Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROOFS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Thermally anisotropic building envelope for thermal management: finite element model calibration using field evaluation data

The thermally anisotropic building envelope (TABE) is an active building envelope that redistributes thermal loads in response to weather conditions and building energy demand. Conductive layers throughout the TABE distribute low-grade heat among hydronic loops, altering heat flow direction and intensity. Finite element models of TABE roof and wall panels were developed and calibrated using field evaluation data. The calibration results showed that heat flux differences between the experimental data and finite element models averaged –0.42% and 3.57%, with a maximum mean square error of 1.78 and 3.96 for roof and wall panels, respectively. A reduction in heat flux from the environment to the building living space over the entire testing period (weeks in July/August) was found to be 85% for roof panels and 335% (load reversed) for wall panels. Finally, these results indicate TABE can effectively harness low-grade thermal energy sources to achieve high energy efficiency and promote demand-side management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Surface reflectance degradation by microbial communities

Building envelope, such as a roof, is the interface between a building structure and the environment. Understanding of the physics of microbial interactions with the building envelope is limited. In addition to the natural weathering, microorganisms and airborne particulate matter that attach to a cool roof tend to reduce the roof reflectance over time, compromising the energy efficiency advantages of the reflective coating designs. We applied microbial ecology analysis to identify the natural communities present on the exposed coatings and investigated the reduction kinetics of the surface reflectance upon the introduction of a defined mixture of both photoautotrophic and heterotrophic microorganisms representing the natural communities. The result are (1) reflectance degradation by microbial communities follows a first-order kinetic relationship and (2) more than 50% of degradation from the initial reflectance value can be caused by microbial species alone in much less time than 3 years required by the current standard ENERGY STAR® test methods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rooftop Solar Photovoltaic Technical Potential in the United States. A Detailed Assessment

How much energy could be generated if PV modules were installed on all of the suitable roof area in the nation? To answer this question, we first use GIS methods to process a lidar dataset and determine the amount of roof area that is suitable for PV deployment in 128 cities nationwide, containing 23% of U.S. buildings, and provide PV-generation results for a subset of those cities. We then extend the insights from that analysis to the entire continental United States. We develop two statistical models--one for small buildings and one for medium and large buildings--and populate them with geographic variables that correlate with rooftop's suitability for PV. We simulate the productivity of PV installed on the suitable roof area, and present the technical potential of PV on both small buildings and medium/large buildings for every state in the continental US. Within the 128 cities covered by lidar data, 83% of small buildings have a location suitable for a PV installation, but only 26% of the total rooftop area of small buildings is suitable for development. The sheer number of buildings in this class, however, gives small buildings the greatest technical potential. Small building rooftops could accommodate 731 GW of PV capacity and generate 926 TWh/year of PV energy, approximately 65% of rooftop PV's total technical potential. We conclude by summing the PV-generation results for all building sizes and therefore answering our original question, estimating that the total national technical potential of rooftop PV is 1,118 GW of installed capacity and 1,432 TWh of annual energy generation. This equates to 39% of total national electric-sector sales.

14 SOLAR ENERGY↗

Winnebago Tribe Solar Project

The strategy of the Solar Project was to reduce fuel use within two years by a roof mounted photovoltaic system. The police/fire building is completely powered by electricity. The renewable energy system we have selected has a power capacity of 23kW and the ability to export 44.3 MWh. We anticipate 32.55% kWh energy savings, an excess of the required 30% reduction, in the building’s total fuel use based on the most current 12 months of data (2012). The solar electric system is a grid-tie, ballast mounted on a flat roof over the police/fire station. The solar electric system includes 280 Watt modules for a nominal total of 22.80 kW. Approximately 84 modules are ballast mounted to the flat roof facing south.

14 SOLAR ENERGY↗

A Photovoltaic System Payback Calculator

The Roof Asset Management Program (RAMP) is a DOE NNSA initiative to manage roof repairs and replacement at NNSA facilities. In some cases, installation of a photovoltaic system on new roofs may be possible and desired for financial reasons and to meet federal renewable energy goals. One method to quantify the financial benefits of PV systems is the payback period, or the length of time required for a PV system to generate energy value equivalent to the system's cost. Sandia Laboratories created a simple spreadsheet-based solar energy valuation tool for use by RAMP personnel to quickly evaluate the estimated payback period of prospective or installed photovoltaic systems.

14 SOLAR ENERGY↗

Geotechnical Concerns of Bayou Choctaw Strategic Petroleum Reserve and Explanations

Geotechnical concerns arise due to the close proximity of the some of the caverns to each other (e.g., Caverns 15 and 17) or to the edge of the salt dome (e.g., Cavern 20). There are nine abandoned caverns, one of which collapsed (Cavern 7) in 1954 and another (Cavern 4) which is believed to be in a quasi-stable condition. This report provides explanations for these geotechnical concerns. The structural integrity of the pillar between BC-15 and 17 is examined. No salt fall is expected through 2045. However, the dilatant damaged area increases with time, especially, at the chimney area of BC-17. One drawdown leach for both caverns could be allowed if they are normally operated as a gallery, depressurized simultaneously. The possibility of a loss in integrity of BC-20 is examined in the salt between the dome edge and the cavern. The edge pillar is predicted to have experienced tensile stress since September 1999, but the small tensile stressed area is predicted to disappear in 2018 because BC-20 is filled fully with brine rather than oil since 2/7/2013. Even though BC-20 is no longer used as an SPR cavern, we need to continue monitoring the cavern integrity. BC-4 is also currently filled with brine and will not hold pressure at the wellhead. The cavern extends upward into the caprock and has no effective salt roof The results indicate that any sort of caprock roof collapse for BC-4 is not imminent but salt falls will likely occur from the near-roof portions of the cavern. The uncertainty due to salt falls illustrates the importance of continued monitoring of the area around BC-4 for behavior such as subsidence and tilt which may indicate a change in the cavern's integrity status.

02 PETROLEUM↗

B197 Structural Study (Final Report)

Building 197 is a single-story prefabricated metal building constructed in 1984 and 1985 on a flat site. The footprint of the building is 150’-0” by 75’-0” (11,250 square feet). Various modifications to the roof framing and roof top equipment supports have been made since the original construction. The general scope of the project is to determine the dead and live load capacity of the existing roof framing, verifying new loads can be accommodated, and designing strengthening measures where needed to support new loads.

42 ENGINEERING↗

Life Cycle Assessment of Future Photovoltaic Electricity Production from Residential-scale Systems Operated in Europe

The photovoltaics (PV) industry is growing rapidly to meet the increasing demand of green power. As the industry grows, the manufacturing processes and the material and energy efficiencies of PV cells and panels are improving. To assess the impacts of this trend, future scenarios of single-crystalline (single-Si, also known as mono-crystalline) silicon and cadmium-telluride (CdTe) PV systems installed on European residences were established. Assessment of the improvement potential of PV electricity-generating technologies such as single-Si and CdTe could be considered in long-term energy strategy decisions. This study aims to provide scenario-based information about the environmental per-formance of single-Si and CdTe PV modules produced and operated in the far future (2030 to 2050). The deployment application assessed considers European residential roofs. We made scenario-dependent projections of key parameters for single-Si and CdTe PV panels manufactured in 2050. The parameters included cell efficiency, module efficiency, wafer thickness, cutting losses, kerf losses, silver use, glass thickness and operational lifetime. This study combines developments for these parameters with projections of the environmental performance of electricity mixes in the main manufacturing countries/regions (European Union, China and the United States of America) and with projections of the environ-mental performance of basic material production (aluminium, copper, magnesium, nickel, pig iron, zinc, clinker and flat glass) in the far future. The three scenarios used in the assessment of future PV electricity were categorized into three classes: 'business as usual' (BAU), 'realistic improvement' (REAL) and 'optimistic improvement' (OPT). It estimates the current life cycle greenhouse gas emissions of single-Si PV electricity produced on the roofs of European residences to be approximately 80 grams CO2-equi-valent per kWh (g CO2-eq per kWh). Based on the projected changes to key parameters and the background system, life cycle greenhouse gas (GHG) emissions could be reduced to 65% (scenario BAU), 31% (scenario REAL) and 18% (scenario OPT) of that value in the far future. Results for other life cycle assessment (LCA) metrics are also assessed in this study such as: non-renewable cumulative energy demand, acidification potential, human toxicity potential, photochemical ozone creation potential, particulate matter formation potential, and land use. We calculated the total energy payback time (EPBT) and the non-renewable energy payback time (NREPBT) in the far future of single-crystalline silicon-based PV panels operated in Europe by dividing the estimate of non-renewable cumulative energy demand of PV electricity for the given scenario by the non-renewable cumulative energy demand of the scenario-dependent national and regional non-renewable residual electricity mixes. The study estimates the payback time could be reduced from 2.4 years today to 1.7, 1.2 and 1.2 years (scenarios BAU, REAL and OPT, respectively) in the far future, based on the assumptions and projections in the analysis. It finally estimates the current life cycle greenhouse gas emissions of CdTe PV electricity produced on the roofs of European residences to be approximately 30 g CO2-eq per kWh. Based on the projected changes to key parameters and the background system, life cycle GHG emissions could be reduced to 70% (scenario BAU), 44% (scenario REAL) and 32% (scenario OPT) of that value in the far future.

14 SOLAR ENERGY↗

Infiltration Data Package for the E-Area Low-Level Waste Facility Performance Assessment

The infiltration data package contains the input parameters, the cap design and material properties assumptions, and the modeling results for the Hydrologic Evaluation of Landfill Performance (HELP) infiltration model simulations performed in support of the E-Area Low-Level Waste Facility Performance Assessment (PA). The infiltration estimates establish the upper boundary condition for the PORFLOW vadose-zone model and GoldSim model simulations for the following E-Area disposal unit types: Slit and Engineered Trenches, Low-Activity Waste Vault (LAWV), Intermediate-Level Vault (ILV), Componentin- Grout (CIG) special waste form trench segments, and the Naval Reactor Component Disposal Areas (NRCDAs). The infiltration data package builds upon relevant, foundational PA technical reports and memoranda from the past 15 years and is supported by three important components: the HELP model input parameter datasheets, HELP model input and output filenames and directory structure, and infiltration rates as a function of time for each scenario for each disposal unit type. For Slit and Engineered Trenches, a single best-estimate Bahia-grass case of two-percent slope and 585- foot slope length represents an upper bound on intact closure-cap infiltration rates over a 10,000-year period. Building upon the single, bounding, and intact case, two different approaches were considered for incorporating the effect of localized cap subsidence on infiltration rates in the PORFLOW flow and transport model simulations. In the first approach, a Monte Carlo probabilistic model was developed to calculate infiltration rates for 0.54%, 2%, 3.6%, and 4.9% subsidence scenariosa reflecting historical and future non-crushable content for the Slit and Engineered Trenches. The resulting blended (spatially and slope-length averaged) infiltration rates become an inflow upper boundary condition for the PORFLOW vadose zone model simulations. In the second and preferred approach, a Monte Carlo rectangle packing algorithm (Danielson, 2019) and a simplified equation for the total mass flux of water draining into a subsided compartment (Equation 1) will be employed to implement a weighted blending of radionuclide fluxes to the water table using the results of deterministic PORFLOW vadose zone simulations representative of specific subsidence cases. Finally, HELP-model results from sensitivity studies of the intact infiltration case were fit to a log-logistic function to generate infiltration profiles over a 10,000-year period for most-optimistic, more-optimistic, best-estimate, more-pessimistic, and most-pessimistic cases, for both the intact and four subsidence scenarios. For the LAWV and IL vaults, infiltration rate profiles for a 10,000-year period were developed for both an on-vault (above the concrete/metal vault roof) and an off-vault (10-foot soil zone adjacent to vault walls) scenario. The purpose of the off-vault simulations was to confirm that subsurface runoff from the concrete vault roof will adequately drain through the lowermost backfill layers adjacent to the vault walls. The LAWV and ILV infiltration profiles assume collapse of the concrete roof at relative Years 2,905 and 7,100, respectively. The identical Bahia-grass case with two-percent slope and 585-foot slope length assumed for the Slit and Engineered Trenches will represent an upper bound on intact infiltration rates for the NRCDAs and CIG special waste form as well. While the NRCDA casks are assumed to remain structurally intact (i.e., non-assumed to collapse 300 years after the end of operations. Because both rows of the existing CIG trench segments in ST23 (formerly CIG01) extend across the planned cap crest, the subsided CIG trench segments are treated conservatively in the HELP model as a 100%-subsidence case with zero subsurface run-on. The CIG special waste form trench segment infiltration profile, therefore, consists of an intact-cap period from relative Year 100 to Year 300, followed by a 100%-subsidence period from relative Year 300 to Year 10,100.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solar Energy Demonstration Project for Public Libraries

In this project, the South Hero Library Foundation purchased and installed a 39.95 kW DC roof-mounted solar array on the south-facing roof of the Worthen Library as well as on the south-facing roof of the neighboring 54 Community Lane building. This 94 panel array has a projected output of 39,950 kWh of power which will cover the Library’s annual power usage for heat and lighting. Any power overage will be distributed to other local organizations as designated by the Library. Library programming and added resources will be available to all patrons.

14 SOLAR ENERGY↗

A field study setup of four homes having non-ventilated and semi-conditioned sealed attics

During the 2015-2016 fiscal year and with financial support from the Florida Building Commission (FBC) and the Florida Roofing and Sheet Metal Contractors Association (FRSA ), the University of Florida (UF) and the Oak Ridge National Laboratory (ORNL) completed Phase I of a study that setup four residential home demonstrations in Florida climate zones CZ-1A and CZ-2A. UF and ORNL are evaluating the hygrothermal (heat and moisture flow) performance and durability of sealed attic construction where expanded foam insulation is applied directly to the underside of the roof deck. The four homes are instrumented for measuring temperature and relative humidity of the indoor living space, the outdoor air and the attic air. In addition, the temperature, relative humidity and moisture content of the roof sheathing are being monitored and recorded by remotely-accessible data acquisition equipment. Here, air leakage tests on the whole house, on the sealed attic and in the HVAC ducts were conducted on all four homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Study of application of ERTS-A imagery to fracture-related mine safety hazards in the coal mining industry

The author has identified the following significant results. The Kings Station Mine in Gibson County, Indiana has experienced considerable roof fall problems. Detailed fracture mapping of the mine area was done with ERTS-1 and aircraft imagery, and a prediction map of roof problem areas was produced in advance of a visit. The visit to the mine and discussions with the operator indicated that of four zones mapped as potential problem areas, three coincided with areas of excessive roof fall. This positive correlation of 75% lends confidence to the validity of the technique being applied in the investigation. The mine officials expressed an interest in the project and are anxious to see the final product maps which are forthcoming.

Wier, C. E.↗

Geometry effects on STOL engine-over-the-wing acoustics with 5.1 slot nozzles

The correspondence of far field acoustic trends with changes in the characteristics of the flow field at the wing trailing edge caused by alterations in the nozzle-wing geometry were determined for several STOL-OTW configurations. Nozzle roof angles of 10 to 40 deg were tested with and without cutback of the nozzle sidewalls. Three wing chord sizes were used: baseline (33 cm with flaps retracted), 2/3-baseline, and 3/2-baseline. Flap deflection angles of 20 and 60 deg were used. The nozzle locations were at 21 and 46-percent of chord. With increasing wing size the jet noise shielding benefits increased. With increasing nozzle roof angle, the jet velocity at the trailing edge was decreased, causing a decrease in trailing-edge and fluctuating lift noise. Cutback of the nozzle sides improved flow attachment and reduced far-field noise. The best flow attachment and least trailing-edge noise generally were obtained with a 40 deg external deflector configuration and a cutback nozzle with a 40 deg roof angle.

Vonglahn, U.↗

Geometry effects on STOL engine-over-the-wing acoustics with 5:1 slot nozzles

The correspondence of far field acoustic trend with changes in the characteristics of the flow field at the wing trailing edge caused by alterations in the nozzle-wing geometry were determined at model scale with a 5:1 slot nozzle for several STOL-OTW configurations. Nozzle roof angles of 10 to 40 deg were tested with and without cutback of the nozzle sidewalls. With increasing wing size, representing several airframe/engine installations, the jet noise shielding benefits increased. With increasing nozzle roof angle, the jet velocity at the trailing edge was decreased, causing a decrease in trailing-edge and fluctuating lift noise. Cutback of the nozzle sides improved flow attachment and reduced far-field noise. The best flow attachment and least trailing-edge noise generally were obtained with a 40-deg external deflector configuration and a cutback nozzle with a 40-deg roof angle.

Von Glahn, U.↗

Solar cell shingle

A solar cell shingle was made of an array of solar cells on a lower portion of a substantially rectangular shingle substrate made of fiberglass cloth or the like. The solar cells may be encapsulated in flourinated ethylene propylene or some other weatherproof translucent or transparent encapsulant to form a combined electrical module and a roof shingle. The interconnected solar cells were connected to connectors at the edge of the substrate through a connection to a common electrical bus or busses. An overlap area was arranged to receive the overlap of a cooperating similar shingle so that the cell portion of the cooperating shingle may overlie the overlap area of the roof shingle. Accordingly, the same shingle serves the double function of an ordinary roof shingle which may be applied in the usual way and an array of cooperating solar cells from which electrical energy may be collected.

Forestieri, A. F.↗

Finding and utilizing lunar lava tubes

Horz describes the evidence for lava tubes associated with rills in lunar photoimaging. These tubes have terrestrial counterparts as described by Billings, et al., and Gillet. The widths of these tubes range from 10s to 100s of meters. Their roof thickness are at least 0.125 to 0.25 times their widths and stand unsupported on the Moon. To confine one atmosphere of internal pressure, static roof thickness must be at least 16 m. Favorable locations of lava tubes may be surveyed using roving gravity meters on Doodle Bugs, which consist of platforms containing equipment for communication with Earth-based control stations. The stable -20 C temperature of the lava tubes should provide a workable habitat environment. The greater than 16 m of basalt in the roof should give adequate radiation and impact protection. Typically, after clearing entries and grading ramps, habitats might be placed in tubes and inflated. Later, larger habitats might be built by enclosing tube sections with compacted-regolith dams. The interior can then be sealed to hold an atmosphere. The huge lava tubes inferred from the photographs are capable of providing habitats hundreds of meters wide, in lengths of kilometers.

Kuck, David L.↗

Radiation Insulation

An aluminized polymer film is a highly effective radiation barrier for both manned and unmanned spacecraft. Variations of this space-devised material are also used as an energy conservation technique for homes and offices. One commercial company, Tech 2000 (formerly Buckeye Radiant Barrier), markets 'Super R' Radiant Barrier, which finds its origins in the Apollo Mission programs. The material is placed between wall studs and exterior facing before siding or in new roof installation, between roof support and roof sheathing. Successful retrofit installations have included schools and shrink wrap ovens. The radiant barrier blocks 95 percent of radiant energy, thus retaining summer heat and blocking winter cold. Suppliers claim utility bill reductions of 20 percent or more.

Source record↗