Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RUPTURES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Endovascular Management of Ruptured Abdominal Aortic Aneurysms: An 8-year Single-Centre Experience

We aimed to review our experience with the endovascular treatment of ruptured abdominal aortic aneurysm (RAAA). During an 8-year period, 69 patients with a RAAA presented to our department; 67 underwent assessment by computed axial tomography, and 2 died on arrival before any evaluation was possible. A total of 42 patients (63%) were suitable for stent-grafting, and all but 1 (c-arm failure) proceeded to endovascular repair. Of these, 27 underwent surgery with local anaesthesia; 3 did so under general anaesthesia; and a further 11 procedures were commenced with the patient under local anaesthesia and then converted to general anaesthesia. A total of 28 bifurcated and 14 aorto-uni-iliac stent-grafts were implanted. Aortic occlusion balloons were used in 2 (5%) patients. The in-hospital and the 30-day mortality rates were 36% and 41%, respectively. After surgery, 21 complications were encountered in 17 patients. Two patients required reintervention during their hospital stay (1 type I endoleak and 1 limb occlusion). During the follow-up (median 730 days [range 90 to 580 days]), the 1-year and 5-year cumulative survival probabilities were 53% (SE 7.9%) and 50% (SE 8.0%), respectively. Three reinterventions were necessary during follow-up (2 type I endoleaks and 1 graft occlusion). We conclude that endovascular treatment is feasible in the emergency setting, and the early experience is promising. Whether such an approach is superior to open surgery remains to be determined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Ruptured Abdominal Aneurysm into the Inferior Vena Cava in Patient After Stent Graft Placement

We report the case of a patient who underwent endovascular repair and then reintervention as a result of the presence of a persistent endoleak complicated by an aortocaval fistula. A 76-year-old patient with a history of endovascular treatment for abdominal aortic aneurysm 2 years earlier had a palpable abdominal mass, high-output cardiac failure, and renal failure. A computed tomographic scan and angiography revealed bending of the right iliac limb, a type I endoleak, and rupture of the aneurysm into the inferior vena cava with aortocaval fistula formation. An iliac extension was positioned in the right external iliac artery. The procedure was finished successfully. Control angiography showed normal flow within the endoprosthesis, and both iliac arteries were without signs of endoleakage and aortocaval fistula. Ectatic common iliac artery may lead to a late distal attachment site endoleak. The application of a stent graft in cases of secondary aortocaval fistula after stent graft repair is a good option, particularly in emergency cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emergency Endovascular Treatment of Sac Rupture for Type IIIa Endoleak in Thoracic Aortic Aneurysm Previously Excluded with Endovascular Repair

Elective endovascular treatment of thoracic aortic pathology has been applied in a variety of conditions. The complications of thoracic aortic stenting are also well recognized. Endoleak after endovascular repair of thoracic aortic aneurysms is the most frequent complication; among them, type III is the least frequent. Endovascular treatment of type III endoleak is generally performed under elective conditions; less frequently, in emergency. We report a successful emergency endovascular management of post-thoracic endovascular repair for thoracic aortic aneurysm rupture due to type IIIa endoleak.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Experience with Computed Tomography and Fluoroscopically Guided Placement of Push-Type Gastrostomy Tubes Using a Rupture-Free Balloon Catheter

The purpose of this study was to evaluate the safety and feasibility of percutaneous radiologic gastrostomy placement of push-type gastrostomy tubes using a rupture-free balloon (RFB) catheter under computed tomography (CT) and fluoroscopic guidance. A total of 35 patients (23 men and 12 women; age range 57-93 years [mean 71.7]) underwent percutaneous CT and fluoroscopically guided gastrostomy placement of a push-type gastrostomy tube using an RFB catheter between April 2005 and July 2008. Technical success, procedure duration, and complications were analyzed. Percutaneous radiologic gastrostomy placement was considered technically successful in all patients. The median procedure time was 39 {+-} 13 (SD) min (range 24-78). The average follow-up time interval was 103 days (range 7-812). No major complications related to the procedure were encountered. No tubes failed because of blockage, and neither tube dislodgement nor intraperitoneal leakage occurred during the follow-up period. The investigators conclude that percutaneous CT and fluoroscopically guided gastrostomy placement with push-type tubes using an RFB catheter is a safe and effective means of gastric feeding when performed by radiologists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ruptured Aortic Aneurysm From Late Type II Endoleak Treated by Transarterial Embolization

Endoleak is the most common complication after endovascular aneurysm repair. The most common type of endoleak, a type II endoleak, typically follows a benign course and is only treated when associated with increasing aneurysm size. In this case report, we describe a ruptured abdominal aortic aneurysm due to a late, type II endoleak occurring 10 years after endovascular aneurysm repair that was successfully treated by transarterial embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spontaneous Rupture of Superficial Femoral Artery Repaired with Endovascular Stent-Grafting with use of Rendez-Vous Technique, Followed by Delayed Infection

This is the case of a 72-year-old man with lower limb ischemia due to spontaneous rupture of nonaneurysmal superficial femoral artery that developed into thigh hematoma. After failure of a Fogarty revascularization, an emergency endovascular procedure was performed to restore the arterial continuity. A rendezvous procedure was performed with a double femoral and popliteal approach and two covered stent-grafts were deployed. Patient's clinical conditions immediately improved, but 4 months later the stent-grafts were surgically removed for infection and exteriorization. A femoropopliteal bypass was performed. After 1 year follow-up, the patient is in good clinical condition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Infectious or Noninfectious? Ruptured, Thrombosed Inflammatory Aortic Aneurysm with Spondylolysis

Osteolysis of vertebrae due to inflammatory aortic aneurysm is rarely observed. However, it is estimated that up to 10 % of infectious aneurysms coexist with bone tissue destruction, most commonly the vertebrae. Inflammatory aneurysms with no identified infection factor, along with infiltration of adjacent muscle and in particular extensive destruction of bone tissue have rarely been described in the literature. A case of inflammatory aneurysm with posterior wall rupture and inflammatory infiltration of the iliopsoas muscle and spine, together with extensive vertebral body destruction, is presented. The aneurysm was successfully treated with endovascular aneurysm repair EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interventional Radiology Management of a Ruptured Lumbar Artery Pseudoaneurysm after Cryoablation and Vertebroplasty of a Lumbar Metastasis

We describe the management of a complication (a lumbar artery pseudoaneurysm and its rupture) after combined procedure (cryoablation and vertebroplasty) on a lumbar (L2) metastasis from renal cell carcinoma. Review of the literature is also presented with discussion about the measures to be taken to prevent these types of complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intraabdominal Hemorrhage from Ruptured Ectopic Varices Treated by Antegrade Embolization via a Recanalized Paraumbilical Vein

A 49-year-old man with alcoholic liver cirrhosis was admitted to our hospital with abdominal pain. Contrast-enhanced CT demonstrated massive hemorrhagic ascites and ectopic varices fed by right colic and ileocolic veins. The varices were treated with selective embolization via a recanalized paraumbilical vein using N-butyl cyanoacrylate. Currently, no complications and rebleeding have occurred for 7 months. Antegrade embolization via a recanalized paraumbilical vein is feasible and less-invasive in a patient with massive ascites. Flow reduction may be effective for intraabdominal hemorrhage from ruptured ectopic varices. Level of Evidence: Level 5, case report.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Numerical Study of the Dynamic Strength of RBMK-1000 Stack with Fuel Channel Rupture

The strength of the stack in a RBMK-1000 reactor facility with a rupture of a fuel channel is studied. Local models of unirradiated and irradiated stack, comprising an assembly consisting of 81 columns, and a complete model of the original stack are developed to calculate the parameters of RBMK-1000 core degradation. Numerical studies of the nonstationary stress-strain state of the initial unirradiated stack and the stack degraded by irradiation one year after the repair-restorative work, which confirm the core strength to be adequate, are presented.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of Predictive Model for Accurate Rupture Time from Multi-Axial Creep in Alloy 709 with Physics-Based Simulations

A physics-based model is developed to predict multiaxial creep behavior in Alloy 709 (A709), an advanced austenitic stainless steel intended for high-temperature applications such as Sodium Fast Reactors (SFRs). Compared to conventional stainless steels like 316H, A709 offers superior high-temperature performance; however, comprehensive data on its multiaxial creep response remain limited. To address this gap, a crystal plasticity finite element (CPFE) framework is used to simulate the deformation and failure mechanisms of A709 under multiaxial loading conditions. The model incorporates an extended Hu-Cocks dislocation creep formulation that accounts for precipitation effects, along with the Sham–Needleman model to capture grain boundary cavitation-driven failure. These advanced constitutive models enable a detailed understanding of the interplay between microstructural evolution and macroscopic creep response. Furthermore, the study evaluates the predictive accuracy of various effective stress measures in estimating creep rupture life, leveraging simulated multiaxial creep data. The findings provide critical insights into the applicability of different stress measures for engineering design and life prediction of A709 components operating under complex loading conditions. This work contributes to improving the reliability of high-temperature structural components by advancing predictive modeling capabilities for advanced austenitic steels.

Alloy 709↗

Predicting the creep-rupture lifetime of a cast austenitic stainless steel using Larson-Miller and Wilshire parametric approaches

An experimental dataset of just over 100 creep tests of a cast austenitic stainless steel, CF8C-Plus, was analyzed by two temperature-compensated parametric models (Larson-Miller, Wilshire et al.) to predict long-term lifetimes as functions of temperature and stress. The dataset and associated regression analyses showed greater scatter than typically found in recent similar studies of wrought Ni-based alloys by the same two models and was attributed to the microstructural inhomogeneity of the cast stainless steel. Qualitatively, the Larson-Miller formalism showed greater lifetime prediction accuracy than the Wilshire approach, with the latter model's predictive ability being particularly degraded by the presence of two very significant outlier results. This observation suggests that the Larson-Miller approach is more robust when treating rupture-time datasets that show particularly wide experimental scatter. Despite the differences in the overall predictive ability, both models yielded similar predictions of the applied stress at which CF8C-Plus would have a creep-limited lifetime of 100,000 h when loaded below the yield point.

36 MATERIALS SCIENCE↗

Accident event progression, gaps, and key performance indicators for steam generator tube rupture events in water-cooled SMRs: A review

According to historical records of reactor-related incidents, a steam generator tube rupture (SGTR) is one of the most common occurrences at operating pressurized water reactors (PWRs). Such design-basis accidents (DBAs) could lead to a direct path for radionuclides to be released to the atmosphere via the safety and relief valves, making assessments of radionuclide discharge from operating nuclear power plants (NPPs) into the environment crucial for ensuring safety. In such analyses, the primary focus has been on the extent of radioactive release, not the potential damage to the core. Moreover, significant and timely intervention by operators is needed during the initial stages of SGTRs in order to avert overfilling of the SGs, as well as to restrict the dissemination of radioactive materials. Determining the event sequence and phases that occur during an SGTR incident in an advanced passive (e.g., AP1000) water-cooled nuclear reactor is crucial for implementing effective passive safety systems (PSSs) for a specific water-cooled small modular reactor (SMR) design. Here this study provides a comprehensive review of the accident event progression, associated physical phenomena, knowledge gaps, and key performance indicators that must be evaluated and assessed in thermal-hydraulics models, based on relevant test data, respectively.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Detrended fluctuation analysis of the magnetic and electric field variations that precede rupture

Magnetic field variations are detected before rupture in the form of 'spikes' of alternating sign. The distinction of these spikes from random noise is of major practical importance since it is easier to conduct magnetic field measurements than electric field ones. Applying detrended fluctuation analysis (DFA), these spikes look to be random at short time lags. On the other hand, long-range correlations prevail at time lags larger than the average time interval between consecutive spikes with a scaling exponent {alpha} around 0.9. In addition, DFA is applied to recent preseismic electric field variations in long duration (several hours to a couple of days) and reveals a scale invariant feature with an exponent {alpha}{approx_equal}1 over all scales available (around five orders of magnitude)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of significant data loss on identifying electric signals that precede rupture estimated by detrended fluctuation analysis in natural time

Electric field variations that appear before rupture have been recently studied by employing the detrended fluctuation analysis (DFA) to quantify their long-range temporal correlations. These studies revealed that seismic electric signal (SES) activities exhibit a scale invariant feature with an exponent {alpha}{sub DFA}{approx_equal}1 over all scales investigated (around five orders of magnitude). Here, we study what happens upon significant data loss, which is a question of primary practical importance, and show that the DFA applied to the natural time representation of the remaining data still reveals for SES activities an exponent close to 1.0, which markedly exceeds the exponent found in artificial (man-made) noises. This enables the identification of a SES activity with probability of 75% even after a significant (70%) data loss. The probability increases to 90% or larger for 50% data loss.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗