Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Source Replacement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

SU-E-T-108: Development of a Novel Clinical Neutron Dose Monitor for Proton Therapy Based On Twin TLD500 Chips in a Small PE Moderator

Purpose: In proton therapy, it could be desirable to measure out-of-field fast neutron doses at critical locations near and outside the patient body. Methods: The working principle of a novel clinical neutron dose monitor is verified by MCNPX simulation. The device is based on a small PE moderator of just 5.5cm side length for easy handling covered with a thermal neutron suppression layer. In the simulation, a polystyrene phantom is bombarded with a standard proton beam. The secondary thermal neutron flux produced inside the moderator by the impinging fast neutrons from the treatment volume is estimated by pairs of α-Al2O3:C (TLD500) chips which are evaluated offline after the treatment either by TL or OSL methods. The first chip is wrapped with 0.5mm natural Gadolinium foil converting the thermal neutrons to gammas via (n,γ) reaction. The second chip is wrapped with a dummy material. The chip centers have a distance of 2cm from each other. Results: The simulation shows that the difference of gamma doses in the TLD500 chips is correlated to the mean fast neutron dose delivered to the moderator material. Different outer shielding materials have been studied. 0.5mm Cadmium shielding is preferred for cost reasons and convenience. Replacement of PE moderator material by other materials like lead or iron at any place is unfavorable. The spatial orientation of the moderator cube is uncritical. Using variance reduction techniques like splitting/Russian roulette, the TLD500 gamma dose simulation give positive differences up to distances of 0.5m from the treatment volume. Conclusion: Applicability and basic layout of a novel clinical neutron dose monitor are demonstrated. The monitor measures PE neutron doses at locations outside the patient body up to distances of 0.5m from the treatment volume. Tissue neutron doses may be calculated using neutron kerma factors.

07 ISOTOPE AND RADIATION SOURCES↗

JPL lithium doped solar cell development program

One of the most significant problems encountered in the use of silicon solar cells in space is the sensitivity of the device to electron and proton radiation exposure. The p-diffused-into-n-base solar cells were replaced with the more radiation tolerant n-diffused-into-p-base solar cells. Another advancement in achieving greater radiation tolerance was the discovery that the addition of lithium to n-base silicon resulted in what appeared to be annealing of radiation-induced defects. This phenomenon is being exploited to develop a high efficiency radiation resistant lithium-doped solar cell. Lithium-doped solar cells fabricated from oxygen-lean and oxygen-rich silicon were obtained with average initial efficiencies of 11.9% at air mass zero and 28 C, as compared to state-of-the-art n-p cells fabricated from 10 ohm cm silicon with average efficiencies of 11.3% under similar conditions. Lithium-doped cells demonstrated the ability to withstand three to five times the fluence of 1-MeV electrons before degrading to a power equivalent to state-of-the-art solar cells. The principal investigations are discussed with respect to fabrication of high efficiency radiation resistant lithium-doped cells, including starting material, p-n junction diffusion, lithium source introduction, and lithium diffusion.

Berman, P. A.↗

Lunar and Planetary Science XXXVI, Part 20

The topics include: 1) Virtual Reality Technology as a Tool to Enhance Collaboration Between Space Exploration and Public Outreach: The Case Using the Mars Exploration Rover Images; 2) Atmospheric Electron-induced X-Ray Spectrometer (AEXS) Instrument Development; 3) Impact of Low Thermal Conductivity Layers on the Bulk Conductivity of a Martian Crustal Column; 4) Impacting Classroom Teachers Through Long-Term Professional Development; 5) Oxygen, Ca, and Ti Isotopic Compositions of Hibonite-bearing Inclusions; 6) Phenomenological Excitation Functions of Xe Isotopes with Protons on Nuclei of Cs, La and Ce; 7) Double-Diffusive Convection and Other Modes of Salinity-modulated Heat and Material Transport in Europa s Ocean; 8) Slope Morphologies of the Hellas Mensae Constructs, Eastern Hellas Planitia, Mars; 9) Development of Polygonal Thermal Contraction Patterns in a South Polar Trough, Mars 3 Years of Observations; 10) Martian Relevance of Dehydration and Rehydration in the Mg-Sulfate System; 11) Formation of Martian Volcanic Provinces by Lower Mantle Flushing? 12) Can Glasses Help Us to Unravel the Origin of Barred Olivine Chondrules? 13) Loki Patera: A Magma Sea Story; 14) Compositions of Partly Altered Olivine and Replacement Serpentine in the CM2 Chondrite QUE93005; 15) Model of Light Scattering by Lunar Regolith at Moderate Phase Angles: New Results; 16) Radiation Resistance of a Silicone Polymer Grease Based Regolith Collector for the HERA Near-Earth Asteroid Sample Return Mission; 17) Analysis of the Tectonic Lineaments in the Ganiki Planitia (V14) Quadrangle, Venus; 18) Nanometer-sized Diamonds from AGB Stars; 19) Quantifying Exact Motions Along Lineaments on Europa; 20) Geometry of Thrust Faults Beneath Amenthes Rupes, Mars; 21) Mapping of the Physical Characteristics and Mineral Composition of a Superficial Layer of the Moon or Mars and Ultra-Violet Polarimetry from the Orbital Station; 22) Negative Searches for Evidence of Aqueous Alteration on Asteroid Surfaces; 23) What Processes Have Shaped Basalt Boulders on Earth and Mars? Studies of Feature Persistence Using Facet Mapping and Fractal Analysis; 24) The Popigai Fluidizites: Dense Water Inclusions in Lechatelierite; Evidence for Shock-generated Carbonate and Hydrous Silicate Melts; 25) Missing Xenon Problem and Climate of the Early Earth; and 26) More on Magnetic Spectra from Correlated Crustal Sources on Mars

Source record↗

Small Gas Bubble Experiment for Mitigation of Cavitation Damage and Pressure Waves in Short-pulse Mercury Spallation Targets

Populations of small helium gas bubbles were introduced into a flowing mercury experiment test loop to evaluate mitigation of beam-pulse induced cavitation damage and pressure waves. The test loop was developed and thoroughly tested at the Spallation Neutron Source (SNS) prior to irradiations at the Los Alamos Neutron Science Center - Weapons Neutron Research Center (LANSCE-WNR) facility. Twelve candidate bubblers were evaluated over a range of mercury flow and gas injection rates by use of a novel optical measurement technique that accurately assessed the generated bubble size distributions. Final selection for irradiation testing included two variations of a swirl bubbler provided by Japan Proton Accelerator Research Complex (J-PARC) collaborators and one orifice bubbler developed at SNS. Bubble populations of interest consisted of sizes up to 150 m in radius with achieved gas void fractions in the 10^-5 to 10^-4 range. The nominal WNR beam pulse used for the experiment created energy deposition in the mercury comparable to SNS pulses operating at 2.5 MW. Nineteen test conditions were completed each with 100 pulses, including variations on mercury flow, gas injection and protons per pulse. The principal measure of cavitation damage mitigation was surface damage assessment on test specimens that were manually replaced for each test condition. Damage assessment was done after radiation decay and decontamination by optical and laser profiling microscopy with damaged area fraction and maximum pit depth being the more valued results. Damage was reduced by flow alone; the best mitigation from bubble injection was between half and a quarter that of flow alone. Other data collected included surface motion tracking by three laser Doppler vibrometers (LDV), loop wall dynamic strain, beam diagnostics for charge and beam profile assessment, embedded hydrophones and pressure sensors, and sound measurement by a suite of conventional and contact microphones.

bubbles↗

Anthropogenic Air Pollution Observed Near Dust Source Regions in Northwestern China During Springtime 2008

Trace gases and aerosols were measured in Zhangye (39.082degN, 100.276degE, 1460 m a.s. 1.), a rural site near the Gobi deserts in northwestern China during spring 2008. Primary trace gases (CO:265 ppb; SO2:3.4 ppb; NO(*y): 4.2 ppb; hereafter results given as means of hourly data) in the area were lower than in eastern China, but still indicative of marked anthropogenic emissions. Sizable aerosol mass concentration (153 micro-g/cu m) and light scattering (159/Mm at 500 nm) were largely attributable to dust emissions, and aerosol light absorption (10.3/Mm at 500 nm) was dominated by anthropogenic pollution. Distinct diurnal variations in meteorology and pollution were induced by the local valley terrain. Strong daytime northwest valley wind cleaned out pollution and was replaced by southeast mountain wind that allowed pollutants to build up overnight. In the afternoon, aerosols had single scattering albedo (SSA, 500 mn) of 0.95 and were mainly of supermicron particles, presumably dust, while at night smaller particles and SSA of 0.89-0.91 were related to Pollution. The diverse local emission sources were characterized: the CO/SO2, CO/NO(y), NO(y)/SO2 (by moles), and BC/CO (by mass) ratios for small point sources such as factories were 24.6-54.2, 25.8-35.9, 0.79-1.31, and 4.1-6.1 x 10(exp -3), respectively, compared to the corresponding inventory ratios of 43.7-71.9, 23.7-25.7, 1.84-2.79, and 3.4-4.0 x 10(exp -3) for the industrial sector in the area. The mixing between dust and pollution can be ubiquitous in this region. During a dust storm shown as an example, pollutants were observed to mix with dust, causing discernible changes in both SSA and aerosol size distribution. Further interaction between dust and pollutants during transport may modify the properties of dust particles that are critical for their large-scale impact on radiation, clouds, and global biogeochemical cycles.

Li, Can↗

Semi-global approach for propagation of the time-dependent Schrödinger equation for time-dependent and nonlinear problems

A detailed exposition of highly efficient and accurate method for the propagation of the time-dependent Schrödinger equation is presented. The method is readily generalized to solve an arbitrary set of ODE's. The propagation is based on a global approach, in which large time-intervals are treated as a whole, replacing the local considerations of the common propagators. The new method is suitable for various classes of problems, including problems with a time-dependent Hamiltonian, nonlinear problems, non-Hermitian problems and problems with an inhomogeneous source term. In this paper, a thorough presentation of the basic principles of the propagator is given. We give also a special emphasis on the details of the numerical implementation of the method. For the first time, we present the application for a non-Hermitian problem by a numerical example of a one-dimensional atom under the influence of an intense laser field. The efficiency of the method is demonstrated by a comparison with the common Runge–Kutta approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AmBe Final Project Report on Simulations

In this project we examine the feasibility of using a dense plasma focus (DPF) to accelerate helium into a beryllium target as a way to replace AmBe sources with an accelerator source of similar neutron spectrum. Our group at LLNL, in collaboration with Voss Scientific, developed a fully kinetic model of DPF z-pinch plasmas in order to accurately predict ion beam spectra and neutron yields. Our group uses this tool as a guide for experiments, and also as a predictive tool to access regimes that would be time-consuming or expensive to try experimentally. In this report, we summarize the simulations that were performed during the course of this feasibility study. These simulations include the calculation of a DPF neutron spectrum based on a simulated ion beam spectrum, a pressure scan with optimized anode length, a sensitivity study to see how much the model depends on the MHD switch time, and initial simulations of the plasma breakdown.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Workshop introduction

The Department of Energy's National Nuclear Security Administration's Global Threat Reduction Initiative (GTRI) has three subprograms that directly reduce the nuclear/radiological threat; Convert (Highly Enriched Uranium), Protect (Facilities), and Remove (Materials). The primary mission of the Off-Site Source Recovery Project (OSRP) falls under the 'Remove' subset. The purpose of this workshop is to provide a venue for joint-technical collaboration between the OSRP and the Nuclear Radiation Safety Service (NRSS). Eisenhower's Atoms for Peace initiative and the Soviet equivalent both promoted the spread of the paradoxical (peaceful and harmful) properties of the atom. The focus of nonproliferation efforts has been rightly dedicated to fissile materials and the threat they pose. Continued emphasis on radioactive materials must also be encouraged. An unquantifiable threat still exists in the prolific quantity of sealed radioactive sources (sources) spread worldwide. It does not appear that the momentum of the evolution in the numerous beneficial applications of radioactive sources will subside in the near future. Numerous expert studies have demonstrated the potentially devastating economic and psychological impacts of terrorist use of a radiological dispersal or emitting device. The development of such a weapon, from the acquisition of the material to the technical knowledge needed to develop and use it, is straightforward. There are many documented accounts worldwide of accidental and purposeful diversions of radioactive materials from regulatory control. The burden of securing sealed sources often falls upon the source owner, who may not have a disposal pathway once the source reaches the end of its useful life. This disposal problem is exacerbated by some source owners not having the resources to safely and compliantly store them. US Nuclear Regulatory Commission (NRC) data suggests that, in the US alone, there are tens of thousands of high-activity (IAEA Category I and II) sources in thousands of devices; and there are many more tens of thousands of smaller sources scattered among thousands of other NRC licensees. As a result of the ubiquitous nature and undeterminable number of current and legacy sources, even in developed countries they can be abandoned, disposed of in a haphazard manner, lost, stolen, and/or otherwise fallout of regulatory control. Supply and demand of sources, being market based, is more or less fluid. Normative security of radioactive sources exists, but varies in each country, and is loosely implemented through non-legally binding recommendations and standards provided by International Atomic Energy Agency technical documents and cooperation and through bilateral efforts such as this workshop where we share best-practices with one another. Much of the reason for the difficulty in securing sealed sources rests in the enormous need for their beneficial applications in the medical, industrial, and agricultural sectors. Alternative technologies to replace high-risk sources continue to be explored, but very few of these alternative solutions have reached the development stage for common usage and distribution. The beneficial uses of sources must be allowed to continue; however, to minimize the potential for their misuse, current controls and regulating mechanisms must be constantly evaluated to ensure the benefits gained outweigh potential risks. From a global perspective, an evaluation and modification of requirements over the entire life cycle of sources from their manufacture to their final disposition is required. The proper removal and disposal of vulnerable disused or orphan sources is essential to maintaining a safe operating environment. One of our goals in this workshop is to share our methodologies for recovering sources and learn how they differ or are similar to the challenges faced in recovering, storing, and disposing of sources in the Republic of Georgia . The suggestions we will make are flexible in allowing for the imperfect situations and capabilities we have all encountered in source recovery efforts. We have designed a table-top exercise specifically to address your concerns about the prevention and mitigation of contaminated facilities, soil, containers, and sources. Our discussion begins with an overview and video of the OSRP along with a brief on our projects ongoing international cooperation and activities. A presentation will be given by the NRSS illustrating the successes and challenges of source management in Georgia. A brief overview will be given of selected significant cases of the intentional misuse of sources. This will be followed by two comprehensive discussions focusing on the decontamination from the facility perspective down to the issues of container and source leakage. The second day will begin with the abovementioned table-top exercise on contamination control. On the third day, a second presentation from the NRSS will open up the session.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Mixed Beam Murine Harderian Gland Tumorigenesis: Predicted Dose-Effect Relationships if neither Synergism nor Antagonism Occurs

Complex mixed radiation fields exist in interplanetary space, and not much is known about their latent effects on space travelers. In silico synergy analysis default predictions are useful when planning relevant mixed-ion-beam experiments and interpreting their results. These predictions are based on individual dose-effect relationships (IDER) for each component of the mixed-ion beam, assuming no synergy or antagonism. For example, a default hypothesis of simple effect additivity has often been used throughout the study of biology. However, for more than a century pharmacologists interested in mixtures of therapeutic drugs have analyzed conceptual, mathematical and practical questions similar to those that arise when analyzing mixed radiation fields, and have shown that simple effect additivity often gives unreasonable predictions when the IDER are curvilinear. Various alternatives to simple effect additivity proposed in radiobiology, pharmacometrics, toxicology and other fields are also known to have important limitations. In this work, we analyze upcoming murine Harderian gland (HG) tumor prevalence mixed-beam experiments, using customized open-source software and published IDER from past single-ion experiments. The upcoming experiments will use acute irradiation and the mixed beam will include components of high atomic number and energy (HZE). We introduce a new alternative to simple effect additivity, "incremental effect additivity", which is more suitable for the HG analysis and perhaps for other end points. We use incremental effect additivity to calculate default predictions for mixture dose-effect relationships, including 95% confidence intervals. We have drawn three main conclusions from this work. 1. It is important to supplement mixed-beam experiments with single-ion experiments, with matching end point(s), shielding and dose timing. 2. For HG tumorigenesis due to a mixed beam, simple effect additivity and incremental effect additivity sometimes give default predictions that are numerically close. However, if nontargeted effects are important and the mixed beam includes a number of different HZE components, simple effect additivity becomes unusable and another method is needed such as incremental effect additivity. 3. Eventually, synergy analysis default predictions of the effects of mixed radiation fields will be replaced by more mechanistic, biophysically-based predictions. However, optimizing synergy analyses is an important first step. If mixed-beam experiments indicate little synergy or antagonism, plans by NASA for further experiments and possible missions beyond low earth orbit will be substantially simplified.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

X-ray structure of the metcyano form of dehaloperoxidase from Amphitrite ornata: evidence for photoreductive dissociation of the iron-cyanide bond

X-ray crystal structures of the metcyano form of dehaloperoxidase-hemoglobin (DHP A) from Amphitrite ornata (DHPCN) and the C73S mutant of DHP A (C73SCN) were determined using synchrotron radiation in order to further investigate the geometry of diatomic ligands coordinated to the heme iron. The DHPCN structure was also determined using a rotating-anode source. The structures show evidence of photoreduction of the iron accompanied by dissociation of bound cyanide ion (CN{sup -}) that depend on the intensity of the X-ray radiation and the exposure time. The electron density is consistent with diatomic molecules located in two sites in the distal pocket of DHPCN. However, the identities of the diatomic ligands at these two sites are not uniquely determined by the electron-density map. Consequently, density functional theory calculations were conducted in order to determine whether the bond lengths, angles and dissociation energies are consistent with bound CN{sup -} or O{sub 2} in the iron-bound site. In addition, molecular-dynamics simulations were carried out in order to determine whether the dynamics are consistent with trapped CN{sup -} or O{sub 2} in the second site of the distal pocket. Based on these calculations and comparison with a previously determined X-ray crystal structure of the C73S-O{sub 2} form of DHP [de Serrano et al. (2007), Acta Cryst. D63, 1094-1101], it is concluded that CN{sup -} is gradually replaced by O{sub 2} as crystalline DHP is photoreduced at 100 K. The ease of photoreduction of DHP A is consistent with the reduction potential, but suggests an alternative activation mechanism for DHP A compared with other peroxidases, which typically have reduction potentials that are 0.5 V more negative. The lability of CN{sup -} at 100 K suggests that the distal pocket of DHP A has greater flexibility than most other hemoglobins.

36 MATERIALS SCIENCE↗

Note: Gratings on low absorbing substrates for x-ray phase contrast imaging

Grating based X-ray phase contrast imaging is on the verge of being applied in clinical settings. To achieve this goal, compact setups with high sensitivity and dose efficiency are necessary. Both can be increased by eliminating unwanted absorption in the beam path, which is mainly due to the grating substrates. Fabrication of gratings via deep X-ray lithography can address this issue by replacing the commonly used silicon substrate with materials with lower X-ray absorption that fulfill certain boundary conditions. Gratings were produced on both graphite and polymer substrates without compromising on structure quality. These gratings were tested in a three-grating setup with a source operated at 40 kVp and lead to an increase in the detector photon count rate of almost a factor of 4 compared to a set of gratings on silicon substrates. As the visibility was hardly affected, this corresponds to a significant increase in sensitivity and therefore dose efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of anomalous reactor activity using antineutrino count evolution over the course of a reactor cycle

This paper analyzes the sensitivity of antineutrino count rate measurements to changes in the fissile content of civil power reactors. Such measurements may be useful in IAEA reactor safeguards applications. We introduce a hypothesis testing procedure to identify statistically significant differences between the antineutrino count rate evolution of a standard 'baseline' fuel cycle and that of an anomalous cycle, in which plutonium is removed and replaced with an equivalent fissile worth of uranium. The test would allow an inspector to detect anomalous reactor activity, or to positively confirm that the reactor is operating in a manner consistent with its declared fuel inventory and power level. We show that with a reasonable choice of detector parameters, the test can detect replacement of 82 kg of plutonium in 90 days with 95% probability, while controlling the false positive rate at 5%. We show that some improvement on this level of sensitivity may be obtained by various means, including use of the method in conjunction with existing reactor safeguards methods. We also identify a necessary and sufficient minimum daily antineutrino count rate and a maximum tolerable background rate to achieve the quoted sensitivity, and list examples of detectors in which such rates have been attained.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simulation of computed radiography with imaging plate detectors

Computed radiography (CR) using phosphor imaging plate detectors is taking an increasing place in Radiography Testing. CR uses similar equipment as conventional radiography except that the classical X-ray film is replaced by a numerical detector, called image plate (IP), which is made of a photostimulable layer and which is read by a scanning device through photostimulated luminescence. Such digital radiography has already demonstrated important benefits in terms of exposure time, decrease of source energies and thus reduction of radioprotection area besides being a solution without effluents. This paper presents a model for the simulation of radiography with image plate detectors in CIVA together with examples of validation of the model. The study consists in a cross comparison between experimental and simulation results obtained on a step wedge with a classical X-ray tube. Results are proposed in particular with wire Image quality Indicator (IQI) and duplex IQI.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Model-based dose calculations for {sup 125}I lung brachytherapy

Purpose: Model-baseddose calculations (MBDCs) are performed using patient computed tomography (CT) data for patients treated with intraoperative {sup 125}I lung brachytherapy at the Mayo Clinic Rochester. Various metallic artifact correction and tissue assignment schemes are considered and their effects on dose distributions are studied. Dose distributions are compared to those calculated under TG-43 assumptions. Methods: Dose distributions for six patients are calculated using phantoms derived from patient CT data and the EGSnrc user-code BrachyDose. {sup 125}I (GE Healthcare/Oncura model 6711) seeds are fully modeled. Four metallic artifact correction schemes are applied to the CT data phantoms: (1) no correction, (2) a filtered back-projection on a modified virtual sinogram, (3) the reassignment of CT numbers above a threshold in the vicinity of the seeds, and (4) a combination of (2) and (3). Tissue assignment is based on voxel CT number and mass density is assigned using a CT number to mass density calibration. Three tissue assignment schemes with varying levels of detail (20, 11, and 5 tissues) are applied to metallic artifact corrected phantoms. Simulations are also performed under TG-43 assumptions, i.e., seeds in homogeneous water with no interseed attenuation. Results: Significant dose differences (up to 40% for D{sub 90}) are observed between uncorrected and metallic artifact corrected phantoms. For phantoms created with metallic artifact correction schemes (3) and (4), dose volume metrics are generally in good agreement (less than 2% differences for all patients) although there are significant local dose differences. The application of the three tissue assignment schemes results in differences of up to 8% for D{sub 90}; these differences vary between patients. Significant dose differences are seen between fully modeled and TG-43 calculations with TG-43 underestimating the dose (up to 36% in D{sub 90}) for larger volumes containing higher proportions of healthy lung tissue. Conclusions: Metallic artifact correction is necessary for accurate application of MBDCs for lung brachytherapy; simpler threshold replacement methods may be sufficient for early adopters concerned with clinical dose metrics. Rigorous determination of voxel tissue parameters and tissue assignment is required for accurate dose calculations as different tissue assignment schemes can result in significantly different dose distributions. Significant differences are seen between MBDCs and TG-43 dose distributions with TG-43 underestimating dose in volumes containing healthy lung tissue.

61 RADIATION PROTECTION AND DOSIMETRY↗

Thermal enhancement cartridge heater modified (TECH Mod) tritium hydride bed development, Part 1 - Design and fabrication

The Savannah River Site (SRS) tritium facilities have used first generation (Gen1) LaNi{sub 4.25}Al{sub 0.75} (LANA0.75) metal hydride storage beds for tritium absorption, storage, and desorption. The Gen1 design utilizes hot and cold nitrogen supplies to thermally cycle these beds. Second and third generation (Gen2 and Gen3) storage bed designs include heat conducting foam and divider plates to spatially fix the hydride within the bed. For thermal cycling, the Gen2 and Gen3 beds utilize internal electric heaters and glovebox atmosphere flow over the bed inside the bed external jacket for cooling. The currently installed Gen1 beds require replacement due to tritium aging effects on the LANA0.75 material, and cannot be replaced with Gen2 or Gen3 beds due to different designs of these beds. At the end of service life, Gen1 bed desorption efficiencies are limited by the upper temperature of hot nitrogen supply. To increase end-of-life desorption efficiency, the Gen1 bed design was modified, and a Thermal Enhancement Cartridge Heater Modified (TECH Mod) bed was developed. Internal electric cartridge heaters in the new design to improve end-of-life desorption, and also permit in-bed tritium accountability (IBA) calibration measurements to be made without the use of process tritium. Additional enhancements implemented into the TECH Mod design are also discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Prospective Activities outlined for Regulatory Approval in Ghana Overview

The Ghana Research Reactor-1 (GHARR-1) is one of Chinese’s Miniature Neutron Source Reactor (MNSR) which was purchased under a tripartite agreement between Ghana, China and the IAEA. The reactor was installed in 1994 and has since been in operation without any incident. It has been used chiefly for Neutron Activation Analysis (NAA) and Training of students in the field of Nuclear Engineering. The GHARR-1 has been earmarked for the Conversion of Core from HEU to LEU which is in accordance with the GTRI program and other related and/or associated programs. Over the past few years the National Nuclear Research Institute (NNRI), the Operating Organization of the Research Reactor for the Ghana Atomic Energy Commission (GAEC), has undertaken various tasks in order to implement the replacement of the reactor core. After completion, of the neutronic calculations, results showed that that an LEU fuel of 12.5% enrichment was desirable. However, recent developments have shown that an LEU fuel with 13% enrichment will be fabricated by the manufacturers, which is captured in a fuel specification document sent to NNRI by the CIAE. It is therefore imperative that all neutronic and thermal hydraulic calculation be done again to help acquire regulatory approval. Furthermore, the radiation exposure to personnel involved in the conversion must be estimated to help convince our regulators. This paper outlines the processes and activities that will enable us meet regulatory requirements.

Abrefah, R. G.↗

Radiochemical Methodology Applied To Determination of gamma-Emitting Radionuclides In Waste Samples From IEA-R1 Reactor - 17265

The Brazilian reactor IEA-R1 has been in operation since 1957. It is an open pool-type nuclear research reactor, operating at 2 to 5 MW that uses water as coolant, moderator and biological shield. Polypropylene filter cartridges are part of the water treatment system of the reactor and become radioactive as they remove suspended solid material from the cooling water during the operation of the reactor. Annually, the replacement of the filters from the reactor's water treatment system generates about 36 units. The development of a method for the characterization of the radionuclides present in the filters is required for routine operation in the Radioactive Waste Management Facility (RWMF) in order to determine the radioisotopic inventory of the waste packages. Wastes from nuclear reactors contain transuranic elements, activation and fission products, only few of them emitting gamma radiation measurable by simple gamma scanning methods. The method of the Scaling Factors (SF) uses empirically determined proportions between the concentrations of Difficult to Measure (DTM) radionuclides and that of easily measurable gamma emitters called Key Nuclide (KN), to calculate DTM concentrations. The objective of this study is to describe a method of the dissolution of the filter cartridges for determination of gamma emitting radionuclides. To determine the activity of a sample by means of of gamma spectrometry, it is necessary previous knowledge of the efficiency curve for a given geometry, which can be obtained by calibrating the efficiency and energy of the detector. The need to dissolve the filter cartridges has arisen given the difficulty in obtaining a standard source with the same filter geometry. Therefore, for this work, the calibration curve was constructed using a mixed gamma-ray standard with known activities, same geometry, density, physical state and chemical composition of the source to be analyzed. A sample with background count (BG) was prepared and analyzed under the same conditions as the samples and the result was subtracted from the results obtained for each filter sample. After many tests, it was possible to establish a method for the dissolution of filter cartridges for the determination of gamma-emitting radionuclides. A mixed gamma-ray standard was produced in liquid form, containing the following radionuclides: {sup 241}Am, {sup 137}Cs and {sup 60}Co, which have photo-peaks at the following energies: 59.54, 661.66 and 1332.49 keV, respectively. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design of the new extraction grid for the NIO1 negative ion source

NIO1 is a compact source of negative ions jointly developed by RFX and INFN, to study the physics of production and acceleration of H{sup −} beams. Negative ions, up to 120 mA of current, are extracted from a radiofrequency driven plasma, by means of a gridded electrode (plasma grid, PG) featuring 9 apertures arranged in a 3x3 square lattice. The same aperture pattern is replicated in the following electrodes, allowing ion acceleration up to 60 keV. All electrodes are realized in copper, by electro-deposition technique, leaving empty slots in the metal to place magnets and to flow water for the grid cooling. The first set of electrodes was completed, installed in the source and tested. At the same time, an upgrade of the extraction system was carried out, in order to optimize the beam optics and to explore alternative electrostatic configurations. In particular, the accelerator will be modified by completely replacing the EG grid, exploiting the modularity of NIO1. The new electrode will feature other slots in between apertures, to place additional magnets. This allows testing different magnetic configurations, to optimize electron filtering and residual ion deflection. The present paper describes the theoretical activities driving the design of these new extractors, carried out with most updated numerical codes, and exploiting the synergy with the refined modeling of the 40 A ITER negative ion sources, under development at Consorzio RFX. Beam simulations are performed both with tracing codes (SLACCAD and OPERA) and with particle in cell codes (ACCPIC)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗