Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RESIDENTIAL LIGHTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

West Village Student Housing Phase I: Apartment Monitoring and Evaluation

Building America team Alliance for Residential Building Innovation (ARBI) worked with the University of California, Davis and the developer partner West Village Community Partnership (WVCP) to evaluate performance on 192 student apartments completed in September, 2011 as part of Phase I of the multi-purpose West Village project. West Village is the largest planned zero net energy community in the United States. The campus neighborhood is designed to enable faculty, staff, and students to affordably live near campus, take advantage of environmentally friendly transportation options, and participate fully in campus life. The aggressive energy efficiency measures that are incorporated in the design contribute to source energy reductions of 37% over the B10 Benchmark. These measures include increased wall and attic insulation, high performance windows, high efficiency heat pumps for heating and cooling, central heat pump water heaters (HPWHs), 100% high efficacy lighting, and ENERGY STAR major appliances. The report discusses how measured energy use compares to modeling estimates over a 10-month monitoring period and includes a cost effective evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Residential Energy Retrofits

To advance the market penetration of residential retrofits, Oak Ridge National Laboratory (ORNL) and Southface Energy Institute (Southface) partnered to provide technical assistance on nine home energy retrofits in metropolitan Atlanta with simulated source energy savings of 30% to 50%. Retrofit measures included duct sealing, air infiltration reductions, attic sealing and roofline insulation, crawlspace sealing, HVAC and water heating equipment replacement, and lighting and appliance upgrades. This paper will present a summary of these measures and their associated impacts on important home performance metrics, such as air infiltration and duct leakage. The average estimated source energy savings for the homes is 33%, and the actual heating season average savings is 32%. Additionally, a case study describing expected and realized energy savings of completed retrofit measures of one of the homes is described in this paper.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

West Village Student Housing Phase I: Apartment Monitoring and Evaluation

Building America team Alliance for Residential Building Innovation (ARBI) worked with the University of California, Davis (UC Davis) and the developer partner West Village Community Partnership (WVCP) to evaluate performance on 192 student apartments completed in September, 2011 as part of Phase I of the multi-purpose West Village project. West Village, the largest planned zero net energy community in the United States. The campus neighborhood is designed to enable faculty, staff and students to affordably live near campus, take advantage of environmentally friendly transportation options, and participate fully in campus life. The aggressive energy efficiency measures that are incorporated in the design contribute to source energy reductions of 37% over the B10 Benchmark. The energy efficiency measures that are incorporated into these apartments include increased wall & attic insulation, high performance windows, high efficiency heat pumps for heating and cooling, central heat pump water heaters (HPWHs), 100% high efficacy lighting, and ENERGY STAR major appliances. Results discuss how measured energy use compares to modeling estimates over a 10 month monitoring period and includes a cost effective evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Distributionally Robust Bilevel Optimization Model for Distribution Network With Demand Response Under Uncertain Renewables Using Wasserstein Metrics

Here, we consider a distribution network integrating demand response (DR) participants in the presence of uncertain renewable suppliers and outdoor temperatures. A bilevel optimization model is proposed to capture the intricate dynamics between price-incentivized DR participants and distribution system operations, including energy procurement and active/reactive power flows. The model is formulated as a distributional robust bilevel optimization using Wasserstein metrics. We show favorable data-driven properties including out-of-sample guarantee and asymptotic consistency. Furthermore, we present a tractable mixed-integer linear programming reformulation and characterize the worst-case distribution. Computational experiments are conducted on a modified 33-bus system. Our findings underscore the efficacy of the pricing strategies derived from the proposed bilevel optimization model. These strategies not only effectively manage DR participants' behavior but also bring equity considerations among households with various characteristics to light. The results contribute to a deeper understanding of the interplay between distribution system operators and DR participants.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study of Voltage-Dependent Harmonic Characteristics of Residential Appliances

This paper focuses on the electrical characteristics of residential and domestic appliances and their effects to the power grid. With the ever-changing load landscape and the introduction of power electronics-based equipment and energy-efficient loads, it is increasingly important to have a thorough knowledge of their power quality and harmonic characteristics in addition to conventional load models. This is critical to the accurate load representations, particularly for the complete bottom-up load models, in voltage stability assessment, determining possible interactions at harmonic frequencies, the effect of the system impedance, as well as possible voltage sag and swell and unbalance conditions. For this study, the household appliances are grouped into five categories: lighting, power electronics, resistive, motor, and aggregated loads. The effect of the voltage variation on the load current characteristics is also studied. The results from laboratory experiments involving most of the commonly used domestic appliances are analyzed within a range of +10%/-5% of the nominal supply voltage and within a range of +/-3 Hz of the nominal supply frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Determinants of residential electricity consumption: Using smart meter data to examine the effect of climate, building characteristics, appliance stock, and occupants' behavior

We propose a method to examine structural and behavioral determinants of residential electricity consumption, by developing separate models for daily maximum (peak) and minimum (idle) consumption. We apply our method on a data set of 1628 households' electricity consumption. The results show that weather, location and floor area are among the most important determinants of residential electricity consumption. In addition to these variables, number of refrigerators and entertainment devices (e.g., VCRs) are among the most important determinants of daily minimum consumption, while number of occupants and high-consumption appliances such as electric water heaters are the most significant determinants of daily maximum consumption. Installing double-pane windows and energy-efficient lights helped to reduce consumption, as did the energy-conscious use of electric heater. Acknowledging climate change as a motivation to save energy showed correlation with lower electricity consumption. Households with individuals over 55 or between 19 and 35 years old recorded lower electricity consumption, while pet owners showed higher consumption. Contrary to some previous studies, we observed no significant correlation between electricity consumption and income level, home ownership, or building age. Some otherwise energy-efficient features such as energy-efficient appliances, programmable thermostats, and insulation were correlated with slight increase in electricity consumption. (C) 2013 Elsevier Ltd. All rights reserved.

Kavousian, A↗

High-Performance Integrated Window and Façade Solutions for California

The researchers developed a new generation of high-performance façade systems and supporting design and management tools to support industry in meeting California’s greenhouse gas reduction targets, reduce energy consumption, and enable an adaptable response to minimize real-time demands on the electricity grid. The project resulted in five outcomes: (1) The research team developed an R-5, 1-inch thick, triplepane, insulating glass unit with a novel low-conductance aluminum frame. This technology can help significantly reduce residential cooling and heating loads, particularly during the evening. (2) The team developed a prototype of a windowintegrated local ventilation and energy recovery device that provides clean, dry fresh air through the façade with minimal energy requirements. (3) A daylight-redirecting louver system was prototyped to redirect sunlight 15–40 feet from the window. Simulations estimated that lighting energy use could be reduced by 35–54 percent without glare. (4) A control system incorporating physics-based equations and a mathematical solver was prototyped and field tested to demonstrate feasibility. Simulations estimated that total electricity costs could be reduced by 9-28 percent on sunny summer days through adaptive control of operable shading and daylighting components and the thermostat compared to state-of-the-art automatic façade controls in commercial building perimeter zones. (5) Supporting models and tools needed by industry for technology R&D and market transformation activities were validated. Attaining California’s clean energy goals require making a fundamental shift from today’s ad-hoc assemblages of static components to turnkey, intelligent, responsive, integrated building façade systems. These systems offered significant reductions in energy use, peak demand, and operating cost in California.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of the Value Proposition of High-Efficiency, Multijunction Solar Modules for Residential Rooftop Installations

Utilizing detailed bottom-up models, we analyze the potential markets for high-efficiency photovoltaic modules in the United States. We first estimate the fraction of area-constrained residential rooftops that could benefit from increasing the availability of high-efficiency systems. We then model the impact of efficiency on installed system costs in these area-constrained scenarios. Finally, we explore the value proposition of high-efficiency, fixed-tilt micro-concentrator photovoltaic modules in a series of case studies of residential customers, modeling the levelized cost of energy, payback period, and annual bill savings. We find that efficiency can provide significant savings in installed system cost and improve value to the solar system owner. The improvement in value depends on location and the size of the rooftop, as well as the ability of a given technology to collect diffuse light and achieve low module costs.

14 SOLAR ENERGY↗

Solar-Powered Aerogel-Based Adsorptive Air Conditioning

The DOE estimates the total primary energy consumption for commercial buildings was 10.72 quadrillion BTU (quads) in 1983, compared with 14.74 quads for the residential sector. According to the DOE Building Technologies Program, 40–60% of the energy used in U.S. commercial (and residential) buildings is for HVAC, creating massive potential for energy savings with a system that could cut cooling energy use by at least 30–60%. Initial vertical segments in the commercial building market include government and commercial office buildings; government facilities such as prisons, military bases, and schools; hotels and resorts; farming, wineries and other rural facilities; and general light industrial offices (e.g., printers and clothing makers). We propose a solar powered aerogel-based adsorption cooling system, including the completion and testing of a working prototype at an existing HVAC testing facility and technology-maturation testing at an existing beta-testing site. In the cooling system, solar radiation is focused by solar collectors onto on bed, which contains ultra high surface area aerogel. Heating causes thermal desorption of a refrigerant previously adsorbed into the aerogel’s pores. Refrigerant desorption increases the gas-phase pressure in the pores, thereby forcing the gaseous refrigerant to flow out of the first irradiated bed (Bed A) and through a two-stage condenser. In the condenser, heat is first removed from the hot gaseous refrigerant by a stream of water that eventually flows into a hot water heater and storage system. The refrigerant is then further cooled by chilled refrigerant leaving the evaporator after vaporization. After passing through the two-stage condenser, the gaseous refrigerant undergoes expansion through an expansion valve. A portion of the refrigerant condenses in the evaporator, while some of the refrigerant is flashed and exits the evaporator. The evaporator absorbs heat from the area being cooled, which results in further vaporization of the refrigerant. The cool, vaporized refrigerant leaves the evaporator, passing through tubes in the shell-and-tube heat exchanger comprising the second stage of the two-stage condenser. After leaving the tube side of this heat exchanger, it flows to the second bed of aerogel (Bed B), which is maintained at a relatively low temperature by water entering the building and destined for the hot water tank. During the first cycle, most of the refrigerant adsorbs on Bed B. When the refrigeration cycle is reversed, the refrigerant is thermally desorbed from Bed B, and adsorbed on the cooler Bed A. As the cycling rate increases, the quantity of adsorption media, the system size, and the associated cost becomes smaller. It appears that an optimized system can meet targeted performance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Using Residential and Office Building Archetypes for Energy Efficiency Building Solutions in an Urban Scale: A China Case Study

Building energy consumption accounts for 36% of the overall energy end use worldwide and is growing rapidly as developing countries continue to urbanize. Understanding the energy use at urban scale will lay the foundation for identification of energy efficiency opportunities to be deployed at speed. China has almost half of global new constructions and plays an important role in building suitability. However, an open source national building energy consumption database is not available in China. To provide data support for building energy consumptions, this paper used a simulation method to develop an urban building energy consumption database for a pilot city in Wuhan, China. First, residential, small, and large office building archetype energy models were created in EnergyPlus to represent typical building energy consumption in Wuhan. The baseline reference model simulation results were further validated using survey data from the literature. Second, stochastic simulations were conducted to consider different design parameters and occupants’ energy usage intensity scenarios, such as thermal properties of the building envelope, lighting power density, equipment power density, HVAC (heating, ventilation and air conditioning) schedule, etc. A building energy consumption database was generated for typical building archetypes. Third, data-driven regression analysis was conducted to support quick building energy consumption prediction using key high- level building information inputs. Finally, a web-based urban energy platform and an interface were developed to support further third-party application development. The research is expected to provide fast energy efficiency building design solutions for urban planning, new constructions as well as building retrofits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Occupancy Simulation in Three Residential Research Houses

Three houses of similar floor plan are being compared for energy consumption. The first house is a typical builder house of 2400 ft2 (223 m2) in east Tennessee. The second house contains retrofits available to a home owner such as energy efficient appliances, windows and HVAC, as well as an insulated attic which contains HVAC duct work. The third house was built using optimum-value framing construction with photovoltaic modules and solar water heating. To consume energy researchers have set up appliances, lights, and plug loads to turn on and off automatically according to a schedule based on the Building America Research Benchmark Definition. As energy efficiency continues to be a focus for protecting the environment and conserving resources, experiments involving whole house energy consumption will be done. In these cases it is important to understand how to simulate occupancy so that data represents only house performance and not human behavior. The process for achieving automated occupancy simulation will be discussed. Data comparing the energy use of each house will be presented and it will be shown that the third house used 66% less and the second house used 36% less energy than the control house in 2010. The authors will discuss how energy prudent living habits can further reduce energy use in the third house by 23% over the average American family living in the same house.

Boudreaux, Philip R↗

Wisdom Way Solar Village: Design, Construction, and Analysis of a Low Energy Community

This report describes work conducted at the Wisdom Way Solar Village (WWSV), a community of 10 high performance duplexes (20 homes) in Greenfield, MA, constructed by Rural Development, Inc. (RDI). Building America's CARB team monitored temperatures and comfort in several homes during the winter of 2009-2010, and tracked utility bill information from 13 occupied homes. Because of efficient lights, appliances, and conscientious home occupants, the energy generated by the solar electric systems exceeded the electric energy used in most homes.

14 SOLAR ENERGY↗

DOE Zero Energy Ready Home Case Study, Weiss Building & Development, LLC., System Home, River Forest, Illinois

The Passive House Challenge Home located in River Forest, Illinois, is a 5-bedroom, 4.5-bath, 3,600 ft2 two-story home (plus basement) that costs about $237 less per month to operate than a similar sized home built to the 2009 IECC. For a home with no solar photovoltaic panels installed, it scored an amazingly low 27 on the Home Energy Rating System (HERS) score.An ENERGY STAR-rated dishwasher, clothes washer, and refrigerator; an induction cooktop, condensing clothes dryer, and LED lighting are among the energy-saving devices inside the home. All plumbing fixtures comply with EPA WaterSense criteria. The home was awarded a 2013 Housing Innovation Award in the "systems builder" category.

Building America↗

NexusHaus: Solar Decathlon House

The University of Texas at Austin and The Technical University of Munich 2015 Solar Decathlon house is called Nexushaus because it combines UT Austin and TUM students in an affordable modular residential green building in the context of Austin, Texas, based on shape forming principles found in nature that demonstrates transformative technologies in Zero Net Energy, Zero Net Water and Carbon Neutrality. To meet the needs of the competition, a portable modular design has been developed with an assembly that enables ease of installation and both quantitative and qualitative performance in the design. The prefabricated house sits lightly on the land and forms the superstructure for photovoltaic technologies, rainwater collection, aquaculture and permaculture gardening and indoor/outdoor living. The ultimate goal of Nexushaus is to serve as a potential prototype for a next-generation modular home that could be reproduced in mass in an assembly plant in Austin.

solar decathlon, zero net energy, zero net water, ↗

Photocatalytic degradation of cooking fume on a TiO2-coated carbon nanotubes composite filter

Highlights: • The TiO{sub 2}-coated carbon nanotube composite filter was fabricated for treating cooking fume particles. • MWCNTs formed a network-like structure surface layer of composite filter. • The composite filter showed high surface area. • The composite filter was tested in oleic acid decomposition reaction. • Parallel reaction mechanism was attempted to describe oleic acid degradation. A TiO{sub 2}/MWCNTs/Al{sub 2}O{sub 3}/NF (TiO{sub 2} nanoparticles/multi-walled carbon nanotubes /Al{sub 2}O{sub 3}-modified nickel foams) composite filter was prepared through grown of MWCNTs upon Al{sub 2}O{sub 3}-modified nickel foams using chemical vapor deposition (CVD) method and then coated TiO{sub 2} nanoparticles onto MWCNTs using dip-coating method. The MWCNTs forms a network-like structure on the surface layer of composite filter. The BET surface area of TiO{sub 2}/MWCNTs/Al{sub 2}O{sub 3}/NF composite filter is more than 375 times higher than that of the pristine nickel foam. The degradation performance of oil particles was evaluated. Under optimized reaction conditions, 90% of the oleic acid on the filter was decomposed after 25 h. In addition, the effect of reaction temperature and light intensity were studied. Increased reaction temperature and light intensity were found to significantly improve the degradation rate and restrain the formation of refractory product. Furthermore, a parallel reaction kinetic model was adopted for degradation of oleic acid on the composite filter. The composite filter can reduces the accumulation of oil particles on the filter and the energy consumption of the filter. This approach proposes a new way to treat the cooking fume emission at residential building roofs.

54 ENVIRONMENTAL SCIENCES↗

Thermal and other tests of photovoltaic modules performed in natural sunlight

The bulk of the testing was the characterization of twenty-nine modules according to their nominal operating cell temperature (NOCT) and the effect on NOCT of changes in module design, various residential roof mounting configurations, and dirt accumulation. Other tests, often performed parallel with the NOCT measurements, evaluated the improvement in electrical performance by cooling the modules with water and by channeling the waste heat into a phase change material (wax). Electrical degradation resulting from the natural marriage of photovoltaic and solar water heating modules was also demonstrated. Cost effectiveness of each of these techniques are evaluated in light of the LSA cost goal of $0.50 per watt.

Stultz, J. W.↗

DOE Zero Energy Ready Home Case Study: Montlake Modern - Seattle, Washington

This case study describes a DOE Zero Energy Ready Home in Seattle, WA, that scored HERS 42 without PV and a -1 with PV. This 3,192 ft2 custom home has 6-inch SIP walls, a 12-inch SIP roof, an R-28 ICF-insulated foundation slab edge with R-20 rigid foam under the slab; an air-to-water heat pump plus radiant floor heat; 100% LED lighting; filtered-fan-powered fresh air intake; triple-pane windows, 9.7 kWh PV for electric car charging station.

air-to-water heat pump↗

Wisdom Way Solar Village: Design, Construction, and Analysis of a Low Energy Community

This report describes work conducted at the Wisdom Way Solar Village (WWSV), a community of 10 high performance duplexes (20 homes) in Greenfield, MA, constructed by Rural Development, Inc. (RDI). Building America's CARB team monitored temperatures and comfort in several homes during the winter of 2009-2010, and tracked utility bill information from 13 occupied homes. Because of efficient lights,appliances, and conscientious home occupants, the energy generated by the solar electric systems exceeded the electric energy used in most homes.

14 SOLAR ENERGY↗