plots (plot 1,3,5) with 2 minirhizotron tubes at each plot. As part of the data, there is also root data taken from cores and in-growth cores. Additionally, there is soil nutrient concentration data, soil microclimate, total leaf area, and canopy openness taken by Reed et al. 2020, and the TRACE census. Data files are in CSV format and the R code included in this package can be used with R 3.4.4 (R Core Team and contributors worldwide).

54 ENVIRONMENTAL SCIENCES↗

AmeriFlux FLUXNET-1F CA-SF2 Saskatchewan - Western Boreal, forest burned in 1989

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site CA-SF2 Saskatchewan - Western Boreal, forest burned in 1989. This is the FLUXNET version of the carbon flux data for the site CA-SF2 Saskatchewan - Western Boreal, forest burned in 1989 produced by applying the standard ONEFlux (1F) software. Site Description - Amiro_et_al_2006, AFM/136:...The 1989 burn site (F89) was northeast of Prince Albert National Park, Saskatchewan, with the humancaused fire covering 13,500 ha. Parts of the area had been logged prior to the fire, and slash residues would have been burned in some locations. Parts of the area were aerially seeded with jack pine seeds in the winter of 1990. The present tree canopy was composed of balsam poplar (Populus balsamifera L.), jack pine, trembling aspen, and birch (Betula papyrifera Marsh.) and prior to the fire, the stand consisted of these same species aswell asblack spruce.Deadsnags of black spruce and jack pinewere still standing, althoughmost had fallen over and formed a leaningmix of dry, dead tree boles. The understory vegetation consisted mostly of black spruce saplings, saplings of the tree overstory species, bearberry, blueberry (Vaccinium myrtilloides Michx.), raspberry (Rubus idaeus L.), rose (Rosa acicularis Lindl.), bunchberry (Cornus canadensis L.), and reed grass (Calamagrostis canadensis (Michx.) Nutt.).

Amiro, Brian↗

AmeriFlux FLUXNET-1F US-WPT Winous Point North Marsh

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-WPT Winous Point North Marsh. This is the FLUXNET version of the carbon flux data for the site US-WPT Winous Point North Marsh produced by applying the standard ONEFlux (1F) software. Site Description - The marsh site has been owned by the Winous Point Shooting Club since 1856 and has been managed by wildlife biologists since 1946. The hydrology of the marsh is relatively isolated by the surrounding dikes and drainages and only receives drainage from nearby croplands through three connecting ditches. Since 2001, the marsh has been managed to maintain year-round inundation with the lowest water levels in September. Within the 0–250 m fetch of the tower, the marsh comprises 42.9% of floating-leaved vegetation, 52.7% of emergent vegetation, and 4.4% of dike and upland during the growing season. Dominant emergent plants include narrow-leaved cattail (Typha angustifolia), rose mallow (Hibiscus moscheutos), and bur reed (Sparganium americanum). Common floating-leaved species are water lily (Nymphaea odorata) and American lotus (Nelumbo lutea) with foliage usually covering the water surface from late May to early October.

Chen, Jiquan↗

Duke Energy Carbon-Free Resource Integration Study: Capacity Expansion Findings and Production Cost Modeling Plan [Slides]

This presentation highlights initial results from the NREL's Low-Carbon Integration study for Duke Energy. Specifically the presentation focuses on preliminary findings from the ReEDS capacity expansion model for the Carolinas. In addition, the presentation also introduces initial plans for the production cost modeling stage of the work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fission to Fusion: An Island Goes Missing

Hollywood actor Reed Hadley walked the decks of the USS Estes with the practiced ease characteristic of his profession. Stopping periodically to relight his pipe, Hadley narrated an AEC film depicting the final hours and minutes leading up to the detonation of Mike, the world’s first thermonuclear bomb. Hadley’s smooth camera presence contrasted sharply with those of the scientists and technicians he interviewed, particularly Alvin Graves, who came across wooden and condescending. Just after Hadley put on his dark goggles to prevent flash blindness, Mike exploded with a force of 10.4 megatons, completely vaporizing the entire ground zero island of Elugelab. The film made one thing clear – Los Alamos scientists could build a thermonuclear bomb, but they could not act.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Retail Rate Projections for Long-Term Electricity System Models

Electricity prices reported in most electricity-system planning studies leave out many price components and do not translate into retail rates, making it difficult to interpret how projected electricity system changes will impact costs to consumers. Full transmission costs are left out of many studies; distribution and administration costs are similarly excluded or highly simplified. Here, we present a detailed bottom-up accounting method for projecting future retail electricity rates in the United States. Making the simplifying assumption that each state is served by an investor-owned utility (IOU), we translate projected generation and transmission capacity and costs from the Regional Energy Deployment System (ReEDS) capacity-expansion model into IOU balance sheet expenditures, accounting for depreciation, taxes, and the breakdown between operating and capitalized (rate-based) expenses. Distribution, administration, and intra-regional transmission costs are projected forward based on empirical trends over the past decade. Modeled bottom-up electricity rates are compared to historical rates from 2010-2019, and the sensitivity of modeled rates to a range of financing and modeling assumptions is explored. Distribution and administration rate components account for roughly 40% (4.4 ¢/kWh) of the projected national-average retail rate over 2020-2050 under central assumptions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Storage Futures Study: Grid Operational Impacts of Widespread Storage Deployment

This report, the fifth in the Storage Futures Study series, uses cost-driven scenarios from the ReEDS model as a starting point to examine the operational impacts of grid-scale storage deployment and relationships between this deployment and the contribution of variable renewable energy. We use commercial production cost modeling software to evaluate hourly operation of five scenarios that reach between 210 gigawatts (GW) and 930 GW of installed storage by 2050. We find that storage plays an important role in these power systems between now and 2050 - by storing the lowest-marginal cost generation (often, overgeneration from solar or wind plants) and generating energy during the highest net load periods of the day and year. Storage helps with the integration of variable renewable energy and by providing an important resource to provide continued reliable power.

25 ENERGY STORAGE↗

An Architectural Survey of the REECo Maintenance Compound, Area 6, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to install a 26.45-mile-long 138-kilovolt (kV) transmission line on the Nevada National Security Site (NNSS) in Nye County, Nevada. This new transmission line will upgrade the electrical transmission system and provide reliable power between Mercury Switching Station in Area 23 and the U1a Facility in Area 1. The proposed upgrade to the power transmission system constitutes an undertaking subject to review under Section 106 of the National Historic Preservation Act (NHPA) (54 United States Code [USC] § 306101) and its implementing regulations, 36 Code of Federal Regulations (CFR) Part 800. A portion of this new transmission line will cross the western perimeter of the Reynolds Electrical and Engineering Company (REECo) Maintenance Compound located in Area 6 of the NNSS. This compound with its trade shops, storage sheds, and yards served as a general construction facility that supported nuclear testing activities on the NNSS from 1967 to 1992. Although three architectural resources in the compound have previously been recorded and evaluated for the National Register of Historic Places (NRHP), other resources within it have not, nor has the compound been recorded and evaluated as a potential district. The State Historic Preservation Officer (SHPO) concurred with NNSA/NFO’s determination that the unevaluated REECo Maintenance Compound will be adversely affected by the proposed undertaking (Reed 2021). The NNSA/NFO, in consultation with the SHPO, then developed the Memorandum of Agreement DE-GM58-22NA25553 between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Installation of a 138-kilovolt Transmission Line from the Mercury Switching Station to the U1a Facility and the Removal of the Historic 138-kilovolt Transmission Line from the Mercury Switching Station to the U1a Facility in Areas 1, 3, 5, 6, and 23 of the Nevada National Security Site, Nye County, hereafter referred to as the MOA. This architectural survey report was prepared in accordance with MOA Stipulation III.B. It describes the origins, history, layout, and functions of the REECo Maintenance Compound during the Cold War and identifies contributing and noncontributing resources. The report defines a district boundary based on archival research and the field survey and concludes with an appendix that presents digital color images of the compound with descriptions and a map key showing image viewpoints and directions. Although none of the architectural resources are recommended individually eligible, the district evaluation concludes the REECo Maintenance Compound is eligible as a historic district for listing in the NRHP under the Secretary of the Interior’s Significance Criteria A and C at the local level. The historic district retains all seven aspects of integrity and conveys its significance under the abovementioned criteria.

138 kV↗

Opportunities for Renewable Energy, Storage, Vehicle Electrification, and Demand Response in Rajasthan's Power Sector

To support the government of Rajasthan and inform state policy makers, regulators, planners, and system operators on power system trends, NREL undertook a long-term capacity expansion planning study. We used NREL's flagship capacity expansion planning tool for the power sector called the Regional Energy Deployment System India (ReEDS-India) to understand the generation and transmission needs of Rajasthan through 2050. NREL's modeling framework includes co-optimized decisions about generation, energy storage, transmission, and reserves investments needed to meet future demand while maintaining reliable electricity supply. Scenario analysis was conducted to assess a range of potential future scenarios, providing insight for planning agencies, utilities, and local stakeholders about key trends and sources of uncertainty.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluating Impacts of the Inflation Reduction Act and Bipartisan Infrastructure Law on the U.S. Power System

The Inflation Reduction Act of 2022 (IRA) and the Infrastructure Investment and Jobs Act of 2021, commonly referred to as the 'Bipartisan Infrastructure Law (BIL),' collectively represent the largest commitment of the U.S. Federal Government to invest in the modernization and decarbonization of the U.S. energy system. The Congressional Budget Office (CBO) estimates that total support for the broad range of climate and clean energy programs, tax credits, and other incentives authorized through the two laws will exceed $430 billion from 2022 through 2031 (CRS 2022; CBO 2021, 2022). While the climate and clean energy provisions are numerous and have the potential to impact all aspects of the U.S. energy system from fuel and electricity production to final consumption in industry, transportation, and buildings, the provisions relevant to the electricity sector - in particular the suite of tax credits for clean generation, storage, and carbon dioxide ( CO 2 ) capture and storage - are expected to be some of the most consequential in terms of emissions reduction and clean energy deployment (Larsen et al. 2022; Jenkins, Mayfield, et al. 2022; Mahajan et al. 2022; Zhao et al. 2022). In this report, we detail the methods and results of a study estimating the potential impacts of key provisions of IRA and BIL on the contiguous U.S. power sector from present day through 2030. The analysis employs an advanced power system planning model, the Regional Energy Deployment System (ReEDS), to evaluate how major provisions from both laws impact investment in and operation of utility-scale generation, storage, and transmission, and, in turn, how those changes impact power system costs, emissions, and climate and health damages. While not exhaustive in capturing every provision, the analysis estimates the possible scale of power-sector impacts that could result from the modeled provisions in IRA and BIL. The study is structured around two scenarios to evaluate the potential impacts of both laws on the power sector: 1) No New Policy: A counter-factual scenario that reflects all Federal and state policies enacted as of September 2022, with exception to IRA and BIL, and assumes load growth consistent with the Energy Information Administration's Annual Energy Outlook 2022 (AEO22) Reference case (EIA 2022a); 2) IRA-BIL: A scenario reflecting all Federal and state policies enacted as of September 2022, including key IRA and BIL provisions, most notably the investment and production tax credits for zero-carbon emitting electricity generation and storage (ITC and PTC), the tax credit for CO 2 capture and storage (45Q), and the tax credit for existing nuclear plants (described further in Section 2.3). To account for the impacts of IRA and BIL on electrification, assumes increased load growth consistent with a scaled version of the Medium Electrification scenario from the Electrification Futures Study (Mai et al. 2018). These scenarios are simulated across seven sets of assumptions with varying projected future electricity market conditions, including technology costs and performance, natural gas prices, and the degree of availability, feasibility, and cost of development of renewable resources, electricity transmission, and CO 2 pipeline, injection, and storage infrastructure. In addition, we simulate two sensitivities on the 'policy' treatment in which we vary key assumptions pertaining to the realized value of the clean electricity ITC and PTC: 1) the cost of monetization of tax credits, and 2) the level of bonus crediting realized by project developers. We demonstrate that IRA and BIL have the collective potential to drive substantial growth in clean electricity by 2030, while reducing costs for consumers, mitigating climate change, and decreasing the human health impacts of power sector emissions. However, we also demonstrate that if expected cost improvements of clean technologies are not realized and/or constraints on deployment driven by factors such as supply-chain challenges, regulatory hurdles, and the social acceptability of energy infrastructure development limit the rate of clean energy and associated infrastructure deployment (such as transmission), then the share of clean generation achieved and the associated emissions benefits realized may be substantively reduced.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Finding of Adverse Effect and Proposed Mitigation for the Demolition of Building 23-530, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to demolish Building 23-530 in Mercury (Nevada State Historic Preservation Office [SHPO] Resource No. B15270), which is on the Nevada National Security Site (NNSS) in Nye County, Nevada. The purpose of the undertaking is related to the modernization of Mercury for future mission needs. The NNSA/NFO will implement this undertaking in accordance with the Programmatic Agreement Between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA. Building 23-530, a dormitory called Freedom Hall, was constructed in Mercury in 1982 and served as a support facility for nuclear testing for the last decade of the Cold War. The town of Mercury and the immediate surrounding area have been determined eligible for listing in the National Register of Historic Places (NRHP) as the Mercury Historic District (MHD, SHPO Resource No. D230) under Criteria A and C for their importance in supporting nuclear testing and scientific research from 1951 through 1992 (Reed 2019). Building 23-530 was identified as a contributing element to the MHD in a 2018 architectural survey of the district (Reno et al. 2018) and recorded on a Nevada Architectural Resource Assessment (ARA) form (Reno et al. 2017). Building 23-530 was also identified in Appendix C of the Mercury PA as a Category II contributing element. Category II properties are those that have several representatives in the MHD but may possess different engineering or architectural characteristics that distinguish them from other classes of similar elements. Building 23-530 is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and subject to the stipulations of the Mercury PA. The purpose of this letter report is to submit documentation related to the mitigation of the demolition of Building 23-530 (Nevada State Historic Preservation Office [SHPO] Resource No. B15270) in the Mercury Historic District (MHD, SHPO Resource No. D230) at the Nevada National Security Site (NNSS) in Nye County, Nevada. The dormitory is considered contributing to the significance of the district both for its historic importance in relation to nuclear testing under Criterion A and as a part of the distinctive design and construction of the district under Criterion C. This submission is intended to comply with the stipulations in the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA.

54 ENVIRONMENTAL SCIENCES↗

How Today's Hydropower Impacts Tomorrow's Grid: Counterfactual Scenarios Showing Grid Impacts if Hydropower Goes Away

Amidst ongoing discussions about hydropower removals, retirements, and reduced availability due to drought and other environmental considerations, it is important to understand the long-term effects of reduced hydropower resources on the U.S. electric grid. This analysis uses the Regional Energy Deployment System (ReEDS™) grid planning model to compare several representative scenarios of retiring hydropower and pumped storage hydropower (PSH) capacity over time and explore the overall implications on the U.S. grid from present day through 2050. Reduced hydropower capacity and generation is replaced by a mix of both fossil and non-fossil resources, including natural gas, wind, solar, and battery technologies. Additional natural gas usage leads to an increase in cumulative national electric sector carbon dioxide and criteria pollutant operating emissions of less than 1% in many scenarios but up to 4-5.3% in some cases. Total electric sector costs also increase by <1% in many scenarios but up to 3.6% in the most extreme scenarios where nearly all the hydropower and PSH fleet retires, equating to $\$$340 billion in undiscounted costs. National results indicate that absent additional interventions, retiring hydropower and PSH capacity could increase electric sector emissions and direct capital and operating costs. However, more focused analysis is required to evaluate specific asset-level, local, and regional implications, and a broader scope is necessary to weigh these electric sector impacts alongside economic, ecological, water management, and other cross-sectoral effects that could be either negative or positive.

14 SOLAR ENERGY↗

An Analysis of High Opportunity Geothermal Leasing Areas on BLM and USFS Lands

This analysis, conducted by the National Renewable Energy Laboratory (NREL) with support from the U.S. Department of Energy (DOE) Geothermal Technologies Office (GTO), models potential geothermal deployment on BLM and USFS land for the years 2025, 2030, 2035, and 2050 under various scenarios using the Renewable Energy Potential (reV) model and the Regional Energy Deployment System (ReEDS) model. This report identifies potential future high opportunity geothermal leasing areas (i.e., Best, Middle, and Least identified opportunities) based on available data for geothermal resource potential, natural resource conflicts, and transmission access. In addition, this analysis considers the impacts of the Energy Policy Act of 2005's (EPAct 2005's) default competitive leasing provisions, specifically the impact this may have had on geothermal resource discovery outside of known geothermal resource areas.

15 GEOTHERMAL ENERGY↗

Mitigation for Removal of Building 01-103 in the Area 1 Subdock, Nevada National Security Site, Nye County, Nevada

Building 01-103, the Drill Bit Repair Building was originally recorded as SHPO Resource No. B18848 in 2020 during an architectural survey of the Area 1 Subdock (Collins et al. 2022). It was recommended individually eligible for listing in the NRHP under Criteria A and C and contributing to the significance of the Area 1 Subdock Historic District. The SHPO concurred with these determinations in a letter dated April 29, 2022 (Reed 2022). The Drill Bit Repair Building retains all seven aspects of integrity. The location, materials, workmanship, feeling, and association have not changed since its original construction. The design was modified slightly in 1996 with the addition of a removable and non-destructive chain-link fence. Nearby buildings 01-101 and 01-102 were removed (Collins and Menocal 2020) but the other buildings and storage yards remain. Therefore, the integrity of setting has been changed, but not to the degree that the building no longer conveys its significance (see Figures 4 and 5 for comparison). Building 01-103 was constructed in 1985 to coincide with the relocation of the Area 3 Subdock to Area 1. The design for the new Subdock provided a centralized cluster of buildings surrounded by two large storage yards. The buildings included administrative and engineering office space, warehouses, a radiograph building, and Building 01-103 as the drill bit maintenance and repair building, among others. The Drill Bit Repair Building was critical to the success of underground nuclear testing and is eligible under Criterion A for its contribution to broad patterns of history by maintaining specially designed equipment for underground nuclear testing at the NNSS. It is also eligible under Criterion C as it is the only recorded example of a facility built specifically for the maintenance of big-hole drill bits on the NNSS. As it retains both significance and integrity, it remains individually eligible under Criteria A and C. In addition to its individual significance, the Drill Bit Repair Building also contributes to the significance of the Area 1 Subdock Historic District as a representative of a big-hole drilling support facility necessary for underground nuclear testing. The building and the equipment therein were designed specifically for testing at the NNSS, where much of the early technology and methods for big-hole drilling were developed. Its removal will result in not only the demolition of a contributing element but also a change in the physical features of the district’s setting that contribute to its historic significance. The change in setting will diminish the district’s integrity. However, the district still contains numerous examples of other buildings constructed for the purpose of supporting big-hole drilling and remains eligible under Criteria A and C.

54 ENVIRONMENTAL SCIENCES↗

Mitigation for Removal of Building 01-202681 in the Main Storage Yard of the Area 1 Subdock, Nevada National Security Site, Nye County, Nevada

The Main Storage Yard was originally recorded as SHPO Resource No. S2772 in 2020 during an architectural survey of the Area 1 Subdock (Collins et al. 2022). It was recommended individually eligible for listing in the NRHP under Criteria A and C and as contributing to the significance of the potential Area 1 Subdock Historic District. The SHPO concurred with these determinations in a letter dated April 29, 2022 (Reed). The Main Storage Yard retains all seven aspects of integrity. The location, design, materials, workmanship, feeling, and association have not changed since the original construction. Since the purpose of the yard is to maintain storage equipment that is actively being used, the design and feeling will change each time equipment is moved. Such actions reinforce the integrity of design and feeling. Buildings 01-101 and 01-102 were removed (Collins and Menocal 2020), but the other buildings and storage yard remain. Therefore, the setting has been changed, but not to the degree that the Main Storage Yard no longer conveys its significance (see Figures 4 and 5 for comparison). The Main Storage Yard was designed to facilitate the relocation of the Area 3 Subdock to Area 1 in 1985. The design for the overall Subdock provided a centralized cluster of buildings surrounded by two large storage yards. While the North Storage Yard largely serves as overflow storage, the Main Storage Yard holds the majority of drill rigs and drilling equipment needed to support big hole drilling. The Main Storage Yard and its contents were essential elements of the nuclear testing drilling program on the NNSS thus making it eligible for the NRHP under Criterion A for its contribution to broad patterns of history by storing specially designed equipment for underground nuclear testing at the NNSS. It is also eligible under Criterion C as it is an engineered landscape that now serves as an open-air repository of drilling technology and nuclear testing. In addition to its individual significance, the Main Storage Yard also contributes to the significance of the Area 1 Subdock Historic District as it showcases a variety of big-hole drilling equipment, support facilities, and warehouses that were specially designed for nuclear testing at the NNSS. Despite the demolition of two contributing elements to date, the district still contains numerous examples of other facilities with the purpose of supporting big-hole drilling; therefore, the district still remains eligible under Criteria A and C.

54 ENVIRONMENTAL SCIENCES↗

Highly Resolved Reference Projections of Building Energy Use for the Contiguous United States: Building Sector Energy Baselines, Projection Methods, and Results

This report describes one methodology of projecting energy consumption of the US residential and commercial building sectors using NREL's ResStock™ and ComStock™ as well as growth rates derived from EIA's Annual Energy Outlook (AEO). The impetus for this work is to provide an intermediate method for compiling demand-side sectoral energy projections that is suitable for grid-scale analysis, such as NREL's Standard Scenarios. ResStock and ComStock are physics-based and statistically representative building stock models of the US residential and commercial sector, respectively. Using the 2012 actual meteorological year (AMY) weather data, the sectoral energy baselines are simulated and then segmented along key dimensions (e.g., geography, dwelling/building type). The segmented results are then scaled using the corresponding annual growth rates derived from the 2021 AEO reference case to produce energy projections out to 2050. The compiled result is a demand-side grid model (dsgrid) data set suitable for use in NREL's large-scale grid models, such as the Regional Energy Deployment System (ReEDS). This simple projection method does not endogenously represent how the building stock could evolve through time. Most notably, it does not reflect large-scale electrification, for example, the conversion of space heating, water heating, clothes drying, and cooking from primary fossil fuels to electricity, as this is not part of AEO's reference case assumptions. Nonetheless this approach is more resolved and potentially extensible compared to the current method used by Standard Scenarios's reference case, which augments a sector's total load based on a single growth rate from AEO.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗