At least 289 records · Page 16

Fiber lasers and amplifiers for science and exploration at NASA Goddard Space Flight Center

We discuss present and near-term uses for high-power fiber lasers and amplifiers for NASA- specific applications including planetary topography and atmospheric spectroscopy. Fiber lasers and amplifiers offer numerous advantages for both near-term and future deployment of instruments on exploration and science remote sensing orbiting satellites. Ground-based and airborne systems provide an evolutionary path to space and a means for calibration and verification of space-borne systems. We present experimental progress on both the fiber transmitters and instrument prototypes for ongoing development efforts. These near-infrared instruments are laser sounders and lidars for measuring atmospheric carbon dioxide, oxygen, water vapor and methane and a pseudo-noise (PN) code laser ranging system. The associated fiber transmitters include high-power erbium, ytterbium, neodymium and Raman fiber amplifiers. In addition, we will discuss near-term fiber laser and amplifier requirements and programs for NASA free space optical communications, planetary topography and atmospheric spectroscopy.

Krainak, Michael A.↗

The discrimination between crude-oil spills and monomolecular sea slicks by an airborne lidar

Airborne lidar measurements were performed over a deployed monomolecular oleyl alcohol surface film ('slick'), the physicochemical characteristics of which are known to be similar to biogenic organic compounds secreted by plankton and fish, and adjacent 'clean' sea surfaces in the North Sea. In the presence of the slick, the suppression of the Raman backscatter at 381 nm and of two spectral bands indicative of water column fluorescent organic material at 414 and 482 nm were observed. This effect is explained by two possible mechanisms giving rise to a modification of the transmission or coupling of the laser beam into the water column: (1) the damping of capillary and short gravity water waves by the oleyl alcohol slick, and (2) the modification of the uppermost water layer by the oleyl alcohol film. The results obtained in the presence of a slick are compared with data measured over a Murban crude-oil spill with the same lidar system off the coast of the U.S.A. The consequences of the lidar-monomolecular film experiments with regard to the remote detection of crude-oil spills and oil-thickness measurements with an airborne laser fluorosensing system will be discussed.

Huehnerfuss, H.↗

Comparison of Lidar Methods for Remote Measurement of Air Pollutants

This paper presents quantitative comparisons of several single-ended lidar techniques for the remote measurement of gaseous pollutants. These techniques are divided into two groups. The first group is based on the measurement of energy scattered directly by the gas of interest. The gaseous scattering processes considered are ordinary fluorescence, resonance fluorescence (also called resonance scattering), Raman scattering, and resonant (or nearly resonant) Raman scattering. The second group is based on the measurement of a characteristic differential absorption produced by the gas of interest at two discrete wavelengths, using energy scattered back toward the receiver by a remote reflector other than the gas of interest. The remote reflector may be intermixed with the gas of interest, as is the case with aerosols and atmospheric gases (principally nitrogen), or they may be fixed reflectors such as terrestrial objects or retroflectors. The detectability of a given material will depend on the magnitude and characteristics of the optical interaction with that material. The main characteristics of interest are the cross section, the response time, and the spectral response of the material relative to both the transmit and receive functions of the lidar. These characteristics and their implications for remote sensing will be reviewed for the four direct scatter processes and for the differential absorption technique. The characteristic behavior of the direct backscatter technique is different from the differential absorption technique with respect to sensitivity, concentration of material, and the effect of range. For these reasons, the direct backscatter processes cannot be compared directly to the differential absorption technique. The two techniques can be compared for specific material and system configurations, however. This paper describes specific lidar system configurations and gives the calculated performance level for these systems in both the direct backscatter and differential absorption modes for a wide variety of pollutant monitoring situations. The results of this comparison of techniques indicate that the differential- absorption lidar technique can provide adequate range and sensitivity for a wide variety of pollution monitoring applications involving a number of interesting pollutant materials. No other single technique appears to provide these capabilities for such a wide range of materials.

Wright, M. L.↗

Lidar Measurements of the Thermic Structure in the Troposphere

Lidar measurements by UTHE (1972) and similar measurements with acoustic radar by HALL (1972) have shown, that short time variations in the troposphere can be determined. Aerosol backscatter measurements give the vertical structure. A series of such results shows the time variation of the tropospheric structure. The Figure is an example for a measuring period during half an hour in summer 1972 (1 pulse per minute). These variations were produced by humidity variations. For example, at humidity variations from 75% to 77% aerosol particles with 1 micron radius change their radii during 50 to 100 milliseconds. By lidar technique it is possible to determine this effect qualitatively. With a pulse repetition rate of 1 per second we plan to investigate the thermic structure at different weather conditions. By simultaneous measurements of the nitrogen Raman component it would be possible to compare the short time variations by temperature and humidity. The influence of wind can be determined by scanning a defined region (region or space). The meteorologist is interested in results of short time variations in the troposphere (microscale). By this remote sensing method he can get these values continuously.

Werner, Ch.↗

Lidar Systems - Where We Are

A general review of the past ten years of LIDAR system development will be presented. Equipment problems and many of their solutions are discussed. These include problems with photomultipliers, lasers, interference filters, data acquisition, etc. Calibration and alignment techniques are also presented. Instrumentation for multi-wavelength, Raman, doppler, monostatic and bistatic techniques being used by various researchers are described. New developments and a gaze into the future are included.

McCormick, M. P.↗

Airborne discrimination between ice and water - Application to the laser measurement of chlorophyll-in-water in a marginal ice zone

The concurrent active-passive measurement capabilities of the NASA Airborne Oceanographic Lidar have been used to (1) discriminate between ice and water in a large ice field within the Greenland Sea and (2) achieve the detection and measurement of chlorophyll-in-water by laser-induced and water-Raman-normalized pigment fluorescence. Passive upwelled radiances from sea ice are significantly stronger than those from the neighboring water, even when the optical receiver field-of-view is only partially filled with ice. Thus, weaker passive upwelled radiances, together with concurrently acquired laser-induced spectra, can rather confidently be assigned to the intervening water column. The laser-induced spectrum can then be processed using previously established methods to measure the chlorophyll-in-water concentration. Significant phytoplankton patchiness and elevated chlorophyll concentrations were found within the waters of the melting ice compared to ice-free regions just outside the ice field.

Hoge, Frank E.↗

Atmospheric Instrument Systems and Technology in the Goddard Earth Sciences Division

Studies of the Earth’s atmosphere require a comprehensive set of observations that rely on instruments flown on spacecraft, aircraft, and balloons as well as those deployed on the surface. Within NASA’s Goddard Space Flight Center (GSFC) Earth Sciences Division-Atmospheres, laboratories and offices maintain an active program of instrument system development and observational studies that provide: 1) information leading to a basic understanding of atmospheric processes and their relationships with the Earth’s climate system, 2) prototypes for future flight instruments, 3) instruments to serve as calibration references for satellite missions, and 4) instruments for future field validation campaigns that support ongoing space missions. Our scientists participate in all aspects of instrument activity, including component and system design, calibration techniques, retrieval algorithm development, and data processing systems. The Atmospheres Program has well-equipped labs and test equipment to support the development and testing of instrument systems, such as a radiometric calibration and development facility to support the calibration of ultraviolet and visible (UV/VIS), space-borne solar backscatter instruments. This document summarizes the features and characteristics of 46 instrument systems that currently exist or are under development. The report is organized according to active, passive, or in situ remote sensing across the electromagnetic spectrum. Most of the systems are considered operational in that they have demonstrated performance in the field and are capable of being deployed on relatively short notice. Other systems are under study or of low technical readiness level (TRL). The systems described herein are designed mainly for surface or airborne platforms. However, two Cubesat systems also have been developed through collaborative efforts. The Solar Disk Sextant (SDS) is the single balloon-borne instrument. The lidar systems described herein are designed to retrieve clouds, aerosols, methane, water vapor pressure, temperature, and winds. Most of the lasers operate at some wavelength combination of 355, 532, and 1064 nm. The various systems provide high sensitivity measurements based on returns from backscatter or Raman scattering including intensity and polarization. Measurements of the frequency (Doppler) shift of light scattered from various atmospheric constitutes can also be made. Microwave sensors consist of both active (radar) and passive (radiometer) systems. These systems are important for studying processes involving water in various forms. The dielectric properties of water affect microwave brightness temperatures, which are used to retrieve atmospheric parameters such as rainfall rate and other key elements of the hydrological cycle. Atmosphere radar systems operate in the range from 9.6 GHz to 94 GHz and have measurement accuracies from -5 to 1 dBZ; radiometers operate in the 50 GHz to 874 GHz range with accuracies from 0.5 to 1 degree K; conical and cross-track scan modes are used. Our passive optical sensors, consisting of radiometers and spectrometers, collectively operate from the UV into the infrared. These systems measure energy fluxes and atmospheric parameters such as trace gases, aerosols, cloud properties, or altitude profiles of various species. Imager spatial resolution varies from 37 m to 400 m depending on altitude; spectral resolution is as small as 0.5 nm. Many of the airborne systems have been developed to fly on multiple aircraft.

Platnick, Steven E.↗

AROTEL - An Airborne Ozone, Aerosol and Temperature Lidar

The AROTEL instrument is a collaboration between scientists at NASA, Goddard Space Flight Center and NASA Langley Research Center. The instrument was designed and constructed to be flown on the NASA DC-8, and to measure vertical profiles of ozone, temperature and aerosol. The instrument transmits radiation at 308, 355, 532, and 1064 nm. Depolarization is measured at 532 nm. In addition to the transmitted wavelengths, Raman scattered signals at 332 nm and 387 nm are also collected. The instrument was installed aboard the DC-8 for the SAGE III Ozone Loss and Validation Experiment (SOLVE) which deployed from Kiruna, Sweden, during the winter of 1999-2000 to study the polar stratosphere. During this time, profile measurements of polar stratospheric clouds, ozone and temperature were made. This paper provides an instrumental overview as an introduction to several data papers to be presented in the poster sessions. In addition to samples of the measurements, examples will be given to establish the quality of the various data products.

McGee, Thomas J.↗

Technology Advancement for Active Remote Sensing of Carbon Dioxide from Space Using the ASCENDS CarbonHawk Experiment Simulator: First Results

The ASCENDS CarbonHawk Experiment Simulator (ACES) is a newly developed lidar developed at NASA Langley Research Center and funded by NASA's Earth Science Technology Office (ESTO) Instrument Incubator Program (IIP) that seeks to advance technologies critical to measuring atmospheric column carbon dioxide (CO2) mixing ratios in support of the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission. The technology advancements targeted include: (1) increasing the power-aperture product to approach ASCENDS mission requirements by implementing multi-aperture telescopes and multiple co-aligned laser transmitters; (2) incorporating high-efficiency, high-power Erbium-Doped Fiber Amplifiers (EDFAs); (3) developing and incorporating a high-bandwidth, low-noise HgCdTe detector and transimpedence amplifier (TIA) subsystem capable of long-duration autonomous operation on Global Hawk aircraft, and (4) advancing algorithms for cloud and aerosol discrimination. The ACES instrument architecture is being developed for operation on high-altitude aircraft and will be directly scalable to meet the ASCENDS mission requirements. These technologies are critical towards developing not only spaceborne instruments but also their airborne simulators, with lower platform requirements for size, mass, and power, and with improved instrument performance for the ASCENDS mission. ACES transmits five laser beams: three from commercial EDFAs operating near 1.57 microns, and two from the Exelis oxygen (O2) Raman fiber laser amplifier system operating near 1.26 microns. The three EDFAs are capable of transmitting up to 10 watts average optical output power each and are seeded by compact, low noise, stable, narrow-linewidth laser sources stabilized with respect to a CO2 absorption line using a multi-pass gas absorption cell. The Integrated-Path Differential Absorption (IPDA) lidar approach is used at both wavelengths to independently measure the CO2 and O2 column number densities and retrieve the average column CO2 mixing ratio. The ACES receiver uses three fiber-coupled 17.8-cm diameter athermal telescopes. The transmitter assembly consists of five fiber-coupled laser collimators and an associated Risley prism pair for each laser to co-align the outgoing laser beams and to align them with the telescope field of view. The backscattered return signals collected by the three telescopes are combined in a fiber bundle and sent to a single low noise detector. The detector/TIA development has improved the existing detector subsystem by increasing its bandwidth to 4.7 MHz from 500 kHz and increasing the duration of autonomous, service-free operation periods from 4 hours to >24 hours. The new detector subsystem enables the utilization of higher laser modulation rates, which provides greater flexibility for implementing advanced thin-cloud discrimination algorithms as well as improving range-determination resolution and error reduction. The cloud/aerosol discrimination algorithm development by Langley and Exelis features a new suite of algorithms for the minimization/elimination of bias errors in the return signal induced by the presence of intervening thin clouds. Multiple laser modulation schemes are being tested in an effort to significantly mitigate the effects of thin clouds on the retrieved CO2 column amounts. Full instrument development concluded in the spring of 2014. After ground range tests of the instrument, ACES successfully completed six test flights on the Langley Hu-25 aircraft in July, 2014, and recorded data at multiple altitudes over land and ocean surfaces with and without intervening clouds. Preliminary results from these test flights will be presented in this paper.

Obland, Michael D.↗

Sensorium: commissioning abundant sensors with augmented reality and QR codes

In the future, it will be possible to build high-quality models of building interiors based on data from a dense fleet of sensors reporting on air volumes much smaller than a room or zone. To enable such models, we are creating technologies that allow a fleet of sensors to be commissioned quickly at low cost. Our sensor commissioning process builds a 3D model of each building interior that includes sensor positions and sensor networking information such as sensor MAC addresses. It employs multiple technologies, including augmented reality, LiDAR, QR codes, and computer vision. Sensors can be commissioned at more than 10x the speed and at less than one tenth the cost of traditional approaches.

Bier, Eric A.↗

Stimulated Raman shifting of the Nd:YAG fourth harmonic (266 nm) in H2, HD, and D2

The dependence of the first Stokes stimulated Raman conversion efficiency of fourth-harmonic radiation from a Nd:YAG laser at 266 nm has been studied for the isotopic species H2, HD, and D2 as a function of gas pressure and laser energy using a low numerical aperture (about 0.0045) pumping geometry. While the laser energy threshold for first Stokes conversion varies significantly among the species, photon conversion efficiencies of at least 50 percent can be achieved for all of them for laser pump energies at 266 nm of 50 mJ/pulse or less. This study provides a new measurement of the differential cross section for stimulated Raman scattering in HD of 8.1 + or - 2.4 x 10 to the -29th sq cm/sr at 266 nm and at high pressures, and agreement is found with previous measurements of the cross sections for H2 and D2. The results have been used to optimize the laser transmitter system for a differential-absorption lidar to measure tropospheric ozone concentration profiles.

Haner, David A.↗

A considerable effect of stratospheric aerosol on lidar-detected ozone profile and a three-wavelength inversion technique for both ozone and aerosol

As far as the Differential Absorption Lidar (DIAL) technique is concerned, it is important that the off-line wavelength is close to the on-line wavelength in order to avoid a messy computation of the atmospheric aerosol scattering. However, the two wavelengths of ozone-DIAL are usually considerably different. Usually, an excimer laser of 308nm (on-line) and Raman shifting of 353nm or the third harmonic of a Nd-YAG laser with 355nm (off-line) are selected for measurements of the stratospheric ozone, and there is a difference of 45nm or 47nm between them. Because of the difference there is a difference in the atmospheric scatterings of the two wavelengths. This can cause some error in the retrieved ozone profile if the aerosol scattering is neglected. This paper is devoted to a study of the effect of the stratospheric aerosol on the ozone solution, and a three-wavelength detection technique is proposed for obtaining the more exact ozone profile and the aerosol profile in the stratosphere.

Qiu, Jinhuan↗

Pressure Measurements Using an Airborne Differential Absorption Lidar: Analysis of the Systematic Error Sources - Part 1

Remote airborne measurements of the vertical and horizontal structure of the atmospheric pressure field in the lower troposphere are made with an oxygen differential absorption lidar (DIAL). A detailed analysis of this measurement technique is provided which includes corrections for imprecise knowledge of the detector background level, the oxygen absorption fine parameters, and variations in the laser output energy. In addition, we analyze other possible sources of systematic errors including spectral effects related to aerosol and molecular scattering interference by rotational Raman scattering and interference by isotopic oxygen fines.

Flamant, Cyrille N.↗

Ozone Measurements with the US EPA UV-DIAL: Preliminary Results

A compact airborne down-looking lidar system was developed at the Environmental Protection Agency in Las Vegas. This differential absorption lidar (DIAL) was designed to simultaneously measure range-resolved concentrations of ozone (O3) and sulfur dioxide (SO2) in the lower troposphere, together with an indication of the aerosol distribution. The five laser wavelengths (i.e., lambda(sub 1) = 277 nm, lambda(sub 2) = 292 nm, lambda(sub 3) = 313 nm, lambda(sub4) = 319 nm, lambda(sub 5) = 369 nm) were generated via Raman conversion of a focused KrF excimer laser. The system is currently installed in a truck-based mobile laboratory. For the ground testing, an opening in the truck floor together with a folding mirror under the truck makes a horizontal, or upwardly inclined direction of measurement possible. Initial ground testing has been performed in the vicinity of a Desert Research Institute (DRI) ambient air monitoring site, located at Cottonwood Cove approximately 85 km south east of Las Vegas, Nevada. At this site O3 and SO2 concentrations are continuously monitored with an average accuracy better than +/- 10 percent. A temporary ozone measurement station with identical accuracy was set up at a distance to get a second point of comparison for the range-resolved DIAL measurements.

Moosmueller, H.↗

Lidar stratospheric ozone measurements at the observatoire de Haute Provence (France)

Strastospheric ozone monitoring is of particular importance to confirm present day theories predicting a maximal ozone depletion, due to chlorofluorocarbon emission, in the 35 to 45 km altitude range. Measurements presently rely on both ground based and satellite-borne passive experiments. Such systems have been recently shown to have intrinsic limitations mainly due to atmospheric aerosol presence and calibration problems. During the last few years, active lidar profiling of the ozone vertical distribution by the Differential Absorption Laser technique (DIAL) in the UV wavelength range has been developed using two different laser sources: a Nd-YAG pumped dye laser which enables a large tuning range of the UV emitted wavelengths; and exciplex laser sources using xenon chloride as an active medium and emitting at 308 nm, the off wavelength being usually generated by Raman shifting techniques. Advantages and limitations of using both of these systems are briefly discussed.

Godin, S.↗

Water-vapor absorption line measurements in the 940-nm band by using a Raman-shifted dye laser

We report water-vapor absorption line measurements that are made by using the first Stokes radiation (930-982 nm) with HWHM 0.015/cm generated by a narrow-linewidth, tunable dye laser. Forty-five absorption line strengths are measured with an uncertainty of 6 percent and among them are fourteen strong lines that are compared with previous measurements for the assessment of spectral purity of the light source. Thirty air-broadened linewidths are measured with 8 percent uncertainty at ambient atmospheric pressure with an average of 0.101/cm. The lines are selected for the purpose of temperature-sensitive or temperature-insensitive lidar measurements. Results for these line strengths and linewidths are corrected for broadband radiation and finite laser linewidth broadening effects and compared with the high-resolution transmission molecular absorption.

Chu, Zhiping↗

Polarization Maintaining, Very-Large-Mode Area, Er Fiber Amplifier for High Energy Pulses at 1572.3 nm

We demonstrate the first polarization maintaining, very-large-mode-area Er-doped fiber amplifier with ~1000 square micron effective area. The amplifier is core pumped by a Raman fiber laser and is used to generate single frequency one microsecond pulses with pulse energy of 368 microJoules, M2 of 1.1, and polarization extinction greater than 20 dB. The amplifier operates at 1572.3 nm, a wavelength useful for trace atmospheric CO2 detection.

solid-state laser↗

NASA Tech Briefs, September 2011

Topics covered include: Fused Reality for Enhanced Flight Test Capabilities; Thermography to Inspect Insulation of Large Cryogenic Tanks; Crush Test Abuse Stand; Test Generator for MATLAB Simulations; Dynamic Monitoring of Cleanroom Fallout Using an Air Particle Counter; Enhancement to Non-Contacting Stress Measurement of Blade Vibration Frequency; Positively Verifying Mating of Previously Unverifiable Flight Connectors; Radiation-Tolerant Intelligent Memory Stack - RTIMS; Ultra-Low-Dropout Linear Regulator; Excitation of a Parallel Plate Waveguide by an Array of Rectangular Waveguides; FPGA for Power Control of MSL Avionics; UAVSAR Active Electronically Scanned Array; Lockout/Tagout (LOTO) Simulator; Silicon Carbide Mounts for Fabry-Perot Interferometers; Measuring the In-Process Figure, Final Prescription, and System Alignment of Large; Optics and Segmented Mirrors Using Lidar Metrology; Fiber-Reinforced Reactive Nano-Epoxy Composites; Polymerization Initiated at the Sidewalls of Carbon Nanotubes; Metal-Matrix/Hollow-Ceramic-Sphere Composites; Piezoelectrically Enhanced Photocathodes; Iridium-Doped Ruthenium Oxide Catalyst for Oxygen Evolution; Improved Mo-Re VPS Alloys for High-Temperature Uses; Data Service Provider Cost Estimation Tool; Hybrid Power Management-Based Vehicle Architecture; Force Limit System; Levitated Duct Fan (LDF) Aircraft Auxiliary Generator; Compact, Two-Sided Structural Cold Plate Configuration; AN Fitting Reconditioning Tool; Active Response Gravity Offload System; Method and Apparatus for Forming Nanodroplets; Rapid Detection of the Varicella Zoster Virus in Saliva; Improved Devices for Collecting Sweat for Chemical Analysis; Phase-Controlled Magnetic Mirror for Wavefront Correction; and Frame-Transfer Gating Raman Spectroscopy for Time-Resolved Multiscalar Combustion Diagnostics.

Source record↗