Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Development of international standards for instrumentation used for detection of illicit trafficking of radioactive material

Subcommittee 45B Radiation Protection Instrumentation of the International Electrotechnical Commission (IEC) is charged with the development of international standards for instrumentation used for monitoring of illicit trafficking of radioactive material through international boarders and territories, as well as inside countries. Currently three IEC standards are published. The international participation and the main characteristics of the following three standards are discussed and presented: IEC 62327 Hand-held Instruments for the Detection and Identification of Radionuclides and Additionally for the Indication of Ambient Dose Equivalent Rate from Photon Radiation , IEC 62401 Alarming Personal Radiation Devices for Detection of Illicit Trafficking of Radioactive Material and IEC 62244 Installed Radiation Monitors for the Detection of Radioactive and Special Nuclear Materials at National Borders .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparing Thick Target Neutron Yield Calculations for Alphas on F-19 using MCNP6 1.1 Beta with TENDL 2012 Libraries

Because of the heritage of MCNPX, the first production release of MCNP6{sup TM} used physics models, instead of ACE (A Compact Evaluated Nuclear Data File) formatted libraries, for simulating the transport of alpha particles at all energies, as MCNPX could not yet read ACE formatted light ion libraries. For non-Coulombic interactions, the physics models have suggested minimums of ∼ 20-200 MeV. The first production release of MCNP6, MCNP6{sup TM} 1.0, was still capable of transporting alphas to low energies; however, the physics models resulted in poor prediction of inelastic reactions at energies below the suggested minimums. This poorer prediction at low energies resulted in orders of magnitude lower neutron yields for events resulting from light ion interactions at low energies. For example, F-19(α,n)Na-22 from U-234 decay in UF{sub 6} produced poor neutron production results. Modeling these types of interactions correctly is vital for signal analysis for nonproliferation safeguards and nuclear security as well as for correctly characterizing source terms for radiation protection and shielding calculations. The TALYS computer code was developed to simulate nuclear reactions involving neutrons, photons, protons, deuterons, tritons, alphas and He-3 particles, in the 1 keV - 200 MeV energy range. TENDL is a nuclear data library, which provides the output of the TALYS nuclear model code system for direct use in applications (i.e. ACE formatted cross sections). Since 2008, TENDL had publicly provided ACE formatted libraries for alpha transport; however, not until the release of MCNP6{sup TM} 1.1 beta, had MCNP6 publicly possessed the capability to read such libraries. At the Radiation Protection and Shielding Division topical meeting in 2014, initial testing of MCNP6 1.1 beta showed that MCNP6 using TENDL 2012 resulted in poor prediction when compared to the compilation of experiment data provided in R. Heaton et al. Further comparisons for PuBe sources, using the MCNP6 1.1 beta spontaneous decay alpha feature coupled with alpha transport, were also given in the winter American Nuclear Society meeting in 2014, where the results showed large discrepancies with measured data. For F-19(α,n)Na-22 interactions, the R. Heaton et al. paper is a conglomeration of several important references; and the data provided by R. Heaton et al. used a numerical fit of the excitation function provided by Norman et al.. Norman et al. has recently published their (α,n) thick target yield data for PbF{sub 2} in tabular form, backing out the thick target yields of F-19(α,n)Na-22 and computing F{sub 2} and UF{sub 6} thick target neutron yields (as supplements to the PbF{sub 2} data). Here we compared measured thick target yields of E. B. Norman et al. to MCNP6 1.1 beta using TENDL 2012 libraries. Deterministically backing out the thick target yield from measured values involves using the stopping power. MCNP uses either the SPAR code or an interpolation of the Spar code and Bethe-Boch formula for computing stopping powers. As a result one may believe that these separate methods will arrive at separate thick target yields independent of the production cross section. In our MCNP calculations, we simulated the alpha until the alpha completely stopped in the medium. The energy loss in the condensed history algorithm is not continuous but discrete and related to the stopping powers. Because the neutron production yield is energy dependent, the energy loss dictates the emission of secondary neutrons; and therefore the difference in stopping powers used may have some slight effect on the yield difference. For this study, we chose to use the default condensed history algorithm setup, while future studies should address tightening steps in the condensed history algorithm to prove whether or not choice of stopping power actually matters. The fact that all 5 evaluated isotopic compositions resulted in different thick target yield percent differences does warrant this type of investigation. A typical user may not be only interested in integral emission, taking 10 s to 100 s of processor hours to simulate, but rather a timely generation of the spectra. Such an application would require biasing the production of secondaries from alpha sources such that millions of secondaries could be produced, emulating a converged energy dependent spectra. Neutron production biasing from alpha sources does not currently exist; however, developing a biasing algorithm for neutron production from alpha sources should be investigated in the future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The 21st LH Gray Conference (June 4-6, 2008)

The 21st LH Gray Conference, organised by the LH Gray Trust with the Society for Radiological Protection, brought together international experts in radiobiology, epidemiology and risk assessment, and scientists involved in diagnostic and therapeutic radiation exposure. The meeting - held in Edinburgh, Scotland 4-6 June 2008 - aimed to raise awareness, educate and share knowledge of important issues in radiation protection. A distinguished group of speakers discussed topics which included: non-targeted effects of radiation, exposure to high natural background radiation, non-cancer effects in Japanese bomb survivors, lessons learnt from Chernobyl, radiation in the workplace, biokinetic modelling, uncertainties in risk estimation, issues in diagnostic medical exposures, lessons leant from the polonium-210 incidence and how the radiobiology-radiation oncology community is needed to help society prepare for potential future acts of radiation terrorism. The conference highlighted the importance, relevance and topicality of radiobiology today.

59 BASIC BIOLOGICAL SCIENCES↗

Screening of the Protective Actions under the Laser Irradiation of Bio-Objects: Experimental Results and Physical Model

The screening of protective radiations that occur during laser radiation of biological tissues have been experimentally studied. The metallic and dielectric screens with different shape have been used for screening. The physical model of generation of the secondary radiation that generates the protective effects, which lead to a substantial increase in the environmental resistance of living organisms placed nearby, has been suggested. It has been assumed that this radiation is mainly concentrated in the frequency range lower than 10 GHz.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiation Doses to Members of the U.S. Population from Ubiquitous Radionuclides in the Body: Part 2, Methods and Dose Calculations

This paper is part two of a three-part series investigating annual effective doses to residents of the United States from intakes of ubiquitous radionuclides, including radionuclides occurring naturally, radionuclides whose concentrations are technologically enhanced, and anthropogenic radionuclides. This series of papers explicitly excludes intakes from inhaling 222Rn, 220Rn, and their short-lived decay products; it also excludes intakes of radionuclides in occupational and medical settings. Part one reviewed, summarized, characterized, and grouped all published and some unpublished data for U.S. residents on ubiquitous radionuclide concentrations in tissues and organs. Assumptions about equilibrium with long-lived parents are made for the 28 other radionuclides in these series lacking data. This paper describes the methods developed to group the collected data into source regions described in the Radiation Dose Assessment Resource (RADAR) dosimetric methodology. Methods for converting the various units of data published over 50 years into a standard form are developed and described. Often, meaningful values of uncertainty of measurements were not published so that variability in data sets is confounded with measurement uncertainty. A description of the methods developed to estimate variability is included in this paper. The data described in part one are grouped by gender and age to match the RADAR dosimetric phantoms. Within these phantoms, concentration values are grouped into source tissue regions by radionuclide, and they are imputed for source regions lacking tissue data. Radionuclide concentrations are then imputed for other phantoms’ source regions with missing concentration values, and the uncertainties of the imputed values are increased. The content concentrations of hollow organs are calculated, and activities are apportioned to the bone source regions using assumptions about each radionuclide’s bone-seeking behavior. The data sets are then ready to be used to estimate equivalent doses to target tissues from these source regions. The target tissues are then mapped to lists of tissues with International Commission on Radiation Protection (ICRP) tissue weighting factors, or they are mapped to surrogate tissue regions when there is no direct match. Effective doses, using ICRP tissue weighting factors recommended in 1977, 1990, and 2007, are calculated from tissue and organ equivalent doses.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluating importance maps for TRIPOLI-4{sup R} using deterministic or on-line methods - 25446

Variance reduction is a key ingredient for solving radiation-protection problems with Monte-Carlo particle-transport codes. Many variance-reduction methods require the definition of an importance map and exhibit optimal performance if the importance map is given by the adjoint flux, the solution of the adjoint Boltzmann equation. This paper presents the implementation of the Consistent Adjoint-Driven Importance Sampling (CADIS) methodology via a coupling between the TRIPOLI-4 R Monte-Carlo particle-transport code and the IDT deterministic solver, Additionally, we describe the implementation of a new TRIPOLI-4 R score that makes it possible to estimate the adjoint flux during a direct Monte-Carlo calculation. These new features are expected to simplify the solution of difficult shielding problems. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

A new tubular ironless linear induction motor using non-interrupted winding method

The ironless linear induction motor device can be used for any application which requires a large motion span or rotation restrictedly by the ironless feature due to the strong magnetic field environment. One of the possible applications is ITER diagnostics shutters. The tokamak reactor systems have a severe radiation issue during the operation. The traditional Kapton-insulated wires have significantly lower radiation resistance than an expected large radiation dose at ITER Motion Stark Effect (MSE) shutter location. Furthermore, the traditional single-sided linear induction motor winds the wire to make the N-turn pitch coils independently and then connect them in series to make a one-phase winding. Therefore, it is a big challenge to make so many radiation-protection connectors in such a limited space as inside the vacuum vessel of fusion reactors. The approved mineral-insulated kinds of cables need a large bend radius for the end turns, so the traditional single-sided linear motor with two-layer three-phase windings need to be upgraded to the tubular linear motors. The new proposed tubular ironless linear induction motor can not only overcome the large bend radius issue with the mineral-insulated cables but also allow the motor coils wound continuously around the tubular-shaped stator, forward and backward N times to make a N-turn winding for each phase, in order to resolve the radiation protection issue with the winding connection. The 3D transient Maxwell electromagnetic model with a tubular three-phase linear induction motor has been analyzed. Furthermore, this paper will present the detailed design and winding method of ironless linear induction motor actuators, and results of the 3D transient numerical simulation of the actuator performance.

Ironless↗

Application of adaptive multilevel splitting on coupled neutron-photon TRIPOLI-4{sup R} Monte Carlo simulations - 25427

In the context of radiation protection simulations, the Adaptive Multilevel Splitting (AMS) algorithm is a challenging variance reduction (VR) technique that has been recently investigated in the field of particle transport simulation. It has been implemented in the forthcoming version 11 of the Monte Carlo code TRIPOLI-4{sup R} and successfully tested in neutron-only and photon-only configurations. This paper addresses the application of the AMS algorithm to coupled simulations, and particularly to neutron-photon Monte Carlo calculations. The branching process occurring during the Monte Carlo coupled transport is taken into account in the new coupled-AMS algorithm and is explained in this paper. Two different neutron-photon configurations are then investigated, leading to a comparison of the coupled-AMS algorithm with the analog simulation on the one hand, and with the Exponential Transform (ET) on the other hand, which is the standard VR technique of TRIPOLI-4. Gains up to 30 are obtained in terms of Figure of Merit relatively to the analog simulation, which is about 4 to 6 times more efficient than the ET method for these configurations. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

A Fission-like Neutron Spectrum Shaping Assembly based on D-T Generator

For nearly five decades, 252 Cf sources have been used for testing and calibration over a wide range of neutron detection devices used for nuclear safety and radiation protection. However, the vastly increased cost of 252 Cf sources, its short half-life, and concerns about future shortage have prompted nuclear facilities and radiological calibration laboratories that rely on high-intensity neutron sources to seek alternatives. While there appear to be no other radionuclide neutron sources that would match the 252 Cf performance characteristics, all of them, including 252 Cf, present similar concerns in terms of hazards, safety, and security. As a possible solution to this issue, the Pacific Northwest National Laboratory (PNNL) developed a low-risk, cost-efficient alternative to produce fission-like spectra based on commercially available deuterium-tritium (D-T) neutron generators. The alternative of producing a fission-like neutron spectrum without any fissionable materials or beryllium would enable the nuclear facilities across the entire complex to eliminate their reliance on high intensity 252 Cf sources for nuclear safety and radiation protection applications, substantially reducing risks and associated costs. This report describes efforts of designing the spectrum shaping assembly, its construction and characterization of the neutron field produced. Performance of this newly developed D-T generator based neutron field is demonstrated via calibration of a criticality detector, neutron survey instruments, and personal dosimeters verified against current standardized fields produced by 252 Cf spontaneous fission sources.

42 ENGINEERING↗

Angular distribution of neutron production by proton and carbon-ion therapeutic beams

Carbon-ion beams are increasingly used in the clinical practice for external radiotherapy treatments of deep-seated tumors. At therapeutic energies, carbon ions yield significant secondary products, including neutrons, which may be of concern for the radiation protection of the patient and personnel. We simulated the neutron yield produced by proton and carbon-ion pencil beams impinging on a clinical phantom at three different angles: 15°, 45° and 90°, with respect to the beam axis. We validated the simulated results using the measured response of organic scintillation detectors. We compared the results obtained with FLUKA 2011.2 and MCNPX 2.7.0 based on three different physics models: Bertini, Isabel, and CEM. Over the different ions, energies, and angles, the FLUKA simulation results agree better with the measured data, compared to the MCNPX results. Simulations of carbon ions at low angles exhibit both the highest deviation from measured data and inter-model discrepancy, which is probably due to the different treatment of the pre-equilibrium stage. The reported neutron yield results could help in the comparison of carbon-ion and proton treatments in terms of secondary neutron production for radiation protection applications.

60 APPLIED LIFE SCIENCES↗

Radiological Studies for the LCLS Beam Abort System

The Linac Coherent Light Source (LCLS), a pioneer hard x-ray free electron laser is currently under construction at the Stanford Linear Accelerator Center. It is expected that by 2009 LCLS will deliver laser pulses of unprecedented brightness and short length, which will be used in several forefront research applications. This ambitious project encompasses major design challenges to the radiation protection like the numerous sources and the number of surveyed objects. In order to sort those, the showers from various loss sources have been tracked along a detailed model covering 1/2 mile of LCLS accelerator by means of the Monte Carlo intra nuclear cascade codes FLUKA and MARS15. This article covers the FLUKA studies of heat load; prompt and residual dose and environmental impact for the LCLS beam abort system.

43 PARTICLE ACCELERATORS↗

MARSAME Radiological Release Report for Archaeological Artifacts Excavated from Area L

In 1991 Los Alamos National Laboratory’s (LANL’s) cultural resources team excavated archaeological site LA 4618 located at Technical Area 54, within Material Disposal Area L (MDA L). MDA L received non-radioactive chemical waste from the early 1960s until 1985. Further development of the MDA required excavation of several cultural sites under National Historic Preservation Act requirements; artifacts from these sites have been subsequently stored at LANL. The LANL cultural resources group would now like to release these artifacts to the Museum of Indian Arts and Culture in Santa Fe for curation. The history of disposal at Area L suggests that the artifact pool is unlikely to be chemically contaminated and LANL staff washed each artifact at least once following excavation. Thus, it is unlikely that the artifacts present a chemical hazard. LANL’s Environmental Stewardship group (EPC-ES) has evaluated the radiological survey results for the Area L artifact pool and found that the items described in this report meet the criteria for unrestricted radiological release under Department of Energy (DOE) Order 458.1 Radiation Protection of the Public and the Environment and are candidates for release without restriction from LANL control. This conclusion is based on the known history of MDA L and on radiation survey data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-P-03: The Australian Clinical Dosimetry Service, a Bespoke National Solution

Purpose: The Australian Clinical Dosimetry Service, (ACDS) was a pilot program to enable the Australian Government to determine whether a locally designed audit program was suitable for mitigating dosimetric error risk to radiotherapy patients within Australia. The outcomes from four years of operations will be presented and discussed with a focus why and how the pilot requirements were met. The consequnces of success will be considered, the lessons learnt from the pilot program and how they are impacting the future ACDS design, operation and engagement with stakeholders. Methods: The ACDS was designed over 2010/11 by experts drawn from the three professions in consultation with the national Department of Health. The list of outcomes required over a three year pilot was expressed in a Memorandum of Understanding, (MoU) between Health and the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) which hosted the ACDS. Results: The ACDS has achieved all the MoU requirements. This paper describes how the staff within the ACDS engaged with the professional clinical workforce and provided a successful and functioning audit service. It identifies the strengths and weaknesses within the MoU and the ACDS structure and how the ACDS resolved a number of conflicting issues. It identifies the successes within the ACDS and how these were achieved. It provides details to assist and advise those seeking to design or modify national or regional auditing programs. Finally the paper reviews potential futures for the ACDS. Conclusion: The raw number of audits and outcomes indicate that the ACDS has met the MoU auditing requirements. The reasons for the ACDS’ success are highly dependent on: attracting quality staff who can respond with agility to changing situations, a high level of communication with the professional community, a high level of engagement by the community and an interested and engaged Federal Department. The Australian Clinical Dosimetry Service is a joint initiative between the Australian Department of Health and the Australian Radiation Protection and Nuclear Safety Agency.

60 APPLIED LIFE SCIENCES↗

Upgrade of the PNNL TEPC and Multisphere Spectrometer

The Pacific Northwest National Laboratory (PNNL) has used two types of instruments, the tissue equivalent proportional counter (TEPC) and the multisphere spectrometer for characterizing neutron radiation fields in support of neutron dosimetry at the Hanford site. The US Department of Energy recently issued new requirements for radiation protection standards in 10 CFR 835 which affect the way that neutron dose equivalent rates are evaluated. In response to the new requirements, PNNL has upgraded the analyses used in conjunction with the TEPC and multisphere. The analysis software for the TEPC was modified for this effort, and a new analysis code was selected for the multisphere. These new analysis techniques were implemented and tested with measurement data that had been collected in previous measurements. In order to test the effectiveness of the changes, measurements were taken in PNNL’s Low Scatter Room using 252Cf sources in both unmoderated and D2O-moderated configurations that generate well-characterized neutron fields. The instruments were also used at Los Alamos National Laboratory (LANL), in their Neutron Free-in-Air calibration room, also using neutron sources that generate well-characterized neutron fields. The results of the software modifications and the measurements are documented in this report. The TEPC measurements performed at PNNL agreed well with accepted dose equivalent rates using the traditional analysis, agreeing with the accepted value to within 13% for both unmoderated and moderated 252Cf sources. When the new analysis was applied to the TEPC measurement data, the results were high compared to the new accepted value. A similar pattern was seen for TEPC measurements at LANL. Using the traditional analysis method, results for all neutron sources showed good agreement with accepted values, nearly always less than 10%. For the new method of analysis, however, the TEPC responded with higher dose equivalent rates than accepted, by as much as 25%. The reason for the overresponse is that there is very little attenuation of the neutrons by tissue, so it cannot match the effect of attenuation by 1 cm of tissue called for in the new standards. This could be corrected with a modified instrument with a thicker wall, or by analytical means that would need to be developed. The multisphere spectrometer performed reasonably well both at PNNL and at LANL. It could produce a neutron spectrum that was similar to the accepted spectrum, and total flux values were usually within 15% of the accepted values. Dose equivalent rates were usually within 18% of the accepted values. The average energies, however, were usually lower than the accepted values. The performance of this instrument could be much better than seen in this study. If PNNL were to add some moderating spheres to its measurement set and calculate a new set of instrument response functions, performance could be improved. The multisphere could then be a more useful instrument for assessing the dose equivalent rate in the workplace.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the neutron leakage from a dedicated intraoperative radiation therapy electron linear accelerator and a conventional linear accelerator for 9, 12, 15(16), and 18(20) MeV electron energies

The issue of neutron leakage has recently been raised in connection with dedicated electron-only linear accelerators used for intraoperative radiation therapy (IORT). In particular, concern has been expressed about the degree of neutron production at energies of 10 MeV and higher due to the need for additional, perhaps permanent, shielding in the room in which the device is operated. In particular, three mobile linear accelerators available commercially offer electron energies at or above the neutron threshold, one at 9 MeV, one at 10 MeV, and the third at 12 MeV. To investigate this problem, neutron leakage has been measured around the head of two types of electron accelerators at a distance of 1 m from the target at azimuthal angles of 0 deg., 45 deg., 90 deg., 135 deg., and 180 deg. The first is a dedicated electron-only (nonmobile) machine with electron energies of 6 (not used here), 9, 12, 15, and 18 MeV and the second a conventional machine with electron energies of 6 (also not used here), 9, 12, 16, and 20 MeV. Measurements were made using neutron bubble detectors and track-etch detectors. For electron beams from a conventional accelerator, the neutron leakage in the forward direction in Sv/Gy is 2.1x10{sup -5} at 12 MeV, 1.3x10{sup -4} at 16 MeV, and 4.2x10{sup -4} at 20 MeV, assuming a quality factor (RBE) of 10. For azimuthal angles >0 deg., the leakage is almost angle independent [2x10{sup -6} at 12 MeV; (0.7-1.6)x10{sup -5} at 16 MeV, and (1.6-2.9)x10{sup -5} at 20 MeV]. For the electron-only machine, the neutron leakage was lower than for the conventional linac, but also independent of azimuthal angle for angles >0 deg. : ([0 deg. : 7.7x10{sup -6} at 12 MeV; 3.0x10{sup -5} at 15 MeV; 1.0x10{sup -4} at 18 MeV]; [other angles: (2.6-5.9)x10{sup -7} at 12 MeV; (1.4-2.2)x10{sup -6} at 15 MeV; (2.7-4.7)x10{sup -6} at 18 MeV]). Using the upper limit of 6x10{sup -7} Sv/Gy at 12 MeV for the IORT machine for azimuthal angles >0 deg. and assuming a workload of 200 Gy/wk and an inverse square factor of 10, the neutron dose equivalent is calculated to be 0.012 mSv/wk. For the primary beam at 12 MeV (0 deg. ), the 10x higher dose would be compensated by the attenuation of a primary beam stopper in a mobile linear accelerator. These neutron radiation levels are below regulatory values (National Council on Radiation Protection and Measurements, 'Limitation of exposure to ionizing radiation', NCRP Report No. 116, NCRP Bethesda, MD, 1993)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radioactive Waste Management in Central Asia - 12034

After the collapse of the Soviet Union the newly independent states in Central Asia (CA) whose regulatory bodies were set up recently are facing problems with the proper management of radioactive waste and so called 'nuclear legacy' inherited from the past activities. During the former Soviet Union (SU) period, various aspects of nuclear energy use took place in CA republics of Kazakhstan, Kyrgyzstan, Tajikistan and Uzbekistan. Activities range from peaceful use of energy to nuclear testing for example at the former Semipalatinsk Nuclear Test Site (SNTS) in Kazakhstan, and uranium mining and milling industries in all four countries. Large amounts of radioactive waste (RW) have been accumulated in Central Asia and are waiting for its safe disposal. In 2008 the Norwegian Radiation Protection Authority (NRPA), with the support of the Norwegian Ministry of Foreign Affairs, has developed bilateral projects that aim to assist the regulatory bodies in Kazakhstan, Kyrgyzstan Tajikistan, and Uzbekistan (from 2010) to identify and draft relevant regulatory requirements to ensure the protection of the personnel, population and environment during the planning and execution of remedial actions for past practices and radioactive waste management in the CA countries. The participating regulatory authorities included: Kazakhstan Atomic Energy Agency, Kyrgyzstan State Agency on Environmental Protection and Forestry, Nuclear Safety Agency of Tajikistan, and State Inspectorate on Safety in Industry and Mining of Uzbekistan. The scope of the projects is to ensure that activities related to radioactive waste management in both planned and existing exposure situations in CA will be carried out in accordance with the international guidance and recommendations, taking into account the relevant regulatory practice from other countries in this area. In order to understand the problems in the field of radioactive waste management we have analysed the existing regulations through the so called 'Threat assessment' in each CA country which revealed additional problems in the existing regulatory documents beyond those described at the start of our ongoing bilateral projects in Kazakhstan, Kirgizistan Tajikistan and Uzbekistan. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Work to save dose: contrasting effective dose rates from radon exposure in workplaces and residences against the backdrop of public and occupational limits

Office workers are exposed to radon while at work and at home. Though there has been a multitude of studies reporting the measurements of radon concentrations and potential lung and effective doses associated with radon and progeny exposure in homes, similar studies on the concentrations and subsequent effective dose rates in the non-mine workplaces are lacking. Additionally, there are few, if any, comparative analyses of radon exposures at more 'typical' workplace with residential exposures within the same county. The purposes of this study were to measure radon concentrations in office and residential spaces in the same county and explore the radiation dose implications. Sixty-five track-etch detectors were deployed in office spaces and 47 were deployed in residences, all within Los Alamos County, New Mexico, USA. The sampling periods for these measurements were generally about three months. The measured concentrations were used to calculate and compare effective dose rates resulting from exposure while at work and at home. Results showed that full-time office workers receive on average about 8 times greater exposure at home than while in the office (2.3 mSv yr-! versus 0.3 mSv yr-!). The estimated effective dose rate for a more homebound person was about 3 mSv yr-!. Estimating effective doses from background radon exposure in the same county as Los Alamos National Laboratory, with thousands of'radiological workers,' highlights interesting contrasts in radiation protection standards that span public and occupational settings. For example, the effective dose rate from background radon exposure in unregulated office spaces ranged up to 1.1 mSv yr-!, which is similar to the 1 mSv yr-! threshold for regulation ofa 'radiological worker,' as defined in the Department of Energy regulations for occupational exposure. Additionally, the estimated average effective dose total of> 3 mSv yf! from radon background exposure in homes stands in contrast to the 0.1 mSv yr-! air pathway effective public dose limit regulated by the Environmental Protection Agency for radioactive air emissions.

61 RADIATION PROTECTION AND DOSIMETRY↗