Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REMOVAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

REMOVAL OF SOLIDS FROM HIGHLY ENRICHED URANIUM SOLUTIONS USING THE H-CANYON CENTRIFUGE

Prior to the dissolution of Pu-containing materials in HB-Line, highly enriched uranium (HEU) solutions stored in Tanks 11.1 and 12.2 of H-Canyon must be transferred to provide storage space. The proposed plan is to centrifuge the solutions to remove solids which may present downstream criticality concerns or cause operational problems with the 1st Cycle solvent extraction due to the formation of stable emulsions. An evaluation of the efficiency of the H-Canyon centrifuge concluded that a sufficient amount (> 90%) of the solids in the Tank 11.1 and 12.2 solutions will be removed to prevent any problems. We based this conclusion on the particle size distribution of the solids isolated from samples of the solutions and the calculation of particle settling times in the centrifuge. The particle size distributions were calculated from images generated by scanning electron microscopy (SEM). The mean particle diameters for the distributions were 1-3 {micro}m. A significant fraction (30-50%) of the particles had diameters which were < 1 {micro}m; however, the mass of these solids is insignificant (< 1% of the total solids mass) when compared to particles with larger diameters. It is also probable that the number of submicron particles was overestimated by the software used to generate the particle distribution due to the morphology of the filter paper used to isolate the solids. The settling times calculated for the H-Canyon centrifuge showed that particles with diameters less than 1 to 0.5 {micro}m will not have sufficient time to settle. For this reason, we recommend the use of a gelatin strike to coagulate the submicron particles and facilitate their removal from the solution; although we have no experimental basis to estimate the level of improvement. Incomplete removal of particles with diameters < 1 {micro}m should not cause problems during purification of the HEU in the 1st Cycle solvent extraction. Particles with diameters > 1 {micro}m account for > 99% of the solid mass and will be efficiently removed by the centrifuge; therefore, the formation of emulsions during solvent extraction operations is not an issue. Under the current processing plan, the solutions from Tanks 11.1 and 12.2 will be transferred to the enriched uranium storage (EUS) tank following centrifugation. The solution from Tanks 11.1 and 12.2 may remain in the EUS tank for an extended time prior to purification. The effects of extended storage on the solution were not evaluated as part of this study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Development of a Parameterized Scatter Removal Algorithm for Nuclear Materials Identification System Imaging

This dissertation presents a novel method for removing scattering effects from Nuclear Materials Identification System (NMIS) imaging. The NMIS uses fast neutron radiography to generate images of the internal structure of objects non-intrusively. If the correct attenuation through the object is measured, the positions and macroscopic cross-sections of features inside the object can be determined. The cross sections can then be used to identify the materials and a 3D map of the interior of the object can be reconstructed. Unfortunately, the measured attenuation values are always too low because scattered neutrons contribute to the unattenuated neutron signal. Previous efforts to remove the scatter from NMIS imaging have focused on minimizing the fraction of scattered neutrons which are misidentified as directly transmitted by electronically collimating and time tagging the source neutrons. The parameterized scatter removal algorithm (PSRA) approaches the problem from an entirely new direction by using Monte Carlo simulations to estimate the point scatter functions (PScFs) produced by neutrons scattering in the object. PScFs have been used to remove scattering successfully in other applications, but only with simple 2D detector models. This work represents the first time PScFs have ever been applied to an imaging detector geometry as complicated as the NMIS. By fitting the PScFs using a Gaussian function, they can be parameterized and the proper scatter for a given problem can be removed without the need for rerunning the simulations each time. In order to model the PScFs, an entirely new method for simulating NMIS measurements was developed for this work. The development of the new models and the codes required to simulate them are presented in detail. The PSRA was used on several simulated and experimental measurements and chi-squared goodness of fit tests were used to compare the corrected values to the ideal values that would be expected with no scattering. Using the PSRA resulted in an improvement of the chi-squared test by a factor of 60 or more when applied to simple homogeneous objects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluating and Enhancing Iron Removal via Filterable Iron Precipitates Formation during Coal-Waste Bioleaching

Iron removal via jarosite precipitate formation is a commonly used technique in various hydrometallurgical processes. Excess iron removal often becomes essential to an overall metal recovery circuit. This is particularly important to processes involving iron-bearing minerals. A technique, which involved the use of pyrite to generate acid for leaching, for iron removal is critical to enabling the process. Iron removal using CaO or similar reagents is expensive and often results in lost product. In the present study, various compounds that facilitate jarosite formation, namely Na2SO4, NH4OH, KCl, and KOH, were utilized and their effect in precipitation was observed. Visual Minteq assisted simulations were run in order to evaluate favorable conditions for iron removal. Morphology and elemental composition of precipitates were analyzed using scanning electron microscopy equipped with energy-dispersive X-ray spectroscopy, and the phase purity was identified using X-ray diffraction analysis.

99 GENERAL AND MISCELLANEOUS↗

Carbon Removal Accounting for a Sustainable Future: Distributing CO 2 Flows in Multiservice Systems

Carbon dioxide removal (CDR) systems are an integral part of sustainable pathways limiting global warming to less than 2.0 °C. When the sole purpose of CDR is capturing and storing atmospheric CO 2 , carbon registries offer detailed procedures to calculate the carbon removal credits. However, the registries do not address how to distribute CO 2 flows when CDR provides additional services. Standardized, transparent rules for distributing CO 2 flows among CDR services are required for the formation of efficient private and public carbon markets. The lack of such rules could result in double counting if those reductions are allocated to more than one service, decreasing the trustworthiness of carbon removal credits or deterring the delivery of an additional low-carbon service, thus limiting the economic viability and deployment of CDR. We examine allocation rules in carbon registries and carbon accounting guidelines, including their life cycle assessment (LCA) principles. We evaluate physical (mass-based) and non-physical (economic) allocation methods using a generic CDR system and find both to be unworkable. We then develop a mass balance (MB) approach which can reliably allocate captured and stored carbon (CSC) between carbon removal credits and other services based on the value CO 2 removal in those markets. This practical approach to allocation can be used in a transparent way to provide flexibility that would allow CDR services to capture the value of the multiple services they provide and, through this, promote the deployment of these sustainable alternatives.

54 ENVIRONMENTAL SCIENCES↗

SELECTIVE REMOVAL OF STRONTIUM AND CESIUM FROM SIMULATED WASTE SOLUTION WITH TITANATE ION-EXCHANGERS IN A FILTER CARTRIDGE CONFIGURATIONS-12092

Experimental results for the selective removal of strontium and cesium from simulated waste solutions with monosodium titanate (MST) and crystalline silicotitanate (CST) laden filter cartridges are presented. In these proof-of-principle tests, effective uptake of both Sr-85 and Cs-137 were observed using ion-exchangers in this filter cartridge configuration. At low salt simulant conditions, the instantaneous decontamination factor (D{sub F}) for Sr-85 with MST impregnated filter membrane cartridges measured 26, representing 96% Sr-85 removal efficiency. On the other hand, the Sr-85 instantaneous D{sub F} with co-sintered active MST cartridges measured 40 or 98% Sr-85 removal efficiency. Strontium-85 removal with the MST impregnated membrane cartridges and CST impregnated membrane cartridges, placed in series arrangement, produced an instantaneous decontamination factor of 41 compared to an instantaneous decontamination factor of 368 for strontium-85 with co-sintered active MST cartridges and co-sintered active CST cartridges placed in series. Overall, polyethylene co-sintered active titanates cartridges performed as well as titanate impregnated filter membrane cartridges in the uptake of strontium. At low ionic strength conditions, there was a significant uptake of Cs-137 with co-sintered CST cartridges. Tests results with CST impregnated membrane cartridges for Cs-137 decontamination are currently being re-evaluated. Based on these preliminary findings we conclude that incorporating MST and CST sorbents into membranes represent a promising method for the semi-continuous removal of radioisotopes of strontium and cesium from nuclear waste solutions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Effect of Si and Al Concentration Ratios on the Removal of U(VI) under Hanford Site 200 Area Conditions-12115

Injection of reactive gases, such as NH{sub 3}, is an innovative technique to mitigate uranium contamination in soil for a vadose zone (VZ) contaminated with radionuclides. A series of experiments were conducted to examine the effect of the concentration ratio of silicon to aluminum in the presence of various bicarbonate concentrations on the coprecipitation process of U(VI). The concentration of Al in all tests remained unchanged at 2.8 mM. Experiments showed that the removal efficiency of uranium was not significantly affected by the different bicarbonate and U(VI) concentrations tested. For the lower Si:Al molar ratios of 2:1 and 18:1, the removal efficiency of uranium was relatively low (≤ 8%). For the Si:Al molar ratio of 35:1, the removal efficiency of uranium was increased to an average of ∼82% for all bicarbonate concentrations tested. At higher Si:Al molar ratios (53:1 and above), a relatively high removal efficiency of U(VI), approximately 85% and higher, was observed. These results demonstrate that the U(VI) removal efficiency is more affected by the Si:Al molar ratio than by the bicarbonate concentration in solution. The results of this experiment are promising for the potential implementation of NH{sub 3} gas injection for the remediation of U(VI) -contaminated VZ. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimization of sludge waste removal flowsheet at SRS through incorporation of testing and in-tank waste experience - 15262

Sludge waste removal at SRS serves two purposes: to remove the sludge for tank closure, and to provide feed for sludge processing and immobilization via vitrification. Lessons learned from previous sludge removal campaigns, in addition to testing and modeling, have led to opportunities for improvements to the overall sludge removal process, as well as marked improvements in sludge removal equipment technology and operation. Testing, modeling, and experience have led to better understanding of sludge properties and behavior during agitation and settling; the primary consideration for sludge agitation is the retention and release of radiolytic hydrogen, which must be managed in order to prevent flammability concerns in the waste tanks. Mixing devices have improved considerably, from early sluicing devices to the long-shafted slurry pumps and submersible mixer pumps currently in use at SRS, as well as ongoing development with new commercial submersible mixer pumps. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Synthesis of Bismuth Functionalized Grapheme Oxide for Radioactive Iodine Gas Removal - 16114

Released radioactive iodine from nuclear reactors and nuclear severe accidents, such as those experienced at Chernobyl and Fukushima, is one of the most hazardous materials and can affect human health. Uptake of radioactive iodine from gaseous and aqueous waste, consisting of mainly organic forms such as methyl iodide and elemental iodine after reacting with organic matter in scrubber process, is a recent concern during nuclear power plant operation. In general, Triethylenediamine (TEDA) or KI-impregnated activated carbons, silver-loaded silica aerogels, and silver-loaded zeolite are used to remove radioactive iodine compounds. However, previous research has shown TEDA and KI-impregnated activated carbons to have some limitations for use in responding to severe accidents or in pressurized-water reactors, because they are easily burned up and the iodine removal efficiency of silver-loaded sorbents is greatly decreased at high temperatures. To improve the capability of synthesized sorbent material used in iodine gas removal, highly efficient sorbents for methyl and elemental iodine removal were prepared through the functionalization of graphene oxide (GO) with bismuth. GO was synthesized from natural graphite powder (99.95%) by the modified Hummers method, and then mixed with Bi(NO{sub 3}){sub 3}.5H{sub 2}O. After developing a sorbent for the removal of iodine, the synthesized sorbent was characterized using x-ray diffraction, a scanning electron microscope/energy dispersive spectrometer, and thermogravimetric analysis/differential scanning calorimetry, and the surface area of sorbents was determined using the BET-N{sub 2} adsorption method. Methyl iodine batch experiments were conducted for 7 days and elemental iodine gas adsorption experiments were conducted at high temperature (190 deg. C) using a carrier gas (air). The final concentration of iodine in batch and off-gas scrubber solutions (0.1 M NaOH) was analyzed using inductively coupled plasma mass spectrometry. The breakthrough curve and decontamination factor values were also investigated using bismuth-functionalized GO and the results were compared with Ag-zeolite, Sn-apatite, and activated carbon. (authors)

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Demonstration of SuperLig{sup R} 605 and SuperLig{sup R} 644 in a Regeneration Flow Sheet to Remove Radioactive Strontium and Cesium from Seawater - 16236

Remediation techniques are needed for efficient removal of radioactive strontium and cesium from seawater. Molecular Recognition Technology, using selective SuperLig{sup R} resins, demonstrates a clean chemistry approach to solving this problem. Molecular Recognition Technology offers high levels of separation of chemically pure metal contaminants, whose subsequent disposal is compatible with simple waste forms (grout and glass). SuperLig{sup R} resins can be regenerated with common reagents and used many times, limited by a dose of 1 E+9 Rad, which assures low volumes of secondary solid waste. The metal selectivity of the SuperLig{sup R} resin ensures that the solid waste is of low residual activity. These properties of sustainability are illustrated in a project that demonstrated the ability of two SuperLig{sup R} resins to selectively remove Cs and Sr from a seawater mimic representative of the contaminated seawater in Fukushima, Dai'ichi, Japan harbor. Removal of radioactive Sr-90 and Cs-134/Cs-137 from seawater using conventional ion exchange or a complexing agent is complicated by the presence of large excesses of competing ions such as Na, K, Ca, and Mg, which can be co-extracted. These competing ions, if co-extracted, reduce the capacity of a single pass resin with the consequent increase in volume of spent resin or decrease in capacity of a regenerable resin. The successful demonstration reported in this study has shown the ability of two proprietary resins, SuperLig{sup R} 605 and SuperLig{sup R} 644, to remove Sr and Cs, respectively, with high selectivity from simulated solutions containing these metal ions together with major constituents of seawater at their normal concentrations. This effort was part of a demonstration project to investigate methods for removal of Sr-90 and Cs-134/Cs-137 from 160,000 cubic meters of seawater impounded at Fukushima, Dai'ichi, Japan harbor. SuperLig{sup R} resins can be regenerated by elution with small volumes of simple acid solutions. SuperLig{sup R} resins have a high tolerance to radiation, with their performance not being degraded by doses of 1.0 E+9 Rad. Estimates, based on the results obtained, are that Cs and Sr levels in the volume of seawater in the Fukushima, Dai'ichi, Japan harbor could be reduced to desired discharge limits in 200 days with some 30 cubic meters of the two SuperLig{sup R} resins and that decontamination factors of 10 or more could be achieved. Results of the demonstration, together with advantages of the Molecular Recognition Technology process over conventional procedures for these separations are presented and discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Material removal and surface figure during pad polishing of fused silica

The material removal and surface figure after ceria pad polishing of fused silica glass have been measured and analyzed as a function of kinematics, loading conditions, and polishing time. Also, the friction at the workpiece/lap interface, the slope of the workpiece relative to the lap plane, and lap viscoelastic properties have been measured and correlated to material removal. The results show that the relative velocity between the workpiece & lap (determined by the kinematics) and the pressure distribution determine the spatial and temporal material removal and hence the final surface figure of the workpiece. In the case where the applied loading and relative velocity distribution over the workpiece are spatially uniform, a significant non-uniform spatial material removal from the workpiece surface is observed. This is due to a non-uniform pressure distribution resulting from: (1) a moment caused by a pivot point and interface friction forces; (2) viscoelastic relaxation of the polyurethane lap; and (3) a physical workpiece/lap interface mismatch. Both the kinematics and these contributions to the pressure distribution are quantitatively described, and then combined to form a spatial and temporal Preston model & code for material removal (called Surface Figure or SurF{copyright}). The surface figure simulations are consistent with the experiment for a wide variety of polishing conditions. This study is an important step towards deterministic full-aperture polishing, which would allow optical glass fabrication to be performed in a more repeatable, less iterative, and hence more economical manner.

42 ENGINEERING↗

Selective Electrochemical End‐Group Removal Enhances Polymer Thermal Stability

Here we introduce an electrochemical strategy for the selective and quantitative removal of thiocarbonylthio end groups from polymers prepared by reversible addition–fragmentation chain transfer (RAFT) or photoiniferter polymerization. Our results indicate that applying a cathodic potential in an undivided cell promotes reductive cleavage of the thiocarbonylthio moiety, generating terminal polymer radicals that are efficiently capped with hydrogen atoms in the presence of benign donors. This transformation proceeds cleanly across diverse polymer backbones and end-group chemistries, including trithiocarbonates and dithiobenzoates, without chain coupling or degradation. Moreover, the applied potential can be tuned to enable chemoselective end-group removal in mixed-polymer systems, a level of control inaccessible by thermal, photochemical, or nucleophilic strategies. Beyond delivering colorless and optically transparent materials, electrochemical end-group removal significantly enhances polymer stability. Poly(methyl methacrylate) subjected to electrochemical end-group removal exhibited a T 95 of 342 °C, exceeding the stabilities of analogous polymers with end groups removed by aminolysis (T 95 = 260 °C) or radical-based methods (T 95 = 299 °C). These findings demonstrate redox-directed post-polymerization modification as a tool for designing robust, transparent, and thermally stable macromolecules and establish electrochemistry as a platform strategy in polymer synthesis and processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scavenger removal of bird carcasses at simulated wind turbines: Does carcass type matter?

Abstract Wind energy development can negatively impact bird populations due to bird–turbine collisions. To accurately estimate bird mortality at wind farms, the number of dead birds found under turbines is commonly corrected for carcass removal by scavengers, which is quantified by measuring persistence of experimental carcasses through time. These studies often use domestic birds as surrogates because carcasses of wild birds (e.g., raptors) are difficult to obtain. We assessed scavenger removal of carcasses from five bird species at simulated turbines to determine whether domestic surrogates are scavenged at a different rate than raptors, species of interest for wind turbine mortality. The percentage of carcasses scavenged during 14‐d rounds ranged from 34.6% for American kestrels ( Falco sparverius ) to 65.4% for chickens ( Gallus gallus ), and the percentage of carcasses completely removed ranged from 13.5% for red‐tailed hawks ( Buteo jamaicensis ) to 67.3% for northern bobwhites ( Colinus virginianus ). Carcass type (i.e., species) was the only predictor included in the best‐fit logistic regression model of complete carcass removal, and a survival analysis indicated carcass type influenced elapsed time to scavenging events. Our results suggest the use of surrogate species to quantify carcass removal at wind turbines could lead to inaccurate mortality estimates.

17 WIND ENERGY↗

Removal of Retrievable Self-Expandable Metallic Tracheobronchial Stents: An 18-Year Experience in a Single Center

PurposeThe purpose of the study was to retrospectively evaluate the technical outcomes of removal of retrievable self-expandable metallic stents (REMSs) and identify predictors of technical failure in 81 patients with benign and malignant tracheobronchial strictures.Materials and MethodsA total of 98 REMSs were removed under fluoroscopic guidance in 81 patients with benign (n = 48) or malignant (n = 33) tracheobronchial strictures. Primary and secondary technical success rates and complication rate were evaluated. Technical outcomes with regard to underlying diseases were also evaluated. Logistic regression models were constructed to identify predictors of primary technical success.ResultsPrimary and secondary technical success rates were 86.7 and 94.9 %, respectively. Stent removal-related complication rate was 7.1 % (7/98) and all were bleeding after stent removal. All bleeding complications were minor and managed conservatively. Primary technical success rate for benign strictures was significantly lower compared with that for malignant strictures (80.9 vs. 97.1 %, P = 0.029), but secondary technical success rate (93.7 vs. 97.1 %, P = 0.652) did not differ between the two groups. Granulation tissue formation was identified as an independent predictor of primary technical success (odds ratio 0.249, 95 % CI 0.071–0.874, P = 0.030).ConclusionRemoval of REMSs in patients with benign and malignant tracheobronchial strictures is safe and technically feasible. Bronchoscopic guidance may be required when the removal using a hook wire fails. The presence of granulation tissue was the negative predictor of primary technical success.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of CeO{sub 2} NPs on biological phosphorus removal and bacterial community shifts in a sequencing batch biofilm reactor with the differential effects of molecular oxygen

The effects of CeO{sub 2} nanoparticles (CeO{sub 2} NPs) on a sequencing batch biofilm reactor (SBBR) with established biological phosphorus (P) removal were investigated from the processes of anaerobic P release and aerobic P uptake. At low concentration (0.1 mg/L), no significant impact was observed on total phosphorus (TP) removal after operating for 8 h. However, at a concentration of 20 mg/L, TP removal efficiency decreased from 83.68% to 55.88% and 16.76% when the CeO{sub 2} NPs were added at the beginning of the anaerobic and aerobic periods, respectively. Further studies illustrated that the inhibition of the specific P release rate was caused by the reversible states of Ce{sup 3+} and Ce{sup 4+}, which inhibited the activity of exopolyphosphatase (PPX) and transformation of poly-β-hydoxyalkanoates (PHA) and glycogen, as well as the uptake of volatile fatty acids (VFAs). The decrease in the specific P uptake rate was mainly attributed to the significantly suppressed energy generation and decreased abundance of Burkholderia caused by excess reactive oxygen species. The removal of chemical oxygen demand (COD) was not influenced by CeO{sub 2} NPs under aerobic conditions, due to the increased abundance of Acetobacter and Acidocella after exposure. The inhibitory effects of CeO{sub 2} NPs with molecular oxygen were reduced after anaerobic exposure due to the enhanced particle size and the presence of Ce{sup 3+}. - Highlights: • CeO{sub 2} NPs (20 mg/L) had a notable toxicity effect on P removal in SBBR system. • The deteriorated SPRR was caused by the inhibited key enzyme activity (PPX). • The decreased SPUR was caused by the bacterial community shifts. • Ce ions converting and excess ROS generation are related toxicity mechanisms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoadsorbents based on conducting polymer nanocomposites with main focus on polyaniline and its derivatives for removal of heavy metal ions/dyes: A review

Highlights: • Nanoadsorbents based on conductive polymers can remove heavy metal ions/dye. • Contact time, pH, adsorbent dosage and temperature are effective adsorption factors. • Chemical structures of nanoadsorbents play an important role in adsorption. • Adsorption of metal ions on PANI based nanocomposites is of physical type. Water contamination by toxic heavy metal ions and dyes remains a serious public health problem for humans, so attention on specific methods and technologies to remove heavy metal ions and dyes from wastewaters/aqueous solutions are desired. Numerous adsorbents have been reported for the removal of heavy metal ions/dyes from wastewaters/aqueous solutions. Polyaniline (PANI) and its derivatives, as conducting polymers, are good adsorbents to remove various kinds of heavy metal ions and dyes from wastewaters/aqueous solutions. The nanoadsorbents based on PANI and its derivatives have received much consideration, and are extensively reported in literature. This review focuses on the PANI and its derivatives based on nanoadsorbents for water purification. Various types of these nanoadsorbents used for the removal of heavy metal ions/dyes from wastewaters/aqueous solutions are also briefly compared in this review.

54 ENVIRONMENTAL SCIENCES↗

Reduction of Prostate Motion by Removal of Gas in Rectum During Radiotherapy

Purpose: To evaluate the prostate and seminal vesicle motion in patients during both simulation and radiotherapy by rectal gas removal. Methods and Materials: A total of 34 patients were treated in a whole pelvic radiotherapy (WPRT) arm and 42 patients in a non-WPRT arm. Of the 76 patients, 42 (26 in the non-WPRT arm and 16 in the WPRT arm) were instructed to insert their index finger and wash their rectums to evacuate their rectal gas. In addition to the planning computed tomography scan, three subsequent computed tomography scans were obtained during RT. The organs were outlined on each computed tomography image. Changes in the position of the prostate and seminal vesicles were analyzed using the center of mass (COM) coordinate system. The time trend, overall variations, systematic variations, and random variations were analyzed. Results: The average cross-sectional area in the rectal gas removal group was significantly smaller than in all patients and in the WPRT arm. The vector of the prostate and seminal vesicle displacement for the rectal gas removal group was significantly smaller than in all patients. With rectal gas removal, the 95% confidence limit of the prostate displacement vector was reduced by 2.3 mm in the non-WPRT arm and 2.9 mm in the WPRT arm. The 95% confidence limit of the seminal vesicle displacement vector was reduced by 0.3 mm in the non-WPRT arm and 4.4 mm in the WPRT arm. Conclusions: Using rectal gas removal, the cross-sectional area could be decreased, resulting in reduced motion and margins for the prostate and seminal vesicles. This is especially important for WPRT patients who require RT to the prostate, seminal vesicles, and pelvic lymph nodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of Fe-doped biochar in Cr(VI) removal from washing wastewater and residual Cr(VI) immobilization in contaminated soil

High-content Cr(VI)-contaminated soils are challenging to remediate using a single remediation technique. This study combined soil washing and immobilization to remediate high-content (3440 mg kg -1 ) Cr(VI)-contaminated soil, which investigated the effects of operating time, temperature, and liquid-solid ratio (LSR) on the Cr(VI) removal efficiency of soil washing and evaluated the potential of Fe-doped biochar (FeBC) in soluble Cr(VI) removal from the washing wastewater and residual Cr(VI) immobilization in the washed soil. The Cr(VI) removal efficiency of soil washing increased with the operating time, temperature, and LSR, but still cannot remove Cr(VI) to achieve the safety content (<100 mg kg -1 ). FeBC showed satisfactory potential in both Cr(VI) removal and immobilization from wastewater and soil, in which the main mechanisms involve ion exchange, redox, and coprecipitation. These results demonstrate applying soil washing & immobilization to remediate high-content Cr(VI)-contaminated soil is a promising alternative method.

54 ENVIRONMENTAL SCIENCES↗

Removal of Chalk River unidentified deposit (CRUD) radioactive waste by enhanced electrokinetic process

Decontamination techniques proposed and used to remove Chalk River unidentified deposit (CRUD) in radioactive waste management. In cases of huge volumes of metal or radionuclides contaminated by CRUD, removal of CRUD by mechanical or chemical decontamination is difficult. An advanced electrokinetic process combined with chemical decontamination was applied to remove CRUD and experimentally evaluated. We used oxalic acid for CRUD removal, and cobalt (Co) released from the CRUD was transferred to the cathode in an electrokinetic reactor. Our results indicate that the combined system is efficient for CRUD removal with enhanced, efficiency by use of the cation exchange membrane and zeolite.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗