Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Recent Advances of PyROS: A Pyomo Solver for Nonconvex Two-Stage Robust Optimization in Process Systems Engineering

The document presents recent algorithmic and implementation advances of the two-stage robust optimization (RO) solver PyROS, and a benchmarking study which demonstrates the utility of PyROS for two-stage RO problems. The advances include extensions of the scope of PyROS to models with uncertain variable bounds, improvements to the initializations of the subproblems used by the underlying cutting set algorithm, and extensions of the uncertainty set interfaces. The benchmarking study is performed on a library of over 8,500 instances, with variations in the nonlinearities, degree-of-freedom partitioning, uncertainty sets, and polynomial decision rule approximations. An amine-based CO2 capture case study is presented to demonstrate the utility of PyROS for large-scale process models. Overall, the results highlight the effectiveness of PyROS for obtaining robust solutions to optimization problems with uncertain equality constraints.

Sherman, Jason↗

SWITCHABLE POLARITY SOLVENTS AS DRAW SOLUTES FOR FORWARD OSMOSIS

Switchable polarity solvents (SPS), mixtures of carbon dioxide, water, and tertiary amines, are presented as viable forward osmosis (FO) draw solutes allowing a novel SPS FO process. In this study substantial osmotic strengths of SPS are measured with freezing point osmometry and were demonstrated to induce competitive ?uxes at high salt concentrations on a laboratory-scale FO unit utilizing a ?at sheet cellulose triacetate (CTA) membrane. Under the experimental conditions the SPS degrades the CTA membrane; however experiments with polyamide reverse osmosis (RO) membranes display stability towards SPS. Once the draw is diluted the major fraction of the switchable polarity solvent can be mechanically separated from the puri?ed water after polar to nonpolar phase shift induced by introduction of 1 atm carbon dioxide to 1 atm of air or nitrogen with mild heating. Trace amounts of SPS can be removed from the separated water with RO in a process that avoids solution concentration polarization. The separated nonpolar phase can be regenerated to a full strength draw and recycled with the re-addition of 1 atm of carbon dioxide.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improvement of General Electric’s Chilled Ammonia Process with the use of Membrane Technology

General Electric Environmental Control Solutions (formerly Alstom Power Environmental Control Systems) set out to complete the Phase 1 award requirements for a Phase II renewal application for their project selected under DOE-FOA-0001190 “Small and Large Scale Pilots for Reducing the Cost of CO 2 Capture and Compression”. The project focus was to implement several improvement concepts utilizing membrane technology at the recipient’s Chilled Ammonia Process (CAP) CO 2 capture large-scale pilot plant. The goal was to lower the overall cost of technology. During the development of costs for the preliminary techno-economic assessment (TEA), it became clear that the capital and operating costs of this concept were not economically attractive. All work related to a Phase II renewal application at that point was halted as GE made the decision not to submit a Phase II renewal application. Discussions with DOE resulted in a path towards useful information produced from the design and cost work already completed on the project. With the reverse osmosis (RO) unit providing most of the cost issues, GE would provide a sensitivity analysis of the RO unit with respect to project cost. This information would be included with the Techno-Economic Analysis along with the Technology Gap Analysis.

20 FOSSIL-FUELED POWER PLANTS↗

Model-based Extracted Water Desalination System for Carbon Sequestration

The focus of this research effort centered around water recovery from high Total Dissolved Solids (TDS) extracted waters (180,000 mg/L) using a combination of water recovery (partial desalination) technologies. The research goals of this project were as follows: 1. Define the scope and test location for pilot-scale implementation of the desalination system, 2.Define a scalable, multi-stage extracted water desalination system that yields clean water, concentrated brine, and, salt from saline brines, and 3. Validate overall system performance with field-sourced water using GE pre-pilot lab facilities. Conventional falling film-mechanical vapor recompression (FF-MVR) technology was established as a baseline desalination process. A quality function deployment (QFD) method was used to compare alternate high TDS desalination technologies to the base case FF-MVR technology, including but not limited to: membrane distillation (MD), forward osmosis (FO), and high pressure reverse osmosis (HPRO). Technoeconomic analysis of high pressure reverse osmosis (HPRO) was performed comparing the following two cases: 1. a hybrid seawater RO (SWRO) plus HPRO system and 2. 2x standard seawater RO system, to achieve the same total pure water recovery rate. Pre-pilot-scale tests were conducted using field production water to validate key process steps for extracted water pretreatment. Approximately 5,000 gallons of field produced water was processed through, microfiltration, ultrafiltration, and steam regenerable sorbent operations. Improvements in membrane materials of construction were considered as necessary next steps to achieving further improvement in element performance at high pressure. Several modifications showed promising results in their ability to withstand close to 5,000 PSI without gross failure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Membrane Distillation Technology Utilizing Waste Heat for Treatment of High Salinity Wastewaters

Membrane distillation (MD) can serve as a cost effective method to treat high salinity wastewaters, especially if waste heat is utilized for its operation. The goal of this work is to study the feasibility of employing MD technology for the treatment of high salinity wastewaters which are generated as a result of natural gas production and active reservoir management for CO 2 sequestration. This study also aimed at quantifying the availability of waste heat which could be used as the primary source of thermal energy to drive the MD process. Bench scale studies were carried out with several commercially available membranes using both synthetic and actual high salinity wastewaters. The membranes tested with real wastewater samples exhibited excellent rejection of dissolved ions, including naturally occurring radioactive material (NORM). Long term bench scale experiments with real produced water from the Marcellus shale play revealed that iron oxide could precipitate on the feed side of direct contact MD (DCMD) module but had a negligible effect on the performance of the system. Based on the bench scale experiments, an ASPEN Plus simulation, which incorporated a mathematical model with fundamental heat and mass transfer equations, was developed and used to evaluate the process energy requirements. Despite low operating temperature and pressure for MD, it had a large thermal energy requirement for operation, which could make this technology expensive compared to reverse osmosis (RO) and forward osmosis (FO). However, it is important to note that RO and FO have limited applicability for high salinity shale gas wastewater. Moreover, MD could be integrated with renewable energy sources such as wind or solar energy or industrial waste heat sources to offset the thermal energy requirements and enhance the economics of wastewater treatment. Natural gas compressor stations (NG CS) have been proposed in this study as the source of waste heat based on the estimate of quantity and quality of available waste heat in the exhaust streams of gas turbine and internal combustion compressor engines. Using the actual installed capacity and location of compressor stations in the U.S., this analysis revealed that an average of 610 TJ/day of thermal energy is available at existing NG CS and that this source of waste heat is of high quality with temperatures above 645 K. A systems-level integration of MD with waste heat from NG CS revealed that approximately 56% of available waste heat at NG CS in Pennsylvania is sufficient to concentrate (from 10% to 30% salinity) all wastewater associated with shale gas extraction. Techno-economic assessment (TEA) accounting for capital as well as operating and maintenance costs with and without waste heat integration was conducted for a hypothetical 0.5 million gallons per day (MGD) DCMD plant using experimental and modeling results from this study. TEA revealed that the total cost of shale gas wastewater treatment using MD is $5.7/m 3 feed for the base case scenario in which the thermal energy requirements are met by external steam, however, the total cost can be reduced to $0.74/m 3 feed when integrated with free waste heat from NG CS. Sensitivity analysis revealed that thermal energy cost and feed TDS are the most important factors in total cost of high salinity wastewater treatment using DCMD.

03 NATURAL GAS↗

Simulation of Reverse Osmosis Membrane Compaction Using Material Point Method

Reverse Osmosis (RO) is a promising technology to address the impending water-crisis in the upcoming decades. RO at high salinities and high pressures is challenging due to membrane compaction that changes its porosity and permeability. In this study, we present a simulation methodology for membrane structural mechanics to understand pore size distribution and permeability variations under high pressure. We use the material point method (MPM), that solves the solid mechanics equations in a Lagrangian framework. MPM provides many features that make it well-suited for simulating mesoporous membranes. The Lagrangian framework allows for large deformations, easy integration of constitutive models and direct import of complex geometries as particles. The spatial discretization in our MPM solver is achieved using linear or cubic-spline shape functions while the time integration is carried out using the explicit Euler method. A series of images containing detailed pore structures obtained from X-ray tomography is first converted to a collection of material points. Compressive loads are applied to the top layer of the membrane to simulate the application of pressure. The membrane deformation and pore size distribution before and after load application are reported and compared with the experimental measurements. The presentation discusses the numerical methods used, the performance of the solver on high-performance computing machines, and the results of membrane compact in detail.

compaction↗

A Remote Absorption Process for Disposal of Evaporate and Reverse Osmosis Concentrates

Many commercial nuclear plants and DOE facilities generate secondary waste streams consisting of evaporator bottoms and reverse osmosis (RO) concentrate. Since liquids are not permitted in disposal facilities, these waste streams must be converted to dry solids, either by evaporation to dried solids or by solidification to liquid-free solids. Evaporation of the liquid wastes reduces their volume, but requires costly energy and capital equipment. In some cases, concentration of the contaminants during drying can cause the waste to exceed Class A waste for nuclear utilities or exceed DOE transuranic limits. This means that disposal costs will be increased, or that, when the Barnwell, SC disposal site closes to waste outside of the Atlantic Compact in July 2008, the waste will be precluded from disposal for the foreseeable future). Solidification with cement agents requires less energy and equipment than drying, but results in a volume increase of 50-100%. The doubling or tripling of waste weight, along with the increased volume, sharply increases shipping and disposal costs. Confronted with these unattractive alternatives, Diversified Technologies Services (DTS), in conjunction with selected nuclear utilities and D and D operations at Rocky Flats, undertook an exploratory effort to convert this liquid wastewater to a solid without using cement. This would avoid the bulking effect of cement, and permit the waste to be disposed of the Energy Solutions facility in Utah as well as some DOE facilities. To address the need for an attractive alternative to drying and cement solidification, a test program was developed using a polymer absorbent media to convert the concentrate streams to a liquid-free waste form that meets the waste acceptance criteria of the pertinent burial sites. Two approaches for mixing the polymer with the liquid were tested: mechanical mixing and in-situ incorporation. As part of this test program, a process control program (PCP) was developed that is 100% scalable from a concentrate test sample as small as 50 grams to full-scale processing of 100 cubic foot containers or larger. In summary: The absorption process offers utilities a viable and less costly alternative to on-site drying or solidification of concentrates. The absorption process can be completed by site personnel or by a vendor as a turnkey service. The process is suitable for multiple types of waste, including RO and evaporator concentrates, sludges, and other difficult to process waters and wet solids. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New Standards in Liquid Waste Treatment at Fukushima Dai-ichi - 13134

The earthquake and tsunami on March 11, 2011 severely damaged the Fukushima Dai-ichi nuclear plant leading to the most severe nuclear incident since Chernobyl. Ongoing operations to cool the damaged reactors at the site have led to the generation of highly radioactive coolant water. This is currently mainly treated to remove Cs-137 and Cs-134 and passed through a reverse osmosis (RO) unit to reduce the salinity before being cycled back to the reactors. Because only the Cs isotopes are removed, the RO reject water still contains many radioactive isotopes and this has led to the accumulation of over 200,000 cubic meters (52 million gallons) of extremely contaminated water which is currently stored on site in tanks. EnergySolutions, in partnership with Toshiba, were contracted to develop a system to reduce 62 isotopes in this waste down to allowable levels. This was a significant technical challenge given the high background salt content of the wastewater, the variation in aqueous chemistry of the radioactive isotopes and the presence of non-active competing ions (e.g. Ca and Mg) which inhibit the removal of isotopes such as Sr-89 and Sr-90. Extensive testing was performed to design a suitable system that could meet the required decontamination goals. These tests were performed over a 6 month period at facilities available in the nearby Fukushima Dai-ni laboratory using actual waste samples. This data was then utilized to design a Multi Radioactive Nuclides Removal System (MRRS) for Fukushima which is a modified version of EnergySolutions' proprietary Advanced Liquid Processing System (ALPS)'. The stored tank waste is fed into a preliminary precipitation system where iron flocculation is performed to remove a number of isotopes, including Sb-125, Ru-106, Mn-54 and Co-60. The supernatant is then fed into a second precipitation tank where the pH is adjusted and the bulk of the Mg, Ca and Sr precipitated out as carbonates and hydroxides. After passing through a cross-flow ultrafiltration membrane, the permeate then goes through a total of 14 fixed ion exchange and adsorbent columns followed by a disposable polishing column to polish the residual isotopes down to allowable levels. At the end of the system, the effluent is filtered for a final time to removal any particulates that may have been picked up from the media columns and then stored prior to analysis. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Innovations in Sustainable Passive Wastewater Treatment - 20236

Sustainable water treatment systems, engineered to mimic natural processes and utilize natural materials, yield economic and environmental benefits through reductions in long term operational inputs, including: power, chemicals, and labor. Golder is an industry leader in the development and implementation of sustainable technologies at operating and closed mines. We continue to innovate these technologies and customize solutions to meet client needs by applying past experience and focused research. Sustainable (or passive) water treatment systems include ponds, wetlands, flow-through natural media beds, and limestone drains. These systems can blend in with a natural environment, are highly cost-effective for long-term water treatment, and can outcompete traditional active treatment technologies. Application of sustainable technologies relative to active technologies can be influenced by the influent water matrix, effluent limitations, flow rate of water requiring treatment, and available land area. In this presentation, four Golder-developed systems are reviewed as case studies, demonstrating our continued progressive approach to advancing sustainable water treatment technologies to meet industry needs. These case studies focus on design innovations and operational performance from data collected from the operational systems. Resources (power, chemicals, labor) required for the operation of each case study are compared with those that would be required for operation of their active treatment technology alternatives. - Case Study 1 presents an anaerobic biochemical reactor (BCR), a technology typically implemented for metals treatment and acid neutralization, for the treatment of sulfate to low concentrations (<250 mg/L). Active treatment via reverse osmosis (RO) membrane filtration is typically required for treatment of sulfate to similar concentrations, this innovation provides potential for sustainable treatment to replace the need for energy, chemical, labor, and waste (brine) intensive RO treatment for specific applications. Magnetite waste rock materials from the site were upcycled for use in this system to provide sequestration of the sulfide generated in the BCR. - Case Study 2 examines another novel application of the conventional BCR, modified for the removal of radionuclides and metals (uranium, radium, and selenium) at a closed uranium mine. - Case Study 3 presents implementation of sustainable treatment for mine drain water from a historic mine site, now a state park with around 100,000 visitors per year. The system includes a pond, wetland, and manganese removal bed surrounded by public trails designed to maintain the character of the park. The system treats for arsenic, iron, and manganese at relatively high flows (up to 1,200 gpm), with large seasonal fluctuations in flow and quality. - Case Study 4 is a unique project for which Golder is currently designing a sustainable treatment system, with no energy input, to treat nitrate in mine water post-closure at a site near the arctic circle. In this unprecedented application, climate, management of freshet, and space availability presented substantial technical challenges. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Programa de Diseno, Fabricacion y Pruebas del Sistema de Desalinizacion por Olas del NREL: Preprint (Spanish Translation)

To de-risk the U.S. Department of Energy's Waves to Water Prize, the National Renewable Energy Laboratory (NREL) developed a modular, wave powered desalination system. The prize was open to wave energy converter (WEC) designs that generate electricity or WECs that desalinate water mechanically. This added installation risks due to the variance in competitor devices, and the aggressive installation timeline. To reduce these risks NREL developed a wave energy converter (WEC) that the installation team could use to practice installation techniques prior to the competitors arriving to ensure all steps had been considered prior to the event. This was achieved by developing a WEC with a modular power-take-off (PTO). The modular PTO can be configured in one configuration to drive an electric generator that sends electricity to a pier. The electricity that is generated is converted, and stored, so that it can be used to power an electric pump that feeds water to a Reverse Osmosis (RO) desalination unit. In the other configuration the generator is replaced with a pump and seawater is pumped to the RO system on the pier without any electrons being generated. This WEC is formally known as the Hydraulic and Electric Reverse Osmosis (HERO) WEC. For the English version of this report, see NREL/CP-5700-86623 (https://www.nrel.gov/docs/fy24osti/86623.pdf).

laboratory testing↗

Recent Advances in PyROS: The Pyomo Solver for Two-Stage Nonconvex Robust Optimization

The slides present recent algorithmic and implementation advances of the two-stage robust optimization (RO) solver PyROS, and a benchmarking study which demonstrates the utility of PyROS for two-stage RO problems. The advances include extensions of the scope of PyROS to models with uncertain variable bounds, improvements to the initializations of the subproblems used by the underlying cutting set algorithm, and extensions of the uncertainty set interfaces. The benchmarking study is performed on a library of over 8,500 instances, with variations in the nonlinearities, degree-of-freedom partitioning, uncertainty sets, and polynomial decision rule approximations. Overall, the results highlight the effectiveness of PyROS for obtaining robust solutions to optimization problems with uncertain equality constraints.

Sherman, Jason↗

Recent Advances in PyROS: The Pyomo Solver for Two-Stage Nonconvex Robust Optimization

The slides present recent algorithmic and implementation advances of the two-stage robust optimization (RO) solver PyROS, and a benchmarking study which demonstrates the utility of PyROS for two-stage RO problems. The advances include extensions of the scope of PyROS to models with uncertain variable bounds, improvements to the initializations of the subproblems used by the underlying cutting set algorithm, and extensions of the uncertainty set interfaces. The benchmarking study is performed on a library of over 8,500 instances, with variations in the nonlinearities, degree-of-freedom partitioning, uncertainty sets, and polynomial decision rule approximations. Overall, the results highlight the effectiveness of PyROS for obtaining robust solutions to optimization problems with uncertain equality constraints.

Sherman, Jason↗

Predicting Initial Trans-Membrane Pressure for Optimized Operations in UF Unit Using Random Forest

With the growing scarcity of freshwater, innovative process design mechanisms like Reverse Osmosis (RO) are increasingly gaining attention among water treatment utilities to address the rising demand. Ensuring reliable water production necessitates efficient resource utilization, minimizing downtime in (ultra-filtration) UF systems. Recent advancements in machine learning (ML) have enabled the development of accurate data-driven models for Model Predictive Control (MPC), often requiring minimal prior knowledge of underlying physical processes. In this study, we present predictive regression models based on Random Forest (RF) and Auto-Regressive (AR) approaches to forecast the initial Trans-Membrane Pressure (TMP) for each filtration cycle in data generated by Direct Potable Reuse (DPR) systems. The proposed RF-based model demonstrates superior performance compared to baseline methods, including historical mean, Last Observation Carried Forward (LOCF), and naïve AR models, across various forecasting horizons in terms of root mean square error (RMSE) metric. To evaluate how different classes of process variables contribute to TMP dynamics over time, we examine the feature importance of independent covariates across multiple forecast horizons. This analysis provides insight into the temporal relevance of operational and sensor-derived features, guiding control and monitoring strategies. Additionally, the impact of hyperparameter tuning on TMP prediction performance is studied for both direct and recursive RF modelling approaches across increasing forecast horizons. Accurate prediction of initial TMP is critical for optimizing RO operations, as it enables the development of robust modelling frameworks by accurately estimating membrane fouling trends, thereby enhancing process efficiency and long-term reliability. The demonstrated efficacy of the RF-based approach highlights its potential as a tool for real-time decision-making in water treatment systems, paving the way for advanced process optimization and sustainable water resource management.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)↗

Pilot scale test of a produced water-treatment system for initial removal of organic compounds

A pilot-scale test to remove polar and non-polar organics from produced water was performed at a disposal facility in Farmington NM. We used surfactant-modified zeolite (SMZ) adsorbent beds and a membrane bioreactor (MBR) in combination to reduce the organic carbon content of produced water prior to reverse osmosis (RO). Reduction of total influent organic carbon (TOC) to 5 mg/L or less is desirable for efficient RO system operation. Most water disposed at the facility is from coal-bed gas production, with oil production waters intermixed. Up to 20 gal/d of produced water was cycled through two SMZ adsorbent units to remove volatile organic compounds (BTEX, acetone) and semivolatile organic compounds (e.g., napthalene). Output water from the SMZ units was sent to the MBR for removal of the organic acid component of TOC. Removal of inorganic (Mn and Fe oxide) particulates by the SMZ system was observed. The SMZ columns removed up to 40% of the influent TOC (600 mg/L). BTEX concentrations were reduced from the initial input of 70 mg/L to 5 mg/L by the SMZ and to an average of 2 mg/L after the MBR. Removal rates of acetate (input 120-170 mg/L) and TOC (input up to 45 mg/L) were up to 100% and 92%, respectively. The water pH rose from 8.5 to 8.8 following organic acid removal in the MBR; this relatively high pH was likely responsible for observed scaling of the MBR internal membrane. Additional laboratory studies showed the scaling can be reduced by metered addition of acid to reduce the pH. Significantly, organic removal in the MBR was accomplished with a very low biomass concentration of 1 g/L throughout the field trial. An earlier engineering evaluation shows produced water treatment by the SMZ/MBR/RO system would cost from $0.13 to $0.20 per bbl at up to 40 gpm. Current estimated disposal costs for produced water are $1.75 to $4.91 per bbl when transportation costs are included, with even higher rates in some regions. Our results suggest that treatment by an SMZ/MBR/RO system may be a feasible alternative to current methods for produced water treatment and disposal.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heat transport measurements in turbulent rotating Rayleigh-Benard convection

We present experimental heat transport measurements of turbulent Rayleigh-Benard convection with rotation about a vertical axis. The fluid, water with Prandtl number ({sigma}) about 6, was confined in a cell which had a square cross section of 7.3 cm x 7.3 cm and a height of 9.4 cm. Heat transport was measured for Rayleigh numbers 2 x 10{sup 5} < Ra < 5 x 10{sup 8} and Taylor numbers 0 < Ta < 5 x 10{sup 9}. We show the variation of normalized heat transport, the Nusselt number, at fixed dimensional rotation rate {Omega}{sub D}, at fixed Ra varying Ta, at fixed Ta varying Ra, and at fixed Rossby number Ro. The scaling of heat transport in the range 10{sup 7} to about 10{sup 9} is roughly 0.29 with a Ro dependent coefficient or equivalently is also well fit by a combination of power laws of the form a Ra{sup 1/5} + b Ra{sup 1/3} . The range of Ra is not sufficient to differentiate single power law or combined power law scaling. The overall impact of rotation on heat transport in turbulent convection is assessed.

36 MATERIALS SCIENCE↗

Economic Analysis of a Brackish Water Photovoltaic-Operated (BWRO-PV) Desalination System: Preprint

The photovoltaic (PV)-powered reverse-osmosis (RO) desalination system is considered one of the most promising technologies in producing fresh water from both brackish and sea water, especially for small systems located in remote areas. We analyze the economic viability of a small PV-operated RO system with a capacity of 5 m3/day used to desalinate brackish water of 4000 ppm total dissolve solids, which is proposed to be installed in a remote area of the Babylon governorate in the middle of Iraq; this area possesses excellent insolation throughout the year. Our analysis predicts very good economic and environmental benefits of using this system. The lowest cost of fresh water achieved from using this system is US $3.98/ m3, which is very reasonable compared with the water cost reported by small-sized desalination plants installed in rural areas in other parts of the world. Our analysis shows that using this small system will prevent the release annually of 8,170 kg of CO2, 20.2 kg of CO, 2.23 kg of CH, 1.52 kg of particulate matter, 16.41 kg of SO2, and 180 kg of NOx.

14 SOLAR ENERGY↗

Fresh Water Generation from Aquifer-Pressured Carbon Storage

Can we use the pressure associated with sequestration to make brine into fresh water? This project is establishing the potential for using brine pressurized by Carbon Capture and Storage (CCS) operations in saline formations as the feedstock for desalination and water treatment technologies including reverse osmosis (RO) and nanofiltration (NF). Possible products are: Drinking water, Cooling water, and Extra aquifer space for CO{sub 2} storage. The conclusions are: (1) Many saline formation waters appear to be amenable to largely conventional RO treatment; (2) Thermodynamic modeling indicates that osmotic pressure is more limiting on water recovery than mineral scaling; (3) The use of thermodynamic modeling with Pitzer's equations (or Extended UNIQUAC) allows accurate estimation of osmotic pressure limits; (4) A general categorization of treatment feasibility is based on TDS has been proposed, in which brines with 10,000-85,000 mg/L are the most attractive targets; (5) Brines in this TDS range appear to be abundant (geographically and with depth) and could be targeted in planning future CCS operations (including site selection and choice of injection formation); and (6) The estimated cost of treating waters in the 10,000-85,000 mg/L TDS range is about half that for conventional seawater desalination, due to the anticipated pressure recovery.

20 FOSSIL-FUELED POWER PLANTS↗

Influence of concentration polarization and thermodynamic non-ideality on salt transport in reverse osmosis membranes

The classic Merten and Lonsdale transport model for reverse osmosis membranes was reformulated to explicitly demonstrate the effects of concentration polarization and solution phase thermodynamic non-idealities on salt transport. A framework presented here accounts for the concentration dependence of ion activity coefficients in salt solutions, which was not explicitly included in the classic model. This approach was applied to four salt solutions, NaCl, MgCl 2 , CaCl 2 , and Na 2 SO 4 , tested in cross-flow conditions for a commercial RO membrane, Dow Filmtec™ BW30XFR. Salt transport coefficients corrected for concentration polarization and non-ideal thermodynamic effects, B a , were calculated as a function of permeate flux and compared with apparent salt transport coefficients, B . Finally, these corrections were significant, resulting in B a values greater than B values by a factor of 1.3–2.1 for 2:1 and 1:2 salts (i.e., MgCl 2 , CaCl 2 , and Na 2 SO 4 ). B a values for NaCl (a 1:1 salt), however, were similar to or somewhat smaller than B values.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗