Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIOLOGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Letter to the Editor: Appropriate selection of dose coefficients in radiological assessments: C-14 and Cl-36: response to the letter of G Smith and M Thorne (2015 J. Radiol. Prot. 35 737-40)

This letter to the editor of Journal of Radiological Protection is in response to a letter to the editor from G. M. Smith and M. C. Thorne of Great Britain concerning the appropriate selection of dose coefficients for ingested carbon-14 and chlorine-36, two of the most important long-lived components of radioactive wastes. Smith and Thorne argue that current biokinetic models of the International Commission on Radiological Protection (ICRP) for carbon and chlorine are overly cautious models from the standpoint of radiation dose estimates for C-14 and Cl-36, and that more realistic models are needed for evaluation of the hazards of these radionuclides in nuclear wastes. We (Harrison and Leggett) point out that new biokinetic models for these and other elements (developed at ORNL) will soon appear in ICRP Publications. These new models generally are considerably more realistic than current ICRP models. Here, examples are given for C-14 inhaled as carbon dioxide or ingested in water as bicarbonate, carbonate, or carbon dioxide.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

National Atmospheric Release Advisory Center dispersion modeling of the Full-scale Radiological Dispersal device (FSRDD) field trials

The results of the National Atmospheric Release Advisory Center (NARAC) model simulations are compared to measured data from the Full-Scale Radiological Dispersal Device (FSRDD) field trials. The series of explosive radiological dispersal device (RDD) experiments was conducted in 2012 by Defence Research and Development Canada (DRDC) and collaborating organizations. During the trials, a wealth of data was collected, including a variety of deposition and air concentration measurements. The experiments were conducted with one of the stated goals being to provide measurements to atmospheric dispersion modelers. These measurements can be used to facilitate important model validation studies. For this study, meteorological observations recorded during the tests are input to the diagnostic meteorological model, ADAPT, which provides 3–D, time-varying mean wind and turbulence fields to the LODI dispersion model. LODI concentration and deposition results are compared to the measured data, and the sensitivity of the model results to changes in input conditions (such as the particle activity size distribution of the source) and model physics (such as the rise of the buoyant cloud of explosive products) is explored. The NARAC simulations predicted the experimentally measured deposition results reasonably well considering the complexity of the release. Lastly, changes to the activity size distribution of the modeled particles can improve the agreement of the model results to measurement.

54 ENVIRONMENTAL SCIENCES↗

Reconstruction of A Radiological Release Using Aerosol Sampling

Reconstructing a radiological release using offsite air sampling is considered using measurements from the WIPP site event. Demonstration of the capabilities is shown using the HotSpot code as an example of the approach in general. The re-sults show the empirical steps that could be folded into an iterative approach to back extrapolation of a radiological release from a nuclear facility. It is shown here that the limiting factor in detec-tion is not counting statistics of the activity but rather the statistics for aerosols having small sample population numbers due to the lognormal distribution of particle radii.

61 RADIATION PROTECTION AND DOSIMETRY↗

Applying ALARA Principles in the Design of New Radiological Facilities

The application of ALARA (As Low As Reasonably Achievable) principles to the design of new radiological facilities at Argonne National Laboratory provides a consistent radiation safety basis for future facility operations. The Department of Energy Rule 10 CFR 835 specifies design objectives to be adopted during the design of new facilities for controlling personal radiation exposure. One is to keep exposure levels below 20% of the applicable standards in 10 CFR 835.202. For a radiation worker 20% of the standard corresponds to 5 µSv hr -1 for a 2,000 hour work year. For a member of the public the DOE design objective corresponds to 0.2 mSv in a calendar year. For a new facility worst case radionuclides and their source strengths are chosen. Local shielding is specified to reduce exposure rates to less than 50 µSv hr -1 at 30 cm from the shielding. The current version MCNP6 of the Los Alamos radiation shielding computer program MCNP is then used to calculate the exposure rates elsewhere. Design modifications are made to meet the criteria. The calculations and resulting facility design modifications are discussed for two new radiological facilities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Learning Cue Phrase Patterns from Radiology Reports Using a Genetic Algorithm

Various computer-assisted technologies have been developed to assist radiologists in detecting cancer; however, the algorithms still lack high degrees of sensitivity and specificity, and must undergo machine learning against a training set with known pathologies in order to further refine the algorithms with higher validity of truth. This work describes an approach to learning cue phrase patterns in radiology reports that utilizes a genetic algorithm (GA) as the learning method. The approach described here successfully learned cue phrase patterns for two distinct classes of radiology reports. These patterns can then be used as a basis for automatically categorizing, clustering, or retrieving relevant data for the user.

Patton, Robert M↗

Combining Radiography and Passive Measurements for Radiological Threat Localization in Cargo

Detecting shielded special nuclear material (SNM) in a cargo container is a difficult problem, since shielding reduces the amount of radiation escaping the container. Radiography provides information that is complementary to that provided by passive gamma-ray detection systems: while not directly sensitive to radiological materials, radiography can reveal highly shielded regions that may mask a passive radiological signal. Combining these measurements has the potential to improve SNM detection, either through improved sensitivity or by providing a solution to the inverse problem to estimate source properties (strength and location). We present a data-fusion method that uses a radiograph to provide an estimate of the radiation-transport environment for gamma rays from potential sources. This approach makes quantitative use of radiographic images without relying on image interpretation, and results in a probabilistic description of likely source locations and strengths. We present results for this method for a modeled test case of a cargo container passing through a plastic-scintillator-based radiation portal monitor and a transmission-radiography system. We find that a radiograph-based inversion scheme allows for localization of a low-noise source placed randomly within the test container to within 40 cm, compared to 70 cm for triangulation alone, while strength estimation accuracy is improved by a factor of six. Improvements are seen in regions of both high and low shielding, but are most pronounced in highly shielded regions. The approach proposed here combines transmission and emission data in a manner that has not been explored in the cargo-screening literature, advancing the ability to accurately describe a hidden source based on currently-available instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiological issues associated with the recent boom in oil and gas hydraulic fracturing

As the worldwide hydraulic fracturing 'fracking' market continued to grow to an estimated $37 Billion in 2012, the need to understand and manage radiological issues associated with fracking is becoming imperative. Fracking is a technique that injects pressurized fluid into rock layer to propagate fractures that allows natural gas and other petroleum products to be more easily extracted. Radioactivity is associated with fracking in two ways. Radioactive tracers are frequently a component of the injection fluid used to determine the injection profile and locations of fractures. Second, because there are naturally-occurring radioactive materials (NORM) in the media surrounding and containing oil and gas deposits, the process of fracking can dislodge radioactive materials and transport them to the surface in the wastewater and gases. Treatment of the wastewater to remove heavy metals and other contaminates can concentrate the NORM into technologically-enhanced NORM (TENORM). Regulations to classify, transport, and dispose of the TENORM and other radioactive waste can be complicated and cumbersome and vary widely in the international community and even between states/provinces. In many cases, regulations on NORM and TENORM do not even exist. Public scrutiny and regulator pressure will only continue to increase as the world demands on oil and gas continue to rise and greater quantities of TENORM materials are produced. Industry experts, health physicists, regulators, and public communities must work together to understand and manage radiological issues to ensure reasonable and effective regulations protective of the public, environment, and worker safety and health are implemented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range

Purpose: Photon dosimetry in the kilovolt (kV) energy range represents a major challenge for diagnostic and interventional radiology and superficial therapy. Plastic scintillation detectors (PSDs) are potentially good candidates for this task. This study proposes a simple way to obtain accurate correction factors to compensate for the response of PSDs to photon energies between 80 and 150 kVp. The performance of PSDs is also investigated to determine their potential usefulness in the diagnostic energy range. Methods: A 1-mm-diameter, 10-mm-long PSD was irradiated by a Therapax SXT 150 unit using five different beam qualities made of tube potentials ranging from 80 to 150 kVp and filtration thickness ranging from 0.8 to 0.2 mmAl + 1.0 mmCu. The light emitted by the detector was collected using an 8-m-long optical fiber and a polychromatic photodiode, which converted the scintillation photons to an electrical current. The PSD response was compared with the reference free air dose rate measured with a calibrated Farmer NE2571 ionization chamber. PSD measurements were corrected using spectra-weighted corrections, accounting for mass energy-absorption coefficient differences between the sensitive volumes of the ionization chamber and the PSD, as suggested by large cavity theory (LCT). Beam spectra were obtained from x-ray simulation software and validated experimentally using a CdTe spectrometer. Correction factors were also obtained using Monte Carlo (MC) simulations. Percent depth dose (PDD) measurements were compensated for beam hardening using the LCT correction method. These PDD measurements were compared with uncorrected PSD data, PDD measurements obtained using Gafchromic films, Monte Carlo simulations, and previous data. Results: For each beam quality used, the authors observed an increase of the energy response with effective energy when no correction was applied to the PSD response. Using the LCT correction, the PSD response was almost energy independent, with a residual 2.1% coefficient of variation (COV) over the 80-150-kVp energy range. Monte Carlo corrections reduced the COV to 1.4% over this energy range. All PDD measurements were in good agreement with one another except for the uncorrected PSD data, in which an over-response was observed with depth (13% at 10 cm with a 100 kVp beam), showing that beam hardening had a non-negligible effect on the PSD response. A correction based on LCT compensated very well for this effect, reducing the over-response to 3%.Conclusion: In the diagnostic energy range, PSDs show high-energy dependence, which can be corrected using spectra-weighted mass energy-absorption coefficients, showing no considerable sign of quenching between these energies. Correction factors obtained by Monte Carlo simulations confirm that the approximations made by LCT corrections are valid. Thus, PSDs could be useful for real-time dosimetry in radiology applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using computer-extracted image features for modeling of error-making patterns in detection of mammographic masses among radiology residents

Purpose: Mammography is the most widely accepted and utilized screening modality for early breast cancer detection. Providing high quality mammography education to radiology trainees is essential, since excellent interpretation skills are needed to ensure the highest benefit of screening mammography for patients. The authors have previously proposed a computer-aided education system based on trainee models. Those models relate human-assessed image characteristics to trainee error. In this study, the authors propose to build trainee models that utilize features automatically extracted from images using computer vision algorithms to predict likelihood of missing each mass by the trainee. This computer vision-based approach to trainee modeling will allow for automatically searching large databases of mammograms in order to identify challenging cases for each trainee. Methods: The authors’ algorithm for predicting the likelihood of missing a mass consists of three steps. First, a mammogram is segmented into air, pectoral muscle, fatty tissue, dense tissue, and mass using automated segmentation algorithms. Second, 43 features are extracted using computer vision algorithms for each abnormality identified by experts. Third, error-making models (classifiers) are applied to predict the likelihood of trainees missing the abnormality based on the extracted features. The models are developed individually for each trainee using his/her previous reading data. The authors evaluated the predictive performance of the proposed algorithm using data from a reader study in which 10 subjects (7 residents and 3 novices) and 3 experts read 100 mammographic cases. Receiver operating characteristic (ROC) methodology was applied for the evaluation. Results: The average area under the ROC curve (AUC) of the error-making models for the task of predicting which masses will be detected and which will be missed was 0.607 (95% CI,0.564-0.650). This value was statistically significantly different from 0.5 (p < 0.0001). For the 7 residents only, the AUC performance of the models was 0.590 (95% CI,0.537-0.642) and was also significantly higher than 0.5 (p = 0.0009). Therefore, generally the authors’ models were able to predict which masses were detected and which were missed better than chance. Conclusions: The authors proposed an algorithm that was able to predict which masses will be detected and which will be missed by each individual trainee. This confirms existence of error-making patterns in the detection of masses among radiology trainees. Furthermore, the proposed methodology will allow for the optimized selection of difficult cases for the trainees in an automatic and efficient manner.

60 APPLIED LIFE SCIENCES↗

Characterization of a MOSkin detector for in vivo skin dose measurements during interventional radiology procedures

Purpose: The MOSkin is a MOSFET detector designed especially for skin dose measurements. This detector has been characterized for various factors affecting its response for megavoltage photon beams and has been used for patient dose measurements during radiotherapy procedures. However, the characteristics of this detector in kilovoltage photon beams and low dose ranges have not been studied. The purpose of this study was to characterize the MOSkin detector to determine its suitability for in vivo entrance skin dose measurements during interventional radiology procedures. Methods: The calibration and reproducibility of the MOSkin detector and its dependency on different radiation beam qualities were carried out using RQR standard radiation qualities in free-in-air geometry. Studies of the other characterization parameters, such as the dose linearity and dependency on exposure angle, field size, frame rate, depth-dose, and source-to-surface distance (SSD), were carried out using a solid water phantom under a clinical x-ray unit. Results: The MOSkin detector showed good reproducibility (94%) and dose linearity (99%) for the dose range of 2 to 213 cGy. The sensitivity did not significantly change with the variation of SSD (±1%), field size (±1%), frame rate (±3%), or beam energy (±5%). The detector angular dependence was within ±5% over 360° and the dose recorded by the MOSkin detector in different depths of a solid water phantom was in good agreement with the Markus parallel plate ionization chamber to within ±3%. Conclusions: The MOSkin detector proved to be reliable when exposed to different field sizes, SSDs, depths in solid water, dose rates, frame rates, and radiation incident angles within a clinical x-ray beam. The MOSkin detector with water equivalent depth equal to 0.07 mm is a suitable detector for in vivo skin dosimetry during interventional radiology procedures.

60 APPLIED LIFE SCIENCES↗

SU-E-T-424: Feasibility of 3D Printed Radiological Equivalent Customizable Tissue Like Materials

Purpose: To investigate the feasibility of 3D printing CT# specific radiological equivalent tissue like materials. Methods: A desktop 3D printer was utilized to create a series of 3 cm x 3 cm x 2 cm PLA plastic blocks of varying fill densities. The fill pattern was selected to be hexagonal (Figure 1). A series of blocks was filled with paraffin and compared to a series filled with air. The blocks were evaluated with a “GE Lightspeed” 16 slice CT scanner and average CT# of the centers of the materials was determined. The attenuation properties of the subsequent blocks were also evaluated through their isocentric irradiation via “TrueBeam” accelerator under six beam energies. Blocks were placed upon plastic-water slabs of 4 cm in thickness assuring electronic equilibrium and data was collected via Sun Nuclear “Edge” diode detector. Relative changes in dose were compared with those predicted by Varian “Eclipse” TPS. Results: The CT# of 3D printed blocks was found to be a controllable variable. The fill material was able to narrow the range of variability in each sample. The attenuation of the block tracked with the density of the total fill structure. Assigned CT values in the TPS were seen to fall within an expected range predicted by the CT scans of the 3D printed blocks. Conclusion: We have demonstrated that it is possible to 3D print materials of varying tissue equivalencies, and that these materials have radiological properties that are customizable and predictable.

60 APPLIED LIFE SCIENCES↗

Accuracy and calibration of integrated radiation output indicators in diagnostic radiology: A report of the AAPM Imaging Physics Committee Task Group 190

Due to the proliferation of disciplines employing fluoroscopy as their primary imaging tool and the prolonged extensive use of fluoroscopy in interventional and cardiovascular angiography procedures, “dose-area-product” (DAP) meters were installed to monitor and record the radiation dose delivered to patients. In some cases, the radiation dose or the output value is calculated, rather than measured, using the pertinent radiological parameters and geometrical information. The AAPM Task Group 190 (TG-190) was established to evaluate the accuracy of the DAP meter in 2008. Since then, the term “DAP-meter” has been revised to air kerma-area product (KAP) meter. The charge of TG 190 (Accuracy and Calibration of Integrated Radiation Output Indicators in Diagnostic Radiology) has also been realigned to investigate the “Accuracy and Calibration of Integrated Radiation Output Indicators” which is reflected in the title of the task group, to include situations where the KAP may be acquired with or without the presence of a physical “meter.” To accomplish this goal, validation test protocols were developed to compare the displayed radiation output value to an external measurement. These test protocols were applied to a number of clinical systems to collect information on the accuracy of dose display values in the field.

60 APPLIED LIFE SCIENCES↗

Sensitivity of the diagnostic radiological index of protection to procedural factors in fluoroscopy

Purpose: To evaluate the sensitivity of the diagnostic radiological index of protection (DRIP), used to quantify the protective value of radioprotective garments, to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams to be used in measuring the DRIP. Methods: Monte Carlo simulations were performed to determine the shape of the scattered x-ray spectra incident on the operator in different clinical fluoroscopy scenarios, including interventional radiology and interventional cardiology (IC). Two clinical simulations studied the sensitivity of the scattered spectrum to gantry angle and patient size, while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial simulations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size, and beam quality for constant technical factors. Average energy (E{sub avg}) was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affect the scattered spectrum indirectly through their effect on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in IC, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusions: The scattered spectrum striking the operator in fluoroscopy is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle.

60 APPLIED LIFE SCIENCES↗

SU-D-209-03: Radiation Dose Reduction Using Real-Time Image Processing in Interventional Radiology

Purpose: To characterize changes in radiation dose after introducing a new real-time image processing technology in interventional radiology systems. Methods: Interventional radiology (IR) procedures are increasingly complex, at times requiring substantial time and radiation dose. The risk of inducing tissue reactions as well as long-term stochastic effects such as radiation-induced cancer is not trivial. To reduce this risk, IR systems are increasingly equipped with dose reduction technologies.Recently, ClarityIQ (Philips Healthcare) technology was installed in our existing neuroradiology IR (NIR) and vascular IR (VIR) suites respectively. ClarityIQ includes real-time image processing that reduces noise/artifacts, enhances images, and sharpens edges while also reducing radiation dose rates. We reviewed 412 NIR (175 pre- and 237 post-ClarityIQ) procedures and 329 VIR (156 preand 173 post-ClarityIQ) procedures performed at our institution pre- and post-ClarityIQ implementation. NIR procedures were primarily classified as interventional or diagnostic. VIR procedures included drain port, drain placement, tube change, mesenteric, and implanted venous procedures. Air Kerma (AK in units of mGy) was documented for all the cases using a commercial radiation exposure management system. Results: When considering all NIR procedures, median AK decreased from 1194 mGy to 561 mGy. When considering all VIR procedures, median AK decreased from 49 to 14 mGy. Both NIR and VIR exhibited a decrease in AK exceeding 50% after ClarityIQ implementation, a statistically significant (p<0.05) difference. Of the 5 most common VIR procedures, all median AK values decreased, but significance (p<0.05) was only reached in venous access (N=53), angio mesenteric (N=41), and drain placement procedures (N=31). Conclusion: ClarityIQ can reduce dose significantly for both NIR and VIR procedures. Image quality was not assessed in conjunction with the dose reduction.

60 APPLIED LIFE SCIENCES↗

MO-DE-204-03: Radiology Dose Optimisation - An Australian Perspective

The main topic of the session is to show how dose optimization is being implemented in various regions of the world, including Europe, Australia, North America and other regions. A multi-national study conducted under International Atomic Energy Agency (IAEA) across more than 50 less resourced countries gave insight into patient radiation doses and safety practices in CT, mammography, radiography and interventional procedures, both for children and adults. An important outcome was the capability development on dose assessment and management. An overview of recent European projects related to CT radiation dose and optimization both to adults and children will be presented. Existing data on DRLs together with a European methodology proposed on establishing and using DRLs for paediatric radiodiagnostic imaging and interventional radiology practices will be shown. Compared with much of Europe at least, many Australian imaging practices are relatively new to the task of diagnostic imaging dose optimisation. In 2008 the Australian Government prescribed a requirement to periodically compare patient radiation doses with diagnostic reference levels (DRLs), where DRLs have been established. Until recently, Australia had only established DRLs for computed tomography (CT). Regardless, both professional society and individual efforts to improved data collection and develop optimisation strategies across a range of modalities continues. Progress in this field, principally with respect to CT and interventional fluoroscopy will be presented. In the US, dose reduction and optimization efforts for computed tomography have been promoted and mandated by several organizations and accrediting entities. This presentation will cover the general motivation, implementation, and implications of such efforts. Learning Objectives: Understand importance of the dose optimization in Diagnostic Radiology. See how this goal is achieved in different regions of the World. Learn about the global trend in the dose optimization and future prospectives. M. Rehani, The work was a part of the work of IAEA where I was an employee and IAEA is a United Nations organization.

60 APPLIED LIFE SCIENCES↗

MO-DE-204-00: International Symposium: Patient Dose Reduction in Diagnostic Radiology

The main topic of the session is to show how dose optimization is being implemented in various regions of the world, including Europe, Australia, North America and other regions. A multi-national study conducted under International Atomic Energy Agency (IAEA) across more than 50 less resourced countries gave insight into patient radiation doses and safety practices in CT, mammography, radiography and interventional procedures, both for children and adults. An important outcome was the capability development on dose assessment and management. An overview of recent European projects related to CT radiation dose and optimization both to adults and children will be presented. Existing data on DRLs together with a European methodology proposed on establishing and using DRLs for paediatric radiodiagnostic imaging and interventional radiology practices will be shown. Compared with much of Europe at least, many Australian imaging practices are relatively new to the task of diagnostic imaging dose optimisation. In 2008 the Australian Government prescribed a requirement to periodically compare patient radiation doses with diagnostic reference levels (DRLs), where DRLs have been established. Until recently, Australia had only established DRLs for computed tomography (CT). Regardless, both professional society and individual efforts to improved data collection and develop optimisation strategies across a range of modalities continues. Progress in this field, principally with respect to CT and interventional fluoroscopy will be presented. In the US, dose reduction and optimization efforts for computed tomography have been promoted and mandated by several organizations and accrediting entities. This presentation will cover the general motivation, implementation, and implications of such efforts. Learning Objectives: Understand importance of the dose optimization in Diagnostic Radiology. See how this goal is achieved in different regions of the World. Learn about the global trend in the dose optimization and future prospectives. M. Rehani, The work was a part of the work of IAEA where I was an employee and IAEA is a United Nations organization.

60 APPLIED LIFE SCIENCES↗

Genetic Algorithm for Analysis of Abdominal Aortic Aneurysms in Radiology Reports

An abdominal aortic aneurysm is a problem in which the wall of the artery that supplies blood to the abdomen and lower extremities expands under pressure or balloons outward. Patients must undergo surgery to repair such aneurysm, and there is currently no known indicator of success or failure from this surgery. Our work uses a genetic algorithm to analyze radiology reports from these patients to look for common patterns in the language used as well as common features of both successful and unsuccessful surgieries. The results of the genetic algorithm show that patients with complications or unusual characteristics can be identified from a set of radiology reports without the use of search keywords, clustering, categorization, or ontology. This allows medical researchers to search and identify interesting patient records without the need for explicitly defining what interesting patient records are.

Patton, Robert M↗

International Commission on Radiological Protection Committee 1: Current Status and Future Directions

The International Commission on Radiological Protection (ICRP), Committee 1 (C1) considers the risk of induction of cancer and heritable disease (stochastic effects) together with the underlying mechanisms of radiation action. C1 also considers the risks, severity, and mechanisms of induction of tissue/organ damage and developmental defects (deterministic effects). The committee was significantly revamped in 2013 and last met in Abu Dhabi in October of 2013. C1 evaluated progress on two ongoing Task Groups (TG’s); TG 64 “Cancer Risk from Alpha Emitters” and TG 75 “Stem Cell Radiobiology”. Following approval from the Main Commission (MC), C1 established two new TG’s; TG 91 “Radiation Risk Inference at Low Dose and Low Dose Rate Exposure for Radiological Protection Purposes”, and TG 92 “Terminology and Definitions”. Here I will present a synopsis of the current status of C1 and outline the tasks C1 may undertake in the future.

Morgan, William F.↗