Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

GADRAS Batch Inject Tool User Guide

Gamma Detector Response and Analysis Software (GADRAS) is used by the radiation detection and emergency response community to perform modeling and spectral analysis for gamma detector systems. Built into GADRAS is the ability to define a detector, geometry, background characteristics and source composition to generate synthetic spectra for drills and exercises (injects). Consequence Management is currently in development of a sample result data simulator tool in which a deposition model is probed for source conditions at moments in time and locations in space. These values are used to generate realistic sample results for use in drills and exercises. In addition to sample results, there is a need to simulate the actual spectra that would be observed in the field by downlooking HPGe instruments given a deposition activity. This way, the FRMAC Gamma Spectroscopist can practice their process of generating quantified results from spectra on realistic data as well. Recognizing the decades of work done in GADRAS to accurately generate synthetic spectra, this team decided to build a link between the new simulator and GADRAS to generate these spectra quickly and easily. The simulator tool will generate a file that specifies the name of the spectra, its location, date/time of measurement, duration of measurement, height off the ground, and the deposition activity and age for every radionuclide in the simulation. Then, a new tool within the Inject Tab of GADRAS was developed to read in this file given a detector selection and generate In-Situ spectra for each row in the file in any file format the user chooses. This way, simulation cell staff can take these files and then upload them to the appropriate data system (RAMS or RadResponder) for use during drills and exercises. An advanced feature of this tool allows for generating any spectra given an appropriate model and mapping of source to model layer in the batch inject tool. This way, spectra from field sample counts, mobile laboratories, or even fixed laboratories can be generated in bulk given an estimate of the radioactivity concentration or total radioactivity in an import file. This expands the capabilities of this tool a great deal and will make it a more useful tool for CM and others to help estimate detector response for nearly any situation. This user guide will explain the steps needed to perform a batch inject file generation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Minimum Detectable Quantity Calculation for Radiation Portal Monitors

The minimum detectable quantity of a radiation portal monitor is the smallest amount of radioactive material that can be detected passing through the monitor (with a specified detection probability). The minimum detectable quantity is a function of many factors, including isotope, velocity, distance between pillars, height of portal and vehicle, source distribution and position, background radiation, background suppression, detector volume and positions, detector efficiency, decision metrics and algorithms, the presence of NORM (naturally occurring radioactive material), and alarm thresholds. Experimentally testing a radiation portal monitor to failure for all combinations of these factors is extremely time-consuming and often cost prohibitive. This document outlines a straightforward method for quickly estimating the minimum detectable quantity for moving sources over a large variety of conditions with a minimal number of static measurements. The document also describes a proof of concept software application that the International Atomic Energy Agency has designed based on the described method that can be used by Member States to estimate a monitor’s minimum detectable quantity.

Blessinger, Christopher S.↗

Metal Halide Scintillators with Fast and Self‐Absorption‐Free Defect‐Bound Excitonic Radioluminescence for Dynamic X‐Ray Imaging

Abstract Scintillators for radiation detection are of great significance in medical imaging, security, and nondestructive inspection. The current challenge for scintillators is to simultaneously achieve high scintillation light yield, fast radioluminescence, simple film fabrication, large X‐ray attenuation efficiency as well as stable and nontoxic compositions; no previous scintillators fulfill all the above requirements. Here, metal halide Rb 2 AgBr 3 , possessing defect‐bound excitonic radioluminescence, is shown as efficient and fast scintillators. This nontoxic and stable scintillator emits from excitons bound to neutral bromine vacancies, enjoying an efficient and spin‐allowed fast emission with minimized self‐absorption. Rb 2 AgBr 3 thus has a high light yield (25 600 photons MeV −1 ), fast scintillation decay time (5.31 ns), and a record value of light yield versus decay time (4821 photons MeV −1 ns −1 ). The close‐space sublimation method is developed for fast and scalable fabrication of oriented Rb 2 AgBr 3 films. The scintillator film is further integrated with commercial flat‐panel imagers, and the spatial resolution reaches 10.2 line pairs per millimeter at the modulation transfer function of 0.2, doubling the resolution of conventional CsI:Tl flat‐panel detectors. The dynamic X‐ray imaging and its use to real‐time monitoring of bone movement without ghosting effect is also demonstrated.

Zhang, Muyi↗

Role of Selenium in CdZnTeSe as a Defect Engineering Agent

Cadmium zinc telluride (CdZnTe) with 10 atomic % Zn has been the material of choice for room-temperature semiconductor compact X- and gamma-ray detector applications for over three decades. Despite its commercial success as the most desirable room-temperature semiconductor radiation detection material, CdZnTe (CZT) suffers from a lack of compositional homogeneity on both the micro- and macroscales and the presence of high concentrations of performance-limiting defects such as subgrain boundary networks (dislocation walls) and secondary phases (Te-rich inclusions). Random distributions of these defects in the CZT matrix result in the spatial inhomogeneity of the material’s charge-transport properties. The recently discovered quaternary Cd x Zn 1-x Te 1-y Se y (CZTS) has experienced remarkable advances in its material properties, with highly reduced defects and higher compositional homogeneity. This book chapter focuses on the presence of performance-limiting defects in CZT that have thus far hindered the yield and cost of high-quality detectors and restricted their widespread deployment for a variety of potential applications, particularly for their use as large-volume gamma detectors, where the demands on material perfection are significantly greater. This chapter also provides an overview of the recent developments in the quaternary material CZTS, particularly the effects of selenium (Se) in the CZTS matrix on the defect engineering of the quaternary alloy material and the advancement of CZTS as a potential next-generation detector operable at room temperature.

Roy, Utpal N.↗

Effects of excess Te on flux inclusion formation in the growth of cadmium zinc telluride when forced melt convection is applied

The presence of second phase defects, particularly flux inclusions of tellurium rich composition, are of great concern for charge collection efficiency in cadmium zinc telluride (CZT) and cadmium telluride (CT) material intended for applications such as radiation detection. These inclusions can distort applied electric field lines within the detector as well as act as trapping centers for charge carriers. Reduction and/or elimination of these inclusions is required to achieve appropriate charge collection efficiencies, especially in detectors of thicknesses greater than 5 mm. These so-called flux inclusions are understood to form as a consequence of constitutional undercooling at the crystal growth interface. In this study, a forced melt convection technique was applied in Vertical Bridgman (VB) melt growth of CZT without reducing imposed growth rates of ~2 mm/hr. Several rotation profiles were tested while adjusting the melt composition from 51.62 to 61.75 atomic percent (at%) Te where the Te concentration was initially increased to improve overall material purity. With forced melt convection, the best inclusion distributions were achieved with highly Te rich melt compositions, far beyond the stoichiometric composition range for the CZT system. Average inclusion diameters were reduced to 2 µm while inclusions greater than 5 µm were essentially eliminated. Composition analyses of these ingots revealed near equilibrium concentrations of Te, even with ingots grown from Te concentrations as high as 61.75 at% Te. In this paper, a recipe for the reduction of inclusions in CZT melt growth is put forward and the implications of this method on our understanding of inclusion formation are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of simulated HPGe detector efficiencies in OpenMC compared to MCNP

In late 2023, the open-source radiation transport code OpenMC introduced a pulse-height tally (PHT) feature, enabling users to track the total energy deposited by individual photons in OpenMC cells. This function represents an important improvement of the OpenMC code because it allows users to simulate the response function of a gamma detector without relying on closed-source alternatives. Despite this, limited work has been published evaluating OpenMC as a radiation transport code for simulating gamma spectroscopy experiments. This study attempts to demonstrate the usefulness of OpenMC in this space by directly comparing its PHT output to MCNP (a trusted industry-standard Monte Carlo code). In the first half of this study, a radiation transport experiment is described in which a detector with a complex internal geometry is exposed to various gamma-emitting isotopes ( 133 Ba, 137 Cs, and 60 Co) over a range of distances. The setup of this experiment was modeled in MCNP with sufficient detail to capture the efficiency characteristics of a high purity germanium (HPGe) detector for the primary gammas of each isotope. After good agreement between the MCNP model and experiment was achieved, an identical model was produced in OpenMC to allow direct comparison between the full energy peak (FEP) values produced in OpenMC and MCNP. The results show strong agreement between OpenMC and MCNP across the full range of tested energies, with each model’s FEP values typically within 2% of each other and most FEP areas within 4% of experimental data. Worse agreement was seen between the Monte Carlo codes and experiment below 300 keV (an expected result). For the 662 keV line of 137 Cs, both codes were found in poor agreement with experiment and each other over the full range of distances tested (possibly indicating an error with the 137 Cs experimental data). Ignoring the anomalous results of the 662 keV line, all other data show good qualitative and quantitative agreement between MCNP and OpenMC. This result demonstrates the accuracy of OpenMC’s PHT feature for spectroscopic applications in which detector efficiency is a primary concern.

07 - ISOTOPES AND RADIATION SOURCES↗

Compound pulse characteristics of a heterogeneous composite scintillator in a gamma-ray field

An important aspect of radiation detection in scintillators is the time dependence of emitted fluorescence, which results in characteristic measured pulse shape. In some materials, a relatively strong dependence of the scintillation pulse shape on stopping power exists, which can provide reliable identification of the incident particle. An alternative method to realize particle identification is by combining materials with different fluorescence lifetimes into heterogeneous structures. Such composite scintillators derive their properties from both the constituent material characteristics and the geometry of the composite structure. In composite scintillators with a high degree of heterogeneous loading, a superposition of fluorescence contributions originating in multiple materials, which is observed as single waveform with an intermediate pulse shape, may affect its ability to reject rays. We measure the time dependence of light output from a scintillator composed of 6 Li-containing glass shards and scintillating polyvinyl toluene and identify events that exhibit such compound behavior when exposed to rays and fast neutrons. We develop a modeling and simulation framework that reproduces the pulse shapes in heterogeneous scintillators and use it study the effect that the weight percentage of 6 Li glass has on rejection. The modeling framework is applied to the experimentally studied scintillator, finding a good agreement. Here, the developed modeling and simulation approach will help optimize the design of heterogeneous scintillators to meet the desired trade-o between neutron capture efficiency and -ray rejection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of retroreflective tape optical properties for use with position-sensitive scintillator detectors

Reflective materials such as Teflon and Enhanced Specular Reflector are commonly used to maximize light collection in scintillator-based radiation detection systems. While effective, in most cases, the spatial information carried by the light is diminished or lost entirely. Retroreflectors, in contrast, better preserve the spatial information and have been shown to improve the localization performance of such systems. In this work, the relative retroreflectivity of a selection of commercial retroreflective tapes and their performance impact when coupled to a plastic scintillator are reported. Finally, we demonstrate improved localization performance with some tapes compared to Teflon and black paint.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Convolution-based frequency domain multiplexing of SiPM readouts using the $\mathrm{DRS4}$ digitizer

Here we present 4:1 multiplexing of organic scintillators, each coupled to a silicon photomultiplier (SiPM), to reduce the need for a large number of digitizer input channels to readout highly pixelated radiation detection systems. Frequency domain multiplexing (FDM) encodes a detector pulse by assigning it a unique frequency via convolution before combining the encoded signal into a single channel. The combined signal is then read through a digitizer input channel. We have designed an FDM system to multiplex four SiPMs using DRS4 digitizer evaluation board from Paul Scherrer Institute (PSI). We demonstrate 4:1 multiplexing of the SiPM fast output signals and pulse recovery from the digitized multiplexed signal using deconvolution. The noise in the recovered pulse introduces a bias and uncertainty in the estimate of energy and timing that changes with pulse height. The relative uncertainty in the estimated energy from the recovered pulse decreases with pulse height with a maximum uncertainty of 3.1% for the low energy pulses (corresponding to 100 keV); the uncertainty in the estimated time pick-off also decreases with pulse height with a maximum uncertainty of 110 ps for the low energy pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hole Trapping in Halide Perovskites Induces Phase Segregation

Metal halide perovskites have garnered a great deal of attention for their applications in photovoltaics, LEDs, and radiation detection. The ease of solution processing high-quality perovskite semiconductors with large absorption coefficients and tolerance to native defects is decidedly attractive. Additionally, the ability to precisely tune the band gap of halide perovskites through compositional alloying of the halide ion is of particular interest for a range of applications, especially for tandem solar cells. However, under steady state light irradiation, an initially homogeneous mixed halide perovskite (MHP) will form local domains that are rich in one halide ion (e.g., Br or I). This light-induced phase segregation in MHPs forms iodide-rich domains that act as charge carrier traps and lowers the efficiency of perovskite-based devices. Thus, phase segregation poses a serious challenge to the implementation of MHPs in real-world device settings. Interestingly, when a phase segregated MHP film is placed in the dark, entropic driving forces become dominant and the segregated perovskite remixes and returns to its initially homogeneous state. Several key mechanistic details of phase segregation have been elucidated over the years. However, there are still aspects of halide segregation that are not clear, and there is ongoing debate in the literature as to what are the key factors that contribute to the mechanism. This Account discusses recent results that point to the specific role of hole trapping in phase segregation. Interestingly, generation of holes through above-band-gap excitation or through electrochemical injection increases ion migration and leads to phase segregation. The thermodynamic and redox properties of halide perovskites provide a strong driving force for hole trapping and oxidation of iodide species in MHPs. However, mobile halide species within the perovskite lattice take time to migrate and generate halide-rich domains. When in contact with a nonpolar solvent, the migration of iodine species is further extended to expulsion of iodine from the perovskite film. Thus, the mobility of halides and their susceptibility to hole-induced oxidation play a crucial role in determining the long-term stability of metal halide perovskites. Strategies to gain kinetic control over ion migration to slow phase segregation are needed to overcome these hurdles and achieve stable mixed halide perovskites. Modification of the perovskite composition through introduction of different cations or halide ions, or introduction of low-dimensional perovskite phases may suppress phase segregation. Furthermore, in achieving stability and improving the efficiency of perovskite solar cells and light emitting devices with minimal impacts, suppression of segregation remains the key factor.

36 MATERIALS SCIENCE↗

K 2 CuX 3 (X = Cl, Br): All-Inorganic Lead-Free Blue Emitters with Near-Unity Photoluminescence Quantum Yield

Recently, copper(I) halides have been gaining increased attention as highly luminescent nontoxic alternatives to lead halide perovskites for optoelectronic applications. In this paper, we report preparation of blue emitting, lead free, all-inorganic halides K 2 CuX 3 (X = Cl, Br) through five synthetic methods including traditional solid-state and solution methods. The photoluminescence (PL) emission spectra of K 2 CuCl 3 and K 2 CuBr 3 exhibit narrow peaks centered at 392 and 388 nm with full widths at half-maximum (fwhm) values of ~54 nm. The visible bright blue emission is corroborated by the remarkably high photoluminescence quantum yield (PLQY) values up to ~97%. Furthermore, radioluminescence measurements on K 2 CuCl 3 yield a bright peak at 404 nm under irradiation with X-rays at 200 kVp and 20 mA, which is optimal for use with PMTs and Si photomultipliers, suggesting a strong potential of this family for radiation detection applications. Based on our combined experimental and computational investigations, the origin of the efficient luminescence in K 2 CuX 3 is attributed to the high stability self-trapped excitons (STE) formed in the one-dimensional anionic ∞ 1 [CuX 3 ] 2– chains. Advantageously, K 2 CuX 3 demonstrate improved air- and photostability compared to the previously reported copper(I) halides. The discovery of highly efficient and high stability light emitters based on earth-abundant copper(I) halides paves the way for their potential practical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of Quantum Dot Loading on the Radioluminescence Efficiency in Quantum-Dot-Embedded Composites

Nanoparticle-embedded plastic scintillators are an emerging technology for fast, large-area, high-resolution radiation detection and imaging. Here, this study investigates the properties of such composites, focusing on the effects of the quantum dot (QD) concentration on the radioluminescence (RL) intensity, spectra, and dynamics. Experiments using CdSe/CdS QDs in a polymer reveal a superlinear increase in RL with the QD concentration despite optical losses from inner filtering and interparticle interactions. When corrected for inner filtering, RL shows a quadratic concentration dependence, consistent with simple analytical models of improving the secondary electron capture. Practically, the benefits of high QD concentrations are muted by optical losses, but the findings apply to other systems with insulating hosts. In addition to manipulating emission for large effective Stokes shifts, future improvements may come from hosts with higher stopping power and better charge transport, which enable more effective funneling of excitations but without concomitant optical losses associated with high nanoparticle concentrations.

Auger recombination↗

Assessment of Blocking Contacts in Suppressing Polarization Effects in CsPbBr 3 Perovskite Detectors

The CsPbBr 3 perovskite has garnered significant attention as a room-temperature semiconductor for hard radiation detection due to straightforward synthesis, scalable crystal growth, low cost, and excellent energy resolution. However, despite these advantages, at ambient temperature, CsPbBr 3 devices may experience performance deterioration and irreversible failure due to “polarization” induced by electromigration of ions to electrical connections on the device. In this study, we tested several contact materials and their optimization deposition techniques to assess the stability of high-performance CsPbBr 3 γ-ray detectors. Metals, with low work functions (Ti, In, Sn, Sb, Pb, Bi, Al, Au, and TiC) and high-work-function (Au or Pt) contacts, were used to form different Schottky junctions using vacuum thermal evaporation, electron-beam evaporation, and sputtering methods. These detectors were tested in intermittent and continuous modes to assess their stability. Among the tested detectors, the Bi/CLB/Pt electrode configuration demonstrated superior stability, operating effectively for 11 months under periodic testing and 16 days under continuous testing. In contrast, other configurations functioned only for a few months under intermittent conditions. Upon incorporating a ~40-nm-thick TiC passivation layer on the anode side (Bi/TiC/CLB/Pt), the CLB device operated continuously for 36 days without degradation. In many cases, the failure mode of the devices was due to the degradation of the anode. Here, the chemical changes in the fresh and deteriorated anodes were characterized using scanning electron microscopy and energydispersive X-ray spectroscopy

CsPbBr3 perovskite↗

Optimized Photoemission from Organic Molecules in 2D Layered Halide Perovskites

In recent years, hybrid organic−inorganic metal halides have been at the forefront of materials research. Typically, the functional (e.g., optoelectronic) properties of hybrid halides are derived from the inorganic structural part, whereas the organic structural units can add extra advantages in terms of stability, rigidity, and processability. Here, we report the design, synthesis, and characterization of two new hybrid materials in which the outstanding photophysical properties originate from the organic structural part. The new compounds, (C 15 H 16 N) 2 CdCl 4 and ((Br)C 15 H 15 N) 2 CdCl 4 , have 2D layered Ruddlesden−Poppertype perovskite structures. These hybrids are blue-white light emitters just like their corresponding pure organic salts, but with much improved emission efficiencies. Optical spectroscopy and density functional theory (DFT) studies confirm that photoemission comes from the trans-stilbene organic cations. The photoluminescence quantum yield (PLQY) values of these new materials are among the highest known, 50.83% and 26.60% for (C 15 H 16 N) 2 CdCl 4 and ((Br)C 15 H 15 N) 2 CdCl 4 , respectively. This is up to a 5-fold increase as compared to the light emission efficiency of the precursor salt C 15 H 16 NCl (PLQY of 10.33%). Alongside their outstanding optical properties, their environmental and thermal stability allow their consideration for potential practical applications such as radiation detection. This work shows that hybrid metal halides can be compositionally and structurally engineered to have highly efficient photoemission originating from the organic components for fast scintillation applications.

Halogens↗

Tetris-inspired detector with neural network for radiation mapping

Abstract Radiation mapping has attracted widespread research attention and increased public concerns on environmental monitoring. Regarding materials and their configurations, radiation detectors have been developed to identify the position and strength of the radioactive sources. However, due to the complex mechanisms of radiation-matter interaction and data limitation, high-performance and low-cost radiation mapping is still challenging. Here, we present a radiation mapping framework using Tetris-inspired detector pixels. Applying inter-pixel padding for enhancing contrast between pixels and neural networks trained with Monte Carlo (MC) simulation data, a detector with as few as four pixels can achieve high-resolution directional prediction. A moving detector with Maximum a Posteriori (MAP) further achieved radiation position localization. Field testing with a simple detector has verified the capability of the MAP method for source localization. Our framework offers an avenue for high-quality radiation mapping with simple detector configurations and is anticipated to be deployed for real-world radiation detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CsPbBr3 perovskite detectors with 1.4% energy resolution for high-energy γ-rays

Halide perovskite semiconductors are poised to revitalize the field of ionizing radiation detection as they have done to solar photovoltaics. We show that all-inorganic perovskite CsPbBr 3 devices resolve 137 Cs 662-keV γ-rays with 1.4% energy resolution, as well as other X- and γ-rays with energies ranging from tens of keV to over 1 MeV in ambipolar sensing and unipolar hole-only sensing modes with crystal volumes of 6.65 mm 3 and 297 mm 3 , respectively. Furthermore, we report the scale-up of CsPbBr 3 ingots to up to 1.5 inches in diameter with an excellent hole mobility–lifetime product of 8 × 10 -3 cm 2 V -1 and a long hole lifetime of up to 296 μs. CsPbBr 3 detectors demonstrate a wide temperature region from ~2 °C to ~70 °C for stable operation. Detectors protected with suitable encapsulants show a uniform response for over 18 months. Consequently, we identify perovskite CsPbBr 3 semiconductor as an exceptional candidate for new-generation high-energy γ-ray detection.

47 OTHER INSTRUMENTATION↗

Devising novel methods for the controlled synthesis with morphology and size control of scintillator materials

Nanoscale scintillators represent an important class of materials underlying the functioning of high resolution, high ‘light yield’ radiation detection equipment, applicable for medicine in addition to security and environmental monitoring. This current study has focused on the controlled synthesis of Cs 2 ZnX 4 (X = Cl, Br) not only due to its very fast and promising radioluminescence decay time but also because no reliable synthesis protocols have been reported for producing nanoscale motifs of this material, to date. Solution-based methods can be used to synthesize products, possessing different, discrete morphologies with the ability to dictate particle size and shape. Specifically, we have demonstrated that a hot injection technique can be used to fabricate nanoscale rods and plates. Using this method, we systematically studied the effect of varying reaction variables, such as (i) reaction temperature, (ii) surfactants, and (iii) reaction time. As synthesized nanorods of Cs 2 ZnCl 4 possessed lengths of 101.3 ± 24.4 nm with widths of 17.3 ± 4.5 nm, whereas Cs 2 ZnBr 4 , created under identical conditions, were characterized by lengths of 206 ± 50 nm and widths of 26.7 ± 12.6 nm. Ligand-assisted re-precipitation (LARP) was used to produce the corresponding micron-sized particles. Under these conditions, we successfully synthesized spindles and spherical particles of Cs 2 ZnCl 4 with sizes of 1.58 ± 0.16 μm and 1.03 ± 0.34 μm, respectively, whereas plates of Cs 2 ZnBr 4 were prepared with average sizes of 0.76 ± 0.21 μm. High resolution synchrotron mapping, using the hard X-ray nanoprobe at NSLS II, was used to confirm the expected spatial distribution of Cs, Zn, and Cl within the as-produced crystals. Nanorods of Cs 2 ZnCl 4 and Cs 2 ZnBr 4 were subsequently tested for scintillation light yield and decay times. Preliminary results showed that Cs 2 ZnCl 4 maintained a light yield of 100–300 photons per MeV with a fast decay component of 2.6 ns. Finally, the Cs 2 ZnBr 4 analogue did not give rise to any perceptible scintillation emission.

36 MATERIALS SCIENCE↗