Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REACTOR NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

279 records · Page 16

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Uncertainty Quantification for Data-Driven Machine Learning Models in Nuclear Engineering Applications: Where We Are and What Do We Need?

Machine learning (ML) has been leveraged to tackle a diverse range of tasks in almost all branches of nuclear engineering. Many of the successes in ML applications can be attributed to the recent performance breakthroughs in deep learning, the growing availability of computational power, data, and easy-to-use ML libraries. However, these empirical successes have often outpaced our formal understanding of the ML algorithms. An important but under-rated area is uncertainty quantification (UQ) of ML. ML-based models are subject to approximation uncertainty when they are used to make predictions, due to sources including but not limited to, data noise, data coverage, extrapolation, imperfect model architecture and the stochastic training process. The goal of this paper is to clearly explain and illustrate the importance of UQ of ML. We will elucidate the differences in the basic concepts of UQ of physics-based models and data-driven ML models. Various sources of uncertainties in physical modeling and data-driven modeling will be discussed, demonstrated, and compared. We will also present and demonstrate a few techniques to quantify the ML prediction uncertainties, including Monte Carlo dropout, deep ensemble, Bayesian neural networks, Gaussian Processes and conformal prediction. Lastly, we will discuss the need for building a verification, validation and UQ framework to establish ML credibility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Kilovoltage energy imaging with a radiotherapy linac with a continuously variable energy range

Purpose: In this paper, the effect on image quality of significantly reducing the primary electron energy of a radiotherapy accelerator is investigated using a novel waveguide test piece. The waveguide contains a novel variable coupling device (rotovane), allowing for a wide continuously variable energy range of between 1.4 and 9 MeV suitable for both imaging and therapy.Method: Imaging at linac accelerating potentials close to 1 MV was investigated experimentally and via Monte Carlo simulations. An imaging beam line was designed, and planar and cone beam computed tomography images were obtained to enable qualitative and quantitative comparisons with kilovoltage and megavoltage imaging systems. The imaging beam had an electron energy of 1.4 MeV, which was incident on a water cooled electron window consisting of stainless steel, a 5 mm carbon electron absorber and 2.5 mm aluminium filtration. Images were acquired with an amorphous silicon detector sensitive to diagnostic x-ray energies. Results: The x-ray beam had an average energy of 220 keV and half value layer of 5.9 mm of copper. Cone beam CT images with the same contrast to noise ratio as a gantry mounted kilovoltage imaging system were obtained with doses as low as 2 cGy. This dose is equivalent to a single 6 MV portal image. While 12 times higher than a 100 kVp CBCT system (Elekta XVI), this dose is 140 times lower than a 6 MV cone beam imaging system and 6 times lower than previously published LowZ imaging beams operating at higher (4-5 MeV) energies. Conclusions: The novel coupling device provides for a wide range of electron energies that are suitable for kilovoltage quality imaging and therapy. The imaging system provides high contrast images from the therapy portal at low dose, approaching that of gantry mounted kilovoltage x-ray systems. Additionally, the system provides low dose imaging directly from the therapy portal, potentially allowing for target tracking during radiotherapy treatment. There is the scope with such a tuneable system for further energy reduction and subsequent improvement in image quality.

43 PARTICLE ACCELERATORS↗

Novel dual-reflection design applied for ITER core x-ray spectrometer

Here. a novel dual-reflection configuration is introduced for the International Tokamak Experimental Reactor (ITER) core x-ray spectrometer to fit the allocated space where it will be placed accompanied by moving the detectors backward to reduce the incident radiation dose. The highly oriented pyrolytic graphite, which has a mosaic structure of microscopic crystallites, is chosen for the front reflector motivated by higher x-ray throughput and stronger misalignment tolerance compared to the perfect crystal reflector. In the ITER core x-ray spectrometer, a combination of several reflector-deflected Lines of Sight (LOSs) and a direct LOS is proposed for the first time named X-Ray Crystal Spectroscopy Core (XRCS-Core). The system is optimized to observe lines from externally seeded xenon and the intrinsic tungsten impurity, meeting both port integration needs and measurement requirements. Its spectral performance is simulated using an analytical-raytracing mixed code——XRSA, showing good imaging quality with a spectral resolution higher than 8000. The XRCS-Core system is thought to be applicable in various ITER scenarios through the assessment taking into account the spectrometers’ specifications and the chosen lines’ emissivity in different plasma parameters.

47 OTHER INSTRUMENTATION↗

ROBUST ONLINE MONITORING FOR CALIBRATION ASSESSMENT OF TRANSMITTERS AND INSTRUMENTATION

Robust online monitoring (OLM) technologies are expected to enable the extension or elimination of periodic sensor calibration intervals in operating and new reactors. Specifically, the next generation of OLM technology is expected to include newly developed advanced algorithms that improve monitoring of sensor/system performance and enable the use of plant data to derive information that currently cannot be measured. These advances in OLM technologies will improve the safety and reliability of current and planned nuclear power systems through improved accuracy and increased reliability of sensors used to monitor key parameters. In this paper, we discuss an overview of research being performed within the Nuclear Energy Enabling Technologies (NEET)/Advanced Sensors and Instrumentation (ASI) program, for the development of OLM algorithms to use sensor outputs and, in combination with other available information, 1) determine whether one or more sensors are out of calibration or failing and 2) replace a failing sensor with reliable, accurate sensor outputs. Algorithm development is focused on the following OLM functions: • Signal validation – fault detection and selection of acceptance criteria • Virtual sensing – signal value prediction and acceptance criteria • Response-time assessment – fault detection and acceptance criteria selection A GP-based uncertainty quantification (UQ) method previously developed for UQ in OLM, was adapted for use in sensor-fault detection and virtual sensing. For signal validation, the various components to the OLM residual (which is computed using an AAKR model) were explicitly defined and modeled using a GP. Evaluation was conducted using flow loop data from multiple sources. Results using experimental data from laboratory-scale flow loops indicate that the approach, while capable of detecting sensor drift, may be incapable of discriminating between sensor drift and model inadequacy. This may be due to a simplification applied in the initial modeling, where the sensor degradation is assumed to be stationary. In the case of virtual sensors, the GP model was used in a predictive mode to estimate the correct sensor reading for sensors that may have failed. Results have indicated the viability of using this approach for virtual sensing. However, the GP model has proven to be computationally expensive, and so alternative algorithms for virtual sensing are being evaluated. Finally, automated approaches to performing noise analysis for extracting sensor response time were developed. Evaluation of this technique using laboratory-scale data indicates that it compares well with manual techniques previously used for noise analysis. Moreover, the automated and manual approaches for noise analysis also compare well with the current “gold standard”, hydraulic ramp testing, for response time monitoring. Ongoing research in this project is focused on further evaluation of the algorithms, optimization for accuracy and computational efficiency, and integration into a suite of tools for robust OLM that are applicable to monitoring sensor calibration state in nuclear power plants.

calibration interval extension↗

Imaging of Calibrated Defects in Additively Manufactured Materials: Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components

Additive manufacturing (AM, or 3D printing) for commercial nuclear energy applications is an emerging method for cost-efficient manufacturing aimed at replacing aging nuclear reactor parts and reducing costs for new construction. Known material flaws in AM include low-density regions consisting of non-sintered powder, which have to be detected to ensure the safety of long-term performance nuclear reactor components. Currently, limited options are available for nondestructive evaluation (NDE), either during or post manufacturing. As a solution to NDE of AM, we are developing pulsed thermal imaging which is non-contact, one-sided, and scalable to arbitrary size and shape of the AM parts. Pulsed thermography (PT) system utilizes a high intensity flash lamp to rapidly heat surface of sample, and a high sensitivity fast-frame megapixel infrared (IR) camera to capture data of surface temperature variations. The acquired data cube consists of a stack of surface temperature images taken at different times. Information about material internal defects is extracted by analyzing the data cube. This report provides results of preliminary performance evaluation of pulsed thermal imaging capability in detection of imprinted flaws in AM metallic structures. The flaws were introduced into AM parts as imprinted hemispherical low density regions, consisting of trapped un-sintered metallic powder. Specimens for developed for this study consisted of AM stainless steel 316 and Inconel 718 plates. The diameters of imprinted defects varied from 1mm to 8mm, and their depths below the plate flat surface varied between 1mm and 6mm. Pulsed thermal tomography (PTT) processes the measured data cube to obtain 3D reconstructions of material effusivity using a unique inversion algorithm developed at Argonne. PTT has been previously used in imaging of similar size flat bottom hole (FBH) simulated defects in stainless steel 316 and Inconel 718 specimens. In the study involving AM specimens, PTT imaging results have shown that 1mm-diameter defects located 1mm and 2mm below the surface of specimens were detectable. Larger size defects were detectable at greater depth. We also explored an alternative approach to detection of material flaws in PT data cube, which is using neural learning-based approach to blind source separation. Detection of small material defects requires finding features in the data cube which have signal contrast levels approaching sensitivity limit of IR camera. In this study, an optimized Neural Learning based Blind Source Separation (NLBSS) algorithm, including Principal Component Analysis (PCA), and Independent Component Analysis (ICA) is demonstrated to automatically extract principal temporal and spatial features of thermography frames to enhance flaw detection. By using the NLBSS algorithm, material internal defects can be automatically detected. Furthermore, this processing approach compensates for experimental thermal imaging artifacts, such as noise and uneven heating. By merging artificial intelligence with phtotothermics, the NDE system detects internal calibrated defects of various sizes and depths in AM nuclear-grade metallic alloys.

36 MATERIALS SCIENCE↗

The Economic and Societal Impact of Baseload Power Generation on Local Communities

In the United States (US), energy from coal, natural gas, and nuclear power plants produced approximately 3,500 TWh of electricity and accounted for 85% of total net generation in 2015. In 2015, coal and natural gas power plants each contributed about 33% of all generation in the US. generation II nuclear power plants represents about 20% of all electricity produced in the US and 62.4% of emission-free electricity in 2015. As a byproduct of electricity, combustion fossil fuel plants release hazardous emissions such as CO{sub 2}, N{sub 2}O, NOx and SO{sub 2}. CO{sub 2}, CH{sub 4}, and N{sub 2}O. Many of these emissions are major greenhouse gases (GHG) that have been linked to contributing to global climate change. The release of NOx and SO{sub 2} have a negative impact on human health and contribute to smog and acid rain. As a result, communities are often subjected to negative externalities such as pollution, noise, undesirable visuals, and safety concerns when sited near power plants. Though nuclear power plants do not produce any air emissions, there are concerns of nuclear waste, radiation leaks into the environment, and Fukushima-level accidents. With electricity generation, there are economic, safety, and environmental tradeoffs between the three technologies. These factors can contribute to negative and positive externalities for communities that are sited near baseload power plants. Davis (2010) using the hedonic price method found that communities living within 2 miles of power plants experience a 3-7% decrease in housing values. There is further evidence that those that live even closer experience larger decreases. While several studies focus on hedonic price methods and health effects, none have investigated and compared the socioeconomic indicators of communities near baseload power plants. The goal of this work is to investigate and examine relationship between societal and economic community indicators with respect to distance and generation technology. From a cost benefit standpoint an argument can be made based on the externalities from these power plants. Positive externalities that improve median incomes and home values could mean added tax revenue for local municipalities and governments. Typically, comparisons between generating technologies are made using the levelized cost of electricity (LCOE) and life cycle GHG emissions, however the impacts on local communities can also be used as a metric when comparing technologies. (authors)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Dependence of ion-cyclotron range of frequencies instabilities on species mix and fast-ion distribution: I. Stability

Ion cyclotron emission (ICE) driven by fast ions has the potential to be a reactor relevant diagnostic of confined and escaping fast ions; moreover, controlled experiments in magnetic fusion devices can shed light on similar magnetospheric instabilities below and above the ion cyclotron frequency f ci . Dedicated DIII-D experiments studied instabilities below f ci and at cyclotron harmonics l f ci by injecting thirteen different neutral beam populations into plasmas with different thermal compositions of H, D, and 3He at five different values of toroidal field. High-frequency magnetic loops diagnose mode properties. Each beam type is individually injected for an approximate slowing-down time (~100 ms), resulting in a database of 2529 conditions that are analyzed in frequency bands corresponding to ICE harmonics and < f ci global Alfvén eigenmodes. The sub-cyclotron modes are more unstable at low field and in plasmas with large H concentration. For D injection, first harmonic ICE at f cD is more unstable in hydrogen plasmas but, for H injection, the converse is true (ICE at f cH is more unstable in D), suggesting that thermal same-species ions damp fundamental ICE. ICE stability also depends upon the pitch-angle anisotropy gradient and upon the ‘bump-on-tail’ gradient ∂f/∂v. Although the frequency of unstable ICE in these plasmas always occurs near the central cyclotron frequency, the precise value also depends on the Alfvén speed and beam direction, consistent with the idea that instability occurs for modes that simultaneously satisfy ω ≃ 2πlf ci , the magnetosonic dispersion relation, and the Doppler-shifted resonance condition.

electromagnetic ion cyclotron instabilities↗

Serpentine: Finite Difference Methods for Wave Propagation in Second Order Formulation

Wave propagation phenomena are important in many DOE applications such as nuclear explosion monitoring, geophysical exploration, estimating ground motion hazards and damage due to earthquakes, non-destructive testing, underground facilities detection, and acoustic noise propagation. There are also future applications that would benefit from simulating wave propagation, such as geothermal energy applications and monitoring sites for carbon storage via seismic reflection techniques. In acoustics and seismology, it is of great interest to increase the frequency bandwidth in simulations. In seismic exploration, greater frequency resolution enables shorter wave lengths to be included in the simulations, allowing for better resolution in the seismic imaging. In nuclear explosion monitoring, higher frequency seismic waves are essential for accurate discrimination between explosions and earthquakes. When simulating earthquake induced motion of large structures, such as nuclear power plants or dams, increased frequency resolution is essential for realistic damage predictions. Another example is simulations of micro-seismic activity near geothermal energy plants. Here, hydro-fracturing induces many small earthquakes and the time scale of each event is proportional to the square root of the moment magnitude. As a result, the motion is dominated by higher frequencies for smaller seismic events. The above wave propagation problems are all governed by systems of hyperbolic partial differential equations in second order differential form, i.e., they contain second order partial derivatives of the dependent variables. Our general research theme in this project has been to develop numerical methods that directly discretize the wave equations in second order differential form. The obvious advantage of working with hyperbolic systems in second order differential form, as opposed to rewriting them as first order hyperbolic systems, is that the number of differential equations in the second order system is significantly smaller. Another issue with re-writing a second order system into first order form is that compatibility conditions often must be imposed on the first order form. These (Saint-Venant) conditions ensure that the solution of the first order system also satisfies the original second order system. However, such conditions can be difficult to enforce on the discretized equations, without introducing additional modeling errors. This project has previously developed robust and memory efficient algorithms for wave propagation including effects of curved boundaries, heterogeneous isotropic, and viscoelastic materials. Partially supported by internal funding from Lawrence Livermore National Laboratory, many of these methods have been implemented in the open source software WPP, which is geared towards 3-D seismic wave propagation applications. This code has shown excellent scaling on up to 32,768 processors and has enabled seismic wave calculations with up to 26 Billion grid points. The WPP calculations have resulted in several publications in the field of computational seismology, e.g.. All of our current methods are second order accurate in both space and time. The benefits of higher order accurate schemes for wave propagation have been known for a long time, but have mostly been developed for first order hyperbolic systems. For second order hyperbolic systems, it has not been known how to make finite difference schemes stable with free surface boundary conditions, heterogeneous material properties, and curvilinear coordinates. The importance of higher order accurate methods is not necessarily to make the numerical solution more accurate, but to reduce the computational cost for obtaining a solution within an acceptable error tolerance. This is because the accuracy in the solution can always be improved by reducing the grid size h. However, in practice, the available computational resources might not be large enough to solve the problem with a low order method.

15 GEOTHERMAL ENERGY↗